Home Charging Installation Risks and Advice

  Рет қаралды 164,238

Munro Live

Munro Live

Күн бұрын

Sandy, Dick and JW discuss home charging issues and solutions
If you like the content you're seeing, please consider visiting our website or subscribing to our Patreon group for exclusive content.
PATREON: / munrolive
MUNRO LIVE LINKEDIN: / munro-live
MUNRO MERCH: teespring.com/stores/munro-li...
MUNRO LIVE WEBSITE: munrolive.com/
MUNRO LIVE TWITTER: / live_munro
MUNRO LIVE INSTAGRAM: / munrolive
MUNRO LIVE FACEBOOK: / munroliveteam
MUNROLIVE TIK TOK: / munrolive
MUNRO & ASSOCIATES MAIN WEBSITE: leandesign.com/
Outro:
Music from KZbin Audio Library [Aka YAL]
Music provided by RFM: • Video
#EV #Charging #Installation

Пікірлер: 1 300
@mr-huggy
@mr-huggy Жыл бұрын
Munro should have a look at tearing down some chargers that are used in homes and commercially to see the standards they have.
@adasdasdasdasdasd9678
@adasdasdasdasdasd9678 Жыл бұрын
Safety is paramount. But convenience is nice to have in a home charging setup. for that look at "chargehanger"
@drkastenbrot
@drkastenbrot Жыл бұрын
they are really quite good across the board. thats why you dont really find very cheap ones.
@chargehanger
@chargehanger Жыл бұрын
Europe has solved this proble, mostly. There are specialized EV plugs like the "greenup", and a lot of people use the P17 plugs, which are rated for continuous use. Breakers are rated for continuous use, and legislation often prescribes specific classes of RCD to use.
@drkastenbrot
@drkastenbrot Жыл бұрын
@@chargehanger in germany a professional installation is only done with direct wiring to the fuse box, no plug at all.
@michaelhess4825
@michaelhess4825 Жыл бұрын
These are not in fact chargers, it's a misnomer. All charging happens within the car. These are just cable and adapter interfaces, some with logic for power delivery. They are very simple devices, even the smart ones.
@stevemacdonald9702
@stevemacdonald9702 Жыл бұрын
I am an electrical engineer(retired) who wrked in design of building services. The problem with all of the burned plugs, breakers, and boxes was that the wires used in all of the failures shown was that they all used aluminum wire. This is a known issue with high load applications ( electrical heating is another one) where the load is intermittent. The constant cycling causes the aluminum to flow when hot and then when it cools the connection pressure is reduced. don't use aluminum wire- copper only, and you should not have problems!
@frankrizzo1433
@frankrizzo1433 Жыл бұрын
I agree %100, I'm an A Journeymen in the IBEW with 30 years in the trade and an AAS. the first thing I noticed was the aluminum wire and sub standard Home Depot parts! I own a Tesla Model 3 & Y and I only use HUBBELL products. I'm will to bet these guys have no license or very little experience with anything rated more than 20amps. Most people have no idea about expansion and contraction when it comes to electrical connects. As you know torque requirements to have consequences! " Electrical Work is a Profession, NOT a Hobby" it looks like these guys used the "WIRED FOR FIRE" method of design.
@davidreidenberg9941
@davidreidenberg9941 Жыл бұрын
Hello. I am charging for the last 2 years using the charger that came with my Tesla 2021 model 3. I charge every night in my garage using a standard 115v outlet to 85% SOC typically pulling around 12 amps. This works well for my driving needs. However, my house was built in the early 70’s and has aluminum wiring. Do I have any reason to be concerned? If so should I have an electrician install that special thing ( I don’t remember what it’s called) in the outlet that deals with the issue with aluminum wiring? What about the breaker? Thanks
@The_DuMont_Network
@The_DuMont_Network Жыл бұрын
@@davidreidenberg9941 If you have aluminum wiring in your house, call a REPUTABLE professional electrical contractor to inspect your entire wiring installation. There ARE tabs you put on the end of the aluminum wire to allow proper connection. All compression lugs should be inspected and torqued - all the way from the power wire coming from your power company to the individual outlets. It's gonna be expensive, but you really need to pay attention. I really don't like to be a pessimist, but you have to treat this situation as carefully and attentively as you would the natural gas connections in your home.
@davidreidenberg9941
@davidreidenberg9941 Жыл бұрын
@@The_DuMont_Network thank you so much for your timely response. What about my specific question regarding the way I am charging?
@sleeknub
@sleeknub Жыл бұрын
Who TF uses aluminum conductors for something like this? We always use copper. Weird…
@Radium3D
@Radium3D Жыл бұрын
A couple tips that might help that anyone can do as a EV owner since 2019: 1) If your car charges fully really early overnight, reduce your charging amps with your car / charger settings. For example I can do 32 amps with my home mobile charger, but I have it set to 22 amps because my car finishes charging fully well before I wake up in the morning, no need to charge at max amps. 2) If you use the mobile charger and never unplug it from your socket, it might be a good idea to unplug it and re-plug it every 4-6 weeks just so that it keeps a nice clean contact. My mobile unit has complained about overheating once and after re-inserting it into the socket, the overheating stopped.
@duderino8722
@duderino8722 Жыл бұрын
Great tips, Radium… Thanks! A couple quick questions if you don’t mind: 1). I also use a mobile charger for plugging into my newly installed outdoor 220 outlet. I’m set to charge at 32 amps, but sometimes the charging drops to 16 amps according to my Tesla app. Any idea why? I’ll follow your lead and set to 22 amps and see what happens. 2). What would you recommend to clean the mobile charger prongs and outlet receptacles? Would an electrical contact spray help? I’m a total newbie on this, so thanks in advance for any suggestions! And thank you Sandy!
@tedmoss
@tedmoss Жыл бұрын
You would be better off to get a good contact cleaner, save a call to the fire dept.
@cgamiga
@cgamiga Жыл бұрын
#1 yes. No need to stress your system if no need. #2, NO. The MAIN failure point for the cheap $15 Home Depot outlets (besides non-torqued connections) is frequent RE-plugging, the blades/contacts are not designed for many plug cycles at all (just ONCE for a dryer, left forever), and can loosen. If metal is in contact tightly, it won't get dirty anyway. Hubbell outlets are designed for MUCH better blade contact cycles, and also the wiring lugs/bracket clamps are much better designed as well. Money WELL spent.
@duderino8722
@duderino8722 Жыл бұрын
@@cgamiga great, thanks!
@Radium3D
@Radium3D Жыл бұрын
@@cgamiga difference between a dryer and the EV is the long duration of the full power running between the outlet and the plug. This is why I think the corrosion can occur over time and can cause it to overheat. Also I wouldn’t do it more than 4-6 week intervals. But the higher quality outlets are of course the way to go. I still think those might require occasional unplugging as they too would corrode slightly over time.
@SnowArcs
@SnowArcs Жыл бұрын
What typically happens in these failures is that the plug gets dirty, the connection isn't tight enough, or the conductors get a little bit oxidized. This causes the resistance to go up slightly. An additional 0.1 ohm on a 30A system is 90W of heat in the connection (360W in a 60A system). As the temperature rises the conductivity gets worse (causing more heat) and eventually the whole thing melts down. Plug materials changes can contain the blast but they won't solve the root problem.
@xxwookey
@xxwookey Жыл бұрын
Indeed. To be fair to that junction box it seems to have done a reasonable job of containing the damage for quite some time.
@mikehamm5217
@mikehamm5217 Жыл бұрын
I use die-electric grease on these type outlets to minimize corrosion on the plug connection.
@1djbecker
@1djbecker Жыл бұрын
@@xxwookey That enclosure certainly did its job. It contained the failure that appeared to be caused by improper wire selection and poor assembly. In a perfect world a robust enclosure wouldn't be needed, just something to divert the rain. But the NEC has a second line of protection. I look at that as a success.
@marksherman6769
@marksherman6769 Жыл бұрын
I've been living the 120 V lifestyle so far, have a Tesla home charger, and now I am thinking about getting a second box just for the EV and make sure it's a lot safer than that burnt out one. Thank you for this!!
