MASSIVE Savings With The Senville AURA Mini Split

  Рет қаралды 44,229

The DIY HVAC Guy

The DIY HVAC Guy

Күн бұрын

Senville Dual Zone Heat Pump: amzn.to/4dac4ry
America's #1 Choice For Quality, Affordable HVAC Equipment: Alpinehomeair.com
All my favorite HVAC tools: www.amazon.com...
Do you own a service business and need a customer management software?
Housecall Pro is the BEST CRM for small businesses and can save you so much time with scheduling, onboarding new customers, sending estimates etc.
Use my link to get 50% off the first 2 months: housecallpro.p...
Join our channel membership to gain access to exclusive HVAC training videos AND x10 entries for our monthly giveaways!! NO PURCHASE NEEDED. Prizes are valued anywhere between $500-$2000!
Join here: / @diyhvacguy
IF YOU ARE IN NEED OF ONE ON ONE GUIDANCE WITH YOUR HVAC SYSTEM, whether it is diagnosing a bad part, replacing your system, or help with sizing, check out our membership program here: / diyhvacguy
For a low price of $400, you will get assistance from myself when it comes to your hvac needs, whether it's sizing, diagnosing, or locating the correct equipment.
Here Is Where I Order All My Air Filters:
filterbuy.com/...
Follow us for more diy hvac tips & to enter for our giveaways!
Instagram: / diy_hvac_guy
Tiktok: www.tiktok.com...
Facebook: / selfmadehvac
⚠️ Disclaimer:
This video is for educational purposes. Any and all HVAC repair work is done at your own risk. Any person attempting to deal with any type of refrigerant MUST have their EPA 608 certificate. The DIY HVAC Guy channel is not responsible for any possible damages or injuries caused by the use or misuse of the provided information.
The DIY HVAC GUY is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.

Пікірлер: 135
@lasersbee
@lasersbee Ай бұрын
Since last year I've bought and installed a Senville 9K BTU Leto and a 24K BTU Aura in my home and a Senville 24K BTU Aura in my shop for Cooling and heating. They have Great Customer Service. Bought all the tools for installation and Learned how to install these units on KZbin with channels like yours. Thanks With the 24K in the shop we saved almost 50% of the heating costs over the year before. This coming winter I'll be testing the new 24K in the house..
@diyhvacguy
@diyhvacguy Ай бұрын
Amazing! Thanks for sharing!
@RH-nc8uu
@RH-nc8uu Ай бұрын
So do we know how these Midea built Senville compare to the also Midea built Mr Cool is one using cheaper components or are they identical?
@kellyrides429
@kellyrides429 Ай бұрын
I second on senville having great customer service!
@lasersbee
@lasersbee Ай бұрын
@@RH-nc8uu Have no clue... Just the name "Mr Cool" sounds like a cheap knock off to me. Senville is a local company so I bought from them.
@michaeldas7325
@michaeldas7325 Ай бұрын
@@diyhvacguy FYI you should use nylog when you are flaring the copper as a lubricant. Just put it on the cone part of the tool.
@thomask4836
@thomask4836 Ай бұрын
Hello! First, let me say that I LOVE all of your videos! Second, I used to work as an electrician in mining industries in the 70's. I wanted to mention something about the wires at 10:33. I saw the legend but the way we used to deal with colored wires was to match them to numbers in alphabetical order according to color: Black begins with the letter "B", White -"W" and so on. So, TB 1 = (B) Black TB 2 = (R) Red TB 3 = (W) White Alphabetical order! Never have to remember or write things down! I don't know if this will work for everything in the HVAC industry but thought I would humbly suggest it! Best Wishes and Take Care, Tom
@lasersbee
@lasersbee Ай бұрын
The order of the Wires is what Senville asks for.
@thomask4836
@thomask4836 Ай бұрын
@@lasersbee - As I mentioned, "I saw the legend" and totally agree but for other applications it may be useful. Kind Regards, Tom
@michaelcollins5438
@michaelcollins5438 Ай бұрын
That's a good tip, I like that concept
@thomask4836
@thomask4836 Ай бұрын
@@michaelcollins5438 - Thank You Sir!
@Time-Trvlr
@Time-Trvlr Ай бұрын
The crimped connectors on the wire ends are a makeshift ferrals, best for stranded wires.
