@johnblouch3309
@johnblouch3309 11 ай бұрын
I will be installing a Power Vent Water Heater soon. Your video gave me the confidence to make it happen. I am still reading through the instruction manual. If I may ask a question. Is there a reason I should install 3 inch verses a 2 inch PVC vent pipe? Why the choice? I am probably over thinking it. Thank you for the awesome video.
@MiHeatingGuy
@MiHeatingGuy 11 ай бұрын
Good luck!
@Victor-vp7kn
@Victor-vp7kn 2 жыл бұрын
Thank you for the video. Will a power vent water heater help getting hot water faster to the shower?
@MiHeatingGuy
@MiHeatingGuy 2 жыл бұрын
No
@buckruttin2246
@buckruttin2246 Жыл бұрын
There is a recirculating valve on the market that brings hot water to to the fixture and carries cold back to the tank. Don't remember the brand but I r&r'd one on a bathroom sink during a remodel.
@jonwikan3986
@jonwikan3986 9 ай бұрын
MI Heating guy! Nice video! I have a sediment trap question. My Power vent just failed on me, so I acquired an unit that was nearly the same 100K btu. Also the same Brand as you have here (State, AO Smit etc...) The slight difference for me on the new unit, is the gas enters on the top of the tank and is threaded 1/2 npt into the top of the gas gas control valve instead of entering the side. How do you do the post valve Sediment trap? Obviously I can come out and elbow to vertical but must the pre shut off valve sediment trap be a certain distance from where it enters the heater? Reason being my gas enters opposite side of the tank and I have to get over the blower unit and hot and cold water supply lines. I guess I am asking, for space sake if I can run my black pipe for several feet out of the unit before putting my valve and sediment trap?
@MiHeatingGuy
@MiHeatingGuy 9 ай бұрын
Just come off the new valve with a short nipple and a tee. Put your trap right at the bottom of the tee. Then connect your gas to the top of the tee
@tmacgee1234
@tmacgee1234 4 жыл бұрын
Glad to hear I'm not the only hvac guy doing mad water heaters lately
@malikothman5381
@malikothman5381 Жыл бұрын
I don’t know how you moved the heater by your self it’s over 170 pounds and you’re not a big dude .. I’m trying to take one down to the basement with my son and we are struggling
@acmm50
@acmm50 2 жыл бұрын
Just had my BW 50G power vent replaced with a Rheem not my first choice but it was available. You are one of the best plumbers I have watched on YT for sure
@garycooper4524
@garycooper4524 4 жыл бұрын
Looks like ‘M’ copper tubing used with red stripe. Some codes don’t permit use on domestic water systems.
@zeroheat5787
@zeroheat5787 4 жыл бұрын
Good eye, Sir. Didn’t read your comment before I posted. At least someone else caught this.
@matthewbeddow3278
@matthewbeddow3278 3 жыл бұрын
Great to watch a true professional working his trade. I worked in automotive coatings for a very long time & we had a plumber that covered the 5 sites we had, I worked on the technical side and also drew up plans for modifications and any new plants. I always included him in any design meetings & I learned a lot from him, I know if he was watching you he'd say this guy knows his stuff. Unfortunately, he died of cancer many years ago before u tube & the computer age. Thanks for the video.
@Budgetbuilds449
@Budgetbuilds449 2 жыл бұрын
May I ask what the hole with the pipes going in it is for jeez so much pipes and wires not a job for me I love to fix things but that’s just not for me
@tomm5898
@tomm5898 3 жыл бұрын
I was hoping this video was gives some advice about getting a power vent water heater or not?
@roystonpaulmckenzie3878
@roystonpaulmckenzie3878 3 жыл бұрын
Can you hooked up a power vent to an existing regular vent system
@Bob.W.
@Bob.W. 4 жыл бұрын
Nice working area, for a change. Thx.
@TheWatergas
@TheWatergas 2 жыл бұрын
Do you recommend on running a drain line from the vent pipe?
@bangzoom8180
@bangzoom8180 3 жыл бұрын
My power vent runs intermittently...runs for 10 seconds then shuts off...repeats multiple times. Water doesn't heat. Is there a sensor in the vent motor? Capacitor?