@teslamac5348
@teslamac5348 Жыл бұрын
This is also a serious problem for 110v mobile chargers that come with the car. After moving to a new home I discovered I could run my Model 3 on a 110v charge. Unfortunately, the outlet convenient to the car was the 5th outlet daisy chained from the breaker. While the mobile charger automatically derates to a 12 amp draw, after almost a year I had a smoke event and found a completely fried outlet in the middle of the outlet chain and outlets on either side having been overheated. Using the end of a chain like that is bad enough, these outlet were installed using the push in connections on the back of many outlets. Any electrician will tell you those suck and to never use them. Every EV owner needs to have an an EV experienced electrician like JW evaluate their charging installation.
@TimBertram
@TimBertram Жыл бұрын
I should be noted that having a thermal camera is a great tool to help find these issues. Some businesses regularly scan electrical panels for hot spots. Hot spots and indicate poor connections, underrated wiring, or breaker issues. Moving forward it might be another important tool to have at home.
@toddmarshall7573
@toddmarshall7573 Жыл бұрын
$400 well spent. Can also find leaks in your insulation.
@IDNHANTU2day
@IDNHANTU2day Жыл бұрын
@@toddmarshall7573 I purchased a FLIR camera that attaches to your phone. I compared it to an actual expensive camera and it was spot on. About $300 on A ma Zo n. I purchased right after I installed my Bryant (Hubble was almost tipple the price and according to Gra inger, it is the same product) 14-50. I often check the temperature from the socket all the way back to the Service box to make sure no surprises have developed.
@rp9674
@rp9674 Жыл бұрын
that reminded me I have a IR thermometer, I should check my charger with it. Not as good, but much much cheaper.
@pablopicaro7649
@pablopicaro7649 Жыл бұрын
Great info , as always, thanks again for your efforts informing us in the cheap seats
@rickmorenojr
@rickmorenojr Жыл бұрын
If I recall correctly, NEC requires that anything that runs continuously over 2-3 hours must be rated for 125% of calculated continuous current. So if you are drawing 60A, you need to rate everything for 75A or greater. Also, many breakers, outlets, cut-off switches, etc. are not rated for high temperatures. You might need to increase wire size to decrease temperature to match breaker and plug ratings. Most cheap NESC 14-50 plug outlets are not rated for continuous current and are only rated 60C. (They're rated for 1 maybe 2 hours at most.) If you are assuming that your 90C conductor can save you money, you're wrong. The lowest rated temperature is deciding factor. The conductor must derated (must increase conductor size) to compensate for the lowest temperature rated device. The heat from the conductor, as well as any poor connections, will heat the associated equipment. And lastly, don't forget about voltage drop. Having an EV circuit ran from a breaker panel located on the other side of a building/house will probably cause a voltage drop, which will also heat up the conductor. Branch circuit should be limited to a maximum of 3% voltage drop. Don't go cheap while wiring you EV receptacle.
@mfrankgilbreath6271
@mfrankgilbreath6271 Жыл бұрын
I installed a big box junk 14-50 outlet and when my son came over with his Tesla, after charging for 4 hours at 40 amps, the outlet was so hot it could burn your hand. Replaced the outlet with a Hubbell and now it get barely warm. Luckily he was only visiting for a few hours, a over night charge could have cause a fire
@roger1818
@roger1818 Жыл бұрын
He mentions the derating at 21:10 and suggests that it go from 125% of the value (80% of the breaker) to 130% (about 77% of breaker). FLO already does this by limiting their EVSEs to 30A instead if 32A on a 40A breaker (which is actually 133% of value or 75% of breaker).
@apostolakisl
@apostolakisl Жыл бұрын
A longer wire of a given gauge has more voltage drop but does not get hotter than a short wire of the same gauge under the same load. The two wires would warm up the same amount when located in the same environment. The same heat into a lot more wire means a lot less temp rise since it has more surface area to dissipate heat. The 3% drop is related to acceptable operating voltage at the target and by itself, can not predict temperature rise. For example, a 3% voltage drop at 240v/40 amps over 6 inches of wire would be flaming hot, but over 150 feet it would be difficult to detect the warming. To know the actual temp rise you would need to know the environment. If the wire were running inside of insulation it would get warmer than if it were running through an empty wall cavity because heat dissipation would be slowed.
@apostolakisl
@apostolakisl Жыл бұрын
@@mfrankgilbreath6271 I installed a Leviton 14-50 and it does not get warm to the touch charging at 40 amps for hours on end. I'll have to put my FLIR on it to see what it looks like sometime. Not sure what brand you had, how old it was, and how many times it had been plugged in/unplugged. They do wear out with repeated in/out.
@mfrankgilbreath6271
@mfrankgilbreath6271 Жыл бұрын
@@apostolakisl I guess you got a good one and the one I got was crap. It wasn’t from excessive plugins. I installed when my Son got a Tesla. Anyway, after getting the Hubbell and seeing the huge difference in quality, I feel better having the Hubbell.
@normangebhardt2092
@normangebhardt2092 Жыл бұрын
Thanks Sandy, JW and Dick for bringing this serious issue out in the open. Please keep us informed as the solutions unfold.
@tedmoss
@tedmoss Жыл бұрын
The solution has already unfolded, you have been warned.
@jonathangourlie9098
@jonathangourlie9098 8 ай бұрын
The solution is simple. Don't use Aluminum wiring. Every failure here has aluminum wiring. I'm honestly surprised they never mentioned that or seemed to notice
@vecamiolo
@vecamiolo Ай бұрын
or improperly sized copper wire.
@ezpoppy55
@ezpoppy55 Жыл бұрын
We had our 75 year old home’s panel replaced, updated, and upgraded just prior to deciding to buy two EVs. I got my Model 3 in March 2021, my wife got her VW ID.4 in July of ‘21. I had our electrician install a Tesla Wall Charger off a sub panel just a foot from the charger. For the VW, it has a new 14-50 outlet off a different sub panel with all new wiring. We also use TOU charging (between midnight and 6 AM), when other electrical appliances are not in heavy use. Except, during the summer, the a/c will run overnight to keep the house cool. For well over a year, no problem with either set up. However, I am now going to have our electrician come out and give the setup he installed a good inspection and have him upgrade anything that he deems necessary. I’ll share this video with him, too. Thanks for the great work on this!
@jameshay884
@jameshay884 Жыл бұрын
Sandy and his friends and compatriots are great teachers. Regulation of the quality and performance of EV charging infrastructure clearly requires government regulation. Because, as Sandy has so aptly put it…, ..” some people don’t like it when their house burns down.” Well said!
@robertbigler7743
@robertbigler7743 Жыл бұрын
Get the government involved????? What makes you think THEY"RE going to make things better? They'll just add to the cost!
@1djbecker
@1djbecker Жыл бұрын
Regulation of electrical infrastructure has existed for a century, and has evolved to be exceptionally safe. Very few changes are needed for what is just another electrical load, comparable to an oven, HVAC, or water heater
@toddmarshall7573
@toddmarshall7573 Жыл бұрын
If Sandy had his way he would have regulations for rigid markings on "all" roads. Kind of naive.
@tedmoss
@tedmoss Жыл бұрын
@@robertbigler7743 The government is already involved and has been for many years, houses used to burn down much more readily, where have you been for the last hundred years?
@Surestick88
@Surestick88 Жыл бұрын
@@robertbigler7743 Yeah, let's leave it to corporations to make sure we're safe. They certainly won't put profits before what's best for their customers.
@lg1355
@lg1355 Жыл бұрын
You have probably saved homes and possibly lives with this video. Thank you, I am about to check my entire charging system.
@toddmarshall7573
@toddmarshall7573 Жыл бұрын
FUD is a beautiful tool.
@tedmoss
@tedmoss Жыл бұрын
It is obvious that people have to learn when new stuff comes out.
@graemejohnson9025
@graemejohnson9025 Жыл бұрын
Ev is a wank.. fire hazard in all homes... like a Huge Hover Board...
