Navien NCB 240 Technical Support is Awesome

  Рет қаралды 77,076

Chuck Barron

Chuck Barron

Күн бұрын

Пікірлер: 154
@peterhawth
@peterhawth Жыл бұрын
Great video! Question for you…Would u know why my heater won’t turn on? There’s no display on circuit board when turned on. Is there a reset button somewhere? Model NR240
@ChuckBarron
@ChuckBarron Жыл бұрын
Breaker on?
@scottreuse1487
@scottreuse1487 6 жыл бұрын
I went to the Navien school last March. I definitely recommend taking it. I noticed the mixed metals, possibly causing electrolysis and water restriction due to corrosion in the galvanized fittings. Also the flow screens should be inspected and cleaned. The condensation connection should not have metal due to acidic condensation. I don’t mean to judge you personally. Nice job. Thanks for sharing. I dig your style.
@ChuckBarron
@ChuckBarron 6 жыл бұрын
No problem I appreciate the good advice. this was my first i put in I think. One of my guys did it. but as you know its all on me to get er right. Learning every day! Plumb on plumber.
@caru3257
@caru3257 6 жыл бұрын
What metal? Do you need plastic?
@billthompson9482
@billthompson9482 3 жыл бұрын
@@caru3257 Copper or brass and Pex, NO iron or steel. This unit should have a magnetic filter.
@tonysignorino1690
@tonysignorino1690 10 ай бұрын
I had a Navien NCB-240/130H Installed last in 2022 and am doing a descaling flush and as the sump pump, as it is pumping vinegar, is cycling the pump slows down after its been running for about 5 minutes. I did have a lot of brown iron in the that came through. can you tell me why this may be occurring?
@dennyvetter8196
@dennyvetter8196 2 жыл бұрын
I installed a Navien 240 A in northern Indiana 18 months ago. I've been very happy with the unit, we have a three bed room house that never rans out of hot water. House has three shower and at times all being used simultaneously. I've done one with vinegar flushing with minimal descaling. Fortunately for us our water supply is very clean and no major issues with mineral deposit. For us the unit has been great. I would not purchase an instant whole house water heater if I had poor water quality (Heavy minerals). or an old galvanize incoming cold water piping system. All tankless water heaters need clean water to operate efficiently and have long term durability.
@kevinw1554
@kevinw1554 Ай бұрын
I have a Navien NCB240/130 Combi boiler that is 3 years old installed by previous owners of the dwelling. I am not a plumber (master electrician though) and have an issue that doesn’t show up as any error code at all. I have the boiler set to not preheat the DHW. But intermittently the recirculating pump seems to continue running for long periods and even powering down the unit won’t turn off the pump. Only the main switch or unplugging will stop it. Then at times the pump starts and stops several times. All this with no request for SH or DHW. Any thoughts would be much appreciated! Kevin
@ChuckBarron
@ChuckBarron Ай бұрын
really gotta be in front of it for sure. Tech support is great. Give them a call. they deal every day with their gear as you know.
@kevinw1554
@kevinw1554 Ай бұрын
@ unfortunately tech support won’t talk to a non dealer/tech homeowner, I already tried. I’m in Ontario Canada so maybe it’s different here.
@hercorock123
@hercorock123 5 жыл бұрын
And I always use a filter on the inlet and cold water feed to prevent stuff clogging exchangers. And a neutralizer on drain and yes it’s very tight
@ChuckBarron
@ChuckBarron 5 жыл бұрын
I do notice filters on some vids I have seen on KZbin. I know rinnai comes with a neutralizer and I have installed them. i will look into that.....thanks J
@ItsCarlnotCarla
@ItsCarlnotCarla 2 жыл бұрын
Where is your seatbelt ?
@BoxcarJerry
@BoxcarJerry 6 жыл бұрын
Chuck is this a heating system ? I never saw a small boiler like that .
@todddunn945
@todddunn945 6 жыл бұрын
It is a combi-boiler. Heat and on-demand hot water.
