Mechanical ventilation with VENTIFLEX® PLUS system and Ground-Air Heat Exchanger

  Рет қаралды 1,603,492

Ground-Therm Sp. z o.o.

Ground-Therm Sp. z o.o.

7 жыл бұрын

The video shows the VENTIFLEX® PLUS mechanical ventilation with heat recovery co-operating with Ground-Therm's ground-based heat exchanger in an energy-efficient building. For more info visit our web side: www.ground-therm.com

Пікірлер: 320
@stebarg
@stebarg 5 жыл бұрын
It's a good system. We engineered, designed and installed it more than 25 years ago.
@leklaileklai4052
@leklaileklai4052 5 жыл бұрын
Have idea . Can you free energy battery cell heat and cold
@mohammedibrahimali7798
@mohammedibrahimali7798 5 жыл бұрын
Hello Stefan, could you share with me then I can earn money. Safety.mohammed.ibrahim@gmail.com, please mail me
@hafeexius
@hafeexius 4 жыл бұрын
@@mohammedibrahimali7798 what does that even mean? Is it code for 'send bobs and vagene '?
@steelmetal21
@steelmetal21 5 жыл бұрын
This will be ideally suited if this system is installed just next to the u/g water reservoir which can store water from an outside supply or can store water from a system of rain water harvesting. The temperature of the environment beside the water reservoir can be used to have a better ventilation system.
@deepakmanodi6959
@deepakmanodi6959 5 жыл бұрын
Nice idea
@jackriley5974
@jackriley5974 5 жыл бұрын
Nothing is free!! Forty years ago I helped build something similar. The air was moved by two 3/4 HP fans that ran 24/7 . Considering the cost of the structure and the cost of electricity the owner will never break even.
@clintonbarbee5093
@clintonbarbee5093 5 жыл бұрын
I would agree with you except still air excerts more pressure with the right set up an a slight breeze you can create massive air flow. Free.
@MsilikaleMsilanga
@MsilikaleMsilanga 5 жыл бұрын
Clinton Barbee how would i go about. I have no idea how to do it but it seems to be a good idear to implement in my future house.
@jackriley5974
@jackriley5974 5 жыл бұрын
@@clintonbarbee5093 Not arguing science, simply stating a circumstance
@astranger448
@astranger448 3 жыл бұрын
I built one 15 years ago, two variable speed fans averaging 50 watts each (they peak at 150). With a heavily insulated house (one time investment) you will get rid of both a heating system and the power part of the A/C system (you need the ductwork) and their associated energy costs. Average yearly energy cost for a family here is 2000$, I get by with 700. All because of neither heating nor AC.
@neeljain9619
@neeljain9619 3 жыл бұрын
@@astranger448 Hi, if you have installed This system please share the area, location, cost, experience allot the system, since how long you were using this system and in winter what is the temp out and in and same in summer?
@hidayatvijaya8907
@hidayatvijaya8907 5 жыл бұрын
this is interesting...mimicking the nature of a termite mound
@bobelaviador
@bobelaviador 3 жыл бұрын
nature is wise
@facundobellogutierrez5651
@facundobellogutierrez5651 3 жыл бұрын
Great animation!
@TheWinterShade
@TheWinterShade 5 жыл бұрын
This is a basic animation made for those without an understanding of mechanical systems to understand better, not a technical tutorial for engineers, suitable 3D modeling. I'd suggest buying books or find a more detailed and technical tutorial, or discuss with an expert.
@Arthur-Silva
@Arthur-Silva 5 жыл бұрын
I love how the air moves diagonally from one pipe to another 🤣 smart air.
@kml9434
@kml9434 4 жыл бұрын
Lol
@pandass3798
@pandass3798 5 жыл бұрын
Instead of just 3d computer design...Should have shown actual Installation working at a model house.
@bob15479
@bob15479 4 жыл бұрын
that would be a big expense for a startup that already has cad models of all their parts. this video probably cost only $1k.
@michaelgeddes1330
@michaelgeddes1330 4 жыл бұрын
If you look here you will see how fresh the air is 😂😂👍
@ksasiksanthreddy6073
@ksasiksanthreddy6073 4 жыл бұрын
This is my engineering college time project idea in 2013-2015 but college didn't encouraged to make bcos they wont receive commission if I make it on my own, but done lot of paper work on different parameters
@ram2ravanan987
@ram2ravanan987 3 жыл бұрын
Excellent ,why don't you make video like this
@star666lane3
@star666lane3 3 жыл бұрын
@@ram2ravanan987 he died
@mrs.potato586
@mrs.potato586 3 ай бұрын
@@star666lane3lol
@johnboscor.582
@johnboscor.582 Жыл бұрын
Very nice elaboration
@ibadullah8472
@ibadullah8472 9 ай бұрын
MY RESPECTED AND VALUED BROTHER, BE EVER BRIGHT AND KNIGHT. THE REAL HELPERS OF THE HUMANITY.
