Total Superheat Method used to Check the Refrigerant Charge of AC's with a Fixed Orifice

  Рет қаралды 130,788

AC Service Tech LLC

AC Service Tech LLC

Күн бұрын

In this HVAC Service Training Video, I explain Step By Step How to Check the Refrigerant Charge using the Total Superheat Method for Systems with a Fixed Orifice such as a Capillary Tube or Piston Metering Device. I show how to Find the Target Superheat using a Target Superheat Chart and how to know if the Unit is Low on Refrigerant Undercharged or Overcharged. Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety. Make sure that you are EPA 608 certified before handling refrigerants!
Tools Used In The Video
Fieldpiece SDP2 Digital Psychrometer - amzn.to/2nniMVR
Wet Bulb Temp Sensor - amzn.to/346iFB4
General Tool Digital Psychrometer - amzn.to/2UxKxe8
Amprobe Digital Psychrometer - amzn.to/2yim7fR
Sling Psychrometer - amzn.to/2JwYtyQ
Quick Card with Target Superheat Chart - www.acservicetech.com/store
ST4 Dual Temp Meter - amzn.to/3dNHFkY
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos/Articles
• Should You Use Superhe...
• Check the Air Conditio...
• Checking the Refrigera...
• Superheat Charging Cha...
• Check the Refrigerant ...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicetech.com/store
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicetech.com/hvac-ca...
Our Newest Articles: www.acservicetech.com/articles
Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
Our Other Resources: www.acservicetech.com/resources
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicetech.com/tools
Our Tool List on Amazon: www.amazon.com/shop/acservice...
Support the Channel by purchasing tools through TruTech Tools!
Use this link www.trutechtools.com/?aff=8
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.com/show/74KXLz5...
Apple Podcasts: podcasts.apple.com/us/podcast...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided. ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #superheat #subcooling #capillarytube #meteringdevice #refrigerant #orifice
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Пікірлер: 149
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
The E-Book and Paperback at our Website: www.acservicetech.com/the-book The Paperback at Amazon: www.amazon.com/shop/acservicetech Support the Channel- www.patreon.com/acservicetech Tool List- www.amazon.com/shop/acservicetech For those that are looking for the tools used in the videos: (Linked Below) Ratcheting Service Wrench amzn.to/2dGV4Nh Yellow Jacket Sealright 90 Coupler- amzn.to/2LsU1V7 Yellow Jacket 1pk Compact Ball Valve- amzn.to/2uXdF18 Yellow Jacket 3pk Compact Ball Valve- amzn.to/2AiKfQe Yellow Jacket Refrigerant Gauge Set amzn.to/2aenwTq Refrigerant hoses with valves amzn.to/2aBumVI Yellow Jacket Gauge set & hoses amzn.to/2vLVkV9 Yellow Jacket 4 Port Manifold w Hoses amzn.to/2BkuGIq Digital Refrigerant Scale amzn.to/2b9oXYl Ratcheting Service Wrench amzn.to/2dGV4Nh Accutrak VPE Ultrasonic Leak Detector amzn.to/2nFYKVe Accutrak VPE-GN Ultrasonic Leak Detector amzn.to/2Zy4IZP FieldpieceSMAN360 Digital Manifold Set amzn.to/2BdoaD4 FieldpieceSMAN460 Digital Manifold Set amzn.to/2nB4Fe6 Ultrasonic Leak Detector with Headphones- amzn.to/2B2cRO3 Compact Ball Valve for Refrigerant Hose amzn.to/2KUisW8 QuickDisconnect 90 for refrigerant hose amzn.to/2MMtVcg JB 6 CFM Vacuum Pump amzn.to/2nqbvo8 Appion Blue 3/8" to 1/4" Vacuum Hose amzn.to/2uYlVyc Appion Red 3/8" to 1/4" Vacuum Hose amzn.to/2uYg6Ro Appion Valve Core Removal Tool amzn.to/2uYr8WL Yellow Jacket 1/4" by 1/4" hose amzn.to/2umtcod CPS Vacuum Micron Gauge amzn.to/2v1nM3O Supco Vacuum Micron Gauge amzn.to/2v1JRiA RectorSeal Bubble Gas Leak Detector amzn.to/2ckWACn Magnet Jumpers- amzn.to/2PyKPQZ Alligator Jumpers- amzn.to/2PxqJXn Fieldpiece ST4 Dual Temp Meter amzn.to/2wc1ME3 Fieldpiece Bead K Type Temp Sensor amzn.to/2DBwKfs Fieldpiece Wet Bulb Temp Sensor amzn.to/2RRI7Tw Fieldpiece TC24 Temp Clamp amzn.to/2qHLyjZ UEI DL389 Multimeter amzn.to/2xAdaJf Thumb Screw Valve Core Depressor with Backseat- amzn.to/2mR0sCL UEI DL479 Multimeter with temp sensor