I work for a municipality that of course locks its employees out of KZbin. I spent about three hours today trying to figure out how to add a PF525 to my RSLogix 5K project. Started out I could not see the PF525 in add devices so I spent a great deal of time on RA knowledge base to find the answer. To make a long story short I finally got it configured and moving along. Along my path to enlightenment I had ran across this video, once again can not view it at work. Upon getting home with my tail wagging with excitement looking forward to see what this video entails. I pour myself a cold drink and fire up my pc and watch the video. WOW!!! If I could have seen this video at work the hours it would have saved me. I would like to thank you for putting this awesome video up I have subscribed to your channel and will definitely share with my network. Looking forward to your future post. Thanks again.
@PLCAutomationTraining9 жыл бұрын
Frank Dominguez Thank you for the feedback it means a lot and keeps me motivated to continue adding more videos to help those who need it. KZbin is a great place, i don't understand why some companies block it. I make a lot of these as a refresher for myself as well.
@richardarendt71754 жыл бұрын
Thank you very much. I had figured out a lot of it but there were a few things that I never would have guessed. Good Tutorial... got me up and running!
@PLCAutomationTraining4 жыл бұрын
You're welcome, I am glad this video was helpful for you!
@gameslayer647 жыл бұрын
Thanks for the video it came in very handy with trying to add a VFD to my PLC I didn't have high hopes when starting to look for information on how to do it so I am glad you posted this video.
@Saurabh_Gambhir3 жыл бұрын
Your videos are so informative. Please make regular videos on rs logix 5000 .you are awesome.
@guilhermecarneiro21162 жыл бұрын
Great video 👏👏👏
@AngelGonzalez-to2ob5 жыл бұрын
Great video. I learned in this video what i had not learned in hours of reading. Thank you!
@Ranjit3998 жыл бұрын
Informative. Concise. Nicely done.
@BrianCB28 Жыл бұрын
Excellent tutorial! Thank you.
@irfaaankhaaan5 жыл бұрын
Excellent. !!!! What a life saviour video !!! Thanks mate
@ziyaddinyusupov443311 ай бұрын
Very informational. Thank you
@mattaustin9228 күн бұрын
thank you very much. this was explained well and it was just the information I needed!
@PLCAutomationTraining28 күн бұрын
@@mattaustin92 I’m glad this was able to help you out! Thanks for the watch!
@nashwanalshargabi98605 жыл бұрын
Excellent job. Thanks
@disun41525 жыл бұрын
Amazing tutorial video. I was much impressed by the clear English voice and good knowledge. I have subscribed the author videos already. The first time I have ever subscribed a you tube author. I will be watching more on this Author's other videos. I am interested in Siemens stuff as well
@lpfagundeseai9 жыл бұрын
Very nice video!!! I'll show this video to my students and i hope they enjoy it as mush as i do. Thank for share your knowledge!
@PLCAutomationTraining9 жыл бұрын
No problem let me know if I can help in other tutorials!
@hectormb885 жыл бұрын
Great video. Easy to understand.
@jpinckneyltr4505 жыл бұрын
Great video. But what if you want to see running from the drive. I have been trying to find how to program ladder so you can see drive running? Thanks
@MamadAbedi9 жыл бұрын
Thank you man, look forward to see more videos from you. :)
@PLCAutomationTraining9 жыл бұрын
Thank you for watching
@wtar84693 жыл бұрын
Help, please. How can upload the parameters from one powerflex 500 was faulted to a new powerflex 500. Because is to many parameters on the application, i would like to know if is it possible to download the parameters directly from the plc to VFD. Thanks
@kacemabdallah13685 жыл бұрын
thank you so much,it's very helpful.
@pato19820004 ай бұрын
Can you explain with multi drive on the same program.. how can I control two oh more drives .. because pf525 is always looking for port 0
@guangyaoli621811 ай бұрын
Boss I would like to ask. You have two internet cards with different ip address. So which ip address is your computer setting match to? Thank you very much
@openbooktips4 жыл бұрын
Best video i've seen on this topic. Thank you. New subscriber.
@malcolmandthebends29142 жыл бұрын
Thank you Sir
@guangyaoli621811 ай бұрын
Boss. I would like to ass one question. You have two ethernet cards in plc. In this situation data cable from pc should plug in which card? And which ip address should be match in pc ip address setting? Thank you very much and look forward for you respond!
@PLCAutomationTraining10 ай бұрын
We're you able to figure it out? Sorry was away on business and was not online
@jasonwilson91178 жыл бұрын
Thanks. Great video.