@lg1355
@lg1355 Жыл бұрын
@@graemejohnson9025 Eloquently stated. Sounds like you have really done your research. I bet you were the smartest kid on the short bus.
@gregdavis3723
@gregdavis3723 Жыл бұрын
I think the real problem here is people installing charging systems who are incompetent, unknowledgeable or careless. They should understand the difference between continuous and intermittent loads. They should know that a $10 14-50 socket is not going to be up to par, although it also apparent that UL Listing alone is not sufficient for verifying that the parts meet their specs. That said, based on what I've seen in recent years, most of the problems are due to careless or incompetent workmanship. I don't see much point to passing more laws and regulations that will just be ignored. If current laws and regulations were followed properly, these problems wouldn't be occurring.
@NSFWHarold
@NSFWHarold Жыл бұрын
I hope the reverence and respect that folks hold for Sandy Munro translates into this getting traction. Thank you for Sandy for allowing your platform to be used to get this out there.
@paulcummings55
@paulcummings55 Жыл бұрын
What a very good show and warning! We are probably a year or so away from getting our first EV- but this show may be the most important one to consider in that process of an EV purchase. Well done, and tell Mr. Shaw 'thank you,' for me!
@obfuscator
@obfuscator Жыл бұрын
Lack of certification for intended use is beyond frustrating, but sadly nothing unexpected. You guys are doing a great job with this PSA, hopefully it gets further though. Thanks.
@SolveFixBuild
@SolveFixBuild Жыл бұрын
I’ve dealt with our local building code inspector and I wouldn’t trust him to think too hard.
@leoncargile3410
@leoncargile3410 Жыл бұрын
Can’t overstate the value of the information you gentlemen gave! We live in a world where we look for fast answers. We hear, “Move fast & break things, we can fix it later”. I’m not thinking that about setting my garage or house on fire. The Cheap, Fast, Good triangle demands Brains. You folks brought some thinking to the table. Well Done!
@by9917
@by9917 Жыл бұрын
I've been home charging since 2014. I've installed 5 or more EVSEs. Never any problem. Recently I went to a direct wired EVSE to support the 11.2kw the MME can draw. My house has 2 x 200amp main service panels. I have no doubt there are lots of people, even licensed people, that don't do a job correctly, but I have not seen or even heard of any problem with home EV charging in my area. Not sure about that box, but it looks like an A/C disconnect, which may only be rated for 30amp.
@Resist4
@Resist4 Жыл бұрын
There have been no USA house fires related to home EV charging. This video makes it seem like it's a bigger issue than it really is. Maybe if hard wired wall charging units weren't so expensive then people wouldn't use a mobile connector for full time charging. But that still isn't a problem if you keep the mobile connector plugged in all the time and buy another one to keep in the car. Even 120 volt house outlets have a limited life when things are frequently plugged in and out of them.
@seantiz
@seantiz Жыл бұрын
I’ve set my charging to a lower amperage because my gut told me the higher temps were not a great idea. I’ve got no experience with this level of expertise, but I feel safer charging at lower amps and late at night when there is less chance of an oven or other high amperage units running at the same time.
@janverschuren3446
@janverschuren3446 Жыл бұрын
That is called COMMON SENSE. When you have the whole night? Just charge at half power. BUT when you need to drive a lot and need full power? Again use common sense and design for continuous load. Breaker spacing is a good one that I took from this video. Leave a space below and above empty for air circulation. Again, common sense.
@logicalreason51
@logicalreason51 Жыл бұрын
Yes common (wire) sense is key. No plug in chargers should be used. All should be directly wired. I recommend stepping up the wire gauge as well. I used #4 wire. Stepped it up for heat load, especially here in Phoenix. Wire temps in the attics here are in the 170s with no current in the wire. After watching this I am questioning my 60 amp “ regular” breaker for the EV charger. Might have to redo my entire panel. My house was built in the 80s.
@Resist4
@Resist4 Жыл бұрын
@@logicalreason51 Plug in charging is perfectly acceptable, especially if you leave it plugged in all the time. House 120 volt outlets go bad when plugged in and out frequently too.
@andrewt9204
@andrewt9204 Жыл бұрын
This is good practice. No need to charge max power if it gets done well before needed. I've noticed on my car, charging at max amps causes the cooling fan to kick on more often. So at the very least, you're wasting more electricity from heat losses.
@doomsday9973
@doomsday9973 Жыл бұрын
@@logicalreason51this is nonsense the vast majority of EVSEs are plug in and work fine. Stop being alarmist
@bertwright1790
@bertwright1790 Жыл бұрын
For those of us that can’t get the box, circuit breaker and plug changed out will dropping the max amps the EV will pull to 20-25 amps rather then 40+ amps relieve the problem enough to be safe. I use RV park 50 amp plugs a lot at many different parks. Going overnight the time isn’t so much an issue, but at times they are the only power source available.
@gregridgway9136
@gregridgway9136 Жыл бұрын
Thank you guys so much for this. I too experienced a similar event. An upgraded connector will help, but I learned that Europe is forcing the use of wire ferrules to keep the strands of wire in place at the connection points. It fixed my problems completely. I also used a 100A splice point to avoid any heat buildup. Simply clamping the wire and mashing doesn't work.
@b4804514
@b4804514 Жыл бұрын
Well done Sandy. I just called my electrician to educate him and get him to change out the breaker and plug. JW's recommendations are very necessary given the loads of these weak points and fire potential.
@tracle8334
@tracle8334 Жыл бұрын
What’s the recommended nema connector brand ?
@rcjbvermilion
@rcjbvermilion Жыл бұрын
@@tracle8334 I think the one mentioned in the video was Hubbell.
@toddmarshall7573
@toddmarshall7573 Жыл бұрын
I'll bet your electrician got a chuckle out of that.
@trex2092
@trex2092 Жыл бұрын
@@beachcrow Thank you. Hubbellreceptacle 3P4W 50A 125 $139.99 is cheap. What's your life worth? I ask people that balk at the price on a wiring component.
@hilariohernandez340
@hilariohernandez340 Жыл бұрын
You can't educate an electrician, we know everything. He probably decided to just get more easy money
@babyUFO.
@babyUFO. Жыл бұрын
GUYS... The NEMA 14-50 interface you were holding is rated for a *40 Amp* charging rate ... which is the maximum allowed by the NEC for charging using a 50 Amp circuit. Yeah, and the Tesla wall connector charger is 48 amp. See the issue now? the 1450 connector isn't designed to handle 48 amps for more than a few seconds
@Darkdragon917
@Darkdragon917 Жыл бұрын
Thank you all for the great information. I am currently in the process of upgrading our whole home/ garage electrical system to better accommodate 2 EVs. I hadn’t even considered the bus bar thermal management from the breaker to breaker perspective, and will also be bypassing a wall plug for the 2nd charger in favor or direct wiring!
@tomschuessler7723
@tomschuessler7723 Жыл бұрын
It's a good idea to check for high joints by feeling cables, connectors and breakers and/or use IR Temp sensor periodically. connections can go bad over time plus under high load. I had my Tesla wall connector direct wired to a dedicated sub-panel with other receptacles including a 40-50 for other EV's to use four years ago and set the car to charge at a max. 25A to80% 90% of the time. Adding a line monitor to limit current when driers, air conditioning and other loads are all on at the same time is a good idea, too. Thanks for bringing up the issue. I used to install high current xray machines 480VAC 3phase in an earlier life and were always cognoscente of proper connections and grounding.
@rp9674
@rp9674 Жыл бұрын
Great points, my electrician recommended we don't run the dryer & charge at the same time, seems like a good idea and worth the minor inconvenience
@scottluckman8765
@scottluckman8765 Жыл бұрын
You definitely need to adhere to the 80% rule as a minimum. I do have the 14-50 dryer plug as my receptacle, but it is on a 30amp circuit breaker and the charger is set to 20amp load. Most wall chargers allow you to set the charge rate, just be wise and not select the highest one you can! 😉
@johnsonfamilyvideos1876
@johnsonfamilyvideos1876 Жыл бұрын
Having a 50 amp rated plug connected to a 30 amp breaker is not exactly error-proof (or poke-yoke as Sandy would say). Consider switching to a fully capable 50 amp circuit ( including wiring) or make sure the plug is clearly and durably labeled so nobody accidentally burns down the structure!