amzn.to/2jtsUbJ Air Acetylene Torch setup amzn.to/2aQalsb 15% Silver Brazing Rods amzn.to/2gVLyLc Yellow Jacket Flaring Tool - amzn.to/2OBxGlM Yellow Jacket Flaring Tool with Set Depth - amzn.to/2QIKsQH Yellow Jacket Torques Wrench - amzn.to/2NRR68Q Nylog - amzn.to/2MLJcch Ridgid Tubing Cutter - amzn.to/2DnjjR1 Wolverine Tube Reamer - amzn.to/2QGLyMV Nitrogen Regulator- amzn.to/2bXdR5f Uniweld NitroVue Flow Regulator- amzn.to/2GnsaAo Uniweld Nitrogen Flow Meter amzn.to/2brvoBg Air Acetylene Torch setup- amzn.to/2aQalsb 15% Silver Brazing Rods- amzn.to/2gVLyLc Uniweld Cap-N-Hook and #2 Tip Oxy Acetylene Torch Setup- amzn.to/2STp3Fe Ameriflame Oxy Acetylene Torch Setup #1 &#2 Tip- amzn.to/2SRm3JF #2 Tip for Oxy Acetylene Torch- amzn.to/2SPDaeD Cap-N-Hook Tip for Oxy Acetylene Setup- amzn.to/2MbhpUk Appion Valve Core Removal Tool amzn.to/2uYr8WL RectorSeal Bubble Gas Leak Detector - amzn.to/2ckWACn 25 Valve Cores - amzn.to/2L37UJU 25 ¼” Brass Port Caps with rubber O-rings - amzn.to/2GIOdD2 Brass Valve Core Tool which holds 3 valve cores - amzn.to/2GFEbm2 Valve Core Torque Wrench - amzn.to/2GHiLoD Locking Cap Universal Lock/Unlock Tool - amzn.to/2GGAoVp Locking caps - amzn.to/2GFXZ8A Nitrogen Regulator amzn.to/2bXdR5f Nitrogen Flow Meter amzn.to/2brvoBg Other tool links can be found in the video description section. Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal- www.amazon.com/shop/acservicetech
@David-ik6yu
@David-ik6yu 3 жыл бұрын
Very hard to find an AC company today with "experience, pride, and ownership". Five companies out to date, lots of money spent on service calls and still not functioning as designed. I learned HVAC in the military (long time ago). Back to school I go. Your videos are very helpful. I have ordered the book and workbook as well and look forward to them both. Hopefully, I can find what no one else seems to be able to.
@janwerner6882
@janwerner6882 4 жыл бұрын
i was 90% sure i had a piston/orifice because i saw the nut but i wasnt able to confirm by looking behind the panel because its proving to be a real hassle getting it off..its like the panel is also connected to a bracket that also holds the evap coil..so i feel like i need 2 people..whole units going to need replacing anyway..so thanks for the info! really love your vids..i have like 30 in a playlist that i watch for hours on my study days
@johndoe-wt4ui
@johndoe-wt4ui 4 жыл бұрын
Very clear information thank you sir u r the master
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Glad you enjoyed the video John!
@danielwright3754
@danielwright3754 4 жыл бұрын
Thank you guys, I will get the book.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks Daniel and let me know what you think of it after reading it, thanks!
@robertl.7657
@robertl.7657 4 жыл бұрын
When are you doing boot camps, ??? In Texas we need real Pros like you, the way you explain, teach, is very sharp, accurate!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
I usually wait until a company contacts and wants to bring me in for a one or two day training event. I need the organization to have the equipment, location, and techs ready for the training event and for the funding for such an event. Thanks for your comment! I also don't love travelling since I have young kids and trying to be a good father and husband so this is the main way I reach techs!
@scottjones7279
@scottjones7279 4 жыл бұрын
Thank you for all of your and sharing your knowledge
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Glad to help Scott!
@petesingh292
@petesingh292 4 жыл бұрын
Thank you for quick response just ordered one
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks Pete!
@AliBaba-cf4iu
@AliBaba-cf4iu 4 жыл бұрын
Mr. excellent..... video, I'm sure this way is a little bit easier on u and faster don't have to hook up all the equipment to show the same illustration, also you actually show more in less time, thanks again I'll be buying one of those books
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks a lot Ali Baba, the work on the front end is less but the back end is much more on these videos, thanks!