@Hfsdhjf
@Hfsdhjf 2 жыл бұрын
what is stopping mold and condensation forming inside the pass as hot air enters cool pipes?
@danielmcneely1579
@danielmcneely1579 Жыл бұрын
Just lay the pipe with a slight slope toward the inlet. You’ll also have to incorporate some sort of drain
@aceaj2620
@aceaj2620 4 ай бұрын
I hear they put it at a 3% slope
@Avtowasya
@Avtowasya 3 жыл бұрын
in such a ventilation system, a huge amount of condensation and bacteria is formed!
@zenonkoszorz9606
@zenonkoszorz9606 3 жыл бұрын
Inner layer of pips are covered with antibacterial agent (silver based). Condensation is collected and pumped out from condensation shaft.
@samuelboucher1454
@samuelboucher1454 3 жыл бұрын
Could you not attach air filters on the registers to solve this?
@hphinn
@hphinn 11 ай бұрын
The air should be looped back from the house since the house is at chilled condition. Constantly pulling air from outside will result in a higher temperature difference across the ground heat exchanger.
@ismaeldoprado1794
@ismaeldoprado1794 5 жыл бұрын
show... obrigado
@dontalley2182
@dontalley2182 Жыл бұрын
Great idea! I wish you were in British Columbia Canada. Cheers.
@ursopolar6535
@ursopolar6535 Жыл бұрын
Fantastic
@cedvon4831
@cedvon4831 5 жыл бұрын
Brilliant
@3dakademikadircay563
@3dakademikadircay563 5 жыл бұрын
Beatifuul
@AbdulBasit-di6jk
@AbdulBasit-di6jk 4 жыл бұрын
I am much interested in that kind of setup but the thing is calculations about everything and that can be done with ultimate solutions like uv light cleaner or any other simple n efficient solution. what I am scared off is the temprature as the ground water temperature is not too above the normal temperature I am in Pakistan..
@gowrishankar7338
@gowrishankar7338 5 жыл бұрын
It could better explanation in video because we aren't understanding how ventilation systems work inside house. How air flow transferring outside inlet to inside house.
@ahsankhurshid4939
@ahsankhurshid4939 5 жыл бұрын
This is cool and all but why is this in my recommendations
@ankit.chouksey
@ankit.chouksey 5 жыл бұрын
Paid promotion.
@pandass3798
@pandass3798 5 жыл бұрын
Because youtube algorithms detect locations with hot weather and promotes this.
@karlkarl7282
@karlkarl7282 5 жыл бұрын
Because you touch yourself at night.
@basedbear1605
@basedbear1605 4 жыл бұрын
How can anyone possibly know what is in your play list? It is likely because you've watched a video in the past about geothermal heating or heating systems.
@GoTrack
@GoTrack 5 жыл бұрын
Veeru nice
@christopherclarke2083
@christopherclarke2083 6 жыл бұрын
Looks fantastic, but I wonder how effective it is at cooling compared to a standard AC system.
@Ground-Therm
@Ground-Therm 6 жыл бұрын
It is able to be very effective in case of appropriate design. Many times not proper design kills the effect and the user is not satisfied.
@stebarg
@stebarg 5 жыл бұрын
Christopher Clarke the wondering has come to an end now. 😃 You get ”free” additional energy from the ground. That's the point. The rest is the same. You can add an AC system or not. For most cases, I’d recommend an additional AC system. Not really sure what you mean by effective by the way. 😁 I guess you think in terms of money if you’re talking about effectiveness right? If so, you should consider such a system.
@robvoyles
@robvoyles 3 жыл бұрын
what will be pulling the moisture out of the air? if you don't mold will be an issue.
@DonClark
@DonClark 3 жыл бұрын
What is the average cost? How much can that vary? How much can that cost vary when installing to an older home? Where can I see the data on cost savings over time? What are the risks?
@javimildre9504
@javimildre9504 4 ай бұрын
¿La entrada de aire se puede poner a una altura de 8 metros o no es recomendable?
@amansiddiqi1
@amansiddiqi1 4 жыл бұрын
What are the pros and cons compared to geothermal, which uses a liquid closed loop? That is more common than heating/cooling incoming air.
@robvoyles
@robvoyles 3 жыл бұрын
heating in the winter will need supplemental help heating, this won't be near enough in a typical cold winter.