@markplott4820
@markplott4820 Жыл бұрын
480v 3-Phase is so much better.
@Thatdavemarsh
@Thatdavemarsh Жыл бұрын
@@johnsonfamilyvideos1876 you never want (apart from being illegal) to install a 50 amp plug to a 30 amp breaker. That will allow someone to connect a 50 amp load to a severely under rated circuit.
@unitrader403
@unitrader403 Жыл бұрын
@@Thatdavemarsh You can plug it in, but the Breaker will trip before anything bad happens, so i see no practical issue with that. Unless your breakers are much diffrent than the ones we have here in Germany. Here the rule is Circuit Rating (Wiring and Connectors) >= Breaker Rating >= Circuit Load. The other way around would be really bad though (30 Amp Wiring and Socked with a 50 Amp Breaker)
@patrickkenny2077
@patrickkenny2077 Жыл бұрын
@@unitrader403 for US codes, the wire back to the breaker should be rated for the full 50A. A smaller breaker isn't a problem as long as the wire won't ever be overloaded, but you cannot rely on the breaker to limit current.
@vvattup
@vvattup Жыл бұрын
Good discussion. Long time coming. Too many Tesla owners pay $70,000+ for car but cheap out on appropriate home charging equipment. Four years ago I purchased the Tesla connector and had it installed by a Tesla certified master electrician. And yeah, a separate line was installed to a dedicated junction box with a blade cut off. Cost $1400. No issues.
@danneil8778
@danneil8778 Жыл бұрын
Thanks guys. Public understanding of EVSE is crucial.
@markplott4820
@markplott4820 Жыл бұрын
they Dont even Teach EVSE or BEV Tech in Middile or High School.
@danneil8778
@danneil8778 Жыл бұрын
@@markplott4820 Be a good time to start.
@vecamiolo
@vecamiolo Ай бұрын
So much better to understand the continuous load capacity of the wire feed and circuit breaker.
@jmbpr1v8
@jmbpr1v8 Жыл бұрын
Thanks for this safety related video. One thing I noticed on the failed components was that they appeared to have aluminum wiring. For heavy, extended loads I would definitely prefer maximum gauge copper wiring even though it costs quite a bit more.
@mrhickman53
@mrhickman53 Жыл бұрын
I use a mobile charger but, since I have overnight to charge I limit the charge current to 25 amperes on a 50-amp circuit. The continuous rating for a 50-ampere circuit is 40-amperes. Since resistive losses are proportional to the square of the current, this reduces those losses by ~60%. Similarly, a 30-amp dryer circuit is rated for 24 amperes continuous, so charging at 19 amperes provide a proportionate reduction in heating losses on that circuit. Even if I were to install directly-wired charger (Electric Vehicle Supply Equipment, or EVSE) I would follow a similar practice as the main panel breaker for the circuit is also subject to the heat stress. It has been too many years (decades?) since I've studied NEC, UL, ETL or other requirements for these types of interconnection components so I cannot comment on the expected lifetime of a properly applied (torqued) component operated at its continuous rating. I only know that operating comfortably away from the continuous rating of any component will greatly extend its lifetime. Since I like my equipment to have good lifetime I am generally conservative in how I use it. I am a little disappointed that, other than selecting "bakelite" vs. other materials for temperature withstand, no other guidance is provided for selecting a more robust version of a NEMA 14-50 receptacle, for example. Both styles would have passed UL, ETL CSA-US or other certification for 50-amp intermittent, 40-amp continuous rating. This may be what the commentators are getting to when advocating for a tougher set of EVSE standards. A follow-up demonstration of an "acceptable" NEMA 14-50 receptacle and a lower cost "unacceptable" NEMA 14-50 receptacle, properly installed and applied at the 40-amp continuous rating. I would be interested in any difference in temperature rise between the two devices. A second comparison with a terminal improperly torqued on each would reveal a difference in safety margins between the two components, particularly the temperature at which the housing starts degrading. This would better inform the decision to install the more expensive component.
@ddextera
@ddextera Жыл бұрын
Exactly! Please do a follow up video for consumers highlighting what's safest. I have a Leaf that charges every night by mobile charger to an ordinary wall outlet that I never unplug from the wall. Model Y arriving and installing dedicated Tesla charger for her. Will the electrician know if I need a separate dedicated breaker box for that? Am I correct now concluding that I do from this video? My neighbor is building a new home from scratch where he'll be charging his big Volvo SUV, what would be the best practices there?
@kqschwarz
@kqschwarz Жыл бұрын
This is one of Sandy's most useful and important videos, and that is really saying something since his company's videos are almost always extraordinarily useful and important. The importance of the fact that EVSEs have duty cycles that last for hours cannot be overstated. Dryers, water heaters, electric ranges, all turn on and off. It is only the EVSE that comes on and stays on at high current for hours. My installation is a 60-amp circuit to a Tesla EVSE that draws 48 amps to max out my car's 11 kWh on-board charger. My EVSE is wired directly using copper cabling. It is clear from this video that electrical plugs, circuit breakers and wiring needs to be labeled "EV certified". Before seeing this video I was under the mistaken impression that any 60-amp plug or circuit breaker could be used for 100% duty cycle applications, which is clearly not the case. I was lucky to find a professional electrician who specializes in EVSE installations to do the job. That was 4-years ago when there were not as many electric cars on the road. I live in a small town outside of Rochester, NY, so I was "super" lucky to find an expert in my small town area. Hiring an expert was money well spent. I suggest anyone looking to install an EVSE in their home investigate electrical contractors in their area that have expertise in this area. Ask them if they install EVSE specific equipment and if they use copper cabling. Their answers could determine if your house is safe or not. Thank you Sandy Monro for an extraordinarily helpful video.
@jmcalpin1
@jmcalpin1 Жыл бұрын
Karl, I Iive in Rochester. Who did the electrical work for you?
@jonathangourlie9098
@jonathangourlie9098 8 ай бұрын
This isn't true. Any NEMA 14-50 outlet can handle a Tesla mobile charger. You are right about needing copper cable though. Look closely at the video and you will see that EVERY failure shown is using Aluminum cable. The root cause is the aluminum cabling. This video should be about 30 seconds long and titled "This is what happens when you charge your EV on aluminum wires"
@pierrelambert446
@pierrelambert446 Жыл бұрын
Great video. I have a permanent installation for my EV at 48 amps. I limited my charging speed to 28 amps as give plenty of time for my car to charge overnight. I am happy I have done this after watching your video. We should always charge at the slowest speed that convenient for the model of car we have and the usage we are making.
@BillyBob-fd5ht
@BillyBob-fd5ht Жыл бұрын
Your battery will thank you and your wallet, Toyota will only have slow charge on their system. fast charging = early death of your battery plus the charge is so quick it drains a lot quicker too. fake charging
@BnORailFan
@BnORailFan Жыл бұрын
This video came out at the right time for me. I hired an electrician 4 years ago to install a NEMA 14/50 port in my garage and have been using the Tesla mobile charger since with no problems. However a few months ago I bought the Tesla wall connector since I'm now charging two EVs (one at a time) and needed a longer cable. I was tempted to install it my self but will now hire an electrician and mention the problems covered in this video. THANKS!
@Van_Liberty
@Van_Liberty Жыл бұрын
I just installed a 30 amp single pole RV outlet in my garage sub panel for my lithium battery class B motor home. In my research, I learned about wire gauge and what it needs to be for distance runs of circuits. I really do applaud Sandy and his guests at MUNRO for this video. This sure is some serious stuff and it looks like the standards agencies are a bit late to the party. Hopefully, some with the ability to facilitate changes will see this video and start making this stuff right...
