Water Heater Vent Pipe Inspection Failure and Fix

  Рет қаралды 85,767

KenTraining

KenTraining

Күн бұрын

Пікірлер: 100
@mayboo9368
@mayboo9368 10 ай бұрын
my guy you were so awesome explaining this to me, this really helped my inner understanding, of the vent connector. Im going to be great out here.
@davidshettlesworth1442
@davidshettlesworth1442 Жыл бұрын
Wow! Those are some big No-No's on that vent pipe. Thank you for an excellent video.
@micaht52
@micaht52 10 ай бұрын
You answered so many questions, thank you! Had a furnace retrofitted and they tried to put negative fall on the vent, theres actually not a way to vent the furance thats code compliant.
@j.me.0311
@j.me.0311 Жыл бұрын
Looks like you put a bit of time into this video. Thank you!
@jamesgreenblat1778
@jamesgreenblat1778 Жыл бұрын
I don’t know your location but here in San Francisco, California I believe you should have type B from the water heater going to a B vent T. Then the riser B vent above roofline. The T is to prevent condensation and also you have a standing pilot in case there’s a backdraft the pilot won’t go out. With the standing pilot we are required to be 18” above ground level in a garage area. Otherwise you accomplished the task very well. I’m a 3rd generation residential sheet metal craftsman.
@KenTraining
@KenTraining Жыл бұрын
this water heater is 18" above ground and yes the jo b should have B vent going through ceiling and roof. I have not changed out yet but I should. I want to learn more about the T you mentioned. Is there a video link on one installed you can share with me?
@hughheckler
@hughheckler 4 ай бұрын
Definitely an improvement, I'd keep a co2 detector in that room. Good work overall, just doing what you've got to do!
@yana-tm1ph
@yana-tm1ph Жыл бұрын
I just want to thank you for your information, removed the insulation around the vent and the furnace it now shorting at 9 minutes. I assume I need to empty the rest of dirt off the burner, even if has been a couple of weeks since it has been cleaned. The water hose vent was back drafting. Not I need to check my other new furnace why it is short-cyrcling. I have learned so much from your website about vents.
@Jose-io4nk
@Jose-io4nk 9 ай бұрын
Thanks so much I didn't know about this books code
@badmatt4227
@badmatt4227 2 жыл бұрын
Thanks for sharing the codes.
@akjwHTX
@akjwHTX 2 жыл бұрын
You the man Ken, never thought of this
@edlu6995
@edlu6995 Жыл бұрын
Great help. Thanks a lot. Keep posting.
@redsresearch
@redsresearch 10 ай бұрын
how do you air seal and insulate that going thro the ceiling into the attic?
@lohe
@lohe 10 ай бұрын
Great video answered the questions I had.
@fidelsseecoomar3279
@fidelsseecoomar3279 Жыл бұрын
Why did you use the old single wall type c pipe if it's not to code 🤔
@normalhuman9260
@normalhuman9260 2 жыл бұрын
Missed it by that 👌 much. Very useful video,thank you.
@lifecoachpoul8466
@lifecoachpoul8466 4 ай бұрын
Your vent pipe looks like it is installed correctly to me. Male at the lower end and female on the upper end. You describe it like it is not that way but the video clearly shows it that way.
@KenTraining
@KenTraining 4 ай бұрын
a proper install is female on lower end and male on upper end.
@russellstall169
@russellstall169 Жыл бұрын
Ken my vent pipe is running thru a big hole in my ceiling with nothing to seal up the hole around it, what can I do? I’m looking for a product to seal the hole- something like the metal sheet on your ceiling by the heater- what should I look for?
@KenTraining
@KenTraining Жыл бұрын
you can make one by buying a sheet of sheet metal and cutting the