@ShuhDonk
@ShuhDonk Ай бұрын
I just recently put in 7 of these ranging from 9k to 18k in ny home and pole barn/shop. They are super efficient and work fantastic. Plus since they are energy star you can claim a tax credit on them.
@ClippyC
@ClippyC Ай бұрын
lol - a ground rod is not an effective ground to clear a fault. Need to run the copper wire back to the main panel. nice install and looks awesome. Have any videos that talk about using a ducted minisplit to replace standard ac that sites on top of a furnace?
@ntsecrets
@ntsecrets Ай бұрын
Yeah I don’t get that lack of ground. I don’t think that meets code. Should be bonded to ground at the panel.
@TimJessen-b9v
@TimJessen-b9v Ай бұрын
The ground rod will not clear a ground fault, and if there is a ground fault,the condenser will be live voltage,and could kill someone who touches it. It needs an equipment ground wire run back to the panel to clear a fault.
@honemorrison4013
@honemorrison4013 Ай бұрын
why would a ground rod at the unit be any different from the ground rod at the panel when it comes to popping the breaker or fuse
@TimJessen-b9v
@TimJessen-b9v Ай бұрын
​@@honemorrison4013 the ground rod at the panel is connected to the ungrounded conductor with the system bonding jumper, creating a low resistance path to trip the breaker in case of a ground fault. A ground rod at best has 20 ohms resistance,and a ground fault with only a ground rod will only pass 4 -5amps,,,and not nearly enough to trip the breaker.
@TimJessen-b9v
@TimJessen-b9v Ай бұрын
Bonded to the grounded conductor ( neutral),,,not ungrounded,,
@honemorrison4013
@honemorrison4013 Ай бұрын
@@TimJessen-b9v gotcha
@lucianoandsonshvac
@lucianoandsonshvac Ай бұрын
The drain is not meant to go that way behind the head unit. There should be a plug on the unit near the hole you made that can be removed and put to the other side. Also if you remove the outer shell of the wall unit you can seal the hole behind the unit and will prevent more dust entering
@benr.3009
@benr.3009 Ай бұрын
Thank you again David! I don't now if you all can appreciate the difference in noise level in our house without the window units. We even had a portable 12000 BTU unit upstairs to help the window unit. this split system is game changing! Our little thermostat on the other side of the room matches what the unit says if not one degree colder. And to get rid of those death trap heaters was a bonus as well. we couldn't be happier with it.
@christophertuten6772
@christophertuten6772 25 күн бұрын
I have this same unit installed in our 1800 square foot pole barn, and it does a great job at heat and cooling. Worth every penny to upgrade from their base 17 seer model. We had the base model installed first, and it couldn't keep up, so we added the Aura, and now we never use the 17 seer model. The Aura is built like a 3 ton unit, but sold as a 2 ton. The inside unit, and outside units are much bigger than the 17 seer unit. It pulls the same wattage also, so you do get what you pay for.
@Optimization_Coach
@Optimization_Coach Ай бұрын
I love my minisplits/heatpumps. They are far superior to any of my conventional 4 ton units by a long shot
@JNHEscapes
@JNHEscapes Ай бұрын
You have made me want to get my 608 and start working on hvac’s. You make it easy to understand and I’ve been in tech all my life and about to retire. This looks fun!! The power flare tool rocked…I love anything that makes things efficient…not fast I take my time, but efficient and the best work product possible. Great job! I’m about to install an eg4 24k with solar. Looking forward to it…great videos! The more detail the better.
@sailingwiththegods538
@sailingwiththegods538 Ай бұрын
Where the lines need to be bent I use old 14 wire grounds and wrap them around the piping. I wrap them so they're 1/4" apart and electrical tape the ends to the tubing. It prevents the tubing from kinking. It works well for me. The ground needs to be tied into the house ground somewhere, otherwise it won't clear a fault and trip the breaker, you'll only get overload and dead short protection.
@Ahmad-Nader
@Ahmad-Nader Ай бұрын
So this is basically a rebranded Midea All Eazy Pro Mini Split. Very good and efficient units!
@shoretrade9516
@shoretrade9516 Ай бұрын
Yes, it looks identical to a Bosch also
@jackonthefarm5540
@jackonthefarm5540 Ай бұрын
At 14:57 you seem to wrap the high and low pressure lines together in one insulation covering. Shouldn't these be separated to avoid heat transfer between them?