@MiHeatingGuy
@MiHeatingGuy 3 жыл бұрын
Could be a pressure switch or a faulty gas control. Maybe something in you venting. Does the gas control flash any codes
@bangzoom8180
@bangzoom8180 3 жыл бұрын
@@MiHeatingGuy Code flashing 3x...TCO or pressure switch failed open
@brendand1325
@brendand1325 3 жыл бұрын
What a jumble of cords, water treatment tanks, sump pump, electric cords, hoses, etc. How could you figure all of that out
@metrotechguru5863
@metrotechguru5863 4 жыл бұрын
Your pipe fitting skills are phenomenal. Every job looks attractive and professionally done. Cudos to you.
@kevinpoore5626
@kevinpoore5626 4 жыл бұрын
Yes I do believe the large group of people do you think a plumber it's just a plumber then there are some who strive for the best and our Artisans of their trade like I stride to be lol :-) :-)
@r1ashad
@r1ashad 3 жыл бұрын
Im just curious. Why did you cut all the plumbing instead of disconnecting all the union or hose clamps?
@joemartinez7765
@joemartinez7765 3 жыл бұрын
Thank dear sir. It's always a learning experience with your videos. Really enjoy your tech trouble shooting videos.
@rogerlague1520
@rogerlague1520 4 жыл бұрын
Is it okay in your professional opinion to crimp fittings to dirty pipes
@josephlowman7906
@josephlowman7906 4 жыл бұрын
No
@JBGecko13yt
@JBGecko13yt 3 жыл бұрын
those power tools are awesome!!!! the cutter? Never seen one till today.
@kevinpoore5626
@kevinpoore5626 4 жыл бұрын
Yay water heaters aren't they just loads of fun lol :-) :-) have a happy New Year man
@thankswillie
@thankswillie 4 жыл бұрын
50 gallon bradford w/power vent,where to buy and how much
@WilliamJoseph2015
@WilliamJoseph2015 4 жыл бұрын
He has all the toys. I want to do more of these jobs. Time for another rental
@brendand1325
@brendand1325 3 жыл бұрын
Y0ou must be a sick man--you want more rental problems to solve !
@WilliamJoseph2015
@WilliamJoseph2015 3 жыл бұрын
@@brendand1325 lol
@robertjacobs2721
@robertjacobs2721 2 жыл бұрын
I Hate to sound like a hater, but the soldering skills were not correct. You should always take apart the plastic parts to the union and solder it away from the heater. The flame needs to be in the area you want the solder to travel , not away from it. As you cool it place back the fittings and reassemble the pipe and never re-flux a finished solder joint. Just lightly wipe with dry cloth then cool with water or wet rag. BTW, it wouldn't hurt to bleed the air out the gas line before you start up the heater so the ignition won't lock out... Just a friendly tip.
@matthewfasullo4983
@matthewfasullo4983 4 жыл бұрын
I do them everyday all day that's my job. You should look into getting the pvc cutter that Milwaukee has makes some nice cuts when it comes to venting
@AnthonyAlfaro22
@AnthonyAlfaro22 3 жыл бұрын
I have a question. I am about to replace and install new for a home owner. What should I charge for this installation. I sweat all my copper. He wants to know what I will charge him? I’m not a licensed contractor but I’ve been in the business for 18 years and I do my research and I’m thorough. Any idea of cost. I’m trying to help the guy out, a friend through a friend deal. Already been dealing with it since last Friday which is almost a week. Honeywell gas valve gave off code# 3. TCO or pressure switch failed open. I replaced both pressure switches on the power vent and still nothing. They told me it was probably the hi limit snap disc under the pressure switch. I am replacing that and the gas valve on Friday. That will make it 7 days of research and calling the manufacturer and 6 different plumbing houses with no luck finding parts. Haven’t charge a penny yet because I haven’t fixed the problem. I’m just not good at estimating cost for my time if anybody could help me I would greatly appreciate it I don’t wanna overcharge but I definitely don’t want to under charge. Thanks
@matthewfasullo4983
@matthewfasullo4983 3 жыл бұрын
@@AnthonyAlfaro22 can you send me a pic of the gas valve and front of the burner assembly. There may be a tco switch on the burner assembly that is old. If you put a new one in that may be the issue. Now I've come across that same issue where I replace the switch and the gas valve stem is defective so gas valve has to be replaced
@metatechnologist
@metatechnologist 3 жыл бұрын
What is the lifetime of these powervent water heaters??