@ChuckBarron
@ChuckBarron 6 жыл бұрын
yes.....thanks for helping me out Todd Currie..see plumbers helping plumbers.....good stuff
@heslind
@heslind 4 жыл бұрын
Do you recommend these combis? Looking to update my old boiler soon
@richardmarchant9313
@richardmarchant9313 5 жыл бұрын
With old systems with galvanised pipework full of corrosion with boilers like this will always cause you problems ! You need a magnetic filter , power flush the system & fit a water conditioner on the cold water supply to help with scale build up. Combi boilers are great if you install them properly , old systems will always pose issues . Plumbers in the USA need to realise they're not old cast iron units that will cope with any system . So it's all about learning new technology & fitting new components to stop corrosion entering the unit. In the uk we have commissioning procedures & if they aren't met the warranty will be voided & put the onus back on the installer to fit it properly. Manufacturers should show that in the instructions . Good to see your embracing it all chuck 👍👍
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Thanks Rich, I need to get to their classes for sure.
@georgefolgers8731
@georgefolgers8731 5 жыл бұрын
From talking with other plumbers these are common parts that go on 240's combi units , circuit boards and pumps, wonder if they fixed that with their new series unit.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
I hope so. I do like these units alot.
@duanedhillon8908
@duanedhillon8908 6 жыл бұрын
Thanks Chuck ,Im installing a 240A mannana , but just for domestic hot water, perfect timing on this video thanks and plumb on dude
@ChuckBarron
@ChuckBarron 6 жыл бұрын
Ya I have to bone up on some service classes. So much work but so little time. GET ER DONE!
@hottuna076
@hottuna076 6 жыл бұрын
Only problem you have galvanized pipe and copper pipe tied in together that will give you a problem in a few years. Inside clogging restricting the flow or corrosion that will cause sediment inside the unit let alone the pipe leaking.
@ChuckBarron
@ChuckBarron 6 жыл бұрын
yes for sure. Not sure why galv was used. Im no fan for sure.
@EricGP617
@EricGP617 4 жыл бұрын
Everything in Massachusetts for water supply pipe is either threaded brass or cooper depending on what year your house was built but all new construction houses use cooper.
@BeulahRWalker
@BeulahRWalker 5 жыл бұрын
Love The Service Call Live
@ChuckBarron
@ChuckBarron 5 жыл бұрын
I love plumbing....ha
@hercorock123
@hercorock123 5 жыл бұрын
I always put a prv on feed into boiler into to fast fill loops with shot offs
@ChuckBarron
@ChuckBarron 5 жыл бұрын
pvr? not sure what it stands for.
@cheddahman3826
@cheddahman3826 5 жыл бұрын
Pressure reducing valve
@ChuckBarron
@ChuckBarron 5 жыл бұрын
man i have to get my abbreviations down....roger that. good point plumbers.
@kenkatie
@kenkatie 5 жыл бұрын
These units have a built in pressure reducer, you just need a back flow preventer on the boiler feed.
@patricksimone1238
@patricksimone1238 6 жыл бұрын
A chuck,I built a 8,000 sqft home with those units 4 years ago,my plumber has been back at 1 a year since them,nice units but very temperamental
@ChuckBarron
@ChuckBarron 6 жыл бұрын
yes for sure. like babies they seem to need some TLC. I have em in my shop. she holding fast as this point. we shall see.
@sigfridovelasquez5675
@sigfridovelasquez5675 5 жыл бұрын
I have an issue with my navien 240 combi, the code im getting is E.001 . does anyone know a possible solution?
@Seanr4285
@Seanr4285 5 жыл бұрын
Sigfrido Velasquez I'm literally fighting this same issue right now. Replaced 3 way switch without any luck so far.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
your best bet is to call navien tech support. Its l
@ChuckBarron
@ChuckBarron 5 жыл бұрын
best to call navien tech support.