@tedmoss
@tedmoss Жыл бұрын
The standards agency's have been up to date for many years, people just don't pay attention to them. I just checked, Tesla tells people what the standards say and others likely do also, just listen. You can only recommend not force people.
@Van_Liberty
@Van_Liberty Жыл бұрын
@@tedmoss Will you please cite the standards resource documentation e.g. web link so we here can take a look? I'd like to read up on the subject mater and thanks...
@wngimageanddesign9546
@wngimageanddesign9546 Жыл бұрын
As an EE, I immediately see a red flag and "Uh Oh" in that cut-off junction box. Aluminum (Aluminium) wiring! It's still coded and allowed in the USA as a cost-cutting measure. But I would avoid it due to potential overheating and fires. It is very specific as to what type of aluminum compatible interfaces you can use, and specific steps to safeguard against galvanic corrosion. Many electricians, and homebuilders don't hire the certified and knowledgeable 'apprentices' to be aware of the physics behind this. Many homes have old aluminum wiring mixed with cheap replacement switches and outlets meant for copper wiring.
@gregorybower9498
@gregorybower9498 Жыл бұрын
Unlike you, I'm a layperson. But, any mention of aluminum wiring is just frightful.
@tesla_tap
@tesla_tap Жыл бұрын
Looks like both melted situations use aluminum wire. While using cheap aluminum wire can be made to work, but it's far tricker, and every component attached must be rated for alumium. Really better to use copper with proper components, such as industrual rated outlets, not consumer grade.
@stevehearst5865
@stevehearst5865 Жыл бұрын
I spent $1,000 to install the Tesla Wall Connector by an Electrician (did not include the Tesla unit) Don’t go cheap. It always amazes me how many KZbinrs are promoting DIY for only a few hundred dollars! Stop the insanity! Good job Sandy and Team! Giving the whole story!
@joelronish1625
@joelronish1625 Жыл бұрын
As an architect, this is so important. Thank you Sandy
@health101DOTorg
@health101DOTorg Жыл бұрын
A good recommendation: If you torque down a connector onto copper wire, go back on it ten minutes later... you'll find you can tighten it more to get to that previous torque setting. Why? Copper is a soft metal; it will compress over those ten minutes to where you can re-tighten the connector. And try it a third time... you'll be surprised. Heat occurs from a high resistance connection. Keep connections tight, and you reduce the risk of over-heating from high load circuits like EV chargers. But since time is money, electricians don't like to spend the time to do this procedure.
@reilleysinventions4155
@reilleysinventions4155 Жыл бұрын
It looks to me like the failed sockets were wired with aluminum wire. It is even softer than copper and has worse oxidation problems.
@paulaxford6754
@paulaxford6754 Жыл бұрын
I'm glad someone is paying attention. The clamp has very low elasticity and can't be expected to hold the ductile copper or aluminium wire under a compressive force for a long period. It really needs a better clamp design.
@billjohnson3344
@billjohnson3344 Жыл бұрын
Agree the common issue comes down to proper torquing and wire type. Also the connection points themselves (plug contacts, disconnect contacts). Most EVSE installation instructions state to use copper wire - this doesn't look to be the case in these failures. Not sure what the rating was for that burned "EV disconnect" box - looked more like an air conditioner disconnect, which wouldn't be the right device for the job even if some inspector wrongly approved it. Agree though that the NEMA outlets shown were low quality.
@BillyBob-fd5ht
@BillyBob-fd5ht Жыл бұрын
You are so correct, just like tires. I have had plug flickering from the wire in the circuit box coming loose, it was tight at first. Retorting is a very smart
@rp9674
@rp9674 Жыл бұрын
Great tip, thanks!
@eugeniustheodidactus8890
@eugeniustheodidactus8890 Жыл бұрын
*Passed this along to my electrician.* Many thanks! I will have my electrician install a separate EVSE breaker and panel with voltage management. Glad I went with the decicated TESLA wall charger with no junction boxes used. Not a fan of using 60A just because "i can". Best to give wide berth to the minimum code requirements.
@beachcrow
@beachcrow Жыл бұрын
Sounds like overkill if you are already set up with the Tesla Wall Charger. You can just reduce the maximum charging to 40amps instead of 48amps if you want to reduce the load.
@SDSBBQs
@SDSBBQs Жыл бұрын
This is right on time. I planned on installing my home charger this weekend.
@atguru
@atguru Жыл бұрын
Thanks Sandy! I recently a NEMA 14-50 installed for.a Chargepoint Home Flex - by certified electrician. However, I never knew any of this information that you and your team shared... Now I'm going back and reviewing this insulation, to see if all possible safety precautions have been to observed! Many thanks!
@williamthesling1201
@williamthesling1201 Жыл бұрын
I've seen this kind of thing before. It seems very likely that what's happening is that the series resistance is rising at the contact interface(s). It's not much of a change, but when pushing 32 or 48 amps through a contact (of some sort), even a quarter ohm of resistance across the contact results in 256W of power generated at the contact interface (when pulling 32amps). It is a lot of power being dissipated in a small volume resulting in very high temperatures! The trick seems to be to make sure you have good contacts! In the back of receptacle, proper torque is important here (as you've discussed). A few other steps that might help. 1. After installing a receptacle and properly torqueing down the screws, after a day or two of service, retorque them again. Sometimes the heating "relaxes" the metal a bit resulting in a poor contact. Retorqueing the screws can remedy this. 2. It might be difficult for folks to do this, but monitoring the voltage "seen" at the car can help identify a problem. In the above example of a quarter ohm increase in the interface resistance would result in an 8 volt drop in the voltage as seen at the car. This can be a little difficult to determine since the line voltage itself can vary a bit, but 8 Volts is large enough to observe (generally). What would really be nice is two voltage measurements. One at the service panel, and one as seen at the car. This difference between these two voltages, divided by the current, is a measure of the total resistance between the panel and the car. If this changes (rises) over time, it indicates a problem. it would be time to check your wiring/connections. Maybe retorque some screw, maybe reseat the plug into the receptacle? Maybe replace a receptacle? Hope this helps!
@ericensley2427
@ericensley2427 Жыл бұрын
The car should be able to do this for you. When pulling zero amps it will see the static voltage and then when it pulls full amps it will see the sag voltage. Would be good to program that check into the car.
@Marki555
@Marki555 Жыл бұрын
@@ericensley2427 At least Tesla is doing it. If the voltage drop is not too big and is slow, it just slows the charging (for example to just 6A/230V from max. 13A/230V). If the voltage drop is sudden, it will stop the charging with poor grid quality error.
@tesla_tap
@tesla_tap Жыл бұрын
A secondary problem is the vehicle and connection design. For example, Tesla has thermal cutout in i's connector in case the outlet was not wired properly and overheats. In addition, Tesla monitors the voltage and if the voltage sags (due to bad wiring or installation), it shuts off. I suspect other manufaturers don't offer these safety systems yet.
@RevRonC
@RevRonC Жыл бұрын
Since I am looking to have the wiring done for my CyberTruck in the coming year, this is a very timely and critical topic for me. I will find the best professional electrician I can in my area, and will go over the specs of the installation very carefully. It seems obvious from the discussion that the current code is not relevant to the need here. Thanks for keeping us safe with this video!
@tedmoss
@tedmoss Жыл бұрын
The current code is relevant (if you have one) and has been for many years, it is just not implemented because of ignorance.
@normt430
@normt430 Жыл бұрын
Just like putting the cart before the horse...
@phebrian
@phebrian Жыл бұрын
Great information thanks for bringing it to our attention! 🙏🏼
@dogownrpenna
@dogownrpenna Жыл бұрын
Thank you for telling us. I had no idea, and I'm guessing most of the general public knew about the nature of this. We all think a dryer outlet is simply a dryer outlet. Never knew to factor in duty cycle or the other things mentioned. Great public service making this video!
@stickersadd20hp
@stickersadd20hp Жыл бұрын
Lowering the amps will help with excessive heat. It's a partial solution at $0 cost.
