Didn’t envy you one bit on that, had similar experience’s over the years. Building inspector’s used to be ex carpenters or brickies years ago so had a lot of site experience, the inspector’s of today are all taught from books not from experience and as you said what makes sense.
@brianc8277 Жыл бұрын
I have never been comfortable with bends in drains below buildings. I would have mede the pipe below the extension straight and then made changes in direction outside of the extension with the use of a double inspection chamber. A more expensive solution but a much safer outcome. I have done it many times before when all drainage was controlled by the local council. Rtired BCO
@SkillBuilder2 жыл бұрын
A couple of years ago Thames Water wanted clay drains replaced with clay, and brick built inspection chambers, Just imagine the ball ache on a job like yours. They now allow plastic provided it is the heavy duty pressure jetable type. If the can jet it without blasting a hole in it they are not worried about the blind bends.
@Mr_A_Builders2 жыл бұрын
Oh man! What a nightmare that would have been! Thank goodness common sense prevailed l! Hope you're all well, we're all obviously massive fans of yours. Take care.
@foundthetruth2003 Жыл бұрын
My goodness!!..I don’t envy you boys on that one, well done.
@videogalore2 жыл бұрын
Well worth getting a water kit for that Stihl saw, keeps the clients, neighbours and you and your team happier!
@Mr_A_Builders2 жыл бұрын
I'm hearing you mate.
@dantonk110 ай бұрын
I’m with this guy, google silicosis - please wear a mask and use dust suppression when cutting concrete - silicosis is the asbestos of today’s age. Take care of your lungs mate. enjoyed the video as I’ve some drainage work coming up….@@Mr_A_Builders
@dave38x4 ай бұрын
Just about to do something very similar on my extension, thankfully STW happy with my plans. Got a little bit more space to next door which makes life easier. Building inspector coming around Monday to discuss plans before I dig out too much more!
@markjarvis97802 жыл бұрын
Rainwater into a main drain. Building inspector would have a heart attack round by me if they saw that 🤣
@Mr_A_Builders2 жыл бұрын
Haha! Really? It's just not an issue round here at all.
@stevenartmann26422 жыл бұрын
Most old buildings are on combined systems, can't do it on new builds though
@lewisbrand2 жыл бұрын
That is not true. Soakaways need to be 5 metres away from any building or property boundary, and in most built up areas there is insufficient space to accomodate this, so using the sewer ( if there is no separate surface water system available ), is the only option.
@dee106ful2 жыл бұрын
@@lewisbrand He is actually right in certain boroughs you have to have them separate and build a manhole to cater.
@edcork1479 ай бұрын
Wether it’s right or wrong this is why sewers become overwhelmed and discharge into our rivers.
@Chris-eh9eg2 жыл бұрын
Great video, really interesting! 👍🏻👍🏻
@Mr_A_Builders2 жыл бұрын
Thank you Chris, really appreciate that matey.
@TA-wg9oi2 жыл бұрын
Thanks for your videos mate. It brings back memories of my time working in the UK. After I completed my carpentry apprenticeship in Australia, I traveled and lived in Nuneaton from 1980 and worked in Rugby and Leamington Spa. I joined with a brickie and would do extensions same as your current project...although we didn't have the red tape from local councils back then but remember cutting out the clay pipes for new PVC ones.. I also remember re-slating a cottage roof in Leamington Spa only to find out all the rafters were tree branches.... On return to Australia in 1986..the start of the cordless era, I completed the Townsville Breakwater Casino, Mirage Resort, Gold Coast and 80 Defence houses at the Tindal AF base in Katherine NT. Currently have a concrete trucking business.. and interesting to see you use a volumetric concrete truck not an agitator. Looking forward to your stage 4 video..
@paulryan157811 ай бұрын
All you needed at that bend was a inspection riser screw capped for future use
@Mr_A_Builders11 ай бұрын
Hello Paul. Unfortunately mate that wouldn't have worked.
@Lambretta-images2 жыл бұрын
Simple rule, any change of direction in foul run requires an inspection chamber. It would have been simple to remove the old manhole and run the foul straight to a new inspection chamber in the original hole that had been dug.