@mendaanilkumar6028
@mendaanilkumar6028 5 жыл бұрын
I think this not a successful idea because hot air has light weight and always goes up so just make the system opposite direction. I mean Cool air release pipe at floor and the hot air receiving pipe at top. Also add a converting module for winter.
@verohandymike
@verohandymike 5 жыл бұрын
It is fan driven, so the air is forced to go where you want it to. But I still agree that convection should play a part. They should be pulling hot air from the tops of rooms which is where hot air is going to be.
@sajadalbaaj8737
@sajadalbaaj8737 7 жыл бұрын
Nice...please can l get another video about this but without heat exchanger
@Ground-Therm
@Ground-Therm 6 жыл бұрын
Do you want part of this animation? We don't have another amination, just only about ventilation.
@anantheswarreddy1137
@anantheswarreddy1137 4 жыл бұрын
This technology is very good ,is this available in India...
@Good-Feelings-
@Good-Feelings- 5 жыл бұрын
explain please what instrument you are using for pumping hot and cool air in the building...
@VisnitchiRaul
@VisnitchiRaul 5 жыл бұрын
An ventilator.
@ksasiksanthreddy6073
@ksasiksanthreddy6073 4 жыл бұрын
Just an impeller provided fan in outside pipe
@wolverineneo101
@wolverineneo101 5 жыл бұрын
Could it be better if air intake is kept at roof level?
@marcelbregman4454
@marcelbregman4454 4 жыл бұрын
Take in at the shadow site of the building would improve a stable intake temperature without adjusting continuously with every cloud or taking in air from an extreme heated sun spot . But ofcourse you could place the intake higher up when you take notice of these basics. Be aware also of condense or other ways that water can collect in the ground tubes. Let them colect the water in a place where you could easily place a level pomp for removal Of excessive water in the ground system. If possible you can place a small diameter pipewith a sifon to get rid of the water in a well Or open sewer chanel down hill (example)
@GardenOrchid
@GardenOrchid 5 жыл бұрын
Great
@Y34HN0
@Y34HN0 5 жыл бұрын
I'm just asking out of curiosity: Does anyone know if these systems can vary/regulate things like the air humidity of the pumped-in air? Or if they can vary the air-flow to different rooms? Or if these can work with room sensors which measure air quality and vary flow accordingly? This system seems pretty simple. I could be wrong, but I get the impression this would be more expensive to install than standard air conditioning, yet not as flexible.
@acoustic4037
@acoustic4037 5 жыл бұрын
You could, with zone controls etc but this is crap. The HRV has been long in use, and they add a water collecting ground loop and think its new and exciting. There are reasons why its not code to do it this way
@jerryrodriguez9352
@jerryrodriguez9352 5 жыл бұрын
What’s the cost of this on a new construction home in Florida that’s 1500sq
@mohdanfal5061
@mohdanfal5061 5 жыл бұрын
if i wanna install in my house what should I do
@kozakkostya946
@kozakkostya946 5 жыл бұрын
What about condensation in the underground heatexchanger?
@Ariccio123
@Ariccio123 5 жыл бұрын
That's my instant concern here. Joe Lstiburek made this mistake years ago, and talks about it in the context of psychrometric charts.
@bazoozoo1186
@bazoozoo1186 4 жыл бұрын
1) uv light could be used to fight with mold, 2) air from those pipes may not necessarily enter the interior, instead it may swap the temperature via heat exchanger box and get excreted outside. in other words, ideally you would need 2 heat exchange boxes for two stage process: at first you take air from outside the wall and exchange thermal energy with the air from underground, then underground air is dumped outside while the fresh air goes to the second box where it exchanges heat with interior air going into exhaust.
@basedbear1605
@basedbear1605 4 жыл бұрын
@LagiNaLangAko23 Another moron who didn't listen to the presentation.
@basedbear1605
@basedbear1605 4 жыл бұрын
Why don't you watch it again and actually listen this time. It was clearly stated.
@basedbear1605
@basedbear1605 4 жыл бұрын
@@NickMWise 1:32 they talk about their filter system, if you want more details, you are free to click on their link. And later on they talk about mold elimination. Again, you simply didn't listen.
@koveebryant1526
@koveebryant1526 5 жыл бұрын
What about mold inside the underground tubes Love the idea Hrv unit more practical imo
@Rohit90901
@Rohit90901 5 жыл бұрын
M Kovacevic 4:04
@basedbear1605
@basedbear1605 4 жыл бұрын
@@Rohit90901 Amazing how few people actually listened to the presentation, then immediately come here and ask obvious questions that were already answered.