@christraudt6730
@christraudt6730 4 күн бұрын
master electrician here - i admire your dedication to a high quality install, however the ground rod is next to useless. the purpose of ground rods is to create an equipotential plane with the utility provider and the structure it’s connected to. an equipment grounding conductor is what you were missing, and its job is to carry ground fault current back to the service where the ground and neutral are connected, this creates a complete circuit and allows a breaker to trip in the event of a ground fault. how you have it set up, unfortunately will not clear a ground fault, and the disconnect box and ac condenser will be live (120v) in the event of a ground fault. to rectify this, a ground must be ran to the panel where that electric strip heat breaker is.
@anticapitalize
@anticapitalize Ай бұрын
The drill bit flaring tools work well for these mini split connections. There's another video (forgot the source at this point) which compared all of the flaring tools and examined the results under a microscope and it turns out that those old-style flaring tools leave micro-scratches which eventually lead to leaks. The drill flares and the orbital flares performed the best, as I recall. Best practice is use to Nylog Blue regardless of which method you use to help with leak potential on all flared connections.
@munozinni
@munozinni Ай бұрын
Hola 👋 señor Dave!!! That was a great video very informative and educational and the best of all was that you showed the process of the installation …You are the best in A/C keep up the great work and content…You have a great day and weekend…Saludos!!!! 👋😃👋
@jimsiggy
@jimsiggy Ай бұрын
If you read that torque spec in the manual as "50 foot-pounds" rather than what it says, "50 Newton-meters," you will over-torque that fitting by 14 foot-pounds, or in other words, by about 40%. just say'n
@planesandbikes7353
@planesandbikes7353 Ай бұрын
I should have bought the Aura. I got the Senville Leto and could benefit from the added efficiency of the Aura in the winter. But the Leto still paid for itself in about 2 years, compared to using my oil furnace in Canada where oil is heavily taxed but hydroelectric power is dirt cheap. I have to run the oil furnace about 5 days a year in winter when it drops to like -5C outside, which is not very much oil thankfully. Aura would eliminate the need for the oil furnace altogether. My Leto is 24k, but 28k would have been a better size. I have 9k unit I plan to put in the master suite on solar-battery but honestly the 24k unit heats the whole main floor pretty well on its own, however the cold air does not reach the master suite on hot days in summer (but even in a heat wave our nights are 65F outside)
@michaelmatrongolo7388
@michaelmatrongolo7388 Ай бұрын
Must run a ground conductor back to panel which is bonded to neutral conductor which runs back to original source out in street. Even the ground rod that is used for the service is supplemental in case the neutral is lost
@joshuahughes9860
@joshuahughes9860 Ай бұрын
Need to run a ground wire back to panel.
@FloridaFrank2010
@FloridaFrank2010 Ай бұрын
Love Senville - been using their products for a few years now without issues.
@bigdaddy4975
@bigdaddy4975 Ай бұрын
if you check that ground connection its not really a ground connection thats just a place for lightning to go. it actually needs to be bonded at the main panel just letting you know.
@lannysternburg263
@lannysternburg263 Ай бұрын
DIY HVAC GUY: Tell me you are in Central CA. And I’ll have you do this in our home. Our BEHEMOTH roof mounted HVAC gave up 3 days ago. We already know we’re going with a mini split technology!
@eastcoast186
@eastcoast186 Ай бұрын
The outdoor unit should be elevated off the pad for defrost cycle in the heat mode to let the water run off so you don’t get ice build up and cause damage to the coil when it freezes oops very important info for your diy people
@Watchyn_Yarwood
@Watchyn_Yarwood Ай бұрын
Please do us a favor. I, and others, use extensions in our browsers that do not show those on screen links you point to. Some also use a popular browser that has a built in video player that performs the same. Please included those on screen links you point to in the "more" section. Thanks! By the way, I am in the market for a mini split system and I'm so glad I found your video on this particular brand.
@Jomanscool2
@Jomanscool2 Ай бұрын
Love an install showing the cut and flare steps. Likely going down that route with a 24k Blueridge S5, which seems to be one of the best 10-40F heating performers. Question: do you ever do nitrogen pressure tests? Seems like maybe a best practice to ensure no leaks?
