Ground Workers Screwed Us

  Рет қаралды 36,013

N Bundy Electrical

N Bundy Electrical

2 ай бұрын

Get 10% off Rhino Trade Insurance using code BUNDY10 at www.rhinotradeinsurance.com/quote
Ansell gloves i wear kzbin.info?even...
Use code BUNDY25 at unilite.co.uk/product-categor... for 25% off
Use code BUNDY10 at www.expertelectrical.co.uk for 10% discount
Join this channel to get access to perks:
/ @nbundyelectrical
This video is for entertainment purposes only and is in no way intended as a guide or 'how to'.

Пікірлер: 96
@brightsparkmid
@brightsparkmid 2 ай бұрын
Thanks so much for all your help on this job, enjoy my time working with you and can see a bright future ahead for us both ! 🎉
@mitchmix999
@mitchmix999 2 ай бұрын
Replace the drawstring with some blue 10mm rope. Then use a Chinese finger trap on the cable end and tie the 10mm on. It doesn't hurt to lube the cable if it's a long run as well.
@johnhoulihan4000
@johnhoulihan4000 2 ай бұрын
Agreed, blue polypropylene rope, cheap and strong.
@Gr33nMamba
@Gr33nMamba 2 ай бұрын
When Nick said drawstring, a multi-threaded rope was exactly what I was expecting.
@RobTheSquire
@RobTheSquire 2 ай бұрын
I just use a ferret
@medwayspark8244
@medwayspark8244 2 ай бұрын
Just for the kids out there. The two 5.pole breakers are in parallel not series. I hope they are linked so as a fault trips both or that could have big consequences. I'm sure it could have been mechanically linked with a channel over the two arms. But as it's a custom made unit I'm sure it's all been properly designed.
@Emin3m1986
@Emin3m1986 2 ай бұрын
I was looking for you comment mate! Yes, they are in parallel not in series. and yes, your solution about having them linked with a channel I guess is the best solution!
@markrainford1219
@markrainford1219 Ай бұрын
If they trip on overload they will both trip anyway. The last one quicker than the first to go.
@nickbooth161
@nickbooth161 Ай бұрын
​ True, but that's not the best practice. At the speed the second one will trip at. It may be a one trip and bin.
@tonywatson1412
@tonywatson1412 2 ай бұрын
You,ve got one of those screwdriver shaped hammers , as well 😅
@olly7673
@olly7673 2 ай бұрын
Good video to watch Nicholas. Personally, I would have pulled a blue poly rope through with the cable (8'10") for possible future needs, such as Cat 6. When you used the step/ cone cutter on the alloy (9'50"), I would have sprayed the bare alloy with black paint to protect it, and (12'40") it is good to get a preview of the new Knipex electricians light duty, rubberised hammer. .. 😂😂 A nice looking install at the end of the day though, good one.
@MarcusNailor
@MarcusNailor 2 ай бұрын
12:50 weird looking hammer 😂 Proper tidy looking job, though!! Good luck on a Doncaster Cables tour 🤞
@blower1
@blower1 2 ай бұрын
Everything is a hammer to an electrician :)
@chrissharpe2106
@chrissharpe2106 2 ай бұрын
And today Nick learned that, when following ground workers on to site, you ALWAYS leave time for fixing their work for them.
@heladas90
@heladas90 2 ай бұрын
Or for going to supervise them
@robinhadley
@robinhadley 2 ай бұрын
Here's me thinking DeWalt would be right up your street with it being the batman logo colours 🦇
@russellwestern6997
@russellwestern6997 2 ай бұрын
Because they laid it on a friday afternoon and thought bllcks to cutting the duct at every pit! Screw the sparks as always!!
@boblordylordyhowie
@boblordylordyhowie Ай бұрын
I was on a job a few years back where the groundworkers installed ducting a metre deep but a bit like yours did it completely wrong. They ran a duct around the site but only put one tube to the access point and taped it to the underground pipe with tape. It took us ages to fish out the rope they installed but it was made more difficult by the two feet of water in the duct due to them using field drain pipe instead of actual ducting plus the taped joints.
@MartynSmith
@MartynSmith 2 ай бұрын
My god Nick is now mining for flex conduit now!
@NBundyElectrical
@NBundyElectrical 2 ай бұрын
😂😂
@maticdesigns2042
@maticdesigns2042 2 ай бұрын
I can confirm leaving your van open in and around Doncaster is a terrible idea 😂😂 especially with the Milwaukee kit
@maticdesigns2042
@maticdesigns2042 2 ай бұрын