@deanmartin1966
@deanmartin1966 4 жыл бұрын
Great explanation. Like how you show that the superheat is a moving number. That's why I always check the superheat again after adding or remvoing refrigerant.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Absolutely, thanks!
@jorgebueno737
@jorgebueno737 4 жыл бұрын
excellent videos, put out some new stuff...i always look for the latest videos, haven't seen any new stuff yet..
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
What type of content are you referring to and desiring to see?
@hvactech5829
@hvactech5829 3 жыл бұрын
I already bought your ebook, you changed my world man !! Thank you !
@Craig1967
@Craig1967 4 жыл бұрын
By the way, great videos - and thanks for everything you do. I am going to order your book right now.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks a lot Craig!
@publicmail2
@publicmail2 4 жыл бұрын
This is the best, so many hacks out there SP's >.2 over under charged systems, duct leaks, cost an xtra 1k year in kwh cost.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
You need to be educated for sure, thanks AD!
@erickguzman2932
@erickguzman2932 4 жыл бұрын
Thanks for all the knowledge shared. I've purchased both cant wait to get my hard copy.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks and let me know what you think of the book after reading it!
@juanacosta2788
@juanacosta2788 4 жыл бұрын
Going to get you're ebook and service book
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks and please let me know what you think of it after reading, thanks!
@slideoff1
@slideoff1 4 жыл бұрын
Love your videos.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks a lot Yo-Pops!
@watermanone7567
@watermanone7567 4 жыл бұрын
I really like your video's. I learned the old school way and the tools and information is way better today. Many thanks for the great video's.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks a lot Waterman!
@Jeff_Seely
@Jeff_Seely 2 жыл бұрын
I came across your refrigeration educational series when I did a search for understanding the basics. Here you provide an easy-to-understand representation of saturation and how it relates to a particular refrigerant type. I had no idea of this concept until watched this video and nearly all of my questions were answered for saturation. This is excellent for a newbie like me! Thank You!!!
@jericosha2842
@jericosha2842 3 жыл бұрын
seems like most people don't even bother with wet/dry bulb and just derive superheat from guages and temp of outside suction line... great video, thank you. I want to do it right.
@Climatecontroldoneright
@Climatecontroldoneright 9 ай бұрын
Great video
@donnierobertson3088
@donnierobertson3088 3 жыл бұрын
Great job and video
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad you enjoyed it
@marvinostman522
@marvinostman522 4 жыл бұрын
I am glad you mentioned the point about taking away refresh every time you put your gauges on a system. There are ways to minimize the loss but there will still be a loss. You can tell a lot of things without putting gauges on. After hooking gauges every visit you can end up with like you said possibly a low charge. Due diligence says you should try to find the leak but there may not be a leak but when you need to add refrigerant it throws the homeowner into panic mode. OMG I have a leak!!!!!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
You are right for sure, thanks Marvin!
@leonardkeitt9801
@leonardkeitt9801 3 жыл бұрын
Thx Craig I'm really enjoying your Hvac videos,Service bk,Work bk as well as your three Quick guides templates. Do u hv any plans for heat systems (Books)? thanks again!
@elmahjoubmeddah5725
@elmahjoubmeddah5725 4 жыл бұрын
You're the best man 👌
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
I appreciate that!
@robertl.7657
@robertl.7657 4 жыл бұрын
Start Thinking on doing one book, for basics, there some out there but they are like puzzles, like they don't have clear scenarios, or context, hope you do one day,!!!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Hey Silver Shark, I mention the troubleshooting in this book but the beginning chapters are for beginners. The content in this book is exactly what I would teach a new student to bring the tech from nothing to troubleshooting. Remember this is 229 pages long and the EPA 608 is integrated in the book, thanks!
@coldfinger459sub0
@coldfinger459sub0 4 жыл бұрын
Like your videos always watch them when you release a new one. Just realized when you mentioned having to walk back in the building and then back outside again to check your wet bulb and your dry bulb. all temperatures as they change waste a lot of time and Time is money. Highly recommend Fieldpiece wireless gauges with the measure quick app. Or at least the Fieldpiece app. When every minute from morning to night is billable hours and every day you have more work than you can possibly get done. Those few minutes wasted on every job walking in and out of the building add up by the end of the day and that could be one lost job every day in wasted time just to check measurements when it could’ve been done through Bluetooth gauges and you never had to stand up once to go check another gauge. At $150-$200 plus an hour That could add up to one lost job every day for the entire year. That adds up to the total price of a new service van or service truck just by losing that one daily hour. Think about it
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
I agree, have you checked out my total superheat video using the SMAN 460 and wireless wb sensor and wireless outdoor temp reader to automatically calculate target superheat. I also did a video using the probe set, thanks!