@dmac2890
@dmac2890 Ай бұрын
I like your videos you ever work on Mitsubishi? I was wondering why does the Mitsubishi 24k h2i model MUZ-GS24nahz have such a high cooling and heating capacity compared to other 24k Mitsubishi models?
@zulfiqarahmed8326
@zulfiqarahmed8326 Ай бұрын
EXCELLENT TUTORIAL
@bluejay713
@bluejay713 Ай бұрын
Hi the diy hvac guy i replaced my condenser fan motor ran into a very big problem the fan blade was rusted onto the shaft i had to cut the shaft from the old motor drill a hole in the shaft with a lot of hammering it came out it took me 30 min to get that shaft loose. My condenser runs like new now.
@wanaraz
@wanaraz 25 күн бұрын
Really nice well thought out unit and installation.
@godsblade300S
@godsblade300S Ай бұрын
✌️😜 Always very detailed info, giving even novices hope they can pull it off🤣Thanks Brother 💒⚔️ God Bless us All 🇺🇸🙏✝️
@raybieze
@raybieze Ай бұрын
Did this not come with an insert for the bore you made thru the wall?
@pcho8022
@pcho8022 Ай бұрын
it must have taken a lot of time to film this so I will need to give you a thumbs up just for that. Very informatiive. Pls comment on senville quality vs other industry leaders such as gree, daikin and mitsubishi or are they on another level and shouldn't be compared?
@bulklogan539
@bulklogan539 Ай бұрын
Just installed 150 of them in an upgraded military barracks building at Ft. Stewart GA. Their last AC/heaters were like 40 years old.
@robertgregory2618
@robertgregory2618 Ай бұрын
Only one serious problem with splits that I found was how messed up with fungus and other crap the blower wheels can get. Takes 3-4 years but boy can they get plugged up with stuff, it can even effect the blower out put. They are hard to clean, those blower wheels. They only tell you to clean those simple filters which I found rarely dirty. I still love mine though.
@MeltingRubberZ28
@MeltingRubberZ28 Ай бұрын
They make like a mini pressure washer. Clean it once a year and you're probably OK.
@sailingwiththegods538
@sailingwiththegods538 Ай бұрын
I have a mini split cleaning kit. It's basically a bag that goes over the indoor unit with a drain hose that goes into a bucket. Spray down the entire handler with coil cleaner and spray it out with a pump sprayer. You'll be amazed what comes out of it.
@robertgregory2618
@robertgregory2618 Ай бұрын
@@sailingwiththegods538 Still does not clean as well as taking the blower all the way out and cleaning, which is not easy but is the best way..
@chrissignal8857
@chrissignal8857 24 күн бұрын
Can't even clean the heating elements or AC ducts in our home so this can't be any worse maintenance wise.
@robertgregory2618
@robertgregory2618 24 күн бұрын
@@chrissignal8857 I have lived in my home for 50 years and not once cleaned the ducts. I always changed my filter regularly. These duct cleaning companies are rip offs. But splits collect fungus and mold because of the moisture in the air. I live in Wa. state so more of a problem then a dry climate.
@cgutowski471
@cgutowski471 Ай бұрын
You need a true ground wire back to main panel, not to the actual earth. That will not clear a fault and actually kill someone. This is install is a huge liability. Separately you did not do a nitrogen pressure test for leaks. The system works under pressure and a pressure test will proactively find the issues.
@Egleu1
@Egleu1 Ай бұрын
Yea that's a huge issue. Clearly there's misunderstanding of what a grounding conductor actually does.
@peckerpeter2078
@peckerpeter2078 Ай бұрын
Wouldn’t it be better to Y both sides of the drains so there’s never a drainage problem, heard some rust on inside with only one drain hole used… Also could use pvc for drain with adapter where possible. Corrugated tubing always builds up bacteria, it’s flexible, but definitely not durable and on longer runs that’s definitely not long enough supplied from the factory.
@Time-Trvlr
@Time-Trvlr Ай бұрын
The LETO 12,000 I just purchased and installed did not have a template, the AURA 18,000 I purchased last year did. If I were to turn back my clock I would only buy AURA models.
@aa999xyz
@aa999xyz Ай бұрын
what about a sleeve going to the wall for the line set seemed like that something missing
@MJ-ge6jz
@MJ-ge6jz Ай бұрын
You don't have to remove the Schrader valve. The procedure is still the same.