@khanelias7292
@khanelias7292 5 жыл бұрын
How much it will cost and can it be installed in already constructed house .....
@naresh274
@naresh274 4 жыл бұрын
What is the max temperature in which this system is effective? I live in New Delhi, india and we have temperatures 42-47 degree Celsius, would you recommend the system?
@ksasiksanthreddy6073
@ksasiksanthreddy6073 4 жыл бұрын
It is high cost investment at initial but temperature maintains at every time equal throughout the year in 24-26c
@neeljain9619
@neeljain9619 3 жыл бұрын
@@ksasiksanthreddy6073 can you please define how costly initially it will be and who is best co. In india To approach for the same ?
@saqlainmohiddin1280
@saqlainmohiddin1280 4 жыл бұрын
I need mathamatical calculations like how long the pipes are used, how much energy is provided in one hour, how much time is required to heat or cool a room of 10*10 feet etc plz help
@rajenderbattula9970
@rajenderbattula9970 5 жыл бұрын
Great idea Please sir send me the system full details
@rizkiferdian2402
@rizkiferdian2402 4 жыл бұрын
Obviously the same system of air ventilation in a bunker, underground space, panic room, etc. While I am here in a jungle having semi open spaces.
@mahekfaldu
@mahekfaldu 5 жыл бұрын
*Are you sure you call 30°c to hot ? We have 45 °c now*
@wolverineneo101
@wolverineneo101 5 жыл бұрын
30 deg in room is hot
@adarshkumarpatel5030
@adarshkumarpatel5030 Жыл бұрын
😂
@-7-man
@-7-man 5 жыл бұрын
Does the ground continously take away that much heat? Won't there be a decrease in the rate at which heat is extracted after system is operational for a few hours owing to the reduced temperature gradient and slow conduction. Edit: Why not insert the heat exchange pipes in a well for cooling purposes.?
@Ground-Therm
@Ground-Therm 5 жыл бұрын
We count heating and cooling efficiency after system reach (almost) steady conditions - it means after several hours of work, the temperature gradient is constant. Almost, because in real it never happens. Anyway the error is negligible.
@robvoyles
@robvoyles 3 жыл бұрын
Why not insert the heat exchange pipes in a well for cooling purposes?...they do, it's called a cooling tower.
@travnat1
@travnat1 5 жыл бұрын
how do you get rid of the condensation and subsequent mold from the ground heat exchanger?
@basedbear1605
@basedbear1605 4 жыл бұрын
You didn't listen. They clearly said it is lined with a silver composite to prevent mold.
@dallasgombash5381
@dallasgombash5381 4 жыл бұрын
@@basedbear1605 What about the condensation and/or bulk water that ends up down there?
@basedbear1605
@basedbear1605 4 жыл бұрын
@@dallasgombash5381 You didnt watch the video or listen it appears.
@michaelburke7742
@michaelburke7742 4 жыл бұрын
Take it easy smarty pants.
@basedbear1605
@basedbear1605 4 жыл бұрын
@@michaelburke7742 Ok, dummy.
@ratansarkar3674
@ratansarkar3674 4 жыл бұрын
I m from India, i wanna know how much it will cost for 3bh house..plz tell Whom shall I contact for installation, plz let me know..
@Wok_Agenda
@Wok_Agenda 5 жыл бұрын
Very nice system but I have one question , how do you clean the ground installed pipes?
@hemant3640
@hemant3640 5 жыл бұрын
शायद इसमें वैक्यूम cleaner जैसे किसी मशीन का सहारा लेना पड़ सकता है
@raveeranjankuma
@raveeranjankuma 5 жыл бұрын
Good job hemant sharma.. Keep it up.. Hehehe
@Ground-Therm
@Ground-Therm 5 жыл бұрын
Once per 5 years it's good to rinse with a strong stream of water. You have to get (leave) acces to the pipe incoming into house.
@Wok_Agenda
@Wok_Agenda 5 жыл бұрын
@@Ground-Therm Thank you
@stebarg
@stebarg 5 жыл бұрын
Dimitris Andreou our system runs without maintenance for about 25 years now. We haven't thought about cleaning the earth pipes yet.
@adiliraliyev5882
@adiliraliyev5882 2 ай бұрын
...thinking...hot air moves up due to buoyancy...how much time does it take for air to exchange heat with an environment...?
@ananddixit9576
@ananddixit9576 4 жыл бұрын
Please use live model to know whether it's feasible
@designerlp
@designerlp 3 жыл бұрын
Good Morning! Can I use excerpts from your video to put on an architect's reels talking about a Canadian well?
