Need a brief specification and grading of stone chips to be used in pile also, of course it must be in the IS2911, Thank you for your excellent lecture 👍
@bilalakhtar34702 жыл бұрын
Best explanation of pile foundation
@jayalakshmisubbaraj95398 ай бұрын
Excellent explanation.. Thank u so much. Keep up the good work..
@vishwa024 жыл бұрын
Great work, but we want some more things like - 1.how cutting length and socketing of pile is decided.2 how pile calculation is done in sand and clay for circular pile?
@shradhadongre23036 жыл бұрын
Thank you 😊
@pediredlasatyanarayana60365 ай бұрын
❤Excellent Sir
@surenderchaudhari-yq2fz11 ай бұрын
What is the tolerance allowed for 1. ROW to ROW pitch distance 2. Vertical distance 3. Clear cover
@debankurbaruah57284 жыл бұрын
Good Job. Nicely explained
@r.m.consultants5093 жыл бұрын
Very good narration what us rhe specification of pile load test Is it necessary to conduct static and dynamic load test for pile load test
@teja17074 жыл бұрын
very use full thank you.
@shahanawajsayyad60685 жыл бұрын
How design single pile with cap
@abc-e.c3 жыл бұрын
What is the load bearing capacity of 1 fit dia pile the depth of file is 12 feet
@Structure01567 ай бұрын
How to find depth of pile....?
@rahathussain6012 жыл бұрын
I'm doing pile foundation in kolkata metro right now
@rupeshkhandekar63403 жыл бұрын
if uplift is present what shall we do?
@debasishgouda70472 жыл бұрын
Thank you sir
@sarveshtripathi47923 жыл бұрын
What is the criteria for pile liners design
@samruddhi33263 жыл бұрын
What ia the settelment criteria for Pile foundation
@stockmarketlearningbyjayes29502 жыл бұрын
Superb... please also explain same about pile load test , routine load and Initial load
@vijaypatil93853 жыл бұрын
Why permanent liners are used for bored cast in situ pile foundation.. What are criteria for that? Mainly water and soil?
@prashantkumar-ii9nu2 жыл бұрын
permanent liner are provided where u have to excavate the pile for certain depth and for smooth finish
@Ashokkumar-bf7qw10 ай бұрын
When total soil is loose or soft condition in such case Permanent liners used and liner thickness should be min 6 mm
@sagardas48884 жыл бұрын
Lovely video
@gbsathyalaksshmi14244 жыл бұрын
sir , Edge distance should be minimum d or 150mm? please clarify. also please help me how will we decide on the basis of soil report and n values and sbc values and ground water table, what type of foundation is required. if it is pile, what length to give?
@dirthrules3 жыл бұрын
Pile length should be sufficient enough to carry the vertical pile capacity and reinforcement of the pile should be evaluated on the basis of Lateral Load on the Pile.
@kunalpatil71464 жыл бұрын
Sir also upload pile cap design
@dharmeshreddy97642 жыл бұрын
Sir , These are the details for a protection wall along river bank Existing ground level - 12.600 River bed level - 7.130 Ground water table located at - 3.00mts below ground level What should be the pile cut off level ..?