@HPL5P
@HPL5P Ай бұрын
Thanks for the great explanation. Well done. Did you not have to add refrigerant to make up for the additional head unit/line set?
@swade3485
@swade3485 Ай бұрын
great vid thank you, i gotta do potentially 6-7 of these. What's your thoughts on the nitrogen test? one one hand most company install docs only mention vacuum. (but pioneer on their site does mention pressure testing...just not in the install doc. I also see the point in hey it can check for leaks under pressure, but at the pressure these new refrigerants operate (and that they will likely fail at some point anyways down the road due to that..just common sense) , some say only test at few hundred psi for basic leaks (which i mean is it really a test unless you take it to 475-600 whatever the particular unit runs at) or are you really just risking blowing some nitro past the refrigerant shutoffs. To me if you're not gonna run a test up to 600 or whatever , the question becomes for basic leak checking is a micron test equivalent to a few hundred psi nitro. I also really wonder if you do a full nitro pressure test and it's not in their install docs and they going to blame that when you discover a leak or something.
@RickJ12474
@RickJ12474 Ай бұрын
Love how you clearly did not follow the electrical connection instruction, it's pictured (L-R) Red Black White and you did Red White Black )I know it technically doesn't matter as long as it matches on the other end but if someone comes and repair it in the future, it could cause issue
@matthunter1424
@matthunter1424 Ай бұрын
oh my.. First love the flip flops :-0 second, that THHN was just bare in the wall? No ground? No conduit? No Romex? That really should have been fixed!
@josephpuchel6497
@josephpuchel6497 Ай бұрын
Hey nice video tutorial You said two 30 amp Did you mean two 15 amp fuses ? Nice units I’m going to look into one
@jeffkaloostianii915
@jeffkaloostianii915 Ай бұрын
Next time a digital torque wrench would be the way.
@jkmarshall3553
@jkmarshall3553 Ай бұрын
Awesome video!
@josephchicoski1913
@josephchicoski1913 Ай бұрын
What happens to Mr Cool diy precharged systems in 2025 with new refrigerant requirement?
@rons1566
@rons1566 Ай бұрын
O U T S T A N D I N G !
@samkaplan2482
@samkaplan2482 Ай бұрын
I have a similar layout in my second story of my house. Out of curiosity, is there any reason you didn't put the upstairs headunit where the window A/C was?
@mcd5082
@mcd5082 Ай бұрын
Love these multi zone mini split units
@chrisbennett293
@chrisbennett293 Ай бұрын
Just a correction 😎 @14:34 torque specs are in Nm (Newton Meters), not ft. lbs.
@charlespaine987
@charlespaine987 Ай бұрын
You should install a sleeve through the wall to seal the insulation to stop moisture infiltration into the wall cavity. Filters on those units are piss poor filters. Rock catchers only.
@dewholdingsllc1050
@dewholdingsllc1050 Ай бұрын
I like the safety flip flops in the video. Did you have a link for that?
@michaelcollins5438
@michaelcollins5438 Ай бұрын
Is it possible to mount the head on an interior wall and run the line set down the wall to the basement or crawl space then out to the condenser ? Do you have any videos showing that ?
@shoretrade9516
@shoretrade9516 Ай бұрын
Yes, you can do that. No problem.
@warenmann1042
@warenmann1042 Ай бұрын
@17:31..If you install a fused disconnect make sure you buy an extra couple of fuses and give them to your wife for safe keeping, so that when one or both of the fuses blow at 1AM in the morning on some hot idle Tuesday ten years from now and you realize "there are no stores open on the 4th of July at this time of the morning" all the while thinking "it's been ten years with no problems, how was I suppose to know". As the temperature in the house rises and a sense of doom builds, you shout "it's not my fault, it's not my fault". From the bedroom, in a loud voice, you hear your wife say "if it's the fuses honey, they are in the junk drawer in the kitchen right where I told you I was going to put them oh so long ago, probably all the way in the back by now, I,m going back to sleep, You can thank me later". As she closes her eyes, she smiles to herself and thinks back to that time.."it was such a silly comment, How could they have known"...
