I have subscribed... I like how you teach with real life eg.
@MohamedAli-fn8kh4 жыл бұрын
Excellent
@chinnakarlapraveen99664 жыл бұрын
Thank you so much sir
@chaduvulahemanth39744 жыл бұрын
happy to know this information. Thank you sir
@suryanath84644 жыл бұрын
Videos from this channel are superb !!
@sureshbabu-tj8fl4 жыл бұрын
Excellent...Thank you for the service 👍👍
@tel46ninadyadav794 жыл бұрын
Thanks for this unique info sir
@jeenusrinu87964 жыл бұрын
Hii sir.i want to measure 15 amps.but meter shows 14 amps while doing practical.meter maximum reading is 20 amps.then you can explains error calculation for different error symbols you explained.
@devendrasingh84034 жыл бұрын
Thank you sir good keep it up Sir i m sharing this video to my friend also Good day
@rishigautam92954 жыл бұрын
Awesome..
@zaidi0to14 жыл бұрын
Thanks for listening to my advise .
@anilpperisetla4 жыл бұрын
Sir please make a video on , why semiconductor material is used in underground cables 11kv above,and their advantages.
@periyasamy7744 жыл бұрын
Thank you Sir...
@prakhyathmunna2544 жыл бұрын
Nice one !
@electricallearner4 жыл бұрын
Sir why we are connected #live wire right side on switch board #socket?
@satyabrata1804 жыл бұрын
Very nice sir
@prudhvirajrouthu39274 жыл бұрын
Sir... plz explain how work solar fence energiser.
@alammd.samsul84244 жыл бұрын
ive a used- heavy machine stiker worn out ,how i place her ,where can i get a help,vaiaaaa.......with love amd.
@sujoybhattacharjee45004 жыл бұрын
Sir I have a little doubt.If the instrument has full scale value of 30 volt, then how can it be tested at 500V or 2kV?
@akashkarmakar15724 жыл бұрын
I think to test those instruments sustainability with a very short period of time like 500ms or 1s.
@akashthore994 жыл бұрын
Large voltages can be stepped down upto a particular range which your instrument can record and then you should multiply that reading by the factor which the voltage was stepped down. In short, that's what PT( power transformer) is used for and similarly CT( current transformer) for measuring high currents. Hope that helped!
@30mAkills9 ай бұрын
I will tell the procedure: All current carrying terminals are shorted or jumpered together. The reqd high voltage is injected between the terminals and non current carrying metallic frame or body. The device should withstand this test for 1 minute without any damage/failure. Note that higher the withstand voltage higher the cost. This test is known as HV withstand test. The voltage is selected based on historical data, otherwise it will be destructive. Meggering test is another common test done for testing the integrity of Insulation resistance. The injection voltage is usually 2x of normal working voltage of the device. Hope this info helps.
@30mAkills9 ай бұрын
@@akashthore99 inappropriate
@jeenusrinu87964 жыл бұрын
Sir above mi ammeter you shown scale is non linear .if current shows between 0 to 5 amps then how to read the current manually in this condition.this is my doubt.please explain
@bandarikishore0214 жыл бұрын
Make a video on energy meter and how to calculate electricity bill sir
@northkoreasupremeleaderoff7214 жыл бұрын
Maths demo lectures link wr?
@r.saisundarsharma55534 жыл бұрын
Anna if we send 11kv we get 10kv as 10 percent drop, so do the 11kv motor required 10kv🤔🤔
@gnanavel164 жыл бұрын
Really appreciated. Thank you.
@Pradeepdurgam4 жыл бұрын
How to identify a motor rating without nameplate details please explain???
@sridhargedela7364 жыл бұрын
sir if one(1) is inside star symbol then 1kv was tested?
@divyasrijayini2494 жыл бұрын
Because of gravitational force we have to keep flat..our sir said
@AbhilashKsupernovaabhi4 жыл бұрын
Awesome Loved it. I was searching about it in Google & was unable to find it.
@r.saisundarsharma55534 жыл бұрын
They said gravity will effect reading AND later by E.Intruments I thought reading may change incase of GRAVITY ONTROL
@AbhilashKsupernovaabhi4 жыл бұрын
Hello Sir, In ammeter there indication "B" after stars what does it mean