@no.1Swiftie4Trump
@no.1Swiftie4Trump 3 жыл бұрын
Funny you should ask. I just discovered 2 days ago that the life span can be as short as 5 1/2 years
@thankswillie
@thankswillie 3 жыл бұрын
i put in the same one in 2007,,,,well almost the same they now have different features and different gas valve....i have hard water(no softenner)....IT HAS NEVER SKIPPED A BEAT...
@waltradcliffe4482
@waltradcliffe4482 4 жыл бұрын
No need to explain yourself just keep doing what works for you the haters are going to hate anyway
@jackblack9830
@jackblack9830 4 жыл бұрын
100%
@winkhvac62
@winkhvac62 4 жыл бұрын
Cool man keep them coming!!
@JCT442
@JCT442 4 жыл бұрын
The question is; are you a better plumber or HVAC tech? How about outstanding at both!
@brendand1325
@brendand1325 3 жыл бұрын
What's a plumber ? In southern Calif. I call the plumber, pay high plumber rates, and a person comes to do the job--not a plumber--and almost always I get a half-assed job. No plumber license is required to do plumbing--a plumber (licensed) owns the business and sends out guys who have incentives to make extra money over their hourly pay. A plumbing license here is a path to a big income.
@brendand1325
@brendand1325 3 жыл бұрын
Same with HVAC apprentices, they call them. But no bonus for them for installation and service as far as I know. No license. The man with the license is in the office--or making bank deposits.
@jackblack9830
@jackblack9830 4 жыл бұрын
I agree with you on both soldier and the unions I think its a better job myself with the unions Nice Job Sir Had me searching I thought I missed something glad to see the vids back.
@davidunderwood4341
@davidunderwood4341 2 жыл бұрын
I solder the unions without the plastic or top nut close to the solder joint. I agree though, if you've been doing it without problems for years, then you clearly know what works. Since I'm not as advanced, it would be scorched earth around those unions if I did it your way! Haha!
@mainelyelectric
@mainelyelectric 3 жыл бұрын
Are these tank style power vent water heaters worth it? Are they loud when running? Would they be good for a rental that I want to change the tank water heater from a shared chimney to it’s own vent and I only have one chimney for the oil furnace.
@timothyfink9354
@timothyfink9354 4 жыл бұрын
thanks for the vid.
@onemanarmy6073
@onemanarmy6073 4 жыл бұрын
I can’t exactly place why ,but I like this guy-miss the helper interaction on this one though
@steventate7713
@steventate7713 3 жыл бұрын
Dad are you teaching us something or talking to yourself and criticizing let us know
@bigcat.mattyahoo
@bigcat.mattyahoo 4 жыл бұрын
So plugged drain at bottom is that just 3/4 npt nipple than 3/4 ball to flush bigcatmatt purple power by the way solder where ever the f}%%^^u want too love videos keep them coming longer the better
@alexg3855
@alexg3855 4 жыл бұрын
Does MI allow HVAC contractors to install water heaters? Or are you doing the work under the company’s plumbing license?
@BeautifulAngelBlossom
@BeautifulAngelBlossom 4 жыл бұрын
A home owner can install water heater if she or he wanted too
@alexg3855
@alexg3855 4 жыл бұрын
@@BeautifulAngelBlossom my state (Massachusetts) allows homeowners to do any work on their home as long as it meets code. But if a contractor comes in to do the work it has to be permitted and inspected, so I was just curious if it was different. Like I install water heaters under the company’s plumbing license, but am not a licensed plumber.
@BeautifulAngelBlossom
@BeautifulAngelBlossom 4 жыл бұрын
@@alexg3855 My State of Illinois or my county You can do anything in your home with permit .you can do stuff outside without a permit too but you cannot put an addition to your house without a permit you can put a deck in without a permit from what I was told and after you do work inside of your house they don't send an inspector in my house is over 100 years old so there's not a lot of things up to cold in this house because you couldn't really have things up to code in this sort of a house . like we have PVC water line and I think that's okay and we did our DIY hot water heater installation we got a Rheem from the Home Depot I even DIY my air conditioner unit too it was to clean it replace the capacitor and a burnt wire a lot of people just don't want to touch that unit because it's from 1994 and it's a rudd and it's R22
@brendand1325
@brendand1325 3 жыл бұрын
@@BeautifulAngelBlossom You ever hear of punctuation? I needed some periods in your post to try to comprehend it. Just saying. I gave up on the third line.