@robertonogueira98745 жыл бұрын
1- Which version of 5000 we may use the Discover Modules resource? 2- Are you sure that AOP (add on profile) is useful for Rslinx?? (Thanks for share your knownledge. Regards from Brazil)
@viraguen8 жыл бұрын
Thanks for the video. Can I use RSLogix 5000 Mini or Lite to configure VFD like this?
@petedazer25567 жыл бұрын
Well done!
@sagi11078810 жыл бұрын
very useful video .....thanks sir
@PLCAutomationTraining10 жыл бұрын
Thank you and your welcome
@jinblade4 жыл бұрын
Keep getting module not configured. Any suggestions
@ceilingwalker16 жыл бұрын
Very nice. Thank you.
@jonathansegura57029 жыл бұрын
thanks, thanks, thanks sr., muchas gracias.
@Saurabh_Gambhir3 жыл бұрын
Please make video on adding AENTR module and LIO module and E3 MODULE used for small pumps in rs logix 5000
@nirajbegani41156 жыл бұрын
Is there same settings for poweflex 753
@johnrece66223 жыл бұрын
When you download online I thought the processor will switch to program mode?
@veoteveo16 жыл бұрын
could you do a vid using tags in the AB controller to program logic in intouch.
@Nicofish2023Ай бұрын
Hello please can you do more videos on powerflex 525 how to manipulate all the parameters
@necofme4 жыл бұрын
video is ok, very easy .! but need to add that for the Speed control, need it a jump in the control pin 11 to 1. to model 525 over 5hp
@rahulrpatil30055 жыл бұрын
Thanks a lot man , really helpfull .
@ivanritchie51199 жыл бұрын
thanks for the video man, very helpfull
@soemin48475 жыл бұрын
Thank you very helpful
@petrbrezik16069 жыл бұрын
Hello, please could you give here some description of input and output signals, or a reference to a document where these signals are described. Thanks sir
@PLCAutomationTraining9 жыл бұрын
Could you explain exactly what you want and I will send you the info you are requesting. Thanks for the view
@MrFK27 жыл бұрын
Can I follow the same procedure if I'm using a Powerflex 40 instead?
@PLCAutomationTraining7 жыл бұрын
MrFK2 I haven't tried a powerflex 40 in this situation
@badenkey8 жыл бұрын
Great Tutorial, Thanks a lot
@RaulHerrera-nw9qr Жыл бұрын
what if one is using an older version of rslogix 5000 and doesnt have module discovery ?
@PLCAutomationTraining10 ай бұрын
You can manually add it
@darthenx25858 жыл бұрын
Great video! Do you have a video or can you show how to read the output current from the drive. For example what logic instruction do you need to use to read it.
@PLCAutomationTraining8 жыл бұрын
in the configuration screen where the match drive is in the upper right corner you can add the current. I'll add it to a quick video for you
@PLCAutomationTraining8 жыл бұрын
Here is your link kzbin.info/www/bejne/p3TbhWefnJKmo8U
@Pyrtas6 жыл бұрын
Now you have a "Race condition" between STOP and START signal over Ethernet. It's better wait to remove stop signal and then execute start cmd.
@Jackgitz237 жыл бұрын
Thank you for this awesome video. Quite clear and to the point. Question: How different is the PowerFlex 753 setup from the 525 as you show here? Do you have any vidoes for that? Thanks!
@PLCAutomationTraining7 жыл бұрын
Jackgitz23 the 755 is different. though has many similarities. the hardest part with the 755 was getting the IP address setup.
@mattgallagher71058 жыл бұрын
Thanks for the video. Why is Pump_1:0 Start used instead of the input? Is it because the VFD will start outputting power to the pump motor?
@PLCAutomationTraining8 жыл бұрын
Matt Gallagher please rephrase your question im a little confused
@mattgallagher71058 жыл бұрын
Sorry - I meant in the ladder logic portion, you used a PB start to activate "Pump_1:0 Start". I was wondering the difference between this tag and "Pump_1:I". At about 11:05 you said "we don't want the input, we want the output".
@PLCAutomationTraining8 жыл бұрын
Matt Gallagher because the inputs are what you are reading from the drive and the outputs are what you are writing to the drve, sorry for the late response.
@viniciusspaceandlife73884 жыл бұрын
Thanks for the tutorial! Could you please explain why did you created a automation network with a network module and other private one with the other card? Is it mandatory to use drivers on private networks or it was just made for your network topology and project only?
@PLCAutomationTraining4 жыл бұрын
This was just what I usually do for facility installs, this helps keep network congestion down and helps organize networks, there is no real good reason why I do it this way but this is just an example why.
@viniciusspaceandlife73884 жыл бұрын
@@PLCAutomationTraining Thanks a lot for replying me!