@Mr_A_Builders2 жыл бұрын
That simply wouldn't have worked. There just wasn't room on the plot.
@leeyo5494Ай бұрын
@@Mr_A_Builders hi when people remove a manhole and fit the new round style inspection chambers, how do they rod them when they get blocked, they dont look wide enough to get the rods down and round into the pipes?
@Mr_A_BuildersАй бұрын
@leeyo5494 hello lee, the inner diameter of these plastic pipes are actually greater than the clay ones, so there's no issues with ridding them.
@seanmccormack8566Ай бұрын
He's dug the hole to the side of the pipe outside the footing....all he had to do was was extend it into a new manhole then change direction 🤔.
@paulsyms87072 жыл бұрын
When you was going through the options at the beginning the one that you did made perfect sense..I couldn't fathom out why the water board didn't like your plan . Obviously got someone who knows what they're doing.. great job in shit conditions by the way
@Mr_A_Builders2 жыл бұрын
Thank you Paul! Appreciate that mate.
@patrickquill46562 жыл бұрын
Well on all of the team Hard going in wet weather Job done 👍
@Mr_A_Builders2 жыл бұрын
Thank you, Patrick.
@rogerphelps993910 ай бұрын
We had the same problem with an inspection chamber which our architect proposed we build over. That was turned down by Wessex water and we had to extend pipes so that the the chamber could be located outside the extension. It also needed a new inspection chamber to cover a 90 degree bend and the fall in the new sections is now pretty small.
@AdamRayan-u5xАй бұрын
Great video and informative…..
@michaelsmyth32602 жыл бұрын
Good series this. Thanks for taking the time.
@Mr_A_Builders2 жыл бұрын
Thank you Michael! Appreciate that mate!
@euanjt309 ай бұрын
Just finished our extension in Scotland & the problems caused by drainage/sewers pipes coupled with building on a slope 😂 the guys had to dig 8 foot down to run the pipes - nightmare !! Like a ww2 bomb had gone off and left a crater. Totally worth it with the end result 🎉
@digdugdan2 жыл бұрын
Enjoyed that one. You never have much of a break on that job, with the weather or some problem. Glad its sorted. I'm surprised the building inspector has authority to tell you to connect rainwater into the sewer. Where I am, its not allowed, and it's the water company that prohibit it, nothing to do with the council.
@teach19132 жыл бұрын
Exactly, shouldn't be allowed just leads to sewage discharge into rivers as after heavy downpours the sewage works overflow with majority wastewater and have to release it all
@terrywallis6932 жыл бұрын
Im surprized as its an extension the Planning/BI didnt instruct a soakaway for the additional roof area. Furthermore the "new" connection on a branch isn't best practice as its not jettable from an external manhole.
@terranceyeo30872 жыл бұрын
I'm a specialist serwerman and working for the Severn Trent and no way would I allow surface water going into the foul, the only way would be if the property is pre-37 and have a joint foul and storm, I would chek before backfilling.
@Mr_A_Builders2 жыл бұрын
Hello Terrance, hope you're well. It's all been checked and we have written permission. It's just not an issue with the authorities round this way. Most of the houses all have their rainwater go into a combined system including this one which also had it's detached garage go straight into it. Appreciate your comment mate.
@jonost242 жыл бұрын
Just watched the end. Sense prevails.
@Mr_A_Builders2 жыл бұрын
Thankfully!
@chriscollins17042 жыл бұрын
Thats good. You can start getting it out the ground now if you don't get froze off. If they squinnied about the change of direction, I suppose the only other thing would be 2 ic's. One to get it out the building and go 90 degrees and then one to get back on course. It's all academic now. Like I mentioned before, southern water would have us do all that in clay and probably the Chambers would be 9 inch English garden wall bond, red engineering
@pedtrog64432 жыл бұрын
Wrap a piece of stiff paper or card around the pipe and align the edges and you'll mark a perfectly square cut line.