@WswRefrigeration
@WswRefrigeration 4 жыл бұрын
KZbin police is what they’re called
@BeautifulAngelBlossom
@BeautifulAngelBlossom 4 жыл бұрын
Yup
@jackblack9830
@jackblack9830 4 жыл бұрын
Monday morning quarterbacks I was one once to though My only real fear was Whats said on video and off video sometimes. CYA these days Love the vids
@JBGecko13yt
@JBGecko13yt 3 жыл бұрын
if the junctions were not meant to be soldered they would have a warning lol. don't listen to the Armchair experts.
@RandomDude989
@RandomDude989 4 жыл бұрын
So the fact that my water from 1996 still works just fine is unusual from what I've been seeing on these videos.... Or I just got a good one. Lol.
@jackblack9830
@jackblack9830 4 жыл бұрын
Be careful with that comments I had a battery in my van it was 14 years old well I had to brag one day at coffee time with the guys how great interstate batteries are the original battery in my van 14 years and still going like a champ Well wouldn't you know the next dam morning click click Mutha son of a Had to get a jump and go buy a new F ing battery LOL what could I do but laugh and of course that days coffee time was all about me and my interstate LOL when you said that I just had a flash back And figured. SHHHH lol 😆
@RandomDude989
@RandomDude989 4 жыл бұрын
@@jackblack9830 I plan on replacing it this spring/summer. Its electric and the treads for the heating elements are about wore out because I remove the bottom one and suck out all the junk from the hard water I have once a year and replace the elements at that time too.
@jackblack9830
@jackblack9830 4 жыл бұрын
@@RandomDude989 you sure can't complain about that one definetly got your moneys worth What brand is it. I just hope your luck don't happen like mine did lol To be fair though I had a power inverter in the van and I think I left something plugged in and it was winter Good luck 👍 🙏🙏 come on 2021 and spring weather
@throttlebottle5906
@throttlebottle5906 4 жыл бұрын
that water heater didn't look that old, by far!. maybe it's just my eyes and recollection lol
@MiHeatingGuy
@MiHeatingGuy 4 жыл бұрын
10 years old
@throttlebottle5906
@throttlebottle5906 4 жыл бұрын
@@MiHeatingGuy older than it looked!
@RaceDude57
@RaceDude57 4 жыл бұрын
A water heater a day keeps the doctor away...
@rogerlague1520
@rogerlague1520 4 жыл бұрын
Half inch pipe = 1/2 " solder. Three quarter inch pipe needs 3/4" solder too reach the bottom of the fittings and so on. Even more solder at 2"
@zeroheat5787
@zeroheat5787 4 жыл бұрын
Everyone who has complimented the great work probably didn’t notice that you used Type M on domestic water. I can add to the list of mistakes if you want. Just ask. Probably will get ignored like my other comment on a previous video I stumbled upon.
@jackblack9830
@jackblack9830 4 жыл бұрын
I've had to use it a few times myself shit happens And ya know its been years and not a problem Don't hate
@zeroheat5787
@zeroheat5787 4 жыл бұрын
@@jackblack9830 probably has been a few years since you’ve gotten a call back to those places where you installed M on domestic. It’s not hating; it’s doing the right thing. Suppose I put S rated tires on your SRT10.... you’d say something wouldn’t you? It just doesn’t belong.
@jackblack9830
@jackblack9830 4 жыл бұрын
@@zeroheat5787 Well I do not advertise I am solely repeat customers And have been for many years. I agree with you But Some times you gotta do what you gotta do. You can either wait until supply house has it or i can use what I have and it will work perfectly fine Its just a thinner wall pipe its still supplying hot water to their faucets Is it ideal no but will it work absolutely Will it last yes
@zeroheat5787
@zeroheat5787 4 жыл бұрын
@@jackblack9830 there were many times that I wished I didn’t know the difference between right and wrong because I’d have completed the service call easily; but I chose to do the right thing: to code. It’s a water heater replacement; he was at the vendor because he picked up a new heater. He could have purchased Type L, or went looking. He’s not in the boonies. He didn’t need dielectric unions but chose to install them. Why do the “right “ thing but completely fail on another. He didn’t ream the pipe either. Fluxed a soldered joint, etc. I didn’t bother finishing the video after I saw the Type M pipe. I went straight to comments and called BS. It baffles me how he works for someone and posts this garbage. I wonder if his employer sees this. There’s professionals who do not accept work like this. I’m one of them. I understand your point; you want to get the job done. You work for yourself and have no one to answer to. He represents someone; not for himself. Just take what I’m saying into consideration.