@Ground-Therm
@Ground-Therm 2 жыл бұрын
Yes, you can.
@mohitladdha8550
@mohitladdha8550 5 жыл бұрын
Is any presence in India ?
@michaeld954
@michaeld954 5 жыл бұрын
Will this work with shipping container homes
@ksasiksanthreddy6073
@ksasiksanthreddy6073 4 жыл бұрын
Yes
@imtiazhussain1524
@imtiazhussain1524 Жыл бұрын
what is the pipe matreal is plastic pvc? or metal like cuppar ?if the is pvc which is non conducter matrial so how it the reduce the temparature being non con conducter materil
@justinroca932
@justinroca932 2 жыл бұрын
I just don't understand how the air circulates. Is there a fan?
@alifalawi
@alifalawi 5 жыл бұрын
Penerapan nyatanya di rumah2 indonesia sudah ada ga? Referensi dan laporannya ada yg tahu?
@pedzis
@pedzis 5 жыл бұрын
Good
@jaymig4701
@jaymig4701 2 жыл бұрын
I am in Jordan and I am interesting in this system how I can get it
@InfotainmentVidyarthi
@InfotainmentVidyarthi 4 жыл бұрын
Wouldn't air coming from inside the house and from outside of house while interacting in the exchanger, pollute the fresh outside air ?
@Zshazz
@Zshazz 3 жыл бұрын
What they're probably describing is a Heat Recovery Ventilator (HRV). In summary, no it does not because the air actually doesn't mix together in the box, it's just a convenient model they used here. The box itself is a heat exchanger of some type, e.g. using heat pipes or thin metal plates, and the air is actually going through completely separate channels through those heat exchangers, so the fresh air stays fresh but the heat between the incoming air is brought closer to temperature to the outgoing air. Such devices can often exceed 70% efficiency in matching the incoming air with the outgoing air, so despite how simple the idea is for this device, it's an exceptionally effective way for you to prevent heat/cooling loss with the fresh air coming in. They also have Enthalpy Recovery Ventilators (ERVs, sometimes misnamed "Energy" Recovery Ventilators) which have a semi-permeable membrane which allows humidity to be exchanged as well (again, without actually mixing the air itself), which is super important in high-humidity environments (e.g. southern US states) because you will "get more" out of cooling your house if you can reduce the humidity (using a dehumidifier, for instance), and retaining that reduction in humidity means huge energy savings without a cost to comfort.
@johncommon4294
@johncommon4294 4 жыл бұрын
How deep you have to dig the pipes, and how much energy the system consumes? Now much is not good enough. How many wats it takes? How much it cost to purchase or you sell it with installation costs? Do you supply to places in Lubuskie?
@basedbear1605
@basedbear1605 4 жыл бұрын
1) below the frost line. Usually 5-8 feet down. 2)The energy would depend on the size of the system. 3)The energy would depend on the size of the system. 4&5)I would suggest contacting the company directly.
@astranger448
@astranger448 3 жыл бұрын
For my compact and well insulated house I DIY'd one, has been working for 15yrs now. Pipe 15cm/6", 50m/yrd long as 2 parallel line, slope 2cm 3/4" per m/yrd at a dept +/- 3m/yrd. Energy use is one 50/100ish watt fan, it pays to oversize a variable speed type. There is a lot of flexibility size-wise there but a lot depends on the dig. There must be a slope for condensate to drain to a lowest point, with a few slits over a gravel drain. Because of this drain you must stay above ground water. The inhouse system as shown in the video is a whole other kettle of fish. It's ok in a new house but rather tough as a refit. Power consumption there doubles as there are two fans needed now.
@AllVie
@AllVie 5 жыл бұрын
Wow
@patrickyounes8891
@patrickyounes8891 Жыл бұрын
Why do we not use this in Australia?
@user-di1kw8en6o
@user-di1kw8en6o 4 жыл бұрын
Куда и каким образом девать конденсат ?
@mirzamomtajuddinbaidya4654
@mirzamomtajuddinbaidya4654 5 жыл бұрын
Which software you used for these animation? Please help
@jakeblaze7663
@jakeblaze7663 3 жыл бұрын
Underware
@amanwithhiscigaretteandcof3474
@amanwithhiscigaretteandcof3474 5 жыл бұрын
..good idea. but not friendlymoneyuser.
@billnipp2309
@billnipp2309 5 жыл бұрын
so any outdoor orders will be sucked into your house. and the house would be very positive to the outside, which isnt such a bad thing.