@zekenzy6486
@zekenzy6486 4 жыл бұрын
thank you for shared
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks ZE!
@silvioatejedor
@silvioatejedor 4 жыл бұрын
You mentioned before that having to much superheat is an indication of a bad TXV or a restriction in the line so having high sub cooling is the same indication ? Thanks for your help and happy new year
@jimbola77
@jimbola77 4 жыл бұрын
thank's partner for sharing!!!!!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Glad to help Jimbola77!
@robertl.7657
@robertl.7657 4 жыл бұрын
Very Good video, !!! Very explicit, very pro, technical, and I like the computer screen for clear example, you getting better!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks Silver Shark, glad you enjoyed this layout!
@1shagg420
@1shagg420 3 жыл бұрын
Total superheat is a massive pain in the ass. Thank God almost everything is TXV these days. But this cleared a lot up for me and I've been doing this for 10 years.
@MrSprintcat
@MrSprintcat 4 жыл бұрын
Thanks for the video. It would b nice if there was a cheat sheet. Kind of like a pt chart
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
I think that is how all of those false rules of thumbs were created by trying to find a short cut but really we need to see that superheat and subcooling to tell how the system charge is doing but I agree it would be nice, thanks!
@robindenbeste5472
@robindenbeste5472 2 жыл бұрын
Thank you.
@acservicetechchannel
@acservicetechchannel 2 жыл бұрын
You're welcome!
@douglieberman6406
@douglieberman6406 Жыл бұрын
Thanks!
@acservicetechchannel
@acservicetechchannel Жыл бұрын
Thank you very much Doug!!!
@audreymeyer5616
@audreymeyer5616 2 күн бұрын
This is interesting
@user-kt2hb8xr3p
@user-kt2hb8xr3p 4 жыл бұрын
عمل رائع اتمنى لك النجاح
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
شكرا جزيلا!
@justintimber5058
@justintimber5058 4 жыл бұрын
I love this channel. You are explaining very clearly. One question: Can I use a standard digital temperature reader to measure the inside (WB) temperature? Sure this will not the correct temperature, but I can get only a standard digital temperature reader in this country. Can I do anything to bring it to a WB value? Thanks a lot!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
You can add a small wet sock over the temp sensor to measure the wb temp, thanks
@shawnrender6935
@shawnrender6935 4 жыл бұрын
Do you have a video on using the anemometer ?
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Not to date but I would like to do some airflow videos in the future, thanks!
@ericksanabria168
@ericksanabria168 4 жыл бұрын
Is there a video on the temperature rise method to set air flow, in cooling and hearing mode, will there be a book for furnaces as well ?
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
I am planning on doing a video on temp rise to determine airflow. I would love to do a furnace book but I have a few other resources to build before that, thanks!
@ericksanabria168
@ericksanabria168 4 жыл бұрын
AC Service Tech LLC that’s awesome, will definitely keep a look out for the book, also you think you would be doing any videos on communicating ??
@ThermalSolutionsHVACR
@ThermalSolutionsHVACR 3 жыл бұрын
For wet bulb temp, Essentially, Digital psychrometer as close as you can to the evaporator coil? If you got to drill a small 3/8s holes, as long as you get your psychrometer as close to the evaporator coil, correct? Thank you your videos are incredibly well put together!!
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
You should stay back a little bit if possible anywhere 6 inches to 2ft upstream of the coil or the psychrometer will measure a higher wb if its right next to the evap coil, thanks
@jeffwang2012
@jeffwang2012 4 жыл бұрын
Hi, i bought E-Book few months ago and i really like it, now i'm thinking to get paperback version. My question is: will you ship it to canada ? and what's the shipping cost? thanks!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Hey Jeff, yes we ship to Canada fairly frequently for paperback purchases on our website www.acservicetech.com/store and there is an international automatic shipping calculator there once you enter your address. Any questions, just email me at info@acservicetech.com thanks!
@kennethlobo4420
@kennethlobo4420 4 жыл бұрын
Thanks for the video,have really learned a lot and gained much knowledge.Hope you could do one on where the airflow of an indoor coil/or an air handling unit.using an avenometre could be demonstrated. Regards from India. Am in the process of buying ur book.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks Kenneth, I would like to do some airflow examples in the future, thanks!