@sebastianallende52885 жыл бұрын
Hi, do you have any experience doing the same thing but with CCW software? I am trying to control a 525 using a micro820 PLC, I have both devices in a program in CCW (I can control the PW525 from CCW) but I can not find out how to pull the Powerflex variables into the global variables list.
@FacesintheStone9 жыл бұрын
Thanks a bunch man!
@SafeAndEffectiveTheySaid8 жыл бұрын
nice job!
@PLCAutomationTraining8 жыл бұрын
Adriano Me thank you
@vorapobautomation97605 жыл бұрын
How to setting analog input 0-10 vdc signal fastest response ?
@herb98805 жыл бұрын
Can you show more video about Kinetix servo drive ?
@PLCAutomationTraining5 жыл бұрын
Yes coming up
@guangyaoli621811 ай бұрын
Boss if I have two internet card win plc with different ip address.which ip address I should match in my pc address setting? Thank you very much
@PLCAutomationTraining11 ай бұрын
Doesn't matter if you bridge your connection
@guzmanjimmy38 жыл бұрын
Very cool video could you do some programing with an allenbradley compaqlogix using studio 5000, I would be very happy to see that. thanks
@PLCAutomationTraining8 жыл бұрын
yes I can though they are very simular
@guzmanjimmy38 жыл бұрын
I appreciated thank you
@danielellerington8708 жыл бұрын
hi, awesome video! would this be the same for the powerflex 40 with comm e adaptor?
@PLCAutomationTraining8 жыл бұрын
yes except the speed ref is a different value i believe or the 70 i dont remember
@danielellerington8708 жыл бұрын
Wow, fast response! I've been reading RA literature and the generated tags are different to the 525. I am building a new control panel with 4 powerflex 40 and would rather use ethernet instead of hard wiring them all. I also read about multidrop with 1 comm e card and I assume modbus daisy chain to the rest, but programming seems more indepth. What would you advise? I'm dan Btw from uk
@holdenjames8087 жыл бұрын
Great video. I am having issues with the ramp function though. I have 420 seconds in the drive but it jumps to 60 hz immediately. Also, when I try to adjust speed reference from 60 to anything else it stays at 60. Do these need to be on "velocity" mode? Or is "position" mode okay?
@PLCAutomationTraining7 жыл бұрын
Jordan Vande Brake velocity mode. then check the speed reference parameter in the drive to make sure its setup over ethernet ip
@PLCAutomationTraining7 жыл бұрын
Jordan Vande Brake also make sure min freq hz is at 0 and max is 60 unless you need more
@holdenjames8087 жыл бұрын
thank you very much for the prompt replies. My min and max is 0-60 HZ. It does seem to respond now to my 'freq command' logic. And, seems to accept my accel rate. However, it automatically instantly jumps to 60 HZ and THEN comes back down to the commanded frequency, at the accel rate, entered. I obviously want to send it the start command and have it accel to 60 HZ over 4-7 minutes(starting centrifuge motor).
@holdenjames8087 жыл бұрын
I must have had some other parameters fighting with each other. Reset to factory default and started from scratch adding only what I thought I would need. Seems to be working fine. this was a great video. Huge help. Thank you.
@PLCAutomationTraining7 жыл бұрын
Jordan Vande Brake seperators they use to use powerflex 700, is this a pump to the seperator
@iankerrigan72147 жыл бұрын
great video, can you show me how to start stop powerflex 527 in rs5k using the motion commands
@PLCAutomationTraining7 жыл бұрын
Ian Kerrigan I'll do a motion course soon
@mantrazone8 жыл бұрын
Gracias super el video
@osamafattah1275 жыл бұрын
Thank you
@Padredimitry6 жыл бұрын
Thank you!
@YASHJARIWAL7 жыл бұрын
Really Helpful tutorial. one Situation i am facing. The PF525 drive is already configured and running perfectly fine. now i wanted to monitor the drive parameter when it is currently running. to do that i got online with the PLC and got into the properties of the PF525 from the I/O configuration in RSLogix5000. and from there i clicked on Drive tab but then was getting Error as '"AUTOMATIC CONNECTION FAILED - MISSING DEVICE IN PORT 1 IN OFFLINE DRIVE". So is the Drive Configured incorrectly? and Is there any Solution to the Above Error
@PLCAutomationTraining7 жыл бұрын
YASH JARIWALA i will look this up i havent ran into this one can you send me a pdf of the drive parameters from ccw
@YASHJARIWAL7 жыл бұрын
i dont have a saved CCW file. its been somehow deleted. i can send you the PDF of the Problem which i am facing so that you can have a better idea of it.
@YASHJARIWAL7 жыл бұрын
Can you provide me a mail id to which I can send you the PDF ?
@ricardordzbenavente63837 жыл бұрын
Great!!!