@boy531
@boy531 Жыл бұрын
Ya I hear all these folks on forums and KZbin hyping up their tesla wall connectors pumping out 48 amps getting their car charged up in 0.75 hours. My wall Connector is on a 60 amp circuit running #4AWG wire and it still gets my a garage up a few degrees when I charge. I lowered it to 32 amps just for my own peace of mind
@MTNRanger
@MTNRanger Жыл бұрын
Industrial grade outlets and proper torquing probably will help most situations. Of course, properly gauged wiring and breakers is assumed. There's nothing wrong with moblie connectors - I use two for five years now with no issues.
@davidbroda1
@davidbroda1 Жыл бұрын
Interesting, I had similar problems: 1. my breaker was making noises (was extremely hot) and it tripped every time my charger went over 4A. 2nd problem I experienced - was my plug melted, as showed in the video
@cougarlike
@cougarlike Жыл бұрын
Thank you for getting this info out. The brand new world of EV charging with high current/constant loads needs attention so avertable disasters don't happen, Thank you gentlemen!
@W4rH4wkXX
@W4rH4wkXX Жыл бұрын
very interesting.... i just set my 240v charge sessions to 16 amps.... just to keep the heat down. more than enough for an entire overnight charging.
@Resist4
@Resist4 Жыл бұрын
Then why not just use a 120 volt outlet?
@wgibson768
@wgibson768 Жыл бұрын
I'm a master electrician and most of the issues like this are caused by the installer not tightening the the lugs or alternatively stripping the threads. Look for where the hot spot begins. Finally, he mentions torque, not many people use torque wrenches! We are not going to get people to change out panels to bolt in breakers. Do they really think that someone has never had a dryer or range running for an entire Saturday or Thanksgiving????
@Thatdavemarsh
@Thatdavemarsh Жыл бұрын
You are 100% on point here. I have 25 years of maintenance, industrial ops, and engineering. Everything you said is 100% what is going on. Add cheap parts to the lowest bidder labour skill level, and this is what you get.
@cgamiga
@cgamiga Жыл бұрын
I have an electricity monitor, and even full-use for oven and dryer, they are 50% load cycle at best. I can see the square-wave pattern of the cycles on&off. EV charging, is a solid constant load 100% of the time. and yes, torque (and RE-torquing) is critical. Going to re-check mine now...
@Alex-je6od
@Alex-je6od Жыл бұрын
The problem is these 50A plugs are designed for stoves, and other "non-continuous loads" The electrical code is well aware of the issue of "continuous loads". Where we could get away undersizing wiring slightly for a range or dryer, you can't get away with undersizing when the load runs for 4+ hours. Thats why the electric code calls out for conductors being sized at 80% for continuous loads. (circuit can handle 50A, but your car charges at 40A) Electricians aren't paying attention to "continuous" vs "non-continuous" load classifications because there aren't many "continuous load" devices in the home... thus they follow non-continuous practices, creating fire hazards. That 50A plug is probably designed to deal with real-world (non-continuous) loads of 40A with 50A being "peak". Now you take 80% of 40A and get a maximum "continuous load" of 32A. 32A is pretty standard for older generations of EV's.. however as vehicles start pushing up towards the limits of 50A, we start seeing these failures. tldr; hard wire your EVSE if it does over 32A real world. Make sure you wiring it sized for 50A.
@cgamiga
@cgamiga Жыл бұрын
I don't think any NEMA 14-50 plug-connected EVSEs go over 32A?... they shouldn't, if there are some that go to 40A, they really should be required to hard-wire for that! good point!
@doomsday9973
@doomsday9973 Жыл бұрын
@@cgamigathey can go up to 40amps
@Mike-pn3eg
@Mike-pn3eg Жыл бұрын
Well I’m scared now, living in a house of seven people my Washer and dryer run 24 seven. Also everything in my house with electrical equipment made 45 years ago in America for better or worse. This is a great video! Your doing Gods work Sandy!
@joebleed
@joebleed Жыл бұрын
you still might be ok. the heating element in the dryer doesn't run the whole time, it cycles on and off. It may be enough to help. but wouldn't hurt checking.
@wildweav
@wildweav Жыл бұрын
45 years ago, the plug might be bakelite and it can handle the heat. I would get an electrician with some experience to look at it.
@patrickhorner1406
@patrickhorner1406 Жыл бұрын
@@wildweav Jesus christ is this video section just filled with electricians looking for work? How many people have electricians come in to check a circuit that has been working for 45 years? You guys are insane
@nycameleon
@nycameleon Жыл бұрын
My brother in law is a commercial Electrician, and he did a nice job with my charger install :-)
@leerjet18
@leerjet18 Жыл бұрын
So was JW, but when the equipment fails thats not on the electrician. Look for a hubbel outlet made with bakelite not plastic.
@ruftime
@ruftime Жыл бұрын
Great points! A typical 240v dryer pulls 10-30 amps…..but usually with duty-cycle and only 60-90 minutes run time.
@tedmoss
@tedmoss Жыл бұрын
Run time of dryer is not the entire time it is on, it cycles on and off during that period just like an oven, that's why the breaker and wiring and switches and plugs and sockets have time to cool.
@pdavis2207
@pdavis2207 Жыл бұрын
In my house we run the dryer all day once a week to keep the laundry pile under control. The AC runs constantly in the summer and the stove runs several hours each week. The introduction of outlets and a duty cycle is somewhat alarming to me. Seems outlets should either be rated for 100% duty or be clearly marked and rated.
@whatcouldgowrong2231
@whatcouldgowrong2231 Жыл бұрын
Yep. Very welcome discussion! When I charge I open the door to the 100 amp sub panel and put a fan in front of it. You can watch the amps drop and volts go up.
@sydfrissell
@sydfrissell 7 ай бұрын
Absolutely! If an small AC unit was used while the EV is charging, it would be a safety feature. Also, bigger conductors and breakers than needed/rated would be another safety feature, wouldn't you think? Just plain very hot temperatures can be hazardous when charging. charging a little every night rather then charging fully every night is better. Charge only when necessary to match the daily driving needs one has.
@pnketia
@pnketia Жыл бұрын
Wow! This was really eye opening! I thought I could just tell my electrician to install a plug for my wall charger and that was it, but now I need to rethink the whole installation. Thank you.
@Resist4
@Resist4 Жыл бұрын
You don't have to rethink anything, this video is making it seem like a bigger thing than it is.
@lienct
@lienct Жыл бұрын
Here is some advice- Check to see if your breaker/plug/wire is warm after a long full power charge. Slightly warm = OK, Hot = Bad
@kevinmatthews2620
@kevinmatthews2620 Жыл бұрын
excellent on point video Sandy, here in the uk the max home car chargers as far as i am aware are 22kw unless you have a 3 phase install, also a lot of chargers have seperate dedicated earths, all as far as i am aware have to be fitted with a fast cut off fuse, home chargers here in the uk are tested to the max before they can even going on sale, the uk is not generally a user of slow granny chargers(slow) plugged into the mains unlike the usa and plug into the dryer sockets,but then for us its 240v ac single phase is the norm, although newer houses are being built capable of future upgrading to a 3 phase incoming supply, the stickers on my incoming electrical supply is 400v 100 amp, then fused down to 240v 100 amp max load for my house to my fuse box, our ev chargers are also equipped with rcd trips as well, different countries different electrical standards
@puppet-head
@puppet-head Жыл бұрын
22kw is 3 phase, normal chargers are 7kw.
@m.gardner6173
@m.gardner6173 Жыл бұрын
This level of concern and information is why I follow Munro
@detroitgarage9430
@detroitgarage9430 Жыл бұрын
Wow, thank you so much for this heads up.:) I've recently bought a Model Y and am using a NEMA 6-50 extension plug for charging. I'm going out as we speak and checking my outlet and sub-panel.:) Thanks again.:)
@jesses0
@jesses0 Жыл бұрын
This is great info. I would love to see official ratings and code updates around this. In the mean time it would be great if someone put together a parts list of "better choices" (even if not perfect) for people who are looking at this sort of work in the near future. What do I ask my electrocution for or how do I interview an electrician to make sure they are on top of this?
@tedmoss
@tedmoss Жыл бұрын
They already exist, please don't get electrocuted. Show him this video.
@Kangenpower7
@Kangenpower7 Жыл бұрын
Don't allow them to use aluminum wiring for your home!
@rp9674
@rp9674 Жыл бұрын
It's a good idea to get a ul-listed charger, not just ul-listed parts. At the very least it gives you a good argument against your insurance, in the unlikely event of a problem. Pretty sure no one would use aluminum wiring now, it doesn't meet any code.
@ZoraK1717
@ZoraK1717 Жыл бұрын
Another thing to note with the NEMA 14-50 receptacle is they are not rated for thousands of mate/un-mate cycles. If you are using a mobil charger and are constantly unplugging it and taking it with you the contacts on the 14-50 will wear and this could potentially start a fire.
@cgamiga
@cgamiga Жыл бұрын
Hence use industrial outlets. If you unplug that many times,... should get a second charge unit, leave main one plugged in.
@tedmoss
@tedmoss Жыл бұрын
Any socket will become loose over time, if you check it regularly, it would work but people don't do this. You have to take it apart and tighten the connections, I also use contact cleaner. Checks for voltage drop and thermal imaging might be beyond most people, but are easy to do and make it much safer. I check my house and wiring every so often and tighten connections that need it. I used to have a house with aluminum wiring.
@_PatrickO
@_PatrickO Жыл бұрын
@@tedmoss The clamps on the Hubbell are likely designed not to loosen like a crappy screw terminal that relies on crushing the cable to stay tight.
@Resist4
@Resist4 Жыл бұрын
And that's why you should have two mobile connectors. One to stay in the car and the other to stay plugged in.
@poweronee.1124
@poweronee.1124 Жыл бұрын
First thank you for the video and the information and thank you the making and taking the time to put it out there. I am a master electrician in New York City and only this morning as I unplugged my electric car I realized that the prongs were hot and started looking for a new receptacle to replace that one because I know it's at the end of it life. Not everyone is aware of this sign and I'm happy to see that it is coming to light
@jamesdubben3687
@jamesdubben3687 Жыл бұрын
Very important topic. Thank you for using your channel to bring it to light.
@jackwhiteside5094
@jackwhiteside5094 Жыл бұрын
Was that Aluminum Wiring and did this event begin at an Aluminum / Copper junction point?
@morrisg
@morrisg Жыл бұрын
Can you say "Hardwire your charger installation"? Make sure your charger brand uses screw down clamps on the wires, not levers. USE COPPER WIRES as they don't oxidize like aluminum does. If you MUST use a socket - plug arrangement, then buy an industrial socket e.g. Hubbell - Kellems. And if you have the time overnight to complete charging at a lower amp level (say 32A instead of 48A) then charge at the slower rate. The life you save may be your own.
@jimmurphy5355
@jimmurphy5355 Жыл бұрын
The big issue is the contacts in the housing. The cheapest NEMA 14 50 sockets have much less robust contacts.
@ElliottNest39
@ElliottNest39 Жыл бұрын
You have been successful in getting my attention. Extremely valuable information and much appreciated.
@toddmarshall7573
@toddmarshall7573 Жыл бұрын
26:00 Use a heat imaging camera. It will show you dramatically where you need to pay special attention to points of heat generation. And it's almost always right at the connections...not in the wires themselves.
@chrissladek8282
@chrissladek8282 Жыл бұрын
I think the first thing to consider is how many KW of power are you typically going to need to put into your car per charge cycle. If you don’t need to charge at 32A enter a lower current in the charge app that will give you an acceptable charge time. This will also cut down on your line loss heating up wires and circuit breakers. I am using a NEMA 6-20. for charging my model Y. I noticed a little heating on the short run of 12 AWG wire and on the 20A breaker, so I increased the wire to 10 AWG primarily to cut down on line loss (had some 105C 10 AWG). I usually charge from 40-50% up to 85% two times a week it is usually an 8+ hour charge time which is fine for my normal use. It also looked to me like all the failures you had were aluminum wiring. Was antioxidant used on the connections? I think the best bet is to use copper whenever possible.
@gregoryhuckabay8137
@gregoryhuckabay8137 Жыл бұрын
Oxidation of the aluminum wiring in both of the examples they had on the table is a very credible failure mode that I'm surprised they didn't touch on or investigate.
@jimanderson4444
@jimanderson4444 Жыл бұрын
You have correctly named the problem,, funny , never heard a mention of alum, really looked as such with the typical heavy braid. The alum rated jb have stainless connectors. Alum doesn't deal with heat good. Hence the connector and yes torque it . Best is stay with copper , dedicated, # 10. .
@richh650
@richh650 Жыл бұрын
One of the most important and informative videos I have ever seen on the new EV technology gentlemen!!! This needs to be investigated MUCH FURTHER by the "Electrical Industry" as we move toward EV charging infrastructure both on the road and especially at home and in apartment/condo complexes!
@forrestcarlson1742
@forrestcarlson1742 Жыл бұрын
Great topic! Thanks for making more people aware!
@DK-pr9ny
@DK-pr9ny 9 ай бұрын
How does it help us when you bleep out the names of the inferior products so we can’t avoid them?
@lestermarshall6501
@lestermarshall6501 Жыл бұрын
Thanks Sandy and friends. Great job of warning the public about this problem. You might want to explain duty cycle for people who don't know what that is. Again, great job.
@Pipe-Layer
@Pipe-Layer Жыл бұрын
Great info ! Thank you all for this video. It is very eye opening. 🔥
@franksmith9497
@franksmith9497 Жыл бұрын
Thank you, thank you, thank you for well informed information on what to be aware of when I decide to have a charger installed in my garage for my Tesla Y car.
@richardfahrney7139
@richardfahrney7139 Жыл бұрын
Great information. Can we get JW's recommendations in document format so I can pass that on to electricians quoting a job for an installation to follow. Thank you.
@reilleysinventions4155
@reilleysinventions4155 Жыл бұрын
Are these connections using aluminum wire? Makes a big difference.
@daves1646
@daves1646 Жыл бұрын
Thank you for the edu. Using the Mfr EVSE, that was me. Using an existing circuit (120v), that was me. New, full-memory respect for the hazards. That’s me now. Again, thank you to Munro LIVE!!
@eddiebrogna7678
@eddiebrogna7678 Жыл бұрын
Great information thank you all for taking the time to share this information 👍🙏😊
@davidg426
@davidg426 Жыл бұрын
This is a great start. It exposes one of the barriers to adoption. You need to be able to charge at home, for most cases. Complex installations cost money, can additional amps be increased into the service, choosing the right installer and more. Lots of things to test for Sandy and crew. Come to my town home as a case study of a cluster fk. Get me hooked up and film it! BTW, several close friends had significant fires at home. I'm totally aware of fires! Great vid Sandy. Thanks.
@norrisharrington3332
@norrisharrington3332 Жыл бұрын
UL listing (Underwriters Laboratory) is the place to go for the testing these products. Insurance companies should be involved also.
@Resist4
@Resist4 Жыл бұрын
This video is making it more of something than it is. Underwriters would already know about this if it were a problem.
@egntwm
@egntwm Жыл бұрын
I have a hardwire install on a 60amp breaker with a ChargePoint Home Flex. That 60 amp breaker you guys showed is the same in my panel that feeds the charger. What options shall we turn to, to make sure it's thermally safe?
@KrustyKlown
@KrustyKlown Жыл бұрын
Amazon Reviews of Leviton outlet are full of photos/comments of Melted / burned outlets used for EV Charging. The Hubbell outlet reviews on Amazon are also full of Leviton burnt up outlets.
@Chris21709
@Chris21709 Жыл бұрын
I typically charge my Model Y to 80% and then plug in when the charge drops to 60%, so I charge frequently (easy to do) and only charge at 16 amps. The circuit to my hard-wired Tesla EVSE has a 30 amp breaker and the cable will support up to 40 amps, so not highly stressed. Why wait a week to charge just because there is enough charge in the car to go that long? Charge more frequently at lower rate.