As I recognise the unitas wholesale building near lakeside I can confirm bad idea
@joesouthgate
@joesouthgate 2 ай бұрын
The van you head is called the "BapVan" I used to work for a company on that estate that ironically do ev chargers
@steveday6104
@steveday6104 2 ай бұрын
Nice work chaps, love a good commercial job.
@Morbazan125
@Morbazan125 Ай бұрын
Experienced many situations of contractors doing whatever is easiest for themselves and screw it if it makes things more difficult for anyone else😂
@staypufttechtank
@staypufttechtank 2 ай бұрын
Nice video - enjoyed 100%, thanks Nick. Loving the AI comments about 'camaradarie' and 'wealth of wisdom' - totally right of course...
@andycriddle7316
@andycriddle7316 2 ай бұрын
Another cracking video Nick keep them coming! 👏🏻👏🏻🔥🔥
@rowles13
@rowles13 2 ай бұрын
Brilliant video ❤..good to have a change 👍
@troyboy4345
@troyboy4345 2 ай бұрын
EV uptake through company schemes are always a good idea ... But some people can't do the Maths .... keep up the good work Nick ... it's all good money, Adams Mum sends her love.
@stormuk69
@stormuk69 2 ай бұрын
Make sure to power the Easee units and get the firmware updated first. I spent a long time thinking my Easee was screwed because the Megger EV tester kept on producing PE Errors and wouldn't test. After the Firmware update and reboot it was perfect.
@brightsparkmid
@brightsparkmid 2 ай бұрын
Had the same issue before mate too so it’s the first thing we did when setting up
@Hoops-Senior
@Hoops-Senior 2 ай бұрын
You should create a line of Telly-Tubby dolls as the Bundy Groupies.
@andycriddle7316
@andycriddle7316 2 ай бұрын
Well took me to watch until the very end for you to say about a visit to Doncaster cables for me to find out you are defo not in Bristol! 😂😂😂
@bencampbell2041
@bencampbell2041 2 ай бұрын
Thought the estate looked familiar but the batman Sandwich van was the last clue in the jigsaw puzzle
@jnewton86
@jnewton86 2 ай бұрын
Should never trust that pull cord (it snaps(a lot!)). Always replace with bt cord mate.
@andycriddle7316
@andycriddle7316 2 ай бұрын
Must be Bristol if you got the bap mobile flying around!! 😂😂
@maticdesigns2042
@maticdesigns2042 2 ай бұрын
We have bap van in Donny aswell
@catmantech
@catmantech 2 ай бұрын
Are all those chargers going to be on a radial or a ring circuit, with all the potential current draw?
@michaelscott3401
@michaelscott3401 2 ай бұрын
using a cable sock would make the job easier just a thought pulling the cable through the ducting.
@KevinOsborne1987
@KevinOsborne1987 2 ай бұрын
All sites ruin the ducts without fail there will always been 1 collapsed or filled with mud 😢
@stevecraft00
@stevecraft00 2 ай бұрын
How did you end up working in Doncaster? My home turf. The bap van actually calls at our depot!
@davidryan6616
@davidryan6616 2 ай бұрын
Always Great Work 🧐🙂🇮🇪☘️
@travoltasbiplane1551
@travoltasbiplane1551 2 ай бұрын
You sure about that current rating chaps 122amps? What temperature are you running it at and what rating factors applied?
@russellwestern6997
@russellwestern6997 2 ай бұрын
I make it 75 and absolute max of 94
@stephenrowley4171
@stephenrowley4171 2 ай бұрын
That's only tiny tiny breaker. Come back when you can climb inside one.
@MrDleete-mj9vt
@MrDleete-mj9vt Ай бұрын
Bollards are required iaw bs7671
@pmbpmb5416
@pmbpmb5416 2 ай бұрын
What is it with trades not thinking about what others have to do afterwards ?
@user-gz6sy3cj4o
@user-gz6sy3cj4o 2 ай бұрын
by opening those mounting holes on the pillar, he just voided the warranty on it...
@Malandrin
@Malandrin 2 ай бұрын
nice big dark oriffice nick!
@chris_hertford
@chris_hertford 2 ай бұрын
Almost missed the cameos from Margot Robbie and Megan Fox!
@laujovo5368
@laujovo5368 2 ай бұрын
At 16:19, what's the matter with the apparently switched PE? Why is that even legal to do?
@brightsparkmid
@brightsparkmid 2 ай бұрын
As per regs, in fault conditions the PE should be disconnected with EV as they are automatically controlled MCB they will operate when the O-pen unit sees a fault,
@chas3997
@chas3997 2 ай бұрын
Surely it still needs a ref for zero volts to see a pen fault how does it get that?@@brightsparkmid
@chas3997
@chas3997 2 ай бұрын