@ComeWhatThey2 жыл бұрын
Can't catch a break with this job. Remember watching a Gosforth Handyman video doing something similar with his extension, think he replaced all the pipe on the property with plastic. But that's the sort of thing it's easy to justify in nice weather. I'd be interested to hear how they described that "alternative" they proposed that you couldn't make heads nor tails of.
@darrenthebuilder Жыл бұрын
Tough job but you did it 👍🏾
@Mr_A_Builders Жыл бұрын
Cheers Darren. How's that nightmare job going? Hope you're well mate.
@roybatty46872 жыл бұрын
Existing is having an accessible inspection chamber close to the blockage prone bend so it can be rodded.
@DocteGaby2 жыл бұрын
Started watching recently at stage 1 of the extension. I can feel your frustration but also applaud your willingness to do things the right way with all the constraints. It's so hard to find good honest builders these days, it's refreshing. Shame you can't film everything when you have to crack on with things. I wonder if you could just get a phone on a tripod and leave it on a time-lapse? Not sure how much more editing work that would be though...
@Mr_A_Builders2 жыл бұрын
Thank you DocteGaby. Thank you for watching our videos, hope you like the others coming up.
@johnriggs49292 жыл бұрын
Looks like a hell of a difficult job, made ten times worse by the weather, as always. I once had to dig down eight feet to build a back drop manhole on a 6" live drain, with 4 foot concrete rings. I was sliding about in wet clay for 3 days, soaked to the skin. Yorkshire Water passed it eventually, and within an hour, the rain stopped and the sun came out. Did the building inspector/Severn Trent Water pass it?
@Mr_A_Builders2 жыл бұрын
Hello John, hope you're well mate. Yes it's all been passed, thankfully! It's amazing how the weather can improve as soon as you've finished isn't it!
@jimgardner90442 жыл бұрын
Trying to deal with seven Trent is like banging your head against a brick wall, Once you can get a guy out to have a look common sense kicks in.. my problem went away in five minutes. Cheers Jim in NZ.
@Mr_A_Builders2 жыл бұрын
Hello Jim, appreciate your comment mate. I must say it echos my experience! Hope you're well.
@charlescoulson2 жыл бұрын
You sometimes wonder whether this is meant to happen when even the weather is against you. Bloody nightmare! So glad to hear the the water folk saw sense in the end. I just hope you managed to sleep ok through all that, I know I have had many a disturbed night when my silly brain will not let me rest. Mind you I have often found a solution in the middle of the night!
@Mr_A_Builders2 жыл бұрын
Hello charles, yes I've had a few light bulb moments in the middle of the night! I must admit I was worried about this one, the alternative was so detrimental to the customers wishes. Thankfully it all worked out alright in the end!
@Doug....2 жыл бұрын
Got over that prob without loosing your rag 👍👍😂
@semperidem25772 жыл бұрын
'Another one for the list' I love it.... I've got a spreadsheet 😁
@Mr_A_Builders2 жыл бұрын
Haha! My list is long and not exhaustive!!!
@colinmiles1052 Жыл бұрын
You did well! Great video. Water Companies seem to be a law unto themselves.
@Mr_A_Builders Жыл бұрын
Thank you, Colin. They do don't they! Hope you're well mate.
@MrJonah532 жыл бұрын
When I was working, (erecting steel) we were on a job where we had to erect over the old factory. One of our columns inside was right next to the toilets, and of course the soil pipe was in the way. We rigged up a temporary pipe, but it had to be removed when we craned the column through the roof. Having been into the office to ask the ladies not to use the loos, my mate was quite surprised when he heard a loo flush. When a big Richard landed at his feet, he was straight back into the office, asking who it was that had flushed the loo, with what was now the contents of his pocket. All I could do was laugh, and telling him that 5h1t happens.
@Mr_A_Builders2 жыл бұрын
Hahaha!!! Mate, that's ace!!!
@WingoverVideos2 жыл бұрын
We had a buildover drain issue we needed to resolve. Did all the paperwork with Severn Trent, submitted drain surveys, engineering plans, building control approval on the design. They still said no. They do not budge an inch - so inflexible. Infuriating process.