@warenmann1042
@warenmann1042 Ай бұрын
@@denverbraughler3948You are correct, There is no reason to use a fused disconnect for this system and, no reason not to, except maybe for cost and/or availability. If you do install this system as shown with a fused disconnect, and forget the extra fuses you will eventually find yourself in a situation similar to the one in my comment which, by the way, was all about the disconnect. (@17:31..If you install a fused disconnect ).. Thank You...
@mickmickers5171
@mickmickers5171 Ай бұрын
Hey bud, wicked videos. I was curious if you have any videos regarding my AC unit continuously running even though it hits the temperature. I have it set to 73, and it constantly runs. It may shit off once every now and then, but for the most part, it's always on
@RJ-cc1fz
@RJ-cc1fz Ай бұрын
My understanding is that it continues to run to remove moisture from the air. It doesn’t continue to run in heat mode
@kangaroogod
@kangaroogod Ай бұрын
The auxiliary ground rod is a bad idea! Wasn’t there an equipment grounding conductor available? If lightning strikes you are intentionally sending voltage up that ground rod, through the home and down the service ground
@bigd3104
@bigd3104 Ай бұрын
Numbered wiring tape is your friend.
@danstojic5643
@danstojic5643 Ай бұрын
Good job Dave, thank you!
@marwansaeed6556
@marwansaeed6556 Ай бұрын
i have a problem with the hvac unit and its not cooling if the fresh air intake is unblocked also some of the other units also wont cool and the contractor will just have them fixed for a week and the problem will happen again
@ak_777-d5k
@ak_777-d5k 14 күн бұрын
What are the dimensions of the styrofoam/concrete pad?
@yalman32
@yalman32 Ай бұрын
decent setup
@jessesmithchannel
@jessesmithchannel Ай бұрын
Does the unit come pre-charged with enough refrigerant for custom line set lengths? I assumed you would need to add more refrigerant for long line sets.
@jonsaircond8520
@jonsaircond8520 22 күн бұрын
These will come with enough refrigerant for up to a specified total line length. For example up to 88 feet so as long as all zones added together do not total 88 feet your good. All mini splits single or multi have a min and max line lengh without having to adjust charge. The Daikin 12k units I install have a min 8ft to max 33ft
@davidw4777
@davidw4777 Ай бұрын
Is that 25ft charge for one line set or all the line sets combined seems like you’d have more than 25ft between both those heads
@TheAndrewWScott
@TheAndrewWScott Ай бұрын
Dude. That install is dangerous. A ground rod cannot be used for EGC (equipment ground conductor) because the earth is not a low impedance path that is needed to clear a ground fault. You need to run a wire back to the panel.
@nrprise
@nrprise 28 күн бұрын
Did the senville come with shrader core removed or was there a reason you removed it as part of install? I installed a single head DIY pioneer unit using almost the exact same steps but my shrader valve failed to close upon removal of my gauges/vacuum pump. Ended up loosing about 20% of refrigerant. Then had to find a tech that would even touch mini splits to recover and recharge to factory spec (since you can't really check charge on these). Had I used a procedure like you did (including the core isolation/removal tool), it would have saved me the cost of tech and recharge. Just wondering where you got idea to remove and re-add shrader valve.
@Katana_00
@Katana_00 21 күн бұрын
No he removed it with the Appion MGAVCR Mega Flow Vacuum Rated Valve Core Removal Tool - 5/16" System Connection
@sc_marauder492
@sc_marauder492 Ай бұрын
Great video!
@wanaraz
@wanaraz 25 күн бұрын
They already are out of this system or discontinued.
@jackjacks5480
@jackjacks5480 Ай бұрын
Senville Aura v Cooper and Hunter Astoria: samething?
@aihf3063
@aihf3063 Ай бұрын
Where did you purchase that micron gauge shut off valve that u connected to the 5/16 appion tool
@shoretrade9516
@shoretrade9516 Ай бұрын
That’s over flaring blockers old school you should not be using them anymore for these high-pressure units. You need to use the ones that machine the flare.
@Time-Trvlr
@Time-Trvlr Ай бұрын
The line sets you were using do not look like the Senville provided product.
@denniszhaunerchyk6191
@denniszhaunerchyk6191 Ай бұрын
You make great reviews. Please create one realworld comparison between R410a, R22 and R32 refrigerant systems.