@sigfridovelasquez5675
@sigfridovelasquez5675 5 жыл бұрын
@@ChuckBarron thanks
@Seanr4285
@Seanr4285 5 жыл бұрын
Not being a licensed technician they won't do much. I'll keep plugging away at it
@pedrolantigua2720
@pedrolantigua2720 4 жыл бұрын
Me puede decir cuales son los terminales del termostato
@ChuckBarron
@ChuckBarron 4 жыл бұрын
gotta check translations stand by
@nelsonc4451
@nelsonc4451 4 жыл бұрын
How are you going to show us how to install it if we can't see what you are doing
@ChuckBarron
@ChuckBarron 3 жыл бұрын
the good the bad and the ugly.
@TheDavidarlen
@TheDavidarlen 6 жыл бұрын
Thanks Chuck for taking me on a trouble call on a tankless water heater through your video very informative, I really like your videos thanks David
@ChuckBarron
@ChuckBarron 6 жыл бұрын
My Man....thank you!
@grinerpolevault
@grinerpolevault 3 жыл бұрын
Looks like your business card should read "Plumber/Electrician/Computer Hardware Tech". It's a bold new world. So what is your overall experience with the reliability of the Navien Tankless Water Heaters? Do you have to replace a lot of components? More than other brands? What brand would you put in your house ? :)
@ChuckBarron
@ChuckBarron 3 жыл бұрын
I have navien all day long. great company
@rlaframboise1981
@rlaframboise1981 5 жыл бұрын
Can't the power head and impeller just be changed?
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Navien supplied new replacement pump. I would do the same.
@rlaframboise1981
@rlaframboise1981 5 жыл бұрын
@@ChuckBarron its nice to see another tradesmen in his element!
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Thanks Ryan, where you out of?
@rlaframboise1981
@rlaframboise1981 5 жыл бұрын
@@ChuckBarron northbay Ontario Canada
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Canada In Da House!!
@larrygoodell66
@larrygoodell66 6 жыл бұрын
Thanks! My NCB 240 is not heating brick floors/copper tubing in sand (yes it's old) adequately at 150 degrees. How much can I up the radiant temp safely? Notice the setting you show is abt 164.
@ChuckBarron
@ChuckBarron 6 жыл бұрын
I would call tech support...they are very helpful. They will walk you right through it. 800-519-8794
@fdryer5116
@fdryer5116 6 жыл бұрын
After a year of use and becoming as informed as much as possible about my Navien NCB 240-E combi boiler, the factory installed settings for my three zone hydronic system and domestic water temperatures are 180F (max for heating) and 120F for heating domestic water. NYC
@Solderwire
@Solderwire 5 жыл бұрын
Good video, just about to install my first navien tuesday, americans certainly do the install different than us brits, Think the one i'm buying has a grundfos pump for the british maket, rock solid pumps as a rule, difficult to tell but that one looks like a wilo pump re-badged for the navien.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
awesome. thank you.
@spartus56996
@spartus56996 6 жыл бұрын
Too small and tight, any idea why the pump failed
@ChuckBarron
@ChuckBarron 6 жыл бұрын
No idea why pump failed. she purring like a kitting now. we shall see.
@brendanfisher2528
@brendanfisher2528 6 жыл бұрын
im from the uk.. and would always recommend you and cb2 go on these manufacturers courses! they help so much with understanding diagnosing boilers even with just a multimeter.. also to here if a pump is running get a long screwdriver put the metal tip onto the center of the pump and your ear on the handle of the screwdriver and you will be able to hear if it is running... you can also unscrew the flat head on the face of the pump and see it spinning, if it is spinning you can try stop it with a flat head screwdriver, if it stops easy then the pump is weak and needs changing... but you can also diagnose if the pump is weak or dead with a multi meter on ohms reading which they will teach you on the courses ps.. why dint you just change the pump head rather than the full lot? happy new year.. brendan (plumber/gas engineer) uk
@ChuckBarron
@ChuckBarron 6 жыл бұрын
yes...for surely needed.
@pineychristian
@pineychristian 5 жыл бұрын
You can also check pumps with an amp draw with multi meter. Some pumps we work on like ECM variable speed pumps are difficult to hear when unit is firing..