@acoustic4037
@acoustic4037 5 жыл бұрын
The HRV would keep pressures equal. Same in as out. Its still crap, the ground loop will fill up with condensate
@plumsmuglers
@plumsmuglers 5 жыл бұрын
acoustic4037 atmospheric water harvesting 🐸
@forcedair92gt94
@forcedair92gt94 5 жыл бұрын
@ 1:35 filters are mentioned.
@emulatorretro
@emulatorretro 5 жыл бұрын
this is called a Baghdad air conditioner.
@jeuneyvesaguilarbaldove7089
@jeuneyvesaguilarbaldove7089 Жыл бұрын
how was this animated... which software?
@harshpatel89
@harshpatel89 6 жыл бұрын
i want to install in my new bulid home give me proper idea .
@Ground-Therm
@Ground-Therm 5 жыл бұрын
Just send us (projekty@ground-therm.com) your demand for air volume or architectural design and land development plan. Then we can advice proper solution.
@harshpatel89
@harshpatel89 5 жыл бұрын
@@Ground-Therm sure i will sand is to you .
@adityapanwar4840
@adityapanwar4840 5 жыл бұрын
Pipes used are of what material
@tombouie
@tombouie 5 жыл бұрын
Hmmmmmmmm humidity will probably condensate against the cool inner pipe metal. Condensation within the pipes might cause microbe growth. UV lights might hinder microbe growth though.
@Ground-Therm
@Ground-Therm 5 жыл бұрын
No chance for microbs - all internal layer of tubes are protected with silver agent - anti-bacterial and anti-fungi.
@tombouie
@tombouie 5 жыл бұрын
Hmmmm, this is an very ancient technology & numerous countries have looked at it in modern times. For example: Earth tubes as heat exchanger for geothermal ventilation / AC / cooling and heating passive house kzbin.info/www/bejne/omXRfqZ-pqiHm6s Microbes are absolutely everywhere & at best their growth might be retarded but never eliminated. Really, I can only assume the only practical reason why this technology is not used universally is the potential for microbe contamination. So I plan to use a flexible corrugated ducting (with anti-microbe coating, LED UV lights, etc) and simply make it removable/clean-able/replaceable/inspect-able/etc. Pls consider making your design open source (note there are many types of open source licenses; fossbytes.com/open-sources-license-type/). This allows folks living on a budget to potential use your system. Worry not, since rich folks are too busy/lazy to make your system for themselves, you'll still get tons of business especially in the US. If you manage your company well, cheap knock-offs won’t really hurt you much. Also being open source, you just might unite all the good work all over the globe in this area. There have been a lot of work. Here's open source in a nutshell: What is Open Source explained in LEGO kzbin.info/www/bejne/l2nJeZqubtJ4a7c
@mlionea
@mlionea Жыл бұрын
which company can offer this technology to an airport in UAE?
@MMaheshThakur
@MMaheshThakur 5 жыл бұрын
This is very old technic I have seen it in one india palace. How to install it in our homes.how mux cose it will take
@georgekurian8335
@georgekurian8335 5 жыл бұрын
Which palace in India
@JaspalSingh-rs7pz
@JaspalSingh-rs7pz 5 жыл бұрын
Please reply
@MMaheshThakur
@MMaheshThakur 5 жыл бұрын
@@JaspalSingh-rs7pz what reply sir. there is nothing special in this.
@Cybernetic1
@Cybernetic1 5 жыл бұрын
@@MMaheshThakur which place?
@basedbear1605
@basedbear1605 4 жыл бұрын
@@MMaheshThakur You were asked 3x. which palace did you see it in?
@anticeon
@anticeon 5 жыл бұрын
I live in tropical place
@sholykhan5613
@sholykhan5613 5 жыл бұрын
how much cost
@jawa5669
@jawa5669 4 жыл бұрын
What about the in ground preheater and getting mold in the actual pipe under the ground guess this system has no longevity
@astranger448
@astranger448 3 жыл бұрын
I built my own 15 years ago. Don't stop the airflow and slope the pipe to a lowest point, cut some slits there over a gravel drain. Also stay above groundwater level.
@VacationFor
@VacationFor 5 жыл бұрын
what is someone put toxic gas inside the pipe ???
@yahtadi5152
@yahtadi5152 5 жыл бұрын
Great way to rampage
@koveebryant1526
@koveebryant1526 5 жыл бұрын
Lol Valid point
@ltsallwood
@ltsallwood 5 жыл бұрын
What if someone dipped a baby in a tank of acid???
@nurramlak1175
@nurramlak1175 4 жыл бұрын
can you give subtitle indonesian...?
@patmaker007
@patmaker007 10 ай бұрын
Intellegent of ground HE. But it has very high of investment and maintenance cost.