@mattjudd5275
@mattjudd5275 Ай бұрын
Whats the best universal system for these side discharge inverters ?
@405awhp
@405awhp Ай бұрын
It's not 50 ft/lbs that's way too tight. If you look its referencing newton meters in the manual.
@bobgreenspun1107
@bobgreenspun1107 Ай бұрын
Is it not necessary to pressure test with nitrogen?
@fredost1504
@fredost1504 Ай бұрын
You said massive savings-what did the equipment cost?
@diyhvacguy
@diyhvacguy Ай бұрын
Two grand. Probably what they spend on one year on those electric strip heats in the winter!!
@fredost1504
@fredost1504 Ай бұрын
@@diyhvacguy Thanks for your response: How many tons?
@indicasativa8542
@indicasativa8542 Ай бұрын
Minimum is 500 micron. When i install mini’s I pull them down to double digits…
@Katana_00
@Katana_00 21 күн бұрын
Go smoke
@Hands-onNow
@Hands-onNow Ай бұрын
Can both air handlers run at the same time?
@bgregg55
@bgregg55 Ай бұрын
Yes. But obviously both must be in either heating or cooling mode.
@millyamp2214
@millyamp2214 Ай бұрын
Sir. I followed your link to Amazon for this unit. The description for the unit says: WHAT’S INCLUDED: Includes indoor air handlers, outdoor condenser and installation kit with 16ft. line set and communication wire. Important note: requires professional installation. So it only comes with 16 ft line set. I followed the link on Amazon to the Senville store and they do not list line sets longer than 16 ft. I need a 25 ft and a 35 ft for my application. Ideas? Anyone?
@sailingwiththegods538
@sailingwiththegods538 Ай бұрын
It's only soft copper pipe, any hardware store will have it. You can use regular pipe insulation to insulate it. You can also buy a competitors brand of piping as long as the sizes are the same.
@FlyinFreek
@FlyinFreek Ай бұрын
Would you hold senville over C&H or about the same?
@anthony5530
@anthony5530 27 күн бұрын
Same unit different sticker
@FlyinFreek
@FlyinFreek 27 күн бұрын
@@anthony5530 would Della fall in the same boat? I recall most are made by Midea
@williamserver4332
@williamserver4332 Ай бұрын
Nice install
@jamesalles139
@jamesalles139 Ай бұрын
"Window Unit" oh, the irony, LoL
@charlottecannon314
@charlottecannon314 Ай бұрын
Nice set up. Here's the thing that yanks my chain when installers show up. They don't care how the installation looks. They cut corners. They are not considerate to a customers preferences which all the above should take priority. You see how you looped that electrical wire up on the siding of the House, sticking out like a soar thunb??? Why didnt you run it at from the bottom very low, or just below the house siding, and achor it on tbe concrete foundation, butted against tbe bottom of the siding, then go straight up to tbe electrical junction box??? That's how you should have done it. Not looped around like a Shepard hook running across the house siding, anchoring, and btw, damaging the house siding - to that electrical junction box. Please ask a customer what they'd rather have before you ASSUME they want it like that. Seriousely. It's not rocket science. It's common sense.
@NewmanMG
@NewmanMG 24 күн бұрын
Depends how much the installer is charging which determines how many installs they have to complete by the end of the day. Under valuing ones self undermines the customer in every aspect other than the price tag itself
@bgregg55
@bgregg55 Ай бұрын
Yikes! That is not a legal ground method in any US jurisdiction.
@Katana_00
@Katana_00 21 күн бұрын
You poor thing.
@stoveguy2133
@stoveguy2133 Ай бұрын
Natural gas heat is cheaper
@thomasmeadows256
@thomasmeadows256 Ай бұрын
@therealdheel8177
@therealdheel8177 Ай бұрын
They have no built in em heat. Getting a heat pump mini split, it gets anywhere under 35 degrees is a waste of money if you want to heat with it. Your condenser outside will just freeze up, making the unit throw an error code an stop working. They are great for cooling. Garbage for heating anywhere it gets really cold. Which is why you dont see heat pump units up north. Unless they are duel fuels using a gas furnace as em heat instead of electric heat
@cgutowski471
@cgutowski471 Ай бұрын
Disagree. I have a Senville 24k Aura installed in a high elevation cabin. It gets to below -10°F and still heated efficiently this past winter. Power usage was 1/2 of what the electric baseboards have been in previous years. The Aura has a pan heater to remove any ice buildup around the bottom of condensing unit. Works great.
