It's amazing that this channel makes it possible to practice straight away, making it very easy for us to work in the laboratory. Thank you🙏
@MicroChemsExperiments Жыл бұрын
Thank you
@OlufemiOlamoyegun6 ай бұрын
I have learn a lot through this your channel sir Thanks for bringing value to this noble channel. I appreciate your effort.
@MicroChemsExperiments6 ай бұрын
Glad to hear that. Thank you
@hassibahassani3903 жыл бұрын
I can never find someone explains better than you did . Thank you
@MicroChemsExperiments3 жыл бұрын
Hassiba Hassani, Awww, How sweet. Thank you so much for your comment. Be with us. ^_^
@adissugetahun18292 жыл бұрын
I really appreciate your effort for showing as such an amazing virtual lab. All the description was exactly in touch with each and every moments of the whole experimental framework. # as a reminder, please present as how wijs reagent is prepared in lab. Thanks.
@MicroChemsExperiments2 жыл бұрын
Okay. Thank you so much.
@hernandorodrigues9259 Жыл бұрын
@@MicroChemsExperiments Como saber se o carvão ativado está acima de 800% de iodo
@giaohuynh5884 Жыл бұрын
Thanks for your wonderful and passionate video. It's really useful for my work. I wonder some point that could you explain for me, please. 1. Why we certain use Carbon Tetrachloride in this experiment. Can you explain in detail the reason why you use Carbon Tetrechloride? Can I replace it by other substane? 2. I wonder if you put Potassium Iodide crystal around the stopped? Why don't we use the solution of Potassium Iodide? 3. In the phase that you pour distlled water into the flask, you titrate the flask with Sodium Thiosulfate until the yellow is lighter before you add the starch solution in the flask. So I wonder the reason why you must to titration before adding the starch solution. Is there any theory in this phase? I really want to know. I truly appriciate your support and I am looking forward to hearing from you. Many thanks
@esraamossad39703 жыл бұрын
This is the best channel I have ever seen, thanks for your effort ❤
@MicroChemsExperiments3 жыл бұрын
Thank you so much. Where are you from Ma'am, may I know?
@esraamossad39703 жыл бұрын
@@MicroChemsExperiments Egypt
@MicroChemsExperiments3 жыл бұрын
@@esraamossad3970 You can contact us in Facebook also. Link is given in the description section.
@esraamossad39703 жыл бұрын
@@MicroChemsExperiments I have already followed you on Facebook, thanks MicrChem ✌
@MicroChemsExperiments3 жыл бұрын
@@esraamossad3970 Thank you Ma'am. Stay with us.
@ouamroucheamel351920 күн бұрын
Thank you for all, I have a question, please what represent 12.69 in the formula?
@cna803 жыл бұрын
Great presentation! Please continue the good work. Knowledge is for sharing.
@MicroChemsExperiments3 жыл бұрын
Thank you so much. Stay with us.
@hotsquarrel Жыл бұрын
How to prepare wij's solution?? 50ml iodine monocloride desolved in how many acitic acid in ml?? Please🙏 reply
@nuralamsiddque66293 ай бұрын
Thanks for sharing with us your valuables information
@MicroChemsExperiments3 ай бұрын
You are most welcome
@greatlearningwithgsb53779 ай бұрын
All tests which i need in solvent plant laboratory testing, all tests are there on your channel thank you so much
@AbhishekSharma-mo3nb3 жыл бұрын
1. Quality testing of raw as well as finished products of confectionary. 2. Preparation of: 1. candies, 2. Caramel, 3. toffees. 3. Collection of various types of confectionary packages. 4. Determination of sugar in confectionary product by saccharometer. 5. Determination of refractive index of sugar - solutions of different consistencies
@AbhishekSharma-mo3nb3 жыл бұрын
Pls make vedios on this tests
@MicroChemsExperiments3 жыл бұрын
Okay.
