Nothing is free!! Forty years ago I helped build something similar. The air was moved by two 3/4 HP fans that ran 24/7 . Considering the cost of the structure and the cost of electricity the owner will never break even.
@clintonbarbee50935 жыл бұрын
I would agree with you except still air excerts more pressure with the right set up an a slight breeze you can create massive air flow. Free.
@MsilikaleMsilanga5 жыл бұрын
Clinton Barbee how would i go about. I have no idea how to do it but it seems to be a good idear to implement in my future house.
@jackriley59745 жыл бұрын
@@clintonbarbee5093 Not arguing science, simply stating a circumstance
@astranger4484 жыл бұрын
I built one 15 years ago, two variable speed fans averaging 50 watts each (they peak at 150). With a heavily insulated house (one time investment) you will get rid of both a heating system and the power part of the A/C system (you need the ductwork) and their associated energy costs. Average yearly energy cost for a family here is 2000$, I get by with 700. All because of neither heating nor AC.
@neeljain96194 жыл бұрын
@@astranger448 Hi, if you have installed This system please share the area, location, cost, experience allot the system, since how long you were using this system and in winter what is the temp out and in and same in summer?
@steelmetal215 жыл бұрын
This will be ideally suited if this system is installed just next to the u/g water reservoir which can store water from an outside supply or can store water from a system of rain water harvesting. The temperature of the environment beside the water reservoir can be used to have a better ventilation system.
@deepakmanodi69595 жыл бұрын
Nice idea
@stebarg5 жыл бұрын
It's a good system. We engineered, designed and installed it more than 25 years ago.
@leklaileklai40525 жыл бұрын
Have idea . Can you free energy battery cell heat and cold
@mohammedibrahimali77985 жыл бұрын
Hello Stefan, could you share with me then I can earn money. Safety.mohammed.ibrahim@gmail.com, please mail me
@hafeexius4 жыл бұрын
@@mohammedibrahimali7798 what does that even mean? Is it code for 'send bobs and vagene '?
@Hfsdhjf2 жыл бұрын
what is stopping mold and condensation forming inside the pass as hot air enters cool pipes?
@danielmcneely1579 Жыл бұрын
Just lay the pipe with a slight slope toward the inlet. You’ll also have to incorporate some sort of drain
@aceaj262010 ай бұрын
I hear they put it at a 3% slope
@kozakkostya9465 жыл бұрын
What about condensation in the underground heatexchanger?
@Ariccio1235 жыл бұрын
That's my instant concern here. Joe Lstiburek made this mistake years ago, and talks about it in the context of psychrometric charts.
@bazoozoo11865 жыл бұрын
1) uv light could be used to fight with mold, 2) air from those pipes may not necessarily enter the interior, instead it may swap the temperature via heat exchanger box and get excreted outside. in other words, ideally you would need 2 heat exchange boxes for two stage process: at first you take air from outside the wall and exchange thermal energy with the air from underground, then underground air is dumped outside while the fresh air goes to the second box where it exchanges heat with interior air going into exhaust.
@basedbear16055 жыл бұрын
@LagiNaLangAko23 Another moron who didn't listen to the presentation.
@basedbear16055 жыл бұрын
Why don't you watch it again and actually listen this time. It was clearly stated.
@basedbear16055 жыл бұрын
@@NickMWise 1:32 they talk about their filter system, if you want more details, you are free to click on their link. And later on they talk about mold elimination. Again, you simply didn't listen.
@ksasiksanthreddy60734 жыл бұрын
This is my engineering college time project idea in 2013-2015 but college didn't encouraged to make bcos they wont receive commission if I make it on my own, but done lot of paper work on different parameters
@ram2ravanan9873 жыл бұрын
Excellent ,why don't you make video like this
@star666lane33 жыл бұрын
@@ram2ravanan987 he died
@mrs.potato5869 ай бұрын
@@star666lane3lol
@Arthur-Silva5 жыл бұрын
I love how the air moves diagonally from one pipe to another 🤣 smart air.
@kml94345 жыл бұрын
Lol
@Wok_Agenda5 жыл бұрын
Very nice system but I have one question , how do you clean the ground installed pipes?