@jonost242 жыл бұрын
Great job with the pipe👌It's a shame ST couldn't be bothered to come and take a look. Lazy bastards!!
@mdturner37239 ай бұрын
I feel your pain. we had a similar problem with Southern Water. 3 months to get a build over agreement for 800 mm of pipe. if they sent people out rather then emails to a call centre life would be a lot easier for both sides
@crumplezone1 Жыл бұрын
Great work dude
@timcharlton74232 жыл бұрын
Awell done to all the team we had the same problem with them we decided to put rodding eyes to the bottom of all the new soil stacks inside and outside all the soil pipes inside wern box in we made access panels
@delscorey87272 жыл бұрын
Great Job not easy in those conditions...well done ...enjoying the build..thanks
@Mr_A_Builders2 жыл бұрын
Thank you Del.
@garryedwards845110 ай бұрын
I'm no builder, So watching this is fascinating. What a great insight to your work. Exemplary workmanship.
@Mr_A_Builders10 ай бұрын
Thank you, Gary! Hope you're well mate.
@sedgy739 ай бұрын
Had load of issues with severn trent during my build no help at all
@billybulmer73862 жыл бұрын
Another interesting vid guys. So that’s Jamie Oliver as well as Scott Mills off your Christmas card list?😂
@Mr_A_Builders2 жыл бұрын
Haha! They were never on it mate!!! Thank you once again, Billy.
@EcoMan-te4vu2 жыл бұрын
Thanks for sharing guys. fwiw a resting bend would have made it easier for Trent Water to approve.
@EcoMan-te4vu2 жыл бұрын
Or a swept bend
@Mr_A_Builders2 жыл бұрын
It was a flat no form them mate!
@mostlydiggers2 жыл бұрын
Nice video, lads.
@Mr_A_Builders2 жыл бұрын
Thank you mate, appreciate that. Hope you're well.
@Wolveslandscaper2 жыл бұрын
Great news mate finally got somewere sometimes u just have to do it and then they understand but carnt wait for next vid to finally c u getting out the ground
@Mr_A_Builders2 жыл бұрын
Haha! Nearly there matey!
@mwkp382 жыл бұрын
Couldn’t you have put in two inspection chambers? Extending the straight line out the building to one, then linked to the second where it would change direction? Direct lines all the time?
@Mr_A_Builders2 жыл бұрын
Hello Martin. No chance I'm afraid. There just wasn't the room to get the angle to get back to existing and only use 30⁰ bends as per the request of Severn Trent. We way that we did it was the only way it could have been done. Have a great new year mate.
@anthonyrich45732 жыл бұрын
A bend in the line not aloud in Somerset
@keithrimmer32 жыл бұрын
You need to use long-radius bends there will be no problem
@anthonyhendley16892 жыл бұрын
Probably someone at a desk at trent Water never been near a drain before
@judyblundell90972 жыл бұрын
I’ll be very interested to see what lintels you use to bridge over the pipes as I have a similar situation
@paulbanks94089 ай бұрын
Prestressed concrete ones 100 x 70 mm
@charlieskehan520 Жыл бұрын
For give me but u could see the existing manhole was in line with the footing before work started, so y wait until u had nearly all the footings in before u talked to Severn water.y wasn't it thought of before commencing any work
@lewisbrand2 жыл бұрын
Any change of direction, and/or change of fall requires an inspection chamber. The only exception being a long radius bend ( through roddable ) close to another inspection chamber large enough to gain access to the bend. There is absolutely no way this installation complies with building regs. Why not just put a sealed and tileable cover on the inspection chamber and leave it inside the extension ? There are plenty of properties I have worked on where there was no other choice. Just because the existing drain layout does not comply with modern regs does not mean you can replace it with new works to a substandard old design.
@johnclements66142 жыл бұрын
I don't understand why they did not put the chamber in where the first hole was. Then the pipe would be straight and a new pipe could be installed without digging under the extension in the future.
@kevinmills52932 жыл бұрын
Lewis sounds like the guy from Severn Trent
@stuartjones22422 жыл бұрын
nice job,
@Mr_A_Builders2 жыл бұрын
Thank you Steve.