@jeffcoolhd
@jeffcoolhd 6 жыл бұрын
CB-1 you knocked that job out the park peace brother
@ChuckBarron
@ChuckBarron 6 жыл бұрын
I was saved by tech support...
@tinkmomw984
@tinkmomw984 6 жыл бұрын
Hi Chuck, what's the part number of that pump?
@ChuckBarron
@ChuckBarron 6 жыл бұрын
Have no clue....gotta check your model heater for its parts. Tech support gave me the correct #
@anthonys.5653
@anthonys.5653 6 жыл бұрын
Chuck, this issue you had with this boiler is one of the many reasons "why" I refuse to install any tankless or wall hung boiler. I went to a tankless class about 12 years ago, and I almost got thrown out of the class cause of the hard questions I was asking the salesman. The rest of the Plumber's in the room were high 5ing each other cause of the money they were going to make on these installs, and here I was asking technical questions where the salesman started to repeat sales talking points. I get calls all the time from people in my area who have problems with their tankless, and the original installer won't come back to service it. You're a better man than me Chuck..I want nothing to do with these things.
@larsonhomeinspection9932
@larsonhomeinspection9932 6 жыл бұрын
Anthony S. Tankless technology had advanced a lot in 12 years. They are much more efficient and dependable. This is also a boiler and the boiler pump is what went bad.
@anthonys.5653
@anthonys.5653 6 жыл бұрын
Larson, I like the concept of that technology, but in my honest opinion the drawbacks still out weigh the positives. Too many factors (quality,installation,reliability,circuitry,customer error, etc) make these products a living nightmare for any tradesman. Most all of these manufactures recommend a water softener to go a long with the installation of these units. The sticker shock alone, scares my customers away going down the tankless road, knowing that it's recommend to have a water softener. We have some hard water in my area of Pennsylvania, and 1 particular area, would lime up one of these units within a year an a half. I understand fully well that these units can be flushed, but that's where the customer error comes into play, cause you and I both know they forget, or don't want to spend the money. On a traditional boiler, those coils should be cleaned...and the customer's neglect it them as well. Then next thing ya know, we get that phone call "I have no hot water, or my hot water pressure is extremely low", and now it turns into mess. Another problem is, its the dead of winter, and you need a part for one of these wall hung boilers, and the supply house who sold you that unit, has no parts in stock. Sure we can over night parts, but you and I both know customer's don't want to hear that. Plus...the major problem I have with these supply houses are...they will sell you one of these units, but won't have any repair parts in stock. I blame us tradesman for that, cause we don't put enough pressure on them to keep their houses stocked with repair parts for anything they sell. Larson, tankless is just not for me or my company, and I have no problem losing those jobs to my competition.
@larsonhomeinspection9932
@larsonhomeinspection9932 6 жыл бұрын
I hear ya. Definitely more complicated and harder to fix. Cast iron natural draft boilers last forever! I understand the mixing valves go out frequently too.
@anthonys.5653
@anthonys.5653 6 жыл бұрын
My best friend is also a Master Plumber, he ripped his tankless water heater out after 6 months, he couldn't stand it no more. Now granted, that was about 15 years ago so...the units today like you said, are probably better today.
@ChuckBarron
@ChuckBarron 6 жыл бұрын
Im still battling.....but its a lull right now....no service needed. thank god. Im about to relocate my own in my shop...this could be trouble.....lol
@Teonkennedy
@Teonkennedy 5 жыл бұрын
Hey chuck, have you seen huge fuel savings after installing these combi boilers?
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Definite savings.
@annetteg336
@annetteg336 4 жыл бұрын
How long did it take the tec support to tell you what you already knew? I hate to have to pay for the time a plumber while on the phone with them.
@ChuckBarron
@ChuckBarron 4 жыл бұрын
Its like your MVP talking to the head coach. Best play gonna be called. Its worth your calling the right play for sure.