@planesandbikes7353
@planesandbikes7353 Ай бұрын
The Leto range will struggle below freezing, but the Aura can handle really cold temps and keep heating with OK efficiency. Now if you mean actually really cold - like -30C or below 0F like it can get on the northern prairies, then you probably are a candidate for a dual fuel central HVAC or just have your old gas/electric/oil furnace for backup to the ductless, or just some baseboard heaters for those ultra cold nights.
@sailingwiththegods538
@sailingwiththegods538 Ай бұрын
I live in NY and use my 5 year old Aura all winter and it heats perfectly fine down to 0F, and falls off below that. The condensers don't freeze up, when the coils get iced over the unit runs the cooling cycle for a minute or two to force heat into the condenser to melt the ice, and a pan heater. It only freezes up around 20-30f, when it gets below 20 it doesn't freeze up much. There are A LOT of mini splits being used up north, I don't know where you heard they're not. We do need supplemental heat when it gets below zero but that's not a surprise. I went from 6 cords of firewood down to 1 and the mini split costs less to heat compared to firewood too.
@drewberrynews3875
@drewberrynews3875 Ай бұрын
At the end of the video, he says, "Hey alexa". I lost all interest in this product.
@paullehto2294
@paullehto2294 20 күн бұрын
I’m a builder in ct. I used these in every home with no issues after having problem with Mitsubishi u its
@Ivansgarage
@Ivansgarage Ай бұрын
The thing that bothers me is R410A it's expensive and gonna be phased out... they the (environmental morons) have totally screwed up air-conditioning and refrigeration... and yes I have a mini-split on my house, R410A, I would of paid double to have a R22 system.. I did AC/Ref.. work for thirty years...
@sc_marauder492
@sc_marauder492 Ай бұрын
Yup. Everything the Left touches, they destroy!
@davidryan173
@davidryan173 Ай бұрын
please lose the adjustable wrenches
@munozinni
@munozinni Ай бұрын
Hola 👋 señor Dave!!! That was a great video very informative and educational and the best of all was that you showed the process of the installation …You are the best in A/C keep up the great work and content…You have a great day and weekend…Saludos!!!! 👋😃👋
Convert Your Window AC Unit To A High Efficiency MINI SPLIT!
18:30
The DIY HVAC Guy
Рет қаралды 13 М.
Is DIY'ing Your HVAC A Good Idea?
38:25
The DIY HVAC Guy
Рет қаралды 45 М.
Nurse's Mission: Bringing Joy to Young Lives #shorts
00:17
Fabiosa Stories
Рет қаралды 13 МЛН
Cute kitty gadgets 💛
00:24
TheSoul Music Family
Рет қаралды 21 МЛН
小丑和白天使的比试。#天使 #小丑 #超人不会飞
00:51
超人不会飞
Рет қаралды 32 МЛН
At the end of the video, deadpool did this #harleyquinn #deadpool3 #wolverin #shorts
00:15
Anastasyia Prichinina. Actress. Cosplayer.
Рет қаралды 15 МЛН
#1 Reason Why DUCTLESS Units Fail | How I Fix It...
13:59
Quality HVACR
Рет қаралды 816 М.
A $600 Ductless 110v Mini Split?!
32:38
The DIY HVAC Guy
Рет қаралды 580 М.
The Top 7 Things AC Companies Don't Want You To Know How To Do!
17:29
Watch This Before You Buy a Mr Cool Mini Split
35:24
LRN2DIY
Рет қаралды 217 М.
How To Relocate A MrCool DIY Mini Split Condenser
18:54
The DIY HVAC Guy
Рет қаралды 10 М.
3 PROVEN Methods To Getting Colder Air From HVAC Vents.
10:45
The DIY HVAC Guy
Рет қаралды 674 М.
Contractors Hate Me For Showing You This!
24:20
HAXMAN
Рет қаралды 1,4 МЛН
DIY Central Air Install for $3300 (Including Tools!)
40:43
LRN2DIY
Рет қаралды 352 М.
Nurse's Mission: Bringing Joy to Young Lives #shorts
00:17
Fabiosa Stories
Рет қаралды 13 МЛН