@AbhishekSharma-mo3nb3 жыл бұрын
Thank you so much
@MicroChemsExperiments3 жыл бұрын
@@AbhishekSharma-mo3nb you are most welcome
@mimosaya4462 Жыл бұрын
Thank you for this vid. I just want to know, how do you handle these chemicals as waste after the analysis?
@MicroChemsExperiments Жыл бұрын
We have third party company to handle this
@yue00 Жыл бұрын
Hi love the video!Just wanted to ask why put the flasks in dark for 30 min?will the time of this have an effect on the titration?
@MicroChemsExperiments Жыл бұрын
This is done to allow reactions of some light sensitive chemicals.
@pedromiguelestevezdeleon6272 Жыл бұрын
Hi MicroChem´s, can i make this determination of iodine value in activated carbon??
@plutoisnotaplanetbutadwarf Жыл бұрын
Hi, thanks for making this video! It is really helpful. I have been doing my experiment about how the number of times heating the corn oil till boiling will affect the oil’s iodine value and I realized that as I did titration, there was a layer of oil-like solution at the bottom of the flask. Do you know anything about this and why does it happen? Because it has became really obvious and disturbing since the oil darkened as the heating number increased.
@Titi-je3ff3 жыл бұрын
Before do any lab experiment i search it your channell.it is very usefull to me. Though i get wuections😉😊😊😊😊
@MicroChemsExperiments3 жыл бұрын
Kasthuri Kk, It's our pleasure ^_^ We are planning to make videos for almost every laboratory tests. Just be with us.
@rahmatullasaikalgar-zd8ou Жыл бұрын
Nice good explanation,i have one question,Why we kept sample in a dark place for exact 30 minutes.
@MicroChemsExperiments Жыл бұрын
To allow the chemical reaction satisfactorily that could be halted in sunlight
@SURESHKANTIWAL Жыл бұрын
I watch iodine value analysis video many time.which is very good & clear.but i want to know without putting iv flash in dark test can be done?
@MicroChemsExperiments Жыл бұрын
Putting iv flash in dark is necessary
@beverlytompkins3017 Жыл бұрын
hi , I enjoyed the video but shouldn't the sample amount been pipette out instead of poured in because the majority of the sample was on the side of the flask not at the bottom
@asthajain45743 жыл бұрын
You are just superb!! Can you plz make a video on sugar determination from carbohydrates...i mean fehling solns..at which point we can consider the end of the titration.
@MicroChemsExperiments3 жыл бұрын
Astha Jain, Thank you. We have already started making video for Sugar determination. Stay with us.
@zekariaslibena59509 ай бұрын
it's good job.thank you very much
@lakshmanubodireddy27632 ай бұрын
Can you share determintion of startch acid hydrogen method
@Titi-je3ff3 жыл бұрын
Who the hell disliked. Idiots...perfect demonstration. Pls low noice back ground sound adjust. We lv your channel.thanks. plc to hplc aflatoxin analysis
@MicroChemsExperiments3 жыл бұрын
@Kasthuri Kk, Ha ha ha...1 dislike among 89 like is negligible. They have rights to express their opinion. So plz don't argue with them who disliked. What you can do, you can love the channel more & more. We will make the background sound lower from the next video. Which aflatoxin (among B1, B2, M1,M2,G1or G2) do you want video for?
@Titi-je3ff3 жыл бұрын
B1,B2,G1,G2 now im currently initiatimg in my lab sri lanka.if you can pls do other also.it will be really usefull.u guys are amizing.
@MicroChemsExperiments3 жыл бұрын
@@Titi-je3ff Okay. We will make it as early as possible. Thank you for your comment.
@arefinkhanom9157 Жыл бұрын
Thank you so much for your important video❤❤❤
@MicroChemsExperiments Жыл бұрын
It's my pleasure
@rickpalmer3041 Жыл бұрын
Hi. Why did you not add 10-15% KI b4 stopping with water? Thank you!