@nelsonbrooks
@nelsonbrooks 6 жыл бұрын
So... no seatbelts req’d in... New Hampshire? Dey sent me dis pump... Chicago? No, our tech, appears to be somewhere in the vicinity of Moorestown N.J. Navien’s 2-day seminar is highly recommended.
@ChuckBarron
@ChuckBarron 6 жыл бұрын
a must.....fo sho! thanks nelson..Its close also. have you been to it? i hear its good.
@issacrobertson
@issacrobertson 5 жыл бұрын
@@ChuckBarron hey chuck, its very informative. they have a hands on room with running units. they also give you a service kit for the unit of your choice included in the class price. and you can buy additional units from them for a lot less than retail.
@hercorock123
@hercorock123 5 жыл бұрын
You should wire in your low water cut off in unit.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
I actually did. Im not sure why my guy did not do it. good eye plumber
@pedrolantigua2720
@pedrolantigua2720 4 жыл бұрын
Estoy confundido con los terminales
@ChuckBarron
@ChuckBarron 4 жыл бұрын
gotta check translations stand by
@robertwoodworth9463
@robertwoodworth9463 5 жыл бұрын
I’m on my 2nd Noritz tankless heater since 2006 . 1st one lasted 8yrs , copper heat exchanger started leaking all over the place, no recirculating pump. 2nd one there latest and greatest-recirculating pump started leaking after I flushed it out (every 6 months) unit is 4 yrs old. Pump is under warranty, not labor. Plumber ordered new pump, put it in , it leaked all over the place, called Noritz back, they didn’t send the gasket set with it. He couldn’t hardly get his hands in there to work on it , they sell Navien but they look almost as bad to work on. I used water softener, scale watcher and flushed them both out every 6 months. Looks like the pumps go out all the time. It’s hard telling what the labor is going to cost on this one, I’ve got at least $3,700 in both so far, money saver, I don’t think so! Never again. These things are a nightmare!
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Sorry to hear and I agree....its like working on a rocket.
@inspectr1949
@inspectr1949 5 жыл бұрын
Great video, have contemplating installing a Navien Combi unit in a home I just bough, don't know if Rinnai is any better but after 4 crazy high priced estimates and researching on line I'll just continue to pay the utility bills for this total electric home for piece of mind.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Thanks...the one thing i hate paying are utility bills. I am trying to use low energy fixtures in my place. between the gas, electric and the cable bill its another monster waist of money. I do understand your thought to.
@eddyvideostar
@eddyvideostar 5 жыл бұрын
@@ChuckBarron To Chuck Barron: If the cable bills are heating you up the wrong way, then, tell the CEO's it's your way or the highway.
@rivera9185
@rivera9185 5 жыл бұрын
great job
@ChuckBarron
@ChuckBarron 5 жыл бұрын
a process for sure....
@johnwray3344
@johnwray3344 6 жыл бұрын
That’s some space age heat & hot water handling on the Nuvian unit. You need a special suit for that⚡️
@ChuckBarron
@ChuckBarron 6 жыл бұрын
the sell a silver suit you can wear while installing. I was thinking of wearing it to sup! SUP LORD lol
@mohawkmike142
@mohawkmike142 4 жыл бұрын
get that copper out of the condensate drain. That rots in no time. PVC only. AND..isn't it nice to have space shuttle technology to make some space heat and take a bath?
@ChuckBarron
@ChuckBarron 4 жыл бұрын
Moo, I learned the hard way. It has been replaced. Life lesson.
@henrybucki7813
@henrybucki7813 4 жыл бұрын
many different o rings and clips you better take notice when changing
@ChuckBarron
@ChuckBarron 4 жыл бұрын
serious lego job here. No parts left out or we got a no no.