@anthonysandoval965
@anthonysandoval965 3 жыл бұрын
Wheres your vaporizer Lol jk 🤣 Your the man I love all your tutorials!!
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Yeah Yeah, ha ha. That was a good one! Thanks Anthony!!!
@lancerudy9934
@lancerudy9934 4 жыл бұрын
Can you do a video a cfm at the supply registers in the house?!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
I certainly would like to do one in the future, thanks for the reminder Lance!
@khairunnajmi5995
@khairunnajmi5995 3 жыл бұрын
Hi, can i use this method for residential split unit ductless system?
@fromanabe8639
@fromanabe8639 2 жыл бұрын
How can you tell what type of metering device your A/C has without removing the evaporator coil? My evap coil was installed by some earlier company or service tech. There are only two small holes in the plenum and they're filled with putty. I don't want to unsolder the evap coil just to see what kind it is.
@Xbreaselx
@Xbreaselx 4 жыл бұрын
How long do you recommend placing your wet bulb in airflow to get an accurate reading?
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
It doesn't take very long, usually 30 seconds to 1 minute per reading just until it stabilizes, thanks!
@Jeff_Seely
@Jeff_Seely 2 жыл бұрын
You know I really had no idea about these procedures and practices such as the superheat and subcooling methods. I was it interested in what I could do to make my refrigeration system cooler and more efficient. Well now I'm hooked on desire to learn more and you certainly cover a lot of information in a easy way to follow along! So before this highly scientific method, how did the technician determine whether or not the system was properly charged? Thank you for the great video!
@ryanarendt8927
@ryanarendt8927 4 жыл бұрын
Ok, kind of in depth question about having high head pressure on a 2.5 ton split system with 22. My suction is 84 liquid is 94 degrees. My total sub is 43 and super is 43. I have ran down all the troubleshooting in your book and cant seem to find the culprit. Did pump down and checked the orfice, purged with nitrogen and if it was under charged my sub would be over 25.. I can give link to my fieldpiece check and charge and manifold data l9gger
@BartSimpson-nr1dy
@BartSimpson-nr1dy 4 жыл бұрын
Have a quick question. Does your book go into the diagnostics of 2 stage condensing units? Or how to differentiate wiring of a 2 stage versus a single stage? I noticed in one of your tutorials about furnace and thermostat wiring, you have no explanation about Y1 and Y2 wiring. Would be nice if ducting and manual D are explained in your new book. That I’m guessing is not in the book?
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
This book is 229 pages and focuses on refrigerants and procedures used to prepare a system for refrigerant, how the systems work, charging, troubleshooting, and airflow testing. The entire outline including sections and subsections are found at the website. This one is not about the electrical wiring. Those wiring diagrams were just focusing on single speed units and units that control speeds at the control board such as for heating, thanks!
@BartSimpson-nr1dy
@BartSimpson-nr1dy 4 жыл бұрын
AC Service Tech LLC - never ever a criticism of your videos or instruction. Just a shame since you are such a great teacher to exclude those important aspects of HVAC. Maybe in your next book. Until then, thanks for all your hard work.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
@@BartSimpson-nr1dy I had to stop somewhere and 229 pages is considerable as it is, otherwise I would never had completed it. That was a 3 year project. We are working on the workbook now for schools for this book, thanks!
@johnnyriser8519
@johnnyriser8519 4 жыл бұрын
I always enjoy your videos. They are very detailed and informative. Keep up the good work. Once superheat or subcooling is adjusted, and the job is completed, is there a need to recheck the superheat or subcooling at a later date if there is no system leak? Put another way, once superheat or subcooling is adjusted, will it always fall within the superheat/subcooling chart readings if the gauges are later placed on the unit to check pressures? Thanks.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Yes they should remain good unless there is a leak, thanks!
@tttota5421
@tttota5421 Жыл бұрын
Good job I got a question for you, if you see this and you reply I would appreciate it . There is a 3 ton heat pump ,with a 14inch round duck and 6vents ,and 20/20 return grill it’s a commercial place , I got DT 26 76F return and 50F supply air Low side pasig it’s 125, line temp it’s 42 degree S.H it’s 11 High side it’s 300 psig line temp 95 degree F. S.C it’s 4,3 And it’s with a piston not Txv. Personally I think there it’s small duck size and not enough vents ,what’s your thought on this ?
@erwinelarcosa8917
@erwinelarcosa8917 2 жыл бұрын
The superheat of HBP and LBP are the same ? Can i use the target superheat chart in LBP ?