@newsofislam1284 Жыл бұрын
You can add 10% KI solution 15 ml into flask,
@نور-ذ5ع9و3 жыл бұрын
It was great work. I have a question? Will there be any problem if I use saturated KI solutions?
@MicroChemsExperiments3 жыл бұрын
You can use saturated KI solution
@نور-ذ5ع9و3 жыл бұрын
@@MicroChemsExperiments ♥️♥️♥️
@نور-ذ5ع9و3 жыл бұрын
@@MicroChemsExperiments Can you give me your number, please?
@MicroChemsExperiments3 жыл бұрын
@@نور-ذ5ع9و knock in our Facebook page. Link is given in the description section
@reformlabs8742 Жыл бұрын
Very useful information, however one issue tho, you do not heat a Volumetric Flask!
@MicroChemsExperiments Жыл бұрын
Noted
@Kindly_Her Жыл бұрын
Can please ask why are we still multiplying with normality if we have converted to mass already?
@nezzariazzeddine250911 ай бұрын
Can you guide me how to calculate ! Especially the blank thinks
@brianshim49613 жыл бұрын
Hello, may i ask what were the molarity of the Wijs solution and carbon tetrachloride used here? I would like to see how i can change the calculations if i am using different concentrations
Hi, thank you for the video! But I have a question. What is the purpose of adding potassium iodide crystal? And can you quantify the amount of potassium iodide crystal added around the surface of the stopper? I'm a student planning to do this experiment in schoolwork.
@MicroChemsExperiments Жыл бұрын
Potassium Iodide helps to release Iodine. You can add 500mg into the flask
@IvyLin-is8bi Жыл бұрын
@@MicroChemsExperiments Thank you!
@malithaniman17302 жыл бұрын
Thanks. Was helpful for exams in my masters Thanks a lot
@MicroChemsExperiments2 жыл бұрын
Thanks
@3DCadDesignCombo Жыл бұрын
Informative video tutorial.
@MicroChemsExperiments Жыл бұрын
Thanks
@blackbirdchannel9511 Жыл бұрын
Ma'am I have a simple question what is purpose of this test or what does tell us this test?
@foodlaboratory8079 Жыл бұрын
Calcium magnesium phosphorus ka bi video bnao mam
@narasimhamuppala90453 жыл бұрын
Thanks for your knowledge sharing... please make a video on "urease activity of soya bean meal"...
@MicroChemsExperiments3 жыл бұрын
Ok...we will do it soon. Stay with us.
@swetarawat3624 Жыл бұрын
plz also give the reason behind adding any chemicals in the given experiment .
@aksaniamorris30423 жыл бұрын
This was great work. One question, wouldn't the KI crystals placed on the top interference with the reaction?
@MicroChemsExperiments3 жыл бұрын
Aksania Morris, thank you for your comment. No, Addition of KI wouldn't interfere the reaction. In AOAC it ia said to add KI.
@aksaniamorris30423 жыл бұрын
@@MicroChemsExperiments ok thank you
@MicroChemsExperiments3 жыл бұрын
@@aksaniamorris3042 Welcome. Thanks for being with us.
@Cookie-wt4uz2 жыл бұрын
Actually the KI helps to liberate the unreacted I from Wij's solution
@newsofislam1284 Жыл бұрын
@@MicroChemsExperiments You can add 10% KI solution 15 ml into flask,
@haceroo7 ай бұрын
Iodine molecular weight is 126,90477 g/mol . Why was this (12,69 g/mol ) written in the formula?
@amanueldaniel53423 жыл бұрын
Thank you for sharing. may ask question why add KI at neck of flask when during preparation of sample and blank?
@MicroChemsExperiments3 жыл бұрын
It is said to add in AOAC.