@hemant36405 жыл бұрын
शायद इसमें वैक्यूम cleaner जैसे किसी मशीन का सहारा लेना पड़ सकता है
@raveeranjankuma5 жыл бұрын
Good job hemant sharma.. Keep it up.. Hehehe
@Ground-Therm5 жыл бұрын
Once per 5 years it's good to rinse with a strong stream of water. You have to get (leave) acces to the pipe incoming into house.
@Wok_Agenda5 жыл бұрын
@@Ground-Therm Thank you
@stebarg5 жыл бұрын
Dimitris Andreou our system runs without maintenance for about 25 years now. We haven't thought about cleaning the earth pipes yet.
@TheWinterShade5 жыл бұрын
This is a basic animation made for those without an understanding of mechanical systems to understand better, not a technical tutorial for engineers, suitable 3D modeling. I'd suggest buying books or find a more detailed and technical tutorial, or discuss with an expert.
@the2paths5 жыл бұрын
Could it be better if air intake is kept at roof level?
@marcelbregman44545 жыл бұрын
Take in at the shadow site of the building would improve a stable intake temperature without adjusting continuously with every cloud or taking in air from an extreme heated sun spot . But ofcourse you could place the intake higher up when you take notice of these basics. Be aware also of condense or other ways that water can collect in the ground tubes. Let them colect the water in a place where you could easily place a level pomp for removal Of excessive water in the ground system. If possible you can place a small diameter pipewith a sifon to get rid of the water in a well Or open sewer chanel down hill (example)
@travnat15 жыл бұрын
how do you get rid of the condensation and subsequent mold from the ground heat exchanger?
@basedbear16055 жыл бұрын
You didn't listen. They clearly said it is lined with a silver composite to prevent mold.
@dallasgombash53815 жыл бұрын
@@basedbear1605 What about the condensation and/or bulk water that ends up down there?
@basedbear16055 жыл бұрын
@@dallasgombash5381 You didnt watch the video or listen it appears.
@michaelburke77425 жыл бұрын
Take it easy smarty pants.
@basedbear16055 жыл бұрын
@@michaelburke7742 Ok, dummy.
@hidayatvijaya89075 жыл бұрын
this is interesting...mimicking the nature of a termite mound
@bobelaviador4 жыл бұрын
nature is wise
@christopherclarke20837 жыл бұрын
Looks fantastic, but I wonder how effective it is at cooling compared to a standard AC system.
@Ground-Therm6 жыл бұрын
It is able to be very effective in case of appropriate design. Many times not proper design kills the effect and the user is not satisfied.
@stebarg5 жыл бұрын
Christopher Clarke the wondering has come to an end now. 😃 You get ”free” additional energy from the ground. That's the point. The rest is the same. You can add an AC system or not. For most cases, I’d recommend an additional AC system. Not really sure what you mean by effective by the way. 😁 I guess you think in terms of money if you’re talking about effectiveness right? If so, you should consider such a system.
@pandass37985 жыл бұрын
Instead of just 3d computer design...Should have shown actual Installation working at a model house.
@bob154795 жыл бұрын
that would be a big expense for a startup that already has cad models of all their parts. this video probably cost only $1k.
@michaelgeddes13305 жыл бұрын
If you look here you will see how fresh the air is 😂😂👍
@Good-Feelings-6 жыл бұрын
explain please what instrument you are using for pumping hot and cool air in the building...
@VisnitchiRaul5 жыл бұрын
An ventilator.
@ksasiksanthreddy60734 жыл бұрын
Just an impeller provided fan in outside pipe
@designerlp3 жыл бұрын
Good Morning! Can I use excerpts from your video to put on an architect's reels talking about a Canadian well?
@Ground-Therm3 жыл бұрын
Yes, you can.
@robvoyles4 жыл бұрын
what will be pulling the moisture out of the air? if you don't mold will be an issue.
@hphinn Жыл бұрын
The air should be looped back from the house since the house is at chilled condition. Constantly pulling air from outside will result in a higher temperature difference across the ground heat exchanger.
@AbdulBasit-di6jk5 жыл бұрын
I am much interested in that kind of setup but the thing is calculations about everything and that can be done with ultimate solutions like uv light cleaner or any other simple n efficient solution. what I am scared off is the temprature as the ground water temperature is not too above the normal temperature I am in Pakistan..
@amansiddiqi14 жыл бұрын
What are the pros and cons compared to geothermal, which uses a liquid closed loop? That is more common than heating/cooling incoming air.
@robvoyles4 жыл бұрын
heating in the winter will need supplemental help heating, this won't be near enough in a typical cold winter.