@aprovleptos85
@aprovleptos85 Жыл бұрын
Great video, but i cannot understand what is the right pressure when machinr is on
@sergiomansilla
@sergiomansilla 4 жыл бұрын
Excelente video !!! Book versión español ?gracias saludos
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Sergio, we don't have the book translated yet but we are planning to in the future, thanks!
@sergiomansilla
@sergiomansilla 4 жыл бұрын
@@acservicetechchannel Good, once it gets fully transladed i'm planning on buying it. Cheers!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
We now have a Spanish version Ebook www.acservicetech.com
@sergiomansilla
@sergiomansilla 4 жыл бұрын
@@acservicetechchannel excelente, ya lo compre ,muchas gracias por la vercion en español
@petesingh292
@petesingh292 4 жыл бұрын
Can I use regular thermometer to find the wet bulb temp and dry bulb temperature?
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
You should use a digital temp meter such as the st4 for dry bulb temp readings. Wet bulb can be taken with a psychrometer or a method discussed in this video. There is a temp sensor with a cloth over it for sale in the store at www.amazon.com/shop/acservicetech thanks! nnkzbin.info/www/bejne/hnq8e3WXhMl6rpY
@Faith0929ROK
@Faith0929ROK 10 ай бұрын
This guy is a life saver for newbies. I had a hvac technician he said I had 32 degrees of superheat at the low side line and that was way off. I have piston 25 year old Trane X1200 metered system. I told him about the wet bulb, dry bulb method and he was confused.
@raymondcoleman6140
@raymondcoleman6140 4 жыл бұрын
May I ask a question, if vapor pumps can’t compress liquid....why charge equipment in the liquid form? Meaning We charge 410 or puron equipment in liquid
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
This is to keep the 50% 50% mixture of R-410a consistent as it leaves the bottle. plus we can meter it in slowly so the refrigerant has a chance to flash before it goes in. R-410A is made up of R-125 and R-32 thanks!
@jerm5772
@jerm5772 4 жыл бұрын
Can the instructions and principles in this video apply to an R22 system?
@stevee7774
@stevee7774 4 жыл бұрын
Yes, any refrigerant.
@raymondcoleman6140
@raymondcoleman6140 4 жыл бұрын
Make sure all dampers and registers are open, as well as nothing blocking the return grilles
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Yes absolutely, thanks!
@dylandrymond3951
@dylandrymond3951 4 жыл бұрын
Good morning Craig. In reference to air flow, what do you think of the way "emerson check a charge" recommends checking air flow? They take indoor dry-bulb inlet, wet- bulb, and indoor dry-bulb outlet to calculate air flow. Your thoughts? Thanks again for your hard work. Praise God.
@deanmartin1966
@deanmartin1966 4 жыл бұрын
I use the same app. I like it to double check myself. Its a good way to check for correct airflow without an anemometer
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Hey Dylan and Deanmmartin, that would be depending on the refrigerant charge being accurate before checking airflow but we are usually trying to verify correct airflow before running the the refrigerant through in order to check the charge. It is nice though and thanks for bringing that up Dylan. may the Lord Bless you both, thanks a lot!
@Spencerbuildsit
@Spencerbuildsit 4 жыл бұрын
simple question, but not mentioned. when sampling indoor WB temp. with fan running or not? static temp vs. a wind chill effect.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Wb temp is while the unit is running so that you know the target superheat at the same time that you are measuring your actual total superheat, thanks!
@Spencerbuildsit
@Spencerbuildsit 4 жыл бұрын
Hmm. Thanks for the reply. I'll read up on WB. I get that it's to be taken as close to the same time a s possible. Also it measures the airs capacity to absorb moisture. But wouldn't it give a different reading depending on the velocity of the air? Higher velocity = faster evaporation. Also, as the saturation is occurring in a closed system with no direct contact with house air, why is it relevant? Cool temperature to condense maximum latent heat?
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
@@Spencerbuildsit A high wb temp air crossing the evap coil is a higher heat load for the refrigerant to absorb since the coil is meant to condense and then reject the condensate out of the building as well as for the refrigerant to move heat out of the building. This work is done to reduce the humidity and while this is happening you will see a lower delta t especially in the case of a fixed orifice. The delta t is low because the superheat is high due to the added humidity that is getting condensed. thanks!