@jackblack9830
@jackblack9830 4 жыл бұрын
@@zeroheat5787 Its always best to do it right Agreed 👍 But I own a house many of them but one that when I installed all the new plumbing supply lines I was a young guy 30 years ago Went and grabbed all the supplies did not notice M Did the whole house moved on to the other work in the house and one day happened to notice 😳 WTF I said to myself well its all in now so I know I'll be making changes down the road but for now its nit like u can return the shit WTF and like I said young guy so money wasnt easy back then SO I just finished the house up Got it rented its been rented all these years and I have yet to have a problem with any of the plumbing I should not have said that .... But after 30 35 years now its not bad Would I recomend it absolutely not but when you look in your truck and see you have 3/4 pipe on the shelf You have their water off and realize its not L Its M It will work To be fair Back in the day I was used to my father buying the supplies I did the labor So when he passed and I took over I was just grabbing 3/4 pipe Git r dun madness Thats how that mistake happened but its been good so far. And now if it gets changed it will have to be pex due to the area and high volume scrap cruds around there I hate that fact I am a copper and cast guy I hate the plastic world But Scrapers force the issue.. Not a lot of guys left that can do cast Sad 😥 but the world we live in I guess. I agree with you. Dont get me wrong I did notice that and not reaming and all But all in all he does have good content I like his videos I like him and his work No one is perfect always And sometimes its just a Needabee
@matthewfasullo4983
@matthewfasullo4983 4 жыл бұрын
Nvm I see you have it lol where are your safety goggles that stuff shatters you know
@throttlebottle5906
@throttlebottle5906 4 жыл бұрын
well aged and cold weather it does tend to shatter into bits explosively! only the old school "new construction" guys know that, as well as we can tell "rim solder joints" it all works great, until it doesn't :))
@rogerlague1520
@rogerlague1520 4 жыл бұрын
I would like to see one of those quick soldier joints and soft washes when you are done, fast isn't always better. That's not the right amount of solder to make it to the bottom of the fittings.
@JasonMMoreno
@JasonMMoreno 4 жыл бұрын
thats bull shit that you skipped over taking that maintenance valve off and the mess that ensued.
@johnblouch3309
@johnblouch3309 11 ай бұрын
I will be installing a Power Vent Water Heater soon. Your video gave me the confidence to make it happen. I am still reading through the instruction manual. If I may ask a question. Is there a reason I should install 3 inch verses a 2 inch PVC vent pipe? Why the choice? I am probably over thinking it. Thank you for the awesome video.
@MiHeatingGuy
@MiHeatingGuy 11 ай бұрын
Most applications are 2-in depending on the length of the vent run. Thanks for watching
water heater leaking at water connections
19:43
steven lavimoniere
Рет қаралды 138 М.
Extremely Dangerous - Water Heater CONVERTED to a Power Vented - DON'T TRY THIS AT HOME!
21:36
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 67 М.
When you have a very capricious child 😂😘👍
00:16
Like Asiya
Рет қаралды 18 МЛН
Леон киллер и Оля Полякова 😹
00:42
Канал Смеха
Рет қаралды 4,7 МЛН
This Heater Can Save Lives During Power Outages!
19:48
Project Farm
Рет қаралды 817 М.
Water Heater Vent Pipe Inspection Failure and Fix
18:06
KenTraining
Рет қаралды 87 М.
30 Minute Secret Makes Your Water Heater Last Decades
13:03
LRN2DIY
Рет қаралды 2,4 МЛН
How does a tankless gas water heater work?
9:21
Sanya Tsvay
Рет қаралды 933 М.
Quick Water Heater Swap
16:13
Michigan Heating Guy
Рет қаралды 2,4 М.
How To Replace a Water Heater (Power Vented Natural Gas Heater)
9:11
waste oil heating stove mini 3 in 1 ! Millions of people do not know this knowledge
15:19
Creative inventions LMTN
Рет қаралды 3,6 МЛН
Aquastat Repair
11:22
budget Brian repair
Рет қаралды 14 М.