@umeshyadav-xj2uz2 жыл бұрын
@@MicroChemsExperiments 👍👍
@waytohellgamers52012 жыл бұрын
Bcoz iodine vapours doesn't go outside of iodine flask
@newsofislam1284 Жыл бұрын
You can add 10% KI solution 15 ml into flask,
@SohelRana-ln7bg3 ай бұрын
Stearic acid iodine value test is same??
@hamzamansour593 Жыл бұрын
What an excellent explanation ❤❤ thank you so much
@MicroChemsExperiments Жыл бұрын
Thank you
@rajesh79993 жыл бұрын
Its It's very good to see experiment very clearly I have thought our chemists by showing the video... many thanks... Please update USM UNSAPONIFICATION MATER ALSO
@MicroChemsExperiments3 жыл бұрын
NUTHAKKI RAJESH, okay we will work on unsaponification mater as early as possible. Be with us.
@rajesh79993 жыл бұрын
@@MicroChemsExperiments thanks
@MicroChemsExperiments3 жыл бұрын
NUTHAKKI RAJESH, This video will help you. Please take a look. kzbin.info/www/bejne/eqHKnnuuYsmfZ6M
@kapilmaurya826210 ай бұрын
Blank me starting me kya liya tha befor adding ccl4
@sonandpets12153 жыл бұрын
Where can I buy or how can I get the AOAC manual for the different methods? I'll still keep watching you! 🙏🐾
@MicroChemsExperiments3 жыл бұрын
You can purchase it from Amazon.
@bishow87812 жыл бұрын
Full meaning AOAC
@muhammadaltaf96513 жыл бұрын
Appreciate your effort on preparing such useful videos.
@MicroChemsExperiments3 жыл бұрын
Thank you very much. Stay with us.
@AbhishekSharma-mo3nb3 жыл бұрын
Thank you so much Is 12.69 molecular weight of iodine?
@MicroChemsExperiments3 жыл бұрын
No. Molecular weight of iodine is 126.9. Its a calculation factor which was derived using the molecular weight of iodine.
@AbhishekSharma-mo3nb3 жыл бұрын
Thank you 😊
@MicroChemsExperiments3 жыл бұрын
@@AbhishekSharma-mo3nbMost Welcome
@rajatsharma87369 ай бұрын
0.21 gm sample h to expected iv groundnut oil me kitna hona chahiye
@nadiaqonita82103 жыл бұрын
thank you for making a test video tutorial like this. the video is very clear and easy to understand. It's just that there are some points that explain it too quickly, so I feel that there is something missing, but it turns out that the explanation is just too fast.
@MicroChemsExperiments3 жыл бұрын
@Nadia Qonita, You are most wecome and thanks to you for your observations. We will try to make our videos more clear.
@rickpalmer3041 Жыл бұрын
If the blue color keeps coming back within the 30s, what could be the problem? Right after turning milky-white, the blue color returns. This happens repeatedly even after titrating more of the thiosulfate
@AayushiSain-s3g10 ай бұрын
Which oil u have used in this pls tell
@yue00 Жыл бұрын
Also when I carry out the procedure, there is a purple coloured layer at the bottom of the solution in the blank and a pink coloured in the sample, do you know anything about this?
@MicroChemsExperiments Жыл бұрын
Nothing noticed like that. Prepare chemicals and reagents freshly and try it again
@janamaymagpayo74192 жыл бұрын
hello! what is the solvent used fir wij's solution? can water be used?
@MicroChemsExperiments2 жыл бұрын
use acetic acid as solvent
@Ghost3412110 ай бұрын
Can you please help me with a soft copy of the method Thanks
@lakshmanubodireddy27632 ай бұрын
Please share how prepare of wijs solution
@ukuleilei49052 жыл бұрын
1. During titration, iodine flask should've been covered with the stopper throughout in order to avoid the escape of iodine gas. 2. calculation should've shown the units also 3. It should've been 126.9 g/mol, since that is the molecular weight of iodine.