@deysanimations1949
@deysanimations1949 6 жыл бұрын
trick for all you out there if you are a landlord with more than one unit....dont put this saver condensing water because you will end up paying a lot of money on repairs and labor ..good for the plumbers but not for the landlordS ...I put 3 gas boilers a good ones for each unit in my bulding . and 3 ao smith PROLINE good water heaters regular venting connected to the wall in the basemant or chinney.. I dont like the power venting water heaters because you need an outlet for the vent to work ALL THE TIME and you will end up consuming more electricity...get regular venting. you just pay for the gas to heat up the water heater and get a gas pilot . not electric pilot starter..best advice I can give you as my personal experience from many coworkers in this field..and just do the maintenance every year or 2 .(you can do it yourself.your items will last at least 15 to 20 years for the boilers and 10 to 15 years for the water heaters..youll be safe a lot of parts in case if you need them in winter or summer ..and separate the units so the paying will come on the tenant bill , they will be happy because they will have hot water from the water heaters and the boiler will be just for winter time .and they will have the thermostat in their units and they can use it whenever they wanted never put a boiler to heat up the water gas or oil your tenant will see the diference on their bill.and move out ..get the good ones that I suggest above so the tenant will not get affect it. now if you have a single house.that you will be only paying I will put a brand gas new boiler for the heat only for winter time and water tank or a water heater.energy efficient. if you keep thinking this condensing boilers will save you money . you are wrong. and that's it folks ..
@ChuckBarron
@ChuckBarron 6 жыл бұрын
you can debate your point for sure with regular flu and the electric to run heaters. Me personally I happy with the situations I have used combi boilers. I am not married to them so I am willing to check em out for my customers sake and even my sake next time I need an upgrade. I really appreciate the space they save too. Thanks for input lolli poppy. where you from plumber?
@jenlemay5981
@jenlemay5981 6 жыл бұрын
Same problem I had. My plumber guy charged me $1000 to replace! Are these guys serious? That's half the price of a new unit!
@ChuckBarron
@ChuckBarron 6 жыл бұрын
Not sure what you had done. warranty Job?
@jenlemay5981
@jenlemay5981 6 жыл бұрын
same symptom, fire up, over heat, then shut down. Guy came out said pump was bad and billed me $1000 said it wasn't warranteed part. Middle of winter and no heat for 2 days I just needed it fixed for 88yo elderly parent. Had it been and old style furnace I could have fixed it myself in a couple hours. Plumbers are worse than lawyers!
@TheGhettoLobster
@TheGhettoLobster 6 жыл бұрын
@@jenlemay5981 Service fee + diagnostics + markup on part (its 300 dollars their cost) + labor. Not his problem he has to make a living. Plumbers are nothing like lawyers and probably make a 1/3rd of what lawyers ever will.
@dangda-ww7de
@dangda-ww7de 6 жыл бұрын
that is what it cost on average for tankless repair, whenever people call me out i will tell them average tankless cost to repair is minimun $500, all the time and driving to get part and wait for them to deliver, time cost money, if you dont like to pay dont get tankless.
@coryclouser58
@coryclouser58 6 жыл бұрын
Had a Lochinvar noble combi with the same problem! Should put taco pumps in the units instead of Grundfos pumps in!
@ChuckBarron
@ChuckBarron 6 жыл бұрын
Man I love taco stuff. Plumber friendly especially their controls.
@tgamble1000
@tgamble1000 2 жыл бұрын
Navien’s technical support maybe awesome but their warranty claim process is bulls**t! My wife and I bought a new home which had a Navian 240 tankless water heater already installed. Six months after we moved in, the Navian displayed a 060 code. A problem with the Venturi multi-switch. After calling customer service about a warranty claim, I was told a licensed contractor would have to get on the phone with a service tech so the tech could walk the contractor/plumber through the process of diagnosing the issue. Well, I already knew what the problem was by the error code. Once the service tech agreed it was the VMS, I was told Navien would only pay a flat $150.00 for the repair.! When I ask the Navien rep who going to pay the contractor for the diagnosis? I was then told “we don’t pay for the diagnosis”?!!! What you expect him to work for free or for me, the homeowner to pay it!!! It’s a flat $150.00 payout…$75 dollars for drive time, $75 dollars for the repair…total bs!
