@AnonYmous-lb1dv
@AnonYmous-lb1dv 3 жыл бұрын
Thanks Sir Chubb Sir, excellent video!!
@desertzombie
@desertzombie 7 жыл бұрын
Love that they covered the potter name on the switch but no the symbol
@dk1245
@dk1245 6 жыл бұрын
I work for a National fire protection company and sprinkler systems have to be tested Annualy. An OS&Y doesn’t have to be tested monthly. Some AHJs have different rules. I think New York is monthly, but that’s not because NFPA25. We do big commercial buildings. I was hoping u touched on UL listing and such.
@GamingwithGamerGirls
@GamingwithGamerGirls 3 жыл бұрын
Outside Stem and Yoke. (OS&Y)
@rehanzahid9600
@rehanzahid9600 4 жыл бұрын
Sir , can you explain about the zone control valve & for what purpose we install this on main line and please explain about each equipment with zone control valve
@toddavis8603
@toddavis8603 Жыл бұрын
Thankyou sir.
@jjosh_sprink
@jjosh_sprink 8 жыл бұрын
Nice Video
@SafeFireControl
@SafeFireControl 9 жыл бұрын
What type of valve is recommended for sprinklers in NFPA 13? : Butterfly or gate? What kind is recommended in the main pipe fire system? I mean to do maintenance operations or to close some main pipe system sectors? Butterfly or gate? Thanks so much for your support. Congratulations for your movies.
@diegoovando9584
@diegoovando9584 7 жыл бұрын
David Cervetto nice
@foysalbappy6217
@foysalbappy6217 7 жыл бұрын
David Cervetto it's butterfly valve with supervisory
@NazeoAelkoNezen
@NazeoAelkoNezen 4 жыл бұрын
I've seen both Outside Stem & Yokes as well as Butterfly control valves used on both sectionals as well as main sprinkler system piping. Most often in my experience outside stem & yokes are installed when supervision is not a consideration ( substituting the tamper switch with a lock and chain whereas butterflys often come with it's own wiring ready to be installed and tied back to the fire alarm control panel. It also depends if your valve comes pre-packed with it's own trim ( which most often is a butterfly valve ). Check with local authority having juristiction and nfpa 13/25 codes as well as manufacturer's instructions before installing.
@zombiediarhea
@zombiediarhea 6 жыл бұрын
Therman merman
@jwhitaker1507
@jwhitaker1507 7 жыл бұрын
The alarm panel said Tyco dry system, but it's Reliable, am I wrong?
@NazeoAelkoNezen
@NazeoAelkoNezen 4 жыл бұрын
You are correct, it is a Reliable valve, not a Tyco. It is either a 4" Reliable Model D Dry Pipe Valve, or a 4" Reliable Model E Wet Alarm Check Valve.
@user-sm9hh9hz8j
@user-sm9hh9hz8j 5 жыл бұрын
You did well 👏👏👏 Go ahead . BUT : OS & Y means ; "outside" stem & yoke . Not "open" stem & yoke .
Know More Risk: Wet System -“ Alarm Check Valve
4:37
FM Global
Рет қаралды 144 М.
100❤️
00:19
MY💝No War🤝
Рет қаралды 21 МЛН
Жайдарман | Туған күн 2024 | Алматы
2:22:55
Jaidarman OFFICIAL / JCI
Рет қаралды 1,8 МЛН
Replacing a 4" Fire Sprinkler OS&Y Valve
10:31
Fire Sprinkler Tech
Рет қаралды 1 М.
Gate¥ Valve Manufacturing Process. The Most Amazing Production Factory
16:50
Amazing Skills Discover
Рет қаралды 33 М.
Viking Double Interlock Preaction System - System Reset Procedure
3:58
Viking Sprinkler
Рет қаралды 93 М.
ITM Wet System Riser, Backflow and Connections
4:08
Northern Illinois Fire Sprinkler Advisory Board
Рет қаралды 32 М.
How To Do Hydrostatic Testing Or Pressure Test For Valves | Gate Valve
10:22
OS&Y, FDC and PIV
7:33
Fire Education and Prevention w/ Eng Osborne retd
Рет қаралды 12 М.
How to install a wafer type body butterfly valve between flanges
5:16
OS&Y Fire Sprinkler Riser Valve Overview and Test
6:35
kcin556
Рет қаралды 32 М.
TYCO® DPV-1 Dry Pipe Valve Installation
5:15
Fire Protection Products from Johnson Controls
Рет қаралды 25 М.