@daniellekeller3712 жыл бұрын
Regarding 3.: Yes, but you have to divide by 10 to get the correct unit for the IV, which is g(I2)/100g(fat). It would have been obvious, if the correct units were used in the video.
@MicroChemsExperiments2 жыл бұрын
Noted
@HassanDanish-vh2zu4 ай бұрын
There's a mistake in your analysis the equivalent weight of sodium thiosulfate is 248.16g so if we want to make 0.1 N Sodium thiosulfate we need 24.6g not 2.48 g
@arknowledgezone7741Ай бұрын
your calculation is for 1000 ml, but here 100 ml sod. Thiosulfate is being prepared by using 2.5 gm of it, which is correct.
@HassanDanish-vh2zuАй бұрын
@@arknowledgezone7741 Thank you ! for correcting me, its my bad
@manojkumarsharma617714 күн бұрын
Dear sir mujhe ye nahi samajh m aaya aap ne blank m oil liya ya nahi
@MohammedQatan-c3v8 ай бұрын
Ihave iodine mono chloride in the labe but if iuse it it doesnot give me the good reading for the blank low readeing what can ido any way to increse the wigis solution strength
@kavindibalasinghe81442 жыл бұрын
Hi could you please let me know any alternative for CCL 4 ( apart from chloroform ). Thanks
@MicroChemsExperiments2 жыл бұрын
No replacement to be known for CCl4 other than Chloroform
@kavindibalasinghe81442 жыл бұрын
@@MicroChemsExperiments thanks alot for the reply
@s.m.armanhossen4478 Жыл бұрын
thank you
@MicroChemsExperiments Жыл бұрын
You are welcome
@Sathish8300m2 жыл бұрын
i have prepare Wij stock solution using 50g ample in 500ml (makeup)acetic acid and for working solution i have take 80ml of stock solution and makeup with 500ml of acetic acid is this correct
@MicroChemsExperiments2 жыл бұрын
We will make video for the presentation of wijs solution soon
@sondesalmbrok1622 жыл бұрын
Thanks for the video, But if result 38 for olive oil and compared with reference rang and show less than from rang what writing comment?
@MicroChemsExperiments2 жыл бұрын
The quality of that oil is not good and maybe mixed with other cheaper oil.
@aqeelasif70325 ай бұрын
What is the unit.? Of IV in this calculation.?
@nhuguyenn2 жыл бұрын
Hi, what's the concentration of wij's solution did you use?
@MicroChemsExperiments2 жыл бұрын
1.623%
@kinanujeremiah18233 жыл бұрын
I like your explanation and demonstration Thanks
@MicroChemsExperiments3 жыл бұрын
Thank you too. Stay with us.
@leenziad5964 Жыл бұрын
Good job ❤❤ One question where did the value 12.69 come from ?
@ashishshrivastv8375 Жыл бұрын
126.9( mol wt of I) divided by 10
@arshyankhan205411 ай бұрын
@@ashishshrivastv8375why divided by 10?
@digitechsports69422 жыл бұрын
Please how to prepare Ipa lactic acid solution for sv test of wheat flour.
@MicroChemsExperiments2 жыл бұрын
Did you mean sedimentation test of wheat flour?
@rebeccahmbithe30242 жыл бұрын
I have been given unknown kind of fat or wax maybe but the point is this sample is in solid nature, how will I predict it's Iodine value so that I'm able to weigh the supposed weight of the sample?
@MicroChemsExperiments2 жыл бұрын
Go for the first trial taking any amount of sample which will give you an idea about the iodine value (approximate). After getting the idea, go for the second and final trial taking sample weight according to the iodine value you got from the first trial
@moonlight-td8ed2 жыл бұрын
can u pls tell the precautions needed??
@MicroChemsExperiments2 жыл бұрын
Prepare chemicals freshly
@poonamprisha14103 жыл бұрын
At the end point pink color emulsion kya usko bhi milky bnana h
@MicroChemsExperiments3 жыл бұрын
Milk color emulsion along with white solution will form at the end of the titration.
