I am already professional in HVAC, I really appreciate for suchlike informative and fruitful explanation for all those whose are in this field. Welldone. Keep continue likewise.
@michaelhartsgrove30592 ай бұрын
This is a great video, newly promoted HVAC tech, worked as welder fabricator/ industrial maintenance mechanic. Boss said wanna be the new HVAC tech?…. Lol 😂… only this year installed my first system on the wife’s car successfully… guess I’m qualified. Currently studying for the EPA 608 exam. Thanks guys very helpful.
@MechanicalPros2 ай бұрын
Congratulations! Glad we could help :)
@garypoplin45992 ай бұрын
Hope you had your 609 before that!
@gotchaplumberАй бұрын
Could you do video of taking wet bulb measurements with tool?
@riadhch5643 Жыл бұрын
Thank you for sharing that much of very beneficial information accept my respects
@nanoglz Жыл бұрын
Great information very well explained 👏
@10speed4 Жыл бұрын
That made since to me and I know very little about super heat.
@shannonedwards1872 Жыл бұрын
What's so funny about a wet bulb.. I feel like I missed something... ☺ Thanks, guys! Love to see you both having fun doing these videos.
@gotchaplumberАй бұрын
Thank you!
@harbbains5718 Жыл бұрын
Excellent video… great job guys!!!
@corruptedbrain68 ай бұрын
What I learned from this video is that alot of installs do not install the piston so now it makes sense why I have been seeing super heat 1 degree and subcool 2 degrees
@spydermaaaan4 ай бұрын
Very clear Thank you!!
@andys52034 ай бұрын
Great video. Do you have to shut the condenser off to check the wet bulb? Thks
@eduardocastroisaac1630 Жыл бұрын
Thanks for this kindly video explanation. Saludos desde Mérida Yucatán México
@MechanicalPros Жыл бұрын
Gracias, mis amigos de Yucatán, México. Su apoyo es muy apreciado.
@JacekWrona-s1v2 ай бұрын
Great informational video. I hope you can help me. I have 14 seer evaporator coil and 15 seer Carrier condenser (no matching system .I know that) There was original piston (0.088) in the unit ,but after the Carrier condenser was install, piston was replaced by TXV. Unfortunately ,randomly compressor is overheating , so I planning to put the piston back . And new piston is 0.090. What's your take on that?
@DG-Chiefs-fan5 ай бұрын
I’m very new at HVAC and this helps me understand better. Great video thanks from all of the newer people getting into the trade 👍🏽
@robavis4906 Жыл бұрын
thank you guys. Ive been looking to learn more about this type of stuff.
@MechanicalPros Жыл бұрын
More to come! Thank you for the support.
@brianmcdermott24306 ай бұрын
Great info. Thank you , Craig
@davidmclain7756 Жыл бұрын
Great video. Very detailed. I do have a question on the indoor wet bulb temp reading. Is it correct to take the wet bulb temp inside the home at the return grill if the evap coil is in the attic? Or do you need to take the wet bulb reading up in the attic inside the unit case before the return air hits the evap coil? Thanks
@Lemonades13216 ай бұрын
Wow awesome explanation. Thank you.
@daviderquitt16422 ай бұрын
My data sheet is located inside unit so should I go buy it ..410a system
@chadgriffith58193 ай бұрын
So my 4 ton package unit has the piston. It’s running my shop. I bought it used. I’m getting a 15-20 delta T but pressures are 155/470. Ambient is 95 and wet bulb about 77 using wet rag and prob. Suction temp is 80. So I think target is 30 and actual super heat is 30. Im I good or missing something. Suction stops sweating around noon.
@mr.18s73 Жыл бұрын
I needed this information 😅
@MechanicalPros Жыл бұрын
Nice!
@j.t.johnston30483 ай бұрын
If there is no piston installed at all, there is no expansion device and thus no refrigeration will occur. Inhave never seen a system with no piston installed. The indoor unit will usually already have something installed.
@kylebell78794 ай бұрын
Is that temp chart valid for r12?
@Saabjock6 ай бұрын
Can an R22 system with an original piston-type expander be converted to TXV when a new evaporator is installed?
@realSamAndrew4 ай бұрын
Yes. You just need to make sure you have the right TXV that's made for your air handler and made to work with R22.
@thembones12 Жыл бұрын
I want to see the real/actual pressure & temperature that is the system should be running. Take some readings and measure the superheat!
@2bnax7 ай бұрын
THE CLARITY OF THE EXAMPLE SUFFICES. YOUR UNIT PRESSURES WILL LIKELY NOT BE THE SAME AS HIS ANYWAY. APPLY THE PRINCIPLES - THAT'S WHAT'S IMPORTANT. THE REFERENCE NUMBERS USED WERE CORROLATING TEMP. / PRESS. AS THEY ARE ON THE CHART. THEY HAVE SHOWN YOU HOW - DON'T BE AFRAID THANKS FELLOWS!!!
@dachee7 ай бұрын
If I am not wrong, not all expansion valves are located at the evaporator.
@realSamAndrew4 ай бұрын
Yes they are, unless you have a heat pump which has them at both the condenser and evaporator, or you have a mini split system that can locate at various places.
@lwh73014 ай бұрын
Seems like every video like this glosses over the most important point of figuring when to add/subtract refrigerant in a few seconds, and then takes a minute talking about cleaning the filter.