@nigelhaines79002 жыл бұрын
SOME times best not to get water authorities involved just do the drainage( job done)its one rule for them another for us!
@mrboyban Жыл бұрын
Great video as always. I'm holding my breath for this one. Have to replace a collapse drainage as part of the extension. Do you know where can I find the BR doc for that? Thanks.
@michaelnaughton13932 жыл бұрын
Days like that you realise you are not a Builder but just there to "manage" the expectations of the Client and and the local authorities. Still got there in the end.
@Mr_A_Builders2 жыл бұрын
That's right, Micheal. There's so much more to it than just building stuff, isn't there.
@curtisthomas89352 жыл бұрын
Good work
@mahmoodzahid84882 жыл бұрын
Well done mate . excellent . Learnt a lot .many thanks . I am replacing the sewerage pipe in my garden .I am just a beginner .want to know how much p gravel across and over the pipes and cani put hard core and compacted over the pipes please for dpc mesh sub base flooring raft foundation trenches .got build over the pipes approval .please guide .much obliged and many thanks
@leeyo5494Ай бұрын
hi when people remove a manhole and fit the new round style inspection chambers, how do they rod them when they get blocked, they dont look wide enough to get the rods down and round into the pipes?
@georgelfc12 жыл бұрын
Did I miss it or have you forgotten to put the photo in that you showed them ? Thanks
@Mr_A_Builders2 жыл бұрын
Hello mate, I may have forgotten to put it in the video, sorry mate!
@georgelfc12 жыл бұрын
No probs 🤣
@jonost242 жыл бұрын
Can you get some support from building control at all, to back up your proposal?
@Mr_A_Builders2 жыл бұрын
Hello Jono, hope you're well mate. Yes, building control was happy from day one but they wouldn't be able to sign it off without Severn Trent's approval.
@thomaselston46802 жыл бұрын
I've never give a quote as well on an give an estimate for the unforeseen make sure you got them to sign rather than quote that makes you liable
@thomaselston46802 жыл бұрын
U got that roof on yet lol
@tdimccullough2 жыл бұрын
I thought they would have been looking for a long radius 45° bend in the main line
@Mr_A_Builders2 жыл бұрын
Hello David, hope you're well. Everything was replaced like for like. Thank you for watching.
@MattRileyCreative10 ай бұрын
@@Mr_A_Buildersnot like for like as the inspection chamber was there for the change in direction 😂, you’ve removed that and then but an additional angle on top which is a second point for blockage, a complete lack of like for like
@ir78689 ай бұрын
Brilliant work. Hard work in narrow space
@Mr_A_Builders9 ай бұрын
Cheers mate!
@lewisyorks74972 жыл бұрын
Don’t you suppress the silica dust from your disc saw?
@Mr_A_Builders2 жыл бұрын
Not on this particular occasion, no. My bad. Soz.
@andrewstevens74532 ай бұрын
Rather than take a chance then ask if the moving of the Inspection Chamber is acceptable, why not demand Severn Trent tell you what is. I had similar problems, they were frustrating at times and my foundations took 3 months before we were able to pour the concrete. We still wait for full approval 😮
@Mr_A_Builders2 ай бұрын
Mate it's a nightmare isn't it! Hope you get it sorted soon. Thank you for watching.
@Stan_55UK10 ай бұрын
Great work and very interesting, but please wear eye and face protection when using a cutter. My son's face was a terrible mess when a disc let go.
@richardcapey-wade81912 жыл бұрын
get a straight coupler ,knock tabs out from inside ,remove seals then you have a great pipe marking tool for life,cheers
@Mr_A_Builders2 жыл бұрын
That's a great tip, richard. Thank you. Have a great day.
@hotchill11 Жыл бұрын
Nightmare those awkward drainage. Its a relief once concrete is in and ready for build
@Mr_A_Builders Жыл бұрын
Ain't that the truth!!!