@Itsmenandana8082 ай бұрын
How much ammount of KI adding?
@phenolicphtl50112 жыл бұрын
My question is not about AOAC but about AOCS methods, that before weighting the sample, sample must adjust temperature to 68 -71 celsius deg. I wonder what is the purpose of sample temperature adjusting?
@MicroChemsExperiments2 жыл бұрын
Chemistry is all about chemical reactions. Chemical reactions takes place differently at different temperatures. So the adjustment of temperature is very crucial for any chemical analysis of sample.
@ekingursoy17793 жыл бұрын
Hi, I was wondering why is it so important that it should be closed immediately after pouring the wij's solution. By the way, this is a great video it has helped me so much. If you have any other papers, videos, or references about determining iodine value in oils by wij's method I would be thrilled If you could reference it. Again thank you.
@MicroChemsExperiments3 жыл бұрын
Ekin Gursoy, Thanks for your comment. Actually, when Wij's solution is added, it reacts with Iodine present in the sample to form slightly volatile compound. If we left open then loss of iodine may occur. That's why we keep the flask closed immediately after adding carbon tetrachloride and Wij's solution. Other two references for this test are: IS-548 and FASSAI MAnual.
@ekingursoy17793 жыл бұрын
@@MicroChemsExperiments thank you very much
@MicroChemsExperiments3 жыл бұрын
@@ekingursoy1779 You are most welcome.
@khemist26313 жыл бұрын
@@MicroChemsExperiments Great video, very interesting to watch. However, why was the iodine crystals added around the stopper after closing?
@MicroChemsExperiments3 жыл бұрын
@@khemist2631 It is added to set a barrier for passage of gas from the flask to the outside during the 30min of the reaction time.
@anannaone Жыл бұрын
this was so well explained💝
@MicroChemsExperiments Жыл бұрын
Thank you
@swapnilpradhan5072 жыл бұрын
Very informative video
@MicroChemsExperiments2 жыл бұрын
Glad you think so!
@amirazaharuddin3463 Жыл бұрын
For the blank , we should to find iodine value also ?
@MicroChemsExperiments Жыл бұрын
Not iodine value actually. Blank reading represents the chemical error for iodine value test
@oshinmanchu2 жыл бұрын
Hi Mam Is it possible to analyse cholesterol content in edible oil by volumetric titrations..??? Without chromatography or spectroscopy plzz reply me mam...
@MicroChemsExperiments2 жыл бұрын
We will upload video later.
@Athokshaya_V Жыл бұрын
What is filter paper number used to prepare 1 percent starch solution?
@MicroChemsExperiments Жыл бұрын
Number 1
@Athokshaya_V Жыл бұрын
@@MicroChemsExperiments can we use whatman no. 4 filter paper?
@surendranathsingh8040 Жыл бұрын
Thanks
@MicroChemsExperiments Жыл бұрын
Welcome
@azaruameer39312 жыл бұрын
can i use these methods in my food quality lab of my food industry?
@MicroChemsExperiments2 жыл бұрын
No. This method is only for oil sample.
@azaruameer39312 жыл бұрын
@@MicroChemsExperiments our industry make olive oil only
@biancaysabelvicente2153 жыл бұрын
Hii! first of all, your videos are very helpful. But may i ask something, why is blank titration necessary in the this determination(iodine value det.)? I hope you answer me ,thank you so so much
@MicroChemsExperiments3 жыл бұрын
Blank titration is needed to subtract reagent reading.
@biancaysabelvicente2153 жыл бұрын
@@MicroChemsExperiments Thank youu Ma'am/Sir.
@MicroChemsExperiments3 жыл бұрын
@@biancaysabelvicente215 You are most welcome.
@sahilrohilla38633 жыл бұрын
Heyyy , i can help you in your exams and assignments . I am a medical expert.