@cuongngovan818 жыл бұрын
Good Video,
@RobManVids6 жыл бұрын
Thank you for your very informative videos. I'm a little confused as to why you were going to show us the old school way of adding a drive to the tree and then you did a match drive. Matching the drive isn't really old school is it? There is a lot more that can be added manually right?
@PLCAutomationTraining3 жыл бұрын
Yes I'm not sure what I was thinking back then sorry
@husainsaifuddin21017 жыл бұрын
do you do training?
@controld3339 жыл бұрын
Very informative, good clear exemplified presentation. I like the simplicity of the complex intelligence of this drive. By the way I have a question, what is the Ethernet switch you recommend when connecting several drives? to aim reliability but keeping in mind my stinging budget.
@PLCAutomationTraining9 жыл бұрын
hirschman switches are the best in my opinion.
@controld3339 жыл бұрын
PLC Automation Training Thanks alot for the recommendation, I will look into it.
@miguelangelcastrosanchez31348 жыл бұрын
hi, mi name is miguel, I electronic ingeenire, and your video is very nice, but i need the Softlogix 5800 v16, you know any page or link where i can download de software? please!
@manexemano74287 жыл бұрын
Hi! I have installed five (5) pf525 in my system. I always experience this F073 faults, can you please help me resolve this. 3 of pf525 was programmed in ml1100 and the other two was in the ml1500 both in rslogix 500. hope you can help me.
@PLCAutomationTraining7 жыл бұрын
Manex Emano is it all of them?
@manexemano74287 жыл бұрын
wow! thank you for the response! yes! all of them. I noticed that if I run ccw and get connected online of the 5 pf525, that annoying fault will be gone. but no one needs to get their lappy hook up in the network just to get rid of that fault, right? can you please help me because I know I missed lots of things here. I just recently changed my system, by the way. It was actually designed separately (the cip station [ml100] and the process station [ml1500] ) but since my boss gave me another requirements and tasks that the systems should be connected all in the ethernet for much easier (not actually) data and command exchange. I already made a rung that will make the command logic clear faults always on so that it will clear immediately the fault. --- will this help or i just made it worse?
@PLCAutomationTraining7 жыл бұрын
Manex Emano I would check your message times if you want to send me the rss I could look at it for you. Coldbluemountainapps@gmail.com
@viniciusperetti17248 жыл бұрын
hey man, how can i get the status of the ethernet connection ? Sorry by my English, I am from Brazil.
@PLCAutomationTraining8 жыл бұрын
Vinicius Peretti GSV instruction attribute entrystatus then compare the destination status using an MEQ for ethernet
@PLCAutomationTraining8 жыл бұрын
Vinicius Peretti mask equals
@AhmedAboudGP8 жыл бұрын
Thanks
@edsoncavazos46896 жыл бұрын
thx bro!
@jeyaprakash85608 жыл бұрын
use full video super
@goranhikl57239 ай бұрын
Great video if you can download. what if you can't
@webmarvels67432 жыл бұрын
Helpful, but watching people write code is mind-numbing - I'd recommend prepare that and just talk to it briefly.
@PLCAutomationTraining10 ай бұрын
I agree but sometimes that numbing removes extra questions plus sometimes people use short cuts and it's nice to learn myself
@kezzibaba8 жыл бұрын
Hey can you please create a ADD ON INSTRUCTION TUTORIAL ? I WILL REALLY APPRECIATE IT.
@PLCAutomationTraining8 жыл бұрын
what type of add on would you like to see?
@kezzibaba8 жыл бұрын
+PLC Automation Training preferable i will like to see AIO that involves data transfer. Don't quite understand how to explain it but i will like to see you dosomething more advance using AIO if that makes sense. Thanks.
@scorepion5336 жыл бұрын
Please any one can help me to control this vfd (start/stop and speed setpoint) in Automode using ethernet ip and manual mode using push buttons. I have switch manual-off-auto THANK YOU.
@PLCAutomationTraining6 жыл бұрын
Send me your program
@scorepion5336 жыл бұрын
@@PLCAutomationTrainingyour email plz
@Nicofish2023 Жыл бұрын
How to contact you ?
@PLCAutomationTraining10 ай бұрын
What do you need help with
@Nicofish202310 ай бұрын
@@PLCAutomationTrainingi need training on VFD
@PLCAutomationTraining10 жыл бұрын
@kayserkayser86854 жыл бұрын
Porfa traducelo al español
@PLCAutomationTraining4 жыл бұрын
If i could speak fluent i would
@disun41525 жыл бұрын
Amazing tutorial video. I was much impressed by the clear English voice and good knowledge. I have subscribed the author videos already. The first time I have ever subscribed a you tube author. I will be watching more on this Author's other videos. I am interested in Siemens stuff as well