OPEN PEN CONDUCTOR ☠️

  Рет қаралды 1,091

Mainly electrical

Mainly electrical

Күн бұрын

Join this channel to learn
/ @mainly_electrical

Пікірлер: 9
@warren7949
@warren7949 4 күн бұрын
Very informative, thanks
@martinbradley7024
@martinbradley7024 5 күн бұрын
Love it, working on the highway this is a must.
@Mainly_Electrical
@Mainly_Electrical 5 күн бұрын
Definitely bradders .. hope you're well mate 👌
@alanjewell9550
@alanjewell9550 3 күн бұрын
It always amazes me how such an inherently dangerous supply system has become "Standard", all to save a bit of cable cost. It also results in noisy earths even without a fault. Identified two open pens in the last few years, both by a quick clamp meter check.
@BULLEAD
@BULLEAD 4 күн бұрын
How many times have you isolated the installation and disconnected the earthing conductor to do a Ze without checking for current on the earthing conductor? I would say that there are a lot of sparks who have been very lucky in the past.
@alanjewell9550
@alanjewell9550 3 күн бұрын
Spare a thought for plumbers. If the pen conductor is broken, the neutral can often divert through pipework. Some plumbers connect a jump lead if they are breaking an incoming metal supply pipe.
@LordLorenzo834
@LordLorenzo834 4 күн бұрын
Nobody is clamp metering the main earth before a Ze is my opinion. My company is big and had procedures but this ain't one, which is surprising when I think about it as that's a real risk
@UCCLdIk6R5ECGtaGm7oqO-TQ
@UCCLdIk6R5ECGtaGm7oqO-TQ 5 күн бұрын
Aye, no joke, it does happen. Be careful of complacency catching you out.
@Mainly_Electrical
@Mainly_Electrical 5 күн бұрын
@@UCCLdIk6R5ECGtaGm7oqO-TQ 💯
10 Mistakes EVERYONE Makes When Doing DIY Electrics!💥
11:56
Artisan Electrics
Рет қаралды 225 М.
Diverted neutral Currents -  Is our electricity supply safe?
14:22
When Cucumbers Meet PVC Pipe The Results Are Wild! 🤭
00:44
Crafty Buddy
Рет қаралды 58 МЛН
Twin Telepathy Challenge!
00:23
Stokes Twins
Рет қаралды 108 МЛН
Farmer narrowly escapes tiger attack
00:20
CTV News
Рет қаралды 6 МЛН
كم بصير عمركم عام ٢٠٢٥😍 #shorts #hasanandnour
00:27
hasan and nour shorts
Рет қаралды 10 МЛН
What is the Difference Between a Short Circuit and a Ground Fault?
16:18
"BOSS FAULTS GALORE !!" 🤷‍♂️
9:46
Mainly electrical
Рет қаралды 416
Insulation Resistance
6:17
Master Electricians New Zealand
Рет қаралды 18 М.
This Is Why Builders SHOULDN'T Do Electrics! 🫣
19:59
Artisan Electrics
Рет қаралды 62 М.
Four Steps to Flawless Wire Joints (How to Solder)
11:45
Will Donaldson
Рет қаралды 539 М.
How to Extend Short Wires | Easy Fix Anyone Can Do
6:52
The DIY Guy
Рет қаралды 3,3 МЛН
Flawless PCB design: RF rules of thumb - Part 1
15:45
Hans Rosenberg
Рет қаралды 90 М.
25 YEARS IS INSANE 💀
9:47
Mainly electrical
Рет қаралды 6 М.
Why Circuit Breakers DON'T Protect People (electric shocks)
18:23
The Engineering Mindset
Рет қаралды 1,5 МЛН
When Cucumbers Meet PVC Pipe The Results Are Wild! 🤭
00:44
Crafty Buddy
Рет қаралды 58 МЛН