@thecriminallawyer2503
@thecriminallawyer2503 5 жыл бұрын
In rajasthan (india) outside temprature 45 and inside building 30
@thecriminallawyer2503
@thecriminallawyer2503 5 жыл бұрын
@A K its call aastha,,, and we have good manners ok ..lol
@pavelbaidurov228
@pavelbaidurov228 5 жыл бұрын
You all should build such systems at homes, it is faar cheaper than air conditioner in the long run
@TANVEER2011ify
@TANVEER2011ify 5 жыл бұрын
I am interested Hw I can install
@flatpancake1162
@flatpancake1162 5 жыл бұрын
Tanveer Sate diy
@kohdefresh
@kohdefresh 4 жыл бұрын
in Canada we have raccoons that like to break into EVERYTHING... so when one gets in and dies.. whose getting that out because of the smell going through the house lol
@astranger448
@astranger448 3 жыл бұрын
Funny thing, this system is known the world round as a 'Puits Canadien/Canadian Well" Probably introduced by French Immigrants who call this a Puits(well) Provençale (which is the south of France). Maybe ask your neighbors how they deal with the occasional moose getting into theirs ;-)
@ExploringGenesis
@ExploringGenesis 4 жыл бұрын
By Which software you make this video?
@markusjordantesoro2992
@markusjordantesoro2992 Ай бұрын
When bad person put a chemical to the intake air ventilation all the people inside the house inhale the chemical I think when you do this kind of ventilation make sure to hide the intake ventilation.
@user-ws5cn8xh9y
@user-ws5cn8xh9y 5 жыл бұрын
и зачем я это смотрю , у меня даже нет дома
@kalamazath9304
@kalamazath9304 5 жыл бұрын
How the underground heat exchanger cools the air in summer and heat the air in winter??
@hemant3640
@hemant3640 5 жыл бұрын
मेरे ज्ञान के अनुसार जमीन से 7-8 फीट के बाद तापमान हमेशा एक ही रहेता हैं। कुएं और बोरिंग में पानी सर्दियों में गर्म और गर्मियों में ठंडा आता हैं।
@kalamazath9304
@kalamazath9304 5 жыл бұрын
@@hemant3640 thanks bro
@Ground-Therm
@Ground-Therm 5 жыл бұрын
Temperature in the ground (1,7 m below the surface) is generally (in Europe) at the level of 4-12 °C
@kalamazath9304
@kalamazath9304 5 жыл бұрын
@@Ground-Therm how it is possible to heat the air in winter?
@saxonsoldier67
@saxonsoldier67 5 жыл бұрын
@@kalamazath9304 All Year, the geothermal unit will maintain near the underground temp. The Earth will moderate the seasonal highs and lows.
@vinerfahrtdinov5048
@vinerfahrtdinov5048 4 жыл бұрын
Непонятно автоматизация смешивания потоков
@felixromano3091
@felixromano3091 3 жыл бұрын
Is this the guy from epic economist ?
@user-nx8fu2jr8p
@user-nx8fu2jr8p 4 жыл бұрын
Возьмите меня к себе на работу
@plumsmuglers
@plumsmuglers 5 жыл бұрын
Where is THE UVC LIGHT to kill mold ?
@brettmoore3194
@brettmoore3194 5 жыл бұрын
They used silver particles,impregnated in the inside of,the,ductwork . silver is,the worlds oldest and,most effective biological,remedy
@plumsmuglers
@plumsmuglers 5 жыл бұрын
Brett Moore well other than Sunlight, preventing mold on the inner surface is a good start.
@brettmoore3194
@brettmoore3194 5 жыл бұрын
@@plumsmuglers not sure of your response but with the silver lining a electrostatic charge could be used,to prevent any dust buildup too
@plumsmuglers
@plumsmuglers 5 жыл бұрын
Brett Moore It would need that, because a coating would be nullified if any significant dust were allowed to build up on it, whereas UV Light is far more forgiving.
@brettmoore3194
@brettmoore3194 5 жыл бұрын
@@plumsmuglers I,don't doubt sum,systems,were designed,to bring sickness. We have technologies that makes,the,jetsons look,like,cavemem
@erdene-ochirmijid4040
@erdene-ochirmijid4040 2 жыл бұрын
How to solve condensation in earth tubes this project?
@Ground-Therm
@Ground-Therm 2 жыл бұрын
Just by pumping it out from collector shaft or connection to draining to the sewage system.
@Harman2701
@Harman2701 Жыл бұрын
I want in india...do u have any dealer in india?
@dwdfusion3138
@dwdfusion3138 5 жыл бұрын
Can this system work in desert countries
@Ground-Therm
@Ground-Therm 5 жыл бұрын
We are just preparing such systems for housing estate for over 1000 homes in Dubai.