@Spencerbuildsit
@Spencerbuildsit 4 жыл бұрын
Got it! So the calculated SH takes the latent heat into account. Wondering why leave any SH on the table? How about minimizing the SH, then have a liquid sensor that returns liquid to the top of the evaporator, or a small evaporator, as a anti slugging device? How about using flat plate heat exchangers as evaporator in air to water heat exchangers? I have one that is useless as it needs a control board. DC inverted driven air to water heat pump. Haven't found much info. Learning so much from your contributions. Thank you. Will you be doing a few videos on design? Air handler selection and matching?. Latent vs specific heat and how to design for dehumidification? Static pressure and duct design? So many questions. Thanks for sharing
@WreckingCr3W2
@WreckingCr3W2 4 жыл бұрын
I didn't catch the formula you used to determine target superheat bases on indoor wetbulb and outdoor drybulb.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
You can use a target superheat chart or a formula such as ((3xwb)-80-db)/2. I have all of this laid out in the book along with what to do when the target lands on the x instead of a number in a dry climate scenario, thanks!
@UltraHydrophobiccoat
@UltraHydrophobiccoat 4 жыл бұрын
I have a system which has TXV on it. The sub cooling is 13 and the superheat is 32. When the system reaches the set temperature and the system is off, I can hear hissing sound from inside of evaporator for a couple of seconds, then I can hear another different sound like water flowing away from evaporator to outside condenser unit along the lines (not sure suction line or liquid line). The hissing sound last around 4 seconds and the water flowing sound last around 2 seconds. Should I replace the TXV? Thank you so much
@misterlignjoslav6334
@misterlignjoslav6334 4 жыл бұрын
Superheat is high, possible restriction on liquid line, low airflow or low on charge. Not enough refrigerant in liquid line near txv making gurgling sound look like water flowing. Probably that sound is here all the time when system running but maybe you not hear bcz of blower motor noise. What is pressures on low and high?
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Superhydrophobic, That is the system pressures equalizing while the system is off. That is normal depending on the type of txv. There is no problem with that. The superheat does sound a little high though. Make sure to recheck that again and also check the delta T. If the superheat is high and your delta T is low then that could be a partial liquid line restriction. That was why Mister was asking what your low and high side pressures were, thanks
@erwinelarcosa8917
@erwinelarcosa8917 2 жыл бұрын
Sir how can I get the exact superheat of LBP ?
@DWAYNE2ism
@DWAYNE2ism 4 жыл бұрын
How you measure if it's a mini split where it doesn't have a high side port?
@samuelvalenzuela4541
@samuelvalenzuela4541 3 жыл бұрын
And for what reason do you need the high side port on a minisplit?
@mehboz
@mehboz 4 жыл бұрын
Dear Craig, You're doing a great job not also for professionals but also for amateurs. I have a few quick questions for you. if you answer them I would be very grateful. what is the main reason that we should not use the subcooling method fixed orifice systems? Since my condenser unit has a subcooling chart what I should do? Honestly I would like to use subcooling method for piston metering device. Thanks...
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
A fixed orifice will allow superheat to change based on operating conditions so we need to check with superheat. Subcooling is only checked when the TXV metering device controls the superheat and keeps it steady. You could damage your compressor by using subcooling to try to check the charge because superheat is not being monitored. Definitely would not be able to check the charge properly with subcooling for a system with a fixed orifice, thanks!
@benhall6414
@benhall6414 4 жыл бұрын
is that a simulator? what is it called and where can i get it?
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Ben these are the images we used in our book at www.acservicetech.com/ac-book and I would like to build an online course eventually too but presently we have the paperback, ebook, and quick reference cards, thanks!
@jasintodorado8145
@jasintodorado8145 3 жыл бұрын
Hi ,is this book available in Español.
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Yes the spanish paperback and spanish ebook version are both available at www.acservicetech.com/store and the paperback is also available on amazon and the ebook is also available on google play, thanks!
@jasintodorado8145
@jasintodorado8145 3 жыл бұрын
@@acservicetechchannel thanks.
@joshstuckey9977
@joshstuckey9977 Ай бұрын
How do you figure target superheat
@smokex2d309
@smokex2d309 5 ай бұрын
hello do you have your book in spanish?
@acservicetechchannel
@acservicetechchannel 5 ай бұрын
Yes absolutely! check out our spanish book at acservicetech.com/ac-book
@Craig1967
@Craig1967 4 жыл бұрын
Question: What do you do when the WB temperature is 60F and the outdoor DB is 100F? I live in South Florida, and those conditions are pretty typical in the summer. According to the chart, that lands on a blue X. I just went and checked the measurements of my own A/C. R22 WB=69.1F, DB(ouside)=82.2F, Low Side Pressure = 70.0 PSIG. Suction line temp= 64.0 Calculated SH = 22.4, Target should be aprox 21F. Close enough for me, but in the middle of the afternoon when the outdoor temperature goes up to 95 degrees or higher, and indoor WB is around 60F, that lines up with an X. My A/C has a fixed orifice, not a TXV. Usually around the point in the late afternoon when the "X" condition is met, I can clearly hear flashing at the piston. What prevents liquid from coming back to the compressor at those conditions? The evaporator coil has a raised manifold or "header" higher than the coil itself where the suction line is connected. My theory is that my particular evaporator coil also acts as an accumulator. Any help will be appreciated. I recently passed my EPA608, but that definitely does not make me a "know it all."