@hotchill11 Жыл бұрын
@@Mr_A_Builders there's also the nightmares of excavating that what other issues can arise. Had one a few years ago that we were digging for the invisible footings and there wasn't one on existing so we had to drop the whole rear wall to part rebuild with footings to allow for it to carry the majority of the existing floor with steels and new build floor also underpin corners to allow load bearing coming down from steel carrying wall plate of roof. Old was on the piss because of subsidence. We ended up replacing half of the existing floors of the house. We later come back after completion to underpin the front side of the House. Sometimes these jobs are head scratching to price. A garage Conversion is quick turnaround without all the stress 😬 all fun and game though keeps the mind active.
@RickJames92792 жыл бұрын
Should have brought the lateral out of the extension footprint into a tee and built your IC at that point. That would have eliminated the 45 degree bend altogether.
@Mr_A_Builders2 жыл бұрын
Hello Rick, hope you're well. Can you explain that in a bit more detail please? Not too sure what you mean. Cheers mate.
@RickJames92792 жыл бұрын
@@Mr_A_Builders errrmm, I’ll try ! Haha Continue the main lateral right through the original IC to just outside the extension footprint. This then meets your new lateral from the loft conversion SVP. At this tee, construct a new IC… I hope this sounds as simple as it does in my head ! 😂
@RickJames92792 жыл бұрын
Your new IC would be where you excavated first time. Any bends downstream of this would be outside the footprint and readily accessible if needed. The reason the bend is frowned upon is because it will now be under the extension and be an absolute nightmare to repair should it require…
@Mr_A_Builders2 жыл бұрын
Haha! Cheers man! Really appreciate your reply. I know exactly what you're saying now. Unfortunately we just couldn't do that and keep the bends to a maximum of 30⁰ which is what Severn Trent wanted. Which just didn't have the room within the boundaries of the property to get the angle back in. The only way we got away with the 45⁰ is that it was already there. It can be rodded from two different points and jetted.
@RickJames92792 жыл бұрын
@@Mr_A_Builders ahh I must have missed the boy about maximum angle of any bends !
@MattRileyCreative10 ай бұрын
The issue here would have been that the inspection chamber is there because of the 45° turn, can’t have a change of change in direction with out a chamber
@Mr_A_Builders10 ай бұрын
I've got a letter from Severn Trent saying that you can, so who's right? The governing body of the water waste system in this part of the country or some random person wedged into a load of KZbin comments? Thank you for watching though. All the best.
@simonsimon5572 жыл бұрын
I'm in East Sussex, our water company isn't concerned what you do if the pipework is within your own curtilage.
@garethfraser5211 Жыл бұрын
What your method for calculating the fall on pipe?
@itaz6276 Жыл бұрын
I have had the opposite issue- Severn Trent have confirmed they are happy but Acivico (the birmingham council building inspection) are being difficult - no reasoning as to what their issue is despite the water company being happy with the works
@jonost242 жыл бұрын
We've just had our first fix electrics & plumbing done. Plaster boarding almost done. Building control was OK for pre-plastering check. Bloody cold though. The silicon used for the cavity closures just hasn't set in this cold, in fact it it's just a runny mess. Just too cold!! Bromsgrove by the way.👍
@Mr_A_Builders2 жыл бұрын
You use silicone on cavity closers? That's interesting. In what way?
@jonost242 жыл бұрын
@@Mr_A_Builders I didn't, the builder did. I think just to get a good seal on them. It could have been adhesive? Whatever it was, it didn't set. Personally I would have used something like clout nails on the block on the inside, plasterboard over, plaster, job done.
@Mr_A_Builders2 жыл бұрын
Oh ok. I use clout nails but if the builder does it to get a better seal then fair play, I'll look into that technique.
@CrimeVid2 жыл бұрын
You can’t rely on local authorities to do or say anything sensible, I spent a lot of time changing bitumen-fibre pipe that they had insisted in changing the old salt glaze for ! For those that missed the bitumen fibre debacle, the inner layer of bitumen degrades and the cloth under it turns backwards like an old sock, causing some horrible messes !
@philiphurdwell34432 жыл бұрын
I have same with Thames water, they want like for like materials, no plastic onto clay....