@mahekfaldu5 жыл бұрын
*Are you sure you call 30°c to hot ? We have 45 °c now*
@the2paths5 жыл бұрын
30 deg in room is hot
@adarshkumarpatel5030 Жыл бұрын
😂
@adiliraliyev58828 ай бұрын
...thinking...hot air moves up due to buoyancy...how much time does it take for air to exchange heat with an environment...?
@johncommon42945 жыл бұрын
How deep you have to dig the pipes, and how much energy the system consumes? Now much is not good enough. How many wats it takes? How much it cost to purchase or you sell it with installation costs? Do you supply to places in Lubuskie?
@basedbear16055 жыл бұрын
1) below the frost line. Usually 5-8 feet down. 2)The energy would depend on the size of the system. 3)The energy would depend on the size of the system. 4&5)I would suggest contacting the company directly.
@astranger4484 жыл бұрын
For my compact and well insulated house I DIY'd one, has been working for 15yrs now. Pipe 15cm/6", 50m/yrd long as 2 parallel line, slope 2cm 3/4" per m/yrd at a dept +/- 3m/yrd. Energy use is one 50/100ish watt fan, it pays to oversize a variable speed type. There is a lot of flexibility size-wise there but a lot depends on the dig. There must be a slope for condensate to drain to a lowest point, with a few slits over a gravel drain. Because of this drain you must stay above ground water. The inhouse system as shown in the video is a whole other kettle of fish. It's ok in a new house but rather tough as a refit. Power consumption there doubles as there are two fans needed now.
@-7-man5 жыл бұрын
Does the ground continously take away that much heat? Won't there be a decrease in the rate at which heat is extracted after system is operational for a few hours owing to the reduced temperature gradient and slow conduction. Edit: Why not insert the heat exchange pipes in a well for cooling purposes.?
@Ground-Therm5 жыл бұрын
We count heating and cooling efficiency after system reach (almost) steady conditions - it means after several hours of work, the temperature gradient is constant. Almost, because in real it never happens. Anyway the error is negligible.
@robvoyles4 жыл бұрын
Why not insert the heat exchange pipes in a well for cooling purposes?...they do, it's called a cooling tower.
@naresh2744 жыл бұрын
What is the max temperature in which this system is effective? I live in New Delhi, india and we have temperatures 42-47 degree Celsius, would you recommend the system?
@ksasiksanthreddy60734 жыл бұрын
It is high cost investment at initial but temperature maintains at every time equal throughout the year in 24-26c
@neeljain96194 жыл бұрын
@@ksasiksanthreddy6073 can you please define how costly initially it will be and who is best co. In india To approach for the same ?
@anantheswarreddy11374 жыл бұрын
This technology is very good ,is this available in India...
@ibadullah8472 Жыл бұрын
MY RESPECTED AND VALUED BROTHER, BE EVER BRIGHT AND KNIGHT. THE REAL HELPERS OF THE HUMANITY.
@dontalley2182 Жыл бұрын
Great idea! I wish you were in British Columbia Canada. Cheers.
@michaeld9545 жыл бұрын
Will this work with shipping container homes
@ksasiksanthreddy60734 жыл бұрын
Yes
@patrickyounes88912 жыл бұрын
Why do we not use this in Australia?
@justinroca9322 жыл бұрын
I just don't understand how the air circulates. Is there a fan?
@ahsankhurshid49395 жыл бұрын
This is cool and all but why is this in my recommendations
@ankit.chouksey5 жыл бұрын
Paid promotion.
@pandass37985 жыл бұрын
Because youtube algorithms detect locations with hot weather and promotes this.
@karlkarl72825 жыл бұрын
Because you touch yourself at night.
@basedbear16055 жыл бұрын
How can anyone possibly know what is in your play list? It is likely because you've watched a video in the past about geothermal heating or heating systems.
@ratansarkar36744 жыл бұрын
I m from India, i wanna know how much it will cost for 3bh house..plz tell Whom shall I contact for installation, plz let me know..
@javimildre950410 ай бұрын
¿La entrada de aire se puede poner a una altura de 8 metros o no es recomendable?