@neeljain9619
@neeljain9619 3 жыл бұрын
@@Ground-Therm have you ever installed such system in India or if you have partner or representative in India. Please share some costing and investment figures for broader perspective?
@hunkpandey9283
@hunkpandey9283 Жыл бұрын
​@@Ground-Therm plzz reply
@marcgatto9675
@marcgatto9675 Жыл бұрын
Can this system be integrated with a heat pump?
@thomasschafer7268
@thomasschafer7268 Жыл бұрын
No.this ventilates. No heating. But you can use the energy from the old warm air for making hot water
@imbbasp4047
@imbbasp4047 4 жыл бұрын
Who keeps rodents out of dark environment pipes?
@vladstoica1946
@vladstoica1946 3 жыл бұрын
a series of metal grates or something?
@RadRidesByCru
@RadRidesByCru 5 жыл бұрын
Wait until one of those tube under the house gets a joint crack and the entire system fills with ground water.
@forcedair92gt94
@forcedair92gt94 5 жыл бұрын
There are negatives to all systems. Rodents in your attic eating through your AC tubing is equally as dangerous.
@RadRidesByCru
@RadRidesByCru 5 жыл бұрын
I don't have rodents in my attic, and if I did, I can do something about it. All houses have water under them, nothing you can do about that. Nor can you do anything about the movement of the ground or your house. Nor can you repair this when it fails.
@astranger448
@astranger448 3 жыл бұрын
Build above groundwater. It is a very essential piece of info before you get your shovel out. Slope the tubes, add drain slit at lowest point over gravel bed. This will get rid of the condensate. If groundwater happens (I have it very rarely if a winter is really wet) make sure that your lowest point has easy access, it pumps out in a minute with an ordinary garden pump
@michaeld954
@michaeld954 3 жыл бұрын
How much is this system and can it heat water
@thomasschafer7268
@thomasschafer7268 Жыл бұрын
No. For warming the air
@trtinda11
@trtinda11 4 жыл бұрын
hello mold.....
@genresong952
@genresong952 5 жыл бұрын
Sir we have basement
@benkojr
@benkojr 5 жыл бұрын
All good until the mold spores get sucked in!
@zenonkoszorz9606
@zenonkoszorz9606 5 жыл бұрын
Mold have no chance to grow - internal layer of all pipes are covered by silver agent - anti-bacterial and anti-fungi !
@astranger448
@astranger448 3 жыл бұрын
Mold likes a quit place to grow, keeping the fan going all the time does the trick.
@sumitKumar-zv4vs
@sumitKumar-zv4vs 5 жыл бұрын
इसको बनाने के लिए क्या क्या जरूरत पड़ेगी
How to cool our homes (even without ACs)
13:00
DW Planet A
Рет қаралды 2,7 МЛН
15 ENERGY EFFICIENT INVENTIONS FOR YOUR HOME
15:01
TechZone
Рет қаралды 932 М.
WORLD'S SHORTEST WOMAN
00:58
Stokes Twins
Рет қаралды 114 МЛН
لقد سرقت حلوى القطن بشكل خفي لأصنع مصاصة🤫😎
00:33
Cool Tool SHORTS Arabic
Рет қаралды 22 МЛН
Smart control for effective ventilation (EN)
7:03
Komfovent
Рет қаралды 160 М.
Is Geothermal Heating and Cooling Worth the Cost?  Heat Pumps Explained
12:23
Undecided with Matt Ferrell
Рет қаралды 3,5 МЛН
Earth air tunnels (EAT)
5:59
ArchiMinds
Рет қаралды 21 М.
These 5 Innovations Will Change Everything!
10:44
Leaf of Life
Рет қаралды 47 М.
How this ANCIENT wind catcher make building cool
2:39
HOME TUBE
Рет қаралды 407 М.
Basement Waterproofing - How To Permanently Waterproof A Basement
2:25
BASEco Foundation Systems
Рет қаралды 3,1 МЛН
Вентиляция в частном доме - ТОП 3 варианта - плюсы и минусы
43:01
Вентиляция в квартире и доме Dmitry_HVAC
Рет қаралды 45 М.
КРУТОЙ ТЕЛЕФОН
0:16
KINO KAIF
Рет қаралды 6 МЛН
Xiaomi SU-7 Max 2024 - Самый быстрый мобильник
32:11
Клубный сервис
Рет қаралды 540 М.
Kumanda İle Bilgisayarı Yönetmek #shorts
0:29
Osman Kabadayı
Рет қаралды 2,4 МЛН