@Mr_A_Builders2 жыл бұрын
Hello Philip, is that right! You have to replace clay with clay?
@philiphurdwell34432 жыл бұрын
@@Mr_A_Builders yeah!!!! It's a nightmare sometimes, the reason is that they dont want drain runs with different spices etc which I understand in some situations but should be reviewed on an individual project basis
@markfinnerty50172 жыл бұрын
God bless to you, I can here the local accent wolves here come across this all the time Severn Trent biggest money scam ever ( they don’t know where half there drains are we pay them ( customers) to find out , got own small building firm ,everyone thinks your a millionaire when the reality is we keep on getting hit , all the best for the future
@Mr_A_Builders2 жыл бұрын
Thank you Mark and you are totally right in every way! Take care mate.
@seanmcgrath91672 жыл бұрын
15:15 i just use a off cut of pipe about 50mm wide with a 80mm cut out and snap it onto the pipe
@beegardenservices22312 жыл бұрын
I've watched your past videos, I know your doing everything as much as you can by the book. I admire that. Do your self a favour and listen to me. If the rainwater gutters and gullies are connected to the wastewater drain, rainwater could overwhelm the drain and cause flooding... Wastewater pipes should not be connected to the rainwater system! EVER A down pour could end up in the waste water backing up pipes. Please look into this more with your "Inspector". He should have told you to key the new storm water into the peatrap from the house guttering. Also send an inspection camera down that pipe to see where the soak away is, also then access weather the rain on the m² of the new roof isn't going to overwhelm it. And if it is, dig it up and make it bigger to accommodate the new roof size. I've done enough of extensions, soakaways, replaced waste drainage and landscaping to know to tell you. Just hope I'm not too late.
@housesforsale68922 жыл бұрын
seven trent water are a nightmare to deal with
@freespeech22612 жыл бұрын
Wizzer no glasses, naughty boy : )
@mmchesh2 жыл бұрын
……and dust mask……
@Mr_A_Builders2 жыл бұрын
Yeaaahh, you're both right ...soz....
@josepharnold5419 Жыл бұрын
Good job on a nasty fit had my share of septic tanks drainage fits…….. Nfld. Canada
@johnsaunders65104 ай бұрын
“Covered in poo time”. 😂
@jimmyjohnstone58782 жыл бұрын
Bureaucracy gone mad. Surely they could have asked for a Skype call with you showing them all the pipe layout and have an informed discussion. All well in the end but you could do without the additional hassle.
@Mr_A_Builders2 жыл бұрын
Hello Jimmy, ain't that the truth!!! I asked them a couple of times and it was a flat no.
@clivewilliams36612 жыл бұрын
The information to STW should have included the existing layout and the proposed - there was no need for any site meeting or skype call if the info was properly detailed. The info to STW was no more than what was properly necessary for Building Control and for the builder. It seems that there was a an intent to get away with the minimum.
@Oncewasdonka2 жыл бұрын
Could you not of plugged up the sewer until the work was done,? Thanks for the upload
@dr-mn7ld2 жыл бұрын
Surprised they didn't moan about the bend in the shared sewer without a manhole on the bend. They gave us a bit of grief over a barely 20 degree bend.
@Dr_Fi5hCakE2 жыл бұрын
Sometimes it is better to ask for forgiveness than for permission. Have you seen if they will have another look at it as somebody else might see eye to eye with you if they have more experience or seen a similar job 🤔
@Neverforget1332 жыл бұрын
Not another bodge
@Mr_A_Builders2 жыл бұрын
??? Oh Paul...not again....
@Neverforget1332 жыл бұрын
Yes I thought the same when I see this video form you oh not another mistake 🤣
@m0aze6112 жыл бұрын
What a shame you come up against armchair experts, the final agreement probably comes from a more experienced person. That’s progress for you. 10/10 for tenacity and doing your best. Regards Mike
@Mr_A_Builders2 жыл бұрын
Thank you Mike! Appreciate that mate, thank you.
@S.p.h.2021 Жыл бұрын
7trent told me rain water cannot go to fowl. I had to make soaks
@Mr_A_Builders Жыл бұрын
I feel for you, man.