@jaymig47013 жыл бұрын
I am in Jordan and I am interesting in this system how I can get it
@imtiazhussain1524 Жыл бұрын
what is the pipe matreal is plastic pvc? or metal like cuppar ?if the is pvc which is non conducter matrial so how it the reduce the temparature being non con conducter materil
@DonClark4 жыл бұрын
What is the average cost? How much can that vary? How much can that cost vary when installing to an older home? Where can I see the data on cost savings over time? What are the risks?
@1minCAD4 жыл бұрын
Wouldn't air coming from inside the house and from outside of house while interacting in the exchanger, pollute the fresh outside air ?
@Zshazz3 жыл бұрын
What they're probably describing is a Heat Recovery Ventilator (HRV). In summary, no it does not because the air actually doesn't mix together in the box, it's just a convenient model they used here. The box itself is a heat exchanger of some type, e.g. using heat pipes or thin metal plates, and the air is actually going through completely separate channels through those heat exchangers, so the fresh air stays fresh but the heat between the incoming air is brought closer to temperature to the outgoing air. Such devices can often exceed 70% efficiency in matching the incoming air with the outgoing air, so despite how simple the idea is for this device, it's an exceptionally effective way for you to prevent heat/cooling loss with the fresh air coming in. They also have Enthalpy Recovery Ventilators (ERVs, sometimes misnamed "Energy" Recovery Ventilators) which have a semi-permeable membrane which allows humidity to be exchanged as well (again, without actually mixing the air itself), which is super important in high-humidity environments (e.g. southern US states) because you will "get more" out of cooling your house if you can reduce the humidity (using a dehumidifier, for instance), and retaining that reduction in humidity means huge energy savings without a cost to comfort.
@mendaanilkumar60285 жыл бұрын
I think this not a successful idea because hot air has light weight and always goes up so just make the system opposite direction. I mean Cool air release pipe at floor and the hot air receiving pipe at top. Also add a converting module for winter.
@verohandymike5 жыл бұрын
It is fan driven, so the air is forced to go where you want it to. But I still agree that convection should play a part. They should be pulling hot air from the tops of rooms which is where hot air is going to be.
@Y34HN06 жыл бұрын
I'm just asking out of curiosity: Does anyone know if these systems can vary/regulate things like the air humidity of the pumped-in air? Or if they can vary the air-flow to different rooms? Or if these can work with room sensors which measure air quality and vary flow accordingly? This system seems pretty simple. I could be wrong, but I get the impression this would be more expensive to install than standard air conditioning, yet not as flexible.
@acoustic40375 жыл бұрын
You could, with zone controls etc but this is crap. The HRV has been long in use, and they add a water collecting ground loop and think its new and exciting. There are reasons why its not code to do it this way
@VacationFor5 жыл бұрын
what is someone put toxic gas inside the pipe ???
@yahtadi51525 жыл бұрын
Great way to rampage
@koveebryant15265 жыл бұрын
Lol Valid point
@ltsallwood5 жыл бұрын
What if someone dipped a baby in a tank of acid???
@Duongzpipe2 ай бұрын
What material is the underground pipe?
@learndesignwithdev27 күн бұрын
PEX tubing I think.
@facundobellogutierrez56513 жыл бұрын
Great animation!
@mirzamomtajuddinbaidya46545 жыл бұрын
Which software you used for these animation? Please help
@jakeblaze76633 жыл бұрын
Underware
@johnboscor.582 Жыл бұрын
Very nice elaboration
@jeuneyvesaguilarbaldove7089 Жыл бұрын
how was this animated... which software?
@khanelias72925 жыл бұрын
How much it will cost and can it be installed in already constructed house .....
@sajadalbaaj87377 жыл бұрын
Nice...please can l get another video about this but without heat exchanger
@Ground-Therm7 жыл бұрын
Do you want part of this animation? We don't have another amination, just only about ventilation.
@kalamazath93045 жыл бұрын
How the underground heat exchanger cools the air in summer and heat the air in winter??
@hemant36405 жыл бұрын
मेरे ज्ञान के अनुसार जमीन से 7-8 फीट के बाद तापमान हमेशा एक ही रहेता हैं। कुएं और बोरिंग में पानी सर्दियों में गर्म और गर्मियों में ठंडा आता हैं।
@kalamazath93045 жыл бұрын
@@hemant3640 thanks bro
@Ground-Therm5 жыл бұрын
Temperature in the ground (1,7 m below the surface) is generally (in Europe) at the level of 4-12 °C
@kalamazath93045 жыл бұрын
@@Ground-Therm how it is possible to heat the air in winter?