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
You are on the right track. That is exactly the problem with installing a system with a fixed orifice in a location that can be dry and hot. Arizona is a good example. In those scenarios, a txv should be installed to maintain superheat let alone for efficiency. An accumulator can also be used. It won't act quite like an accumulator but that design may help a little. You may be on the verge of having sat temp in the compressor. Everything you are saying, and how you are saying it is all right on. I am impressed for you just getting the EPA 608. I just got done answering about 70 comments and this one sticks out for some good knowledge for a newer tech, thanks!
@Craig1967
@Craig1967 4 жыл бұрын
@@acservicetechchannel Thanks for the answer. I am not working in the HVAC trade right now, but I have always wanted to. I have always been fascinated by it all. Currently I am in IT, and manage the chiller plant and thermal storage system at my day job.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
@@Craig1967 got ya well that explains it probably processing the thoughts of how the systems all work, anyway great thoughts!
@Craig1967
@Craig1967 4 жыл бұрын
@@acservicetechchannelIt's awesome what you are doing. I bought a whole bunch of equipment, including 5 recovery tanks, recovery machine, gauges, hoses, vacuum pump, spare parts, etc. I figure that if want to get into commercial HVAC as a tech, I have a bunch of stuff to get started. However here in Florida, starting pay for that type of work would not cover my bills. I am really good with computer programming, microcontrollers, and electronics in general. One day an opportunity may present itself. I am somewhat familiar with JCI Metasys. Again thanks for all the education!
@stevee7774
@stevee7774 4 жыл бұрын
Craig Sherman - Man, keep your job working IN the air conditioning not ON it! Just kidding of course, this is coming from a guy that works in a 90+ degree shop every summer.
@eclipse369.
@eclipse369. 4 жыл бұрын
A way to stop losing charge when checking a system every year I think it's best to preload liquid/service(yellow) hose with the correct refrigerant. With normal size hoses that should hold roughly 1.5 oz.. Should be enough to offset any loss. Hopefully ppl are bleeding liquid line back in after disconnecting.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Yes hopefully techs are doing the proper disconnect procedure to move the liquid refrigerant back into the vapor line. If they are then they wouldn't be loosing but a little vapor so that would be much less than 1.5oz and they could also use test probes or test gauges without hoses which will loose less but I am with ya, at some point you need to add some back in, thanks!
@deanbosworth1665
@deanbosworth1665 2 жыл бұрын
I want a book
@acservicetechchannel
@acservicetechchannel 2 жыл бұрын
Good Morning, Thank you for your interest! To purchase a book, you can go right to our website www.acservicetech.com
@kingsleygooden8886
@kingsleygooden8886 3 жыл бұрын
How do u charge a orifice system
@MarioPerez-df9gx
@MarioPerez-df9gx 10 ай бұрын
Excellent explanation, I would like to know what is the average value for the superheat that indicates a refrigerant charge correctly
@juanacosta2788
@juanacosta2788 4 жыл бұрын
Great video
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Glad to help!
Mastering Superheat: The Trick to Charging an HVAC Unit
15:33
Mechanical Pros
Рет қаралды 21 М.
Super gymnastics 😍🫣
00:15
Lexa_Merin
Рет қаралды 98 МЛН
Купили айфон для собачки #shorts #iribaby
00:31
40 VACUUM PROCEDURE TIPS for HVAC Techs! Avoid Frustration and Save Time!
27:12
How To Check Superheat & Subcooling On An HVAC System
16:03
The DIY HVAC Guy
Рет қаралды 86 М.
Finding Target Superheat
15:58
HVAC School
Рет қаралды 18 М.
Scroll Compressor Exposed: Understanding Its Mechanical Magic
14:39
The Engineering Mindset
Рет қаралды 234 М.
Are more STAGES on an air conditioner worth it??
10:28
Atlas AC
Рет қаралды 304 М.
How to Read SUPERHEAT and SUBCOOLING
11:43
Word of Advice TV
Рет қаралды 561 М.
Super gymnastics 😍🫣
00:15
Lexa_Merin
Рет қаралды 98 МЛН