@rohanbandechha90812 жыл бұрын
what does the potassium iodide do, is it needed for the experiment
@MicroChemsExperiments2 жыл бұрын
Yes. It is needed
@sonandpets12153 жыл бұрын
You are awesome! Thank you for sharing!
@MicroChemsExperiments3 жыл бұрын
Thank you for supporting us.
@poonamprisha14103 жыл бұрын
Mam jo dark m rkhte ho vo only 30minutes which type of dark you use plzz tell
@MicroChemsExperiments3 жыл бұрын
I used cabinet where no light can enter.
@subhadevisubhadevi851727 күн бұрын
In this calculation step12.69 value where itcomes from
@azaruameer39312 жыл бұрын
Can you give me the "Determination of Oil Analysis" manual if I need it?
@MicroChemsExperiments2 жыл бұрын
We do not provide any document
@MohdUsman-tq6gk2 жыл бұрын
Why don't we add starch indicator in the beginning of titration? What only when the colour of the solution becomes lighter?
@MicroChemsExperiments2 жыл бұрын
It is a two spet titration. More accuracy is achieved by adding starch when the colour is faded out.
@amtknh9 ай бұрын
i took 0.216 gm sample of groundnut oil its value came 93. isit in expected iv range or this answer is wrong
@dilani25-gu6qj11 ай бұрын
Why uou mention 12.69 Can You explain plz
@anuragchoudhary79443 жыл бұрын
Nice explained. How do we calculate iodine number for activated carbon.
@MicroChemsExperiments3 жыл бұрын
Same calculation should be applied
@anuragchoudhary79443 жыл бұрын
@@MicroChemsExperiments what should the weight of active carbon for the experiment
@MicroChemsExperiments3 жыл бұрын
@@anuragchoudhary7944 Use 5g sample.
@anuragchoudhary79443 жыл бұрын
@@MicroChemsExperiments thank you
@benoysebastian8112 жыл бұрын
Please post a Video for Determination of TVBN in Dried Fish Meal sample AOAC
@MicroChemsExperiments2 жыл бұрын
Noted
@dixitkansagara7441 Жыл бұрын
I have 2-3 questions,how can i contact you? Plz ans..
@MicroChemsExperiments Жыл бұрын
Already answered. Do this test exactly as done in this video
@AJInfoBook2 жыл бұрын
Can we use of chloroform instead of Carbon tetrachloride
@harshitakaushik90582 жыл бұрын
Yes, you can
@AJInfoBook2 жыл бұрын
@@harshitakaushik9058 thanks
@MicroChemsExperiments2 жыл бұрын
Thanks for the reply
@user-df5is8jy6n3 жыл бұрын
what is the difference between this method and ASTM D4607-94 method? Can I use this method for activated carbon?
@MicroChemsExperiments3 жыл бұрын
No. Our method is for foods and oils. We will prepare method for activated carbon later. Stay with us.
@user-df5is8jy6n3 жыл бұрын
@@MicroChemsExperiments oh thank you very much, looking forward to it.
@MicroChemsExperiments3 жыл бұрын
@@user-df5is8jy6n Welcome.
@shibora5 ай бұрын
Where Didi you get this 12.69
@Babyvideos7112 жыл бұрын
If we don't know iodine value limit of any sample then how much weight should we have to take for calculating I.V.
@MicroChemsExperiments2 жыл бұрын
You can get idea of iodine value for specific oil from google and journals.
@amtknh9 ай бұрын
for groundnut oil what weight we should select @@MicroChemsExperiments
@kushagrasharma8915 Жыл бұрын
Can you please tell me the chemical equation for this reaction.
@MicroChemsExperiments Жыл бұрын
We will make video later for every test explaining chemical equation
@blackwhite3463 Жыл бұрын
In here which is value of 12.69???? How u find it?m
@MicroChemsExperiments Жыл бұрын
It is a calculation factor given by the reference method of AOAC.