@saxonsoldier675 жыл бұрын
@@kalamazath9304 All Year, the geothermal unit will maintain near the underground temp. The Earth will moderate the seasonal highs and lows.
@marcgatto9675 Жыл бұрын
Can this system be integrated with a heat pump?
@thomasschafer7268 Жыл бұрын
No.this ventilates. No heating. But you can use the energy from the old warm air for making hot water
@billnipp23095 жыл бұрын
so any outdoor orders will be sucked into your house. and the house would be very positive to the outside, which isnt such a bad thing.
@acoustic40375 жыл бұрын
The HRV would keep pressures equal. Same in as out. Its still crap, the ground loop will fill up with condensate
@plumsmuglers5 жыл бұрын
acoustic4037 atmospheric water harvesting 🐸
@forcedair92gt945 жыл бұрын
@ 1:35 filters are mentioned.
@koveebryant15265 жыл бұрын
What about mold inside the underground tubes Love the idea Hrv unit more practical imo
@Rohit909015 жыл бұрын
M Kovacevic 4:04
@basedbear16055 жыл бұрын
@@Rohit90901 Amazing how few people actually listened to the presentation, then immediately come here and ask obvious questions that were already answered.
@Avtowasya3 жыл бұрын
in such a ventilation system, a huge amount of condensation and bacteria is formed!
@zenonkoszorz96063 жыл бұрын
Inner layer of pips are covered with antibacterial agent (silver based). Condensation is collected and pumped out from condensation shaft.
@samuelboucher14543 жыл бұрын
Could you not attach air filters on the registers to solve this?
@mlionea Жыл бұрын
which company can offer this technology to an airport in UAE?
@gowrishankar73385 жыл бұрын
It could better explanation in video because we aren't understanding how ventilation systems work inside house. How air flow transferring outside inlet to inside house.
@saqlainmohiddin12804 жыл бұрын
I need mathamatical calculations like how long the pipes are used, how much energy is provided in one hour, how much time is required to heat or cool a room of 10*10 feet etc plz help
@jerryrodriguez93525 жыл бұрын
What’s the cost of this on a new construction home in Florida that’s 1500sq
@ananddixit95764 жыл бұрын
Please use live model to know whether it's feasible
@rajenderbattula99705 жыл бұрын
Great idea Please sir send me the system full details
@rizkiferdian24024 жыл бұрын
Obviously the same system of air ventilation in a bunker, underground space, panic room, etc. While I am here in a jungle having semi open spaces.
@felixromano30913 жыл бұрын
Is this the guy from epic economist ?
@mohitladdha85505 жыл бұрын
Is any presence in India ?
@plumsmuglers5 жыл бұрын
Where is THE UVC LIGHT to kill mold ?
@brettmoore31945 жыл бұрын
They used silver particles,impregnated in the inside of,the,ductwork . silver is,the worlds oldest and,most effective biological,remedy
@plumsmuglers5 жыл бұрын
Brett Moore well other than Sunlight, preventing mold on the inner surface is a good start.
@brettmoore31945 жыл бұрын
@@plumsmuglers not sure of your response but with the silver lining a electrostatic charge could be used,to prevent any dust buildup too
@plumsmuglers5 жыл бұрын
Brett Moore It would need that, because a coating would be nullified if any significant dust were allowed to build up on it, whereas UV Light is far more forgiving.
@brettmoore31945 жыл бұрын
@@plumsmuglers I,don't doubt sum,systems,were designed,to bring sickness. We have technologies that makes,the,jetsons look,like,cavemem
@a_balanced_perspective3 жыл бұрын
How to solve condensation in earth tubes this project?
@Ground-Therm3 жыл бұрын
Just by pumping it out from collector shaft or connection to draining to the sewage system.
@jawa56695 жыл бұрын
What about the in ground preheater and getting mold in the actual pipe under the ground guess this system has no longevity
@astranger4484 жыл бұрын
I built my own 15 years ago. Don't stop the airflow and slope the pipe to a lowest point, cut some slits there over a gravel drain. Also stay above groundwater level.
@MMaheshThakur5 жыл бұрын
This is very old technic I have seen it in one india palace. How to install it in our homes.how mux cose it will take
@georgekurian83355 жыл бұрын
Which palace in India
@JaspalSingh-rs7pz5 жыл бұрын
Please reply
@MMaheshThakur5 жыл бұрын
@@JaspalSingh-rs7pz what reply sir. there is nothing special in this.
