بھائی جان الله پاک سے دعا ہے کہ اللہ پاک آپ کو صحت تندرستی عطا فرمائے اور آپ کے کاروبار رزق میں برکت اور رحمت فرمائے آمين❤
@zohaibmustafa16603 ай бұрын
Brother, I pray to Allah Almighty to grant you good health and bless you in your business and sustenance, Ameen.❤❤
@SakhawatHussain-h8t2 ай бұрын
Masha Allah
@KayYasin2 ай бұрын
Thanks
@mjkashmiriboy3 ай бұрын
Big fan sir g ❣️❣️
@Nature_lover6943 ай бұрын
You've done an outstanding job Masha ALLAH, keep it up!👍❤️
@rifatzia88643 ай бұрын
Excellent 👍
@KayYasin3 ай бұрын
Thank you
@rashadmahmood62683 ай бұрын
Great work good quality
@KayYasin3 ай бұрын
Thank u
@rashadmahmood62683 ай бұрын
@@KayYasin u welcome
@merasohnadadyal19893 ай бұрын
Very interesting and helpful Video👍👍 ❤
@KayYasin3 ай бұрын
Thanks
@bismillahcookenjoywithnadeem3 ай бұрын
good video khush rahain
@sadiavlogofficial63 ай бұрын
Mashallah❤❤❤🎉🎉
@Abidsalehuk3 ай бұрын
Great job and sorry to say , there is no gap for ventalation air due to condensation in winter problem. and what is the size of timber normally 7x 2 used 100-120 PIR insulation.
@KayYasin3 ай бұрын
@@Abidsalehuk there is about 100 ml gap in joist and if we add firrings which are 6 inch high one side and one inch high on other side so fairly alot of empty space for air to travell
@KayYasin3 ай бұрын
@@Abidsalehuk timber is aprox 200 u can say 8 inch
@Abidsalehuk3 ай бұрын
@@KayYasin That is good bro and I am still learning Lol
@realdigitalninja3 ай бұрын
salam bro, good video. you said its a 6/1 firrings. so is it 1 inch drop after every 6 inches ? or is it an inch per meter so if its a 6 meters span, there is a 6 inch drop ? please can you clarify? thanks
@KayYasin3 ай бұрын
Yes its 6 inch drop brother
@abskan40153 ай бұрын
This is a hybrid roof. The problem you will have is condensation in the winter. There is no cross flow ventilation on this roof. Are you planning to put mushrooms on top? You will have issues in the winter with sweating. You also didn't use a vapour barrier.
@KayYasin3 ай бұрын
We have kept the ventilation on top brother by adding a 6/1 fiirings and the insulation we added between the joist is 100ml so we have a empty space on top of that too whicb allows air movement back to front but thanks anyways
@abskan40153 ай бұрын
@@KayYasin you will need venting on the other side. Through venting is a must. Otherwise you will have issues.
@KayYasin3 ай бұрын
@@abskan4015 yes thats true we have that already through out brother and thanks again for supporting us we learn all our life brother
@Asadkhan-pe2je3 ай бұрын
@@KayYasinis this warm or cold roof?
@Funnyvideos-rc9sc3 ай бұрын
You need to add the firrings on any roof for the water flow into gutters. We appreciate your work but do not show too much detail it makes a lay person confused. This is a kind of hybrid roof that’s why you have the gap between insulations them for the air flow to avoid condensation.
@lalaa8272 ай бұрын
That's a hybrid roof a mix of a warm and cold roof, the insulation on top of the roof deck must always be thicker otherwise you get condensation. There's s chance condensation will build up in the air space formed below. Have you had a condensation risk analysis done by the roof insulation manufacturer?. Who specified this detail the architect?
@KayYasin2 ай бұрын
Thanj you very much brother but the fact is there is cavity space left between the 50mm pir boards and the roof joists 100mm PIR is inside the 8 x2 joists than on too of that we have added firrings with created about 100mm cavity for air to travell thanks anyways for the concern and a comment
@ihteramulhaq7863 ай бұрын
khana khane ky bad wasy bi dil nai krta km k.
@KayYasin3 ай бұрын
Han ji
@RaheelAslam-mc5bh3 ай бұрын
AoA Kal Hal ha baie
@KayYasin3 ай бұрын
@@RaheelAslam-mc5bh walikum salam
@ransin25003 ай бұрын
Hello Bhai , great job. Could you please give me Sukh paji bricklayer number please?
@KayYasin3 ай бұрын
Inbix me on facebook page paa ji
@Funnyvideos-rc9sc3 ай бұрын
Bro this is not the right build up for the flat roof … check the plans. It seems like a hybrid roof. Warm deck roof you put plywood, VCL, 150mm insulation, then timber again and then on top flat roof covering
@KayYasin3 ай бұрын
Thats has been done acording the engieers siggestion brother and it works to be honest. But if we google there are so many things dont work
@MrFazian-hr8ns3 ай бұрын
Bhai mera naam Faizan hai mere ko job ki zarurat hai aap mere ko UK mein job dila do helper mein please bhai
@RaheelAslam-mc5bh3 ай бұрын
Hello baie please
@ahtisham13 ай бұрын
Hybrid roof not a proper job
@KayYasin3 ай бұрын
Its not a hybrid roof mate if u see it we run the fiirings on top which are about 6 /1 and that is source of ventilation 100ml is between the joists and joist it self has epmpty space on top as well and the good thing is its acording to engineers designed anyways thanks