@pedrolantigua2720
@pedrolantigua2720 4 жыл бұрын
Devén ponerlo más claros
@ChuckBarron
@ChuckBarron 4 жыл бұрын
gotta check translations stand by
@786otto
@786otto 6 жыл бұрын
Pump easy change out but little tricky with that clip in the back, Is good practice to install magnetic filter on the boiler return and boiler water conditioner ,as ad cleaner on old system for two days or so, before installing new unit. Should take your wife or girlfriend with little hands to work on it. Is that boiler installed in primary/secondary loop ,can not tell from video?. Fun video.
@ChuckBarron
@ChuckBarron 6 жыл бұрын
Otto, I feel ya on that clip....Been a while since I did that but I remember the clip...ha. Primary. Its a basement apartment. Baseboard job. works great. I did not pipe it my worker did at the time. I would of did some stuff different but she runs nice.
@786otto
@786otto 6 жыл бұрын
Runs god that's all it counts, enjoy watching your videos.
@pedrolantigua2720
@pedrolantigua2720 4 жыл бұрын
Deven ponerlos más claros
@ChuckBarron
@ChuckBarron 4 жыл бұрын
gotta check translations stand by
@heslind
@heslind 4 жыл бұрын
I’d be more upset that you’re having issues with a brand new boiler.
@ChuckBarron
@ChuckBarron 4 жыл бұрын
Yea for sure.
@BeulahRWalker
@BeulahRWalker 5 жыл бұрын
I will be ordering my T Shirt in Two Weeks 💦💧👩🏾‍🔧
@ChuckBarron
@ChuckBarron 5 жыл бұрын
awesome.....Team!
@edmondfitz7085
@edmondfitz7085 3 жыл бұрын
I agree, Navien tech support is very good. They have to be good , Navien boilers, especially the combi's, are absolute crap. I've worked on enough to know.
@trendwave5615
@trendwave5615 3 жыл бұрын
I wish more techs would confide in tech support to resolve stuff! Must be pride or ego? I had one of these NCB240E installed 2 years ago and still giving an error code 352. Technician has been back at least 15 times to replace parts and it is still not fixed! Company that this tech works for refuses to replace the unit and would rather keep replacing parts.....so frustrating dealing with this stupid Navien junk !
@pineychristian
@pineychristian 5 жыл бұрын
Good video. Navien has great tech support. Too bad their pumps always fail. I have had to do probably a dozen over the years. Seems to be the down fall of that combi boiler
@ChuckBarron
@ChuckBarron 5 жыл бұрын
oh wow.....ok good to know. Thanks JJ...
@dangda-ww7de
@dangda-ww7de 6 жыл бұрын
I dont see how you could make any money on these service call, in order for me to make money on these i would have to charge them over $500 to fix their tankless, all the time u put in and driving back and forth.
@ChuckBarron
@ChuckBarron 6 жыл бұрын
Yes its a time consumer for sure. I do still like them though...just like any heater you cannot carry all the parts. we have so many supply houses here....all 10-15 ride....another story but you get me im sure
@vtail736
@vtail736 6 жыл бұрын
Those wall hung units are a whole different animal. Quite often installing one equals a happy customer for a year or two.. then the service calls begin and it's one thing after the other. Any money they thought they saved in energy costs is chewed up by service call after service call. The day will come when you dread to answer the phone from that customer.. oh well water over the dam now. Installing a strainer in the return line such as a Caleffi 5453 could take care of the pump problems and any possibility of heat exchanger clogging in those small passages..
@ChuckBarron
@ChuckBarron 6 жыл бұрын
Rj, I hear ya. I put about 8 in and have em in my shop to. so far so good but this one seems to be the problem child. I will check out your caleffi idea. thanks plumber.
@mikev.1034
@mikev.1034 4 жыл бұрын
😁👌👍
@ChuckBarron
@ChuckBarron 4 жыл бұрын
got er done. and im going to class soon for navs.