@Cybernetic15 жыл бұрын
@@MMaheshThakur which place?
@basedbear16055 жыл бұрын
@@MMaheshThakur You were asked 3x. which palace did you see it in?
@Harman2701 Жыл бұрын
I want in india...do u have any dealer in india?
@harshpatel896 жыл бұрын
i want to install in my new bulid home give me proper idea .
@Ground-Therm6 жыл бұрын
Just send us (projekty@ground-therm.com) your demand for air volume or architectural design and land development plan. Then we can advice proper solution.
@harshpatel896 жыл бұрын
@@Ground-Therm sure i will sand is to you .
@adityapanwar48406 жыл бұрын
Pipes used are of what material
@mohdanfal50615 жыл бұрын
if i wanna install in my house what should I do
@myagmarjargalyondonjamts32353 жыл бұрын
Can i bury it under foundation,?
@zenonkoszorz96063 жыл бұрын
Yes, you can. Remember the soil have to be appropiately compacted.
@tombouie5 жыл бұрын
Hmmmmmmmm humidity will probably condensate against the cool inner pipe metal. Condensation within the pipes might cause microbe growth. UV lights might hinder microbe growth though.
@Ground-Therm5 жыл бұрын
No chance for microbs - all internal layer of tubes are protected with silver agent - anti-bacterial and anti-fungi.
@tombouie5 жыл бұрын
Hmmmm, this is an very ancient technology & numerous countries have looked at it in modern times. For example: Earth tubes as heat exchanger for geothermal ventilation / AC / cooling and heating passive house kzbin.info/www/bejne/omXRfqZ-pqiHm6s Microbes are absolutely everywhere & at best their growth might be retarded but never eliminated. Really, I can only assume the only practical reason why this technology is not used universally is the potential for microbe contamination. So I plan to use a flexible corrugated ducting (with anti-microbe coating, LED UV lights, etc) and simply make it removable/clean-able/replaceable/inspect-able/etc. Pls consider making your design open source (note there are many types of open source licenses; fossbytes.com/open-sources-license-type/). This allows folks living on a budget to potential use your system. Worry not, since rich folks are too busy/lazy to make your system for themselves, you'll still get tons of business especially in the US. If you manage your company well, cheap knock-offs won’t really hurt you much. Also being open source, you just might unite all the good work all over the globe in this area. There have been a lot of work. Here's open source in a nutshell: What is Open Source explained in LEGO kzbin.info/www/bejne/l2nJeZqubtJ4a7c
@НиколайШараенко5 жыл бұрын
Куда и каким образом девать конденсат ?
@michaeld9544 жыл бұрын
How much is this system and can it heat water
@thomasschafer7268 Жыл бұрын
No. For warming the air
@ursopolar6535 Жыл бұрын
Fantastic
@kohdefresh5 жыл бұрын
in Canada we have raccoons that like to break into EVERYTHING... so when one gets in and dies.. whose getting that out because of the smell going through the house lol
@astranger4484 жыл бұрын
Funny thing, this system is known the world round as a 'Puits Canadien/Canadian Well" Probably introduced by French Immigrants who call this a Puits(well) Provençale (which is the south of France). Maybe ask your neighbors how they deal with the occasional moose getting into theirs ;-)
@dwdfusion31385 жыл бұрын
Can this system work in desert countries
@Ground-Therm5 жыл бұрын
We are just preparing such systems for housing estate for over 1000 homes in Dubai.
@neeljain96194 жыл бұрын
@@Ground-Therm have you ever installed such system in India or if you have partner or representative in India. Please share some costing and investment figures for broader perspective?
@hunkpandey9283 Жыл бұрын
@@Ground-Therm plzz reply
@ExploringGenesis5 жыл бұрын
By Which software you make this video?
@__-pl3jg5 жыл бұрын
I visited the Ground Therm website. Turns out they just sell flexible plastic duct work and plenums. If you want a "mechanical ventilation" system you'll have to look elsewhere. What a disappointment.
@Ground-Therm5 жыл бұрын
Please take a look at our catalogue concerning GHE here: www.ground-therm.com/wp-content/uploads/2019/03/Katalog_GWC_v0.pdf . Additionally you can contact our design department: projekty@ground-therm.com, phone: +48 881 066 854
@ksatish005 жыл бұрын
Here the duct are not placed correctly
@Ground-Therm5 жыл бұрын
What you mean? All ducts or one? Which? Why?