Presuming it sees it with a rise in touch voltage over 70volts
@anthonybragg
@anthonybragg 2 ай бұрын
Looks like you're enjoying doing something different.
@Rich-Eclipse
@Rich-Eclipse 2 ай бұрын
Which Easee chargers are they? Sure the Easee one has PEN fault protection built in?
@brightsparkmid
@brightsparkmid 2 ай бұрын
They are the 10223 so don’t have PME protection unfortunately The ease one however does but not great for commercial use
@Rich-Eclipse
@Rich-Eclipse 2 ай бұрын
@@brightsparkmid ahhh got you! Everydays a school day 👍
@brightsparkmid
@brightsparkmid 2 ай бұрын
@@Rich-Eclipse I questioned it the first time I did these too as the whole idea of easse is that it’s easy lol 😂 Still a great charger to use and set up though
@Rich-Eclipse
@Rich-Eclipse 2 ай бұрын
@@brightsparkmid done a few of the Easee one’s for domestic clients, very easy to install and setup
@brightsparkmid
@brightsparkmid 2 ай бұрын
Ye they are spot on to be honest,
@russellwestern6997
@russellwestern6997 2 ай бұрын
Maybe don't put the bollard on the lid tho??
@MrDleete-mj9vt
@MrDleete-mj9vt Ай бұрын
Yeah i was thinking the same thing.... The clearance isnt much and it wouldnt take much to dislodge the whole ground work....
@sygad1
@sygad1 2 ай бұрын
you've corrupted me, as soon as you dark orrifice, I immediately jumped to thinking Adam's mum
@andycriddle7316
@andycriddle7316 2 ай бұрын
Or is this the Birmingham branch?
@fireblaster9961
@fireblaster9961 2 ай бұрын
What I don’t get is we all installing the odd charger at work but juts look how many cars are in that car park......this is so stupid it can’t be the future
@ef7480
@ef7480 2 ай бұрын
Correct- It isn't but they will try to convince you it is.
@stormuk69
@stormuk69 2 ай бұрын
@@ef7480 Exactly.. Once they have enough reeled in something else with rise to the surface....
@Damiensgarage
@Damiensgarage 2 ай бұрын
There is government grants for them so company's can right them off on tax etc there is more incentives to a company they might have only 2 electric cars in the company 😂😂
@TurboAdam
@TurboAdam 2 ай бұрын
Eventually they’ll just charge a premium to be able to charge when the grid is “maxed out”. Ya can’t afford to charge?? Hmmm…sorrrrry
@Monkeh616
@Monkeh616 2 ай бұрын
They said the same when gas lighting started rolling out. And then electric lighting. Not every car will need to be charged every day at every stop..
@ceangasrevenge
@ceangasrevenge 2 ай бұрын
Clown Shoes !
@dimitar4y
@dimitar4y 2 ай бұрын
lol!!
@wintersun398
@wintersun398 2 ай бұрын
Why not specify a charge point that has the built in fault protection? Does anyone else get annoyed when they are called chargers!?
@mwkp38
@mwkp38 Ай бұрын
Thought Easee ones did?
@daniellittle757
@daniellittle757 2 ай бұрын
Hope your up to date with you vaccines using dewalt stuff
@SomeToastyBread
@SomeToastyBread 2 ай бұрын
First
Dangerous? Never Seen This Before?!
21:55
N Bundy Electrical
Рет қаралды 34 М.
Horrific LED tester that can literally kill you - (with scary schematic)
15:48
Always be more smart #shorts
00:32
Jin and Hattie
Рет қаралды 48 МЛН
МАМА И STANDOFF 2 😳 !FAKE GUN! #shorts
00:34
INNA SERG
Рет қаралды 4,9 МЛН
That's how money comes into our family
00:14
Mamasoboliha
Рет қаралды 9 МЛН
Why I'll NEVER Hire Another Tradesperson
14:31
Rag 'n' Bone Brown
Рет қаралды 144 М.
Digging A SECRET GARAGE Part 1
24:22
colinfurze
Рет қаралды 9 МЛН
Im Finished
21:31
N Bundy Electrical
Рет қаралды 26 М.
The CAR WIZARD Shares 6 CHEAP Vehicles to NEVER Buy!
14:51
Car Wizard
Рет қаралды 179 М.
Customer Didn't Want To Pay
16:04
N Bundy Electrical
Рет қаралды 70 М.
HEATING NEVER INSTALLED CORRECTLY - Bart's MASSIVE Problem!
22:09
plumberparts
Рет қаралды 67 М.
I Found The Weirdest German Hand Tools EVER!
25:47
Shadow Foam
Рет қаралды 399 М.
Nearly KILLED by a CRAZY fault! What on earth is going on? 💀
27:12
Artisan Electrics
Рет қаралды 677 М.
Fuseboard Fire, House Fire, Exotic life of an Electrician
34:29
N Bundy Electrical
Рет қаралды 201 М.
POR QUEEE DIVERTIDA MENTE 2 !!! #SHORTS
0:15
Figuritalo
Рет қаралды 26 МЛН
Какая Милота ❤️
0:10
Глеб Рандалайнен
Рет қаралды 6 МЛН
Гениальный План Хвостатых 😂
0:28
ДоброShorts
Рет қаралды 2,4 МЛН
МЛАДШАЯ СЕСТРА И МОРОЖЕНОЕ ИЗ АРБУЗА
0:41
ОЛЯ ПЕРЧИК
Рет қаралды 1,6 МЛН