@stillgame48862 жыл бұрын
Would have drilled a small hole in existing drainage system would have saved that hole filling up will water all the time, if your changing existing piping anyways 👍
@Cityzen1-p1n10 ай бұрын
You sound like Roy Wood!!
@Mr_A_Builders10 ай бұрын
Funny you should say that, Roy Wood and I have a few things in common, one being that we both wish that it could be Christmas every day...
@Cityzen1-p1n10 ай бұрын
@@Mr_A_Builders 🤣🤣🤣......You also say "So to speak" a lot as he does!
@davidsanders28062 жыл бұрын
Didn't think you could put rain water into a main normally a soak away different rules in different areas
@Mr_A_Builders2 жыл бұрын
Hello David. You can put rain into a combined system, providing it is a combined system in the first place that is. A lot of building inspector can get their knickers in a twist over it but fortunately ours didn't.
@davidsanders28062 жыл бұрын
@@Mr_A_Builders yeah some do
@abdulvalimahomed54968 ай бұрын
Hi, I wanted to turn my garage into 1 bed studio, however my garage is at the front of the property, the only man hole I can see is at the back of the property. The next next door neighbour on the left has man hole in his garden. I rang severn trent and they sent me some forms which i really don't understand. Whats my best bet, try and investigate on my own getting sewer maps or just calling in professional, builder doesn't want to touch the drainage system. I'm in Leicester if you know anyone round here.
@mickgascoigne40033 ай бұрын
The last extension I did on my old house I didn’t get seven Trent involved Came to selling the house they asked for the build over agreement didn’t have it paid 70 quid for an indemnity policy job done Now in my new house I will be doing the same no way I’m paying them anything
@kevinmills52932 жыл бұрын
It’s such a lottery dealing with these authorities. It could easily have gone the opposite way.
@Mr_A_Builders2 жыл бұрын
It definitely could have, Kevin. Luckily we got hold of a practical person in the office and it went through! It was definitely squeaky bum time!
@davidquirk809710 ай бұрын
Severn Trent and their "building over or adjacent to" I had to take a load of photos to prove to them that they their sewer map was about a hundred years ( the time when my house was built) out of date. Still good to get the letter saying no problem though. Ultimately we didn't build the brick detached workshop anyway but built a wooden structure elsewhere on the property so it was all for nothing.
@scottmatthews25892 жыл бұрын
Oh blame poor mick for the hole 😂
@Mr_A_Builders2 жыл бұрын
Haha! If it goes well it's thanks to me, but if I make a mistake it's Mick's fault!!! Dems da rules!!!
@scottmatthews25892 жыл бұрын
@@Mr_A_Builders mate standard we all got a mick lol due to family commitments iv had to give the private game up took a multi trade job 8-4 fair play to you doin right by you customers and doin the job properly well mick is anyway lol
@Mr_A_Builders2 жыл бұрын
Haha! That he is! Fair play to you mate, hope it all goes well for you. Where you from?
@scottmatthews25892 жыл бұрын
@@Mr_A_Builders good old sunny Aldridge in Walsall that’s how I clocked ur accent lol 😂
@johnmckay21352 жыл бұрын
Its because the water company's literally read out of CESWI
@Tonymason7622 жыл бұрын
Get a Jamie Oliver’s Cornish pasty next time you’re at Shell, they’re dynamite
@Mr_A_Builders2 жыл бұрын
Dynamite? Is that because they destroy your bank account???
@bricklayersworldwithandy62772 жыл бұрын
At the end of the day this shouldn't be costing you a penny same as the foundation, down to a bad Architect who should have had all the proposed design layout of new drainage runs on a drawing, then any deviation is chargable. Nothing wrong with RW going into an existing combined system rightly or wrongly its allowed. In my area the manhole base must be bedded on concrete not pea shingle.
@Mr_A_Builders2 жыл бұрын
Cheers Andy, it's always good to hear from you, someone who knows both what they are talking about and also what and how to do it when it doesn't translate into the real world. Hope you're well mate, take care.