Join Certified Professional Inspector®, Kevin Baker as he inspects this new build in Colorado Springs, Colorado! For more education visit nachi.org/education
Пікірлер: 47
@theallaroundguy2399 Жыл бұрын
If you have a chance to put your ladder in a corner where you can safely step off to the side that’s always better than an open face area of a roof
@internachi9 ай бұрын
That's a good safe practice procedure for using a ladder that I have used.
@orangeblossomhomeinspectio432 Жыл бұрын
Thank you to Mr. Baker, AmPro Inspection, Ben, and everyone behind the scenes at InterNACHI! John Grimaldi Florida CMI and InterNACHI Home Inspector Mentor
@internachi9 ай бұрын
Thank you for watching.
@farstrider79 Жыл бұрын
There at 18:00, next to the furnace flue, ehat was yhst copper pipe that looked like it had a meter on it? Also, i would have tried to run the garage door with the GFCI tripped to make sure they weren't wired together. And when testing gas cooktops, make sure you turn the onon down to the lowest setting to see if it stays lit. If it goes out when it should be on s simmer setting, gas can build up in the house. They may need calibration.
@internachi11 ай бұрын
Good reply. Thank you for watching.
@farstrider7911 ай бұрын
@@internachi Do you know what that pipe is? I was guessing maybe gas. It just looks different from what I've seen.
@CoreyLambrecht9 ай бұрын
Looks like its for a lawn irrigation system. @@farstrider79
@cylentsmoker5 ай бұрын
Hey im in the springs area, been my whole life pretty much. I recently discovered my interest in home inspections. That's because ive worked trade jobs for the past 10 years.... And ive worked for a lot of bosses doing practically all types of construction-restoration. Seen it all. Thank you for sharing this video! How can i job shadow for a day?
@internachi5 ай бұрын
Thanks for watching.
@robertotis5173 Жыл бұрын
Don’t forget to be sure the sinks have overflows when filling up because not all do.
@internachi11 ай бұрын
Right. Good point.
@CoreyLambrecht9 ай бұрын
I like how he carries a tool bag from room to room instead of trying to load up his body with 20 pounds of stuff. Efficient and professional looking.
@internachi9 ай бұрын
Agreed. Thanks.
@christopherwilkie2351 Жыл бұрын
open nuetral not open ground, according to your tester.
@theallaroundguy2399 Жыл бұрын
It really doesn’t matter. Just notate that the outlet is improperly wired and to have it repaired by a licensed electrician
@farstrider79 Жыл бұрын
@@theallaroundguy2399You need to be accurate with your description. The electrician might very well say that you called it wrong and it'll make you sound bad.
@internachi9 ай бұрын
That's a good catch. Yes. Thanks for posting.
@joseleon863_ Жыл бұрын
Just curious but if I were to join, would I be able to perform commercial roof inspections as my own company ? Or just residential
@theallaroundguy2399 Жыл бұрын
Joining would not affect what you can inspect. InterNACHI is just a place to learn and get certifications. The certifications are not recognized by your state or the government.
@joseleon863_ Жыл бұрын
@@theallaroundguy2399 so you don’t need any form of licensing to perform roof inspections ? Like if I wanted to start roof inspection company specifically, I don’t need a license of any sort to perform inspections in the state of Florida
@theallaroundguy2399 Жыл бұрын
@@joseleon863_ i’m not for sure about the state of Florida. I know in a lot of states you don’t even need a license to be a home inspector. I know in a lot of states there is no such thing as a licensed roofer.
@internachi Жыл бұрын
Yes. I would look into the following: www.nachi.org/certified-roof-inspector.htm and then try www.nachi.org/contractor.htm and then try commercial roof training at ccpia.org/
@cigarsandwhiskey46669 ай бұрын
Do you have or recommend an app for compiling pictures and notes to compile information?
@internachi9 ай бұрын
That's what we refer to as inspection report writing software. And you can find some at inspectoroutlet.com/collections/software
@nohandsdan9353 Жыл бұрын
Hmmm... InterNACHI says to use a 2x4 for the resistance test on the garage door and never to use your hand to prevent any mechanical damage. I just passed the InterNACHI garage inspection course before watching this 😉 Great informative video though!
@farstrider79 Жыл бұрын
Have fun paying for a new garage door when it fails to stop and bends the bottom panel, or breaks the gears. You've just performed a destructive test!
@nohandsdan9353 Жыл бұрын
@@farstrider79 Better tell Ben to change the course and InterNACHI standards for garage door test if that's the case or should we just send them the bill since that's how it was taught?
@internachi10 ай бұрын
Thank you for watching and commenting.
@arqgus2471Ай бұрын
@@internachi yep, but you don't say anything useful regarding these comments and the way to test the garage door though ...
@electricpeachfilms11 ай бұрын
thank you
@internachi10 ай бұрын
You're welcome
@theallaroundguy2399 Жыл бұрын
As an instructional video you should’ve went ahead and talked about how you made sure that that was wired as a sub panel and not the main panel. Just a thought
@internachi Жыл бұрын
Good recommendation and comment. Thanks for the feedback and watching the webinar and video.
@robertotis5173 Жыл бұрын
Do I see a power vent on the water heater?
@internachi Жыл бұрын
Good question for the presenter.
@farstrider79 Жыл бұрын
Yes, that's what it looked like.
@theallaroundguy2399 Жыл бұрын
Not having all the water sources continuously running during the entire inspection is a big mistake. You’re missing so many plumbing repairs that you do not even know about. Leaky drain pipes, leaky supply lines, leaking faucet arms and control knobs, you’re missing a possible plumbing back up from a blocked Main drain line. Tubs and sinks with slow drains etc. Running all of the water the entire time at the inspection is probably the most important thing a HomeInspector can do
@marcusruth6612 Жыл бұрын
Kind of agree here. At least all the fixtures in a room or two to put the system under a simulated "typical load".
@theallaroundguy2399 Жыл бұрын
@@marcusruth6612 no, the short time you are there you want to overload it. By doing that hopefully you are ensuring that things will be OK under a typical load. Like test driving a car, everyone floors it and slams on the brakes and does stuff they would not typically do
@internachi Жыл бұрын
Good recommendation and comment. Thanks for the feedback and watching the webinar and video.
@KevinBaker-xk5bh9 ай бұрын
Every Company has a different policy for there procedures, ours is to run all fixtures within that room at the same time, fill to over flow then drain. If you have made a video for internachi you would know A LOT of items are edited out.
@theallaroundguy2399 Жыл бұрын
I’ve never met a fireman who did not somehow have to tell you that he was a fireman🤦♂️🤦♂️
@internachi Жыл бұрын
Ha. Nice.
@farstrider79 Жыл бұрын
It's a requirement, like vegans! 😂 No hate, I love firefighters and vegans both!
@robertotis5173 Жыл бұрын
Self venting good practice for a new build? No go around here. Mechanical vents can fail