@ksatish005 жыл бұрын
@@Ground-Therm the cool air ventilator from coil in the room should be in bottom level of room and hot air ventilator should be at top of the ceeling
@ksatish005 жыл бұрын
@@Ground-Therm actually I had project in my engineering on geothermal air conditioning unit
@imbbasp40475 жыл бұрын
Who keeps rodents out of dark environment pipes?
@vladstoica19463 жыл бұрын
a series of metal grates or something?
@TANVEER2011ify5 жыл бұрын
I am interested Hw I can install
@flatpancake11625 жыл бұрын
Tanveer Sate diy
@alifalawi5 жыл бұрын
Penerapan nyatanya di rumah2 indonesia sudah ada ga? Referensi dan laporannya ada yg tahu?
@meerasha20024 жыл бұрын
Is it wrok in india
@ksasiksanthreddy60734 жыл бұрын
Yes just maintain normal temperature throughout the year
@sumanm23265 жыл бұрын
Humans tends to close doors and windows only in case of outside pollution and dust. What is this idea of getting outside polluted air in to your home in a systematic way!
@astranger4484 жыл бұрын
Oh I also close them when it freezes outside.
@hanahmad42193 ай бұрын
So expensive...?
@thecriminallawyer25035 жыл бұрын
In rajasthan (india) outside temprature 45 and inside building 30
@thecriminallawyer25035 жыл бұрын
@A K its call aastha,,, and we have good manners ok ..lol
@pavelbaidurov2285 жыл бұрын
You all should build such systems at homes, it is faar cheaper than air conditioner in the long run
@3dakademikadircay5635 жыл бұрын
Beatifuul
@patmaker007 Жыл бұрын
Intellegent of ground HE. But it has very high of investment and maintenance cost.
@emulatorretro5 жыл бұрын
this is called a Baghdad air conditioner.
@cedvon48315 жыл бұрын
Brilliant
@RadRidesByCru5 жыл бұрын
Wait until one of those tube under the house gets a joint crack and the entire system fills with ground water.
@forcedair92gt945 жыл бұрын
There are negatives to all systems. Rodents in your attic eating through your AC tubing is equally as dangerous.
@RadRidesByCru5 жыл бұрын
I don't have rodents in my attic, and if I did, I can do something about it. All houses have water under them, nothing you can do about that. Nor can you do anything about the movement of the ground or your house. Nor can you repair this when it fails.
@astranger4484 жыл бұрын
Build above groundwater. It is a very essential piece of info before you get your shovel out. Slope the tubes, add drain slit at lowest point over gravel bed. This will get rid of the condensate. If groundwater happens (I have it very rarely if a winter is really wet) make sure that your lowest point has easy access, it pumps out in a minute with an ordinary garden pump
@GoTrack5 жыл бұрын
Veeru nice
@markusjordantesoro29928 ай бұрын
When bad person put a chemical to the intake air ventilation all the people inside the house inhale the chemical I think when you do this kind of ventilation make sure to hide the intake ventilation.
@dixieroad1232 жыл бұрын
Hello, how can I find the patent: "VENTIFLEX® PLUS was patented by us in 2013 (patent no. 405120" I was not able to find this patent with a GOOGLE search. US patent numbers from 2013 are 7 digits long. Where should I be searching? THANKS!
@vinerfahrtdinov50485 жыл бұрын
Непонятно автоматизация смешивания потоков
@genresong9525 жыл бұрын
Sir we have basement
@nurramlak11755 жыл бұрын
can you give subtitle indonesian...?
@sholykhan56135 жыл бұрын
how much cost
@GardenOrchid5 жыл бұрын
Great
@benkojr5 жыл бұрын
All good until the mold spores get sucked in!
@zenonkoszorz96065 жыл бұрын
Mold have no chance to grow - internal layer of all pipes are covered by silver agent - anti-bacterial and anti-fungi !
@astranger4484 жыл бұрын
Mold likes a quit place to grow, keeping the fan going all the time does the trick.
@adrianhugentobler33184 жыл бұрын
i really dont believe that it is nearly as 18c down in my yard..
@astranger4484 жыл бұрын
13C is common soil temperature, the uplift to 18 is by the heat recovery ventilation unit.