@georgepelton5645
@georgepelton5645 Жыл бұрын
I agree. I charge nightly to 80%. That way I am ready for any unexpected trip needs. I charge at only 16 Amps, and only occasionally use the full 32 Amps that is available [80% of 40 A breaker for continuous loads].
@Trimaran12
@Trimaran12 Жыл бұрын
I alway dial back the amps to around 10 or 12 amps. . I have a 40 amp breaker and can charge at up to 32 Amps but would only do that for the last few hours before a trip. Charge every day at low amps is my safety tip.
@ardo111
@ardo111 Жыл бұрын
13:40 I have this box outside my house. There's sort of a "key" for the user and if you plug it in right side up, we'll call that "A", it is connected. If you unplug the "key" or put it back into the box upside down in orientation "B", it is OFF. Plugging in using the "A" orientation (upright), it is easy to fail to seat the key fully. You really have to PUSH it in to fully engage the contacts.Not-fully-engaged contacts could be the problem, not the electrician as Sandy suggested.
@wtmayhew
@wtmayhew Жыл бұрын
For my personal use, I use the GM-supplied EVSE cord, plus I bought a second identical cord from an auction web site to keep in the car. The GM EVSE cord is programmed for 12 amps max and the Bolt will draw either 8 or 12 amps at the owner’s discretion. The GM cord is very high quality and very moisture resistant, made for GM by Clipper Creek. The wall plug also has an integral temperature sensor to cut off charging if it gets too hot. I use the cord at home with a pigtail to allow 240 volt operation. I never remove the plugs from their sockets and actually have the input cord attached to the wall with nylon clips to discourage anyone from trying to take the cord and put it in the car, but there is enough slack to unplug in an emergency. For my situation, 12 amps at 240 volts is plenty. The car is always topped up to 80% and ready to go in the morning. As I mentioned elsewhere, if you use high quality components, you won’t get burned (literally!). You get what you pay for. Be suspicious or cheap Chinese EVSE equipment from eBay and Amazon.
@medawson01
@medawson01 Жыл бұрын
This topic is so timely. I just got my Tesla 3 RWD last month, and I am getting estimates from electricians to install a 240V outlet in my garage. I am using the mobile charger in a 120V outlet. The third electrician I interviewed was trained by Tesla, and he pointed out two major violations when I had solar panels installed on my house. The installer tied the wiring into the CommEd box instead of adding a breaker to my electrical panel. The panel is in a closet, and he told me I should not store clothing in it (I have lived here for 40 years; he was the first person give me this information.) Thank you, Sandy, for this valuable information. Now I plan to order a Tesla charger rather than a 240V outlet. In addition, I learned the outlets in the garage are not grounded, so I stopped using them immediately. I use SuperChargers now.
@Crunch_dGH
@Crunch_dGH Жыл бұрын
In CA we all have 3-prong grounded outlets, by default. Not so on the East Coast? Or maybe just only in older homes that weren’t required to be retrofitted? Please advise.
@LabradorNewf
@LabradorNewf Жыл бұрын
My friend had the official Tesla charger installed for his Model Y. The breaker in his panel failed a few weeks after install. Maybe a lot of the problem with the dryer plugs is lack of proper GFCI protection. I would use a breaker with integrated GFCI, hard-wired with a local fused disconnect like many do for heat pump installs. That and avoid EVSEs not endorsed by auto manufacturers like a lot of the stuff on Amazon.
@toddmarshall7573
@toddmarshall7573 Жыл бұрын
@@LabradorNewf GFCI is not to protect the equipment. It's to protect you. When it see's more current going out than coming back it shuts down in milliseconds. It assumes that extra current might be finding its way to ground through a human. That's why they're in bathrooms.
@trex2092
@trex2092 Жыл бұрын
@@LabradorNewf GFCI circuits are also prone to tripping just because they "feel like it". A friend ruined a lot of meat in a freezer because he had plugged the freezer into a GFCI outlet in his garage. Copy machines will also trip them, I work at a high school and have seen this happen. When I built my house I had a dedicated circuit/outlet just for my freezer.
@LabradorNewf
@LabradorNewf Жыл бұрын
@@trex2092 yes but outdoor circuits or ones near water should be protected. Many hardwired EVSEs do have internal ground fault protection but I'm not sure about portable ones using a NEMA plug
@jamesacre6186
@jamesacre6186 Жыл бұрын
Could it also be caused by the aluminum wire? Need to have a good clamp force and to add de-oxidizer to the wire ends before installing. Best to use copper wire at about 3 times the cost (or more).
@peteradair3032
@peteradair3032 Жыл бұрын
Hit the nail on the head here.
@dtl
@dtl Жыл бұрын
Excellent topic! Thank you Sandy.
@allanreager3306
@allanreager3306 Жыл бұрын
These seem like they're mainly for 14-50 or 6-50 outlets. I have a 14-30 dryer outlet at my house will continuous use having the 14--30 tesla adapter melt it or should I get a 6-20 adapter for it to pull less power?
@WSDFirm
@WSDFirm Жыл бұрын
Thanks for sharing! This is huge! Now people will listen!!!
@gerrys6265
@gerrys6265 5 ай бұрын
I wish the listen part of your hope becomes a reality, but sadly we live in a very strange world where the policy makers reign supreme and the knowledge folks never get to talk to them.If the electrician makes one small mistake however inconsequential he is potentially subject to severe penalization, loses his license etc. but as long as he follows the faulty rules he is exempt from criticism and no one is held accountable....not a good recipe for change.
@FutureSystem738
@FutureSystem738 Жыл бұрын
Great topic. Here in Australia we have double the voltage compared to many American houses, so typically half the current. HOWEVER when installing my Tesla wall charger I made sure EVERYTHING was over size and even so I still use less than max charge current unless absolutely necessary. ie: I very rarely use the full rate of charge, just don’t need to, and also occasionally check everything visually, check terminal tightness and condition, and even check temperatures with a thermal camera after the charger has been on for some time. You can’t be too careful. It’s very wise to be conservative.
@Lex-dy7sm
@Lex-dy7sm Жыл бұрын
Thank you Sandy and Team! Very relevant and important topic for all EV owners.
@judycampbell4582
@judycampbell4582 Жыл бұрын
Thanks guys for the heads up ! Much appreciated. 👍🏻
Ohme Home Pro EV charge Point Installation
18:31
Mark The Sparky Allison
Рет қаралды 52 М.
БАБУШКИН КОМПОТ В СОЛО
00:23
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 16 МЛН
Clown takes blame for missing candy 🍬🤣 #shorts
00:49
Yoeslan
Рет қаралды 43 МЛН
Mom's Unique Approach to Teaching Kids Hygiene #shorts
00:16
Fabiosa Stories
Рет қаралды 33 МЛН
How To Safely Charge Your Electric Vehicle
26:54
State Of Charge
Рет қаралды 66 М.
How To Install a 240 Volt Outlet | Electric Car Charging
48:44
Everyday Home Repairs
Рет қаралды 2,6 МЛН
EV Home Charger Teardowns E1: Tesla Wall Connector
16:48
Munro Live
Рет қаралды 98 М.
The Truth about EV Battery Life and Charging Best Practice ! | 4K
23:46
How Many Amps Do You Need For Home EV Charging?
26:08
State Of Charge
Рет қаралды 426 М.
Giga Castings with Sandy | Evolution of Tesla Bodies In White
17:54
Dangerous Disconnect: Tesla Home Charging Problem Analyzed And Corrected
26:55
NEVER Do This While Charging | EV Basics
7:40
EV Pulse
Рет қаралды 46 М.
3 Mistakes I Made Installing a NEMA 14-50 Outlet
9:53
Josh Charles
Рет қаралды 343 М.
Моя Жена Босс!
0:40
Petya English
Рет қаралды 9 МЛН
Waka Waka 😁 #funnyshorts #rianashow
0:14
RianaShow
Рет қаралды 26 МЛН