@scottbradley133
@scottbradley133 6 жыл бұрын
Gd job
@ChuckBarron
@ChuckBarron 6 жыл бұрын
thank you and tech support...ha
@patricksimone1238
@patricksimone1238 6 жыл бұрын
A chuck my KZbin channel should be up and running in a week,I’m still in learning stages of editing (real pain in the ass)but anyway I gave you a little shout out in one of my videos about propress check it when you have a chance
@ChuckBarron
@ChuckBarron 6 жыл бұрын
i just check your channel....under your name? if so no content showing up. so many settings to navigate through.
@patricksimone1238
@patricksimone1238 6 жыл бұрын
Chuck Barron a chuck not up and running yet with my channel,need another week to learn this editing stuff,in one of my vids I gave the Barron boys a nice shout out about the propress,I let you no when it’s up
@justinreed7093
@justinreed7093 3 жыл бұрын
the ugly side of tankless anything
@ChuckBarron
@ChuckBarron 3 жыл бұрын
oh yes
@MichaelBushey
@MichaelBushey Жыл бұрын
My experience with owning a Navien is horrible. I despise the company and will replace this junk with another company. Absolute crap and the company is worse.
@ChuckBarron
@ChuckBarron Жыл бұрын
I am happy with them. Im sure they all have issues due to the super tech machines they are.
@gelipeone
@gelipeone 3 жыл бұрын
a 20 min swap turned into a project,lack of knowledge?
@ML-lg4ky
@ML-lg4ky 6 жыл бұрын
Junk!
@ChuckBarron
@ChuckBarron 6 жыл бұрын
Father Time....love your name....Father time is on our side just for today. Not a fan I see. What brand you using? I have had good results so far.
@dcrams16
@dcrams16 6 жыл бұрын
Shut cold water inlet lmao
@ChuckBarron
@ChuckBarron 6 жыл бұрын
oh boy....ha
NAVIEN  COMBI BOILER CIRCULATOR PUMP REPLACED
28:51
Chuck Barron
Рет қаралды 18 М.
WE WANT THEM GONE!... COWS ARE EVERYWHERE!
21:09
Tom Pemberton Farm Life
Рет қаралды 79 М.
Что-что Мурсдей говорит? 💭 #симбочка #симба #мурсдей
00:19
小丑教训坏蛋 #小丑 #天使 #shorts
00:49
好人小丑
Рет қаралды 54 МЛН
Cheerleader Transformation That Left Everyone Speechless! #shorts
00:27
Fabiosa Best Lifehacks
Рет қаралды 16 МЛН
Navien NCB-240 Combi Boiler 3 way Valve Replacement
13:24
Michigan Heating Guy
Рет қаралды 57 М.
Tankless - What to know before you buy
8:04
Matt Risinger
Рет қаралды 834 М.
How to Install a Tankless Water Heater | Ask This Old House
10:50
This Old House
Рет қаралды 2,3 МЛН
The LARGEST Thing We've Machined in 60 years (It's Too Big For The MEGABORE!)
28:48
HAL Heavy Duty Machining Australia
Рет қаралды 108 М.
Diy a simple spot welding at home with capacitors just with 2$
13:47
Navien NCB 240 Water Heater Annual Cleaning - Water Heaters Now
16:14
Water Heaters Now
Рет қаралды 104 М.
clogged toilets Detroit mi
9:35
PARKER BROTHERS PLUMBING AND GOLF
Рет қаралды 29 М.
NAVIEN NCB 240 NEW INSTALLATION  START UP
18:57
Chuck Barron
Рет қаралды 67 М.
NHB Boiler Installation PA Residence
9:56
Navien Inc.
Рет қаралды 140 М.
Hydronics System Components
12:31
Tec Tube
Рет қаралды 388 М.
РЕМОНТ АВТОДОМА!
0:33
Petya English
Рет қаралды 2,5 МЛН
Какая-то скитлстрянка
0:50
Pavlov_family_
Рет қаралды 1,9 МЛН
Застряли на водной горке😳
0:21
FilmBytes
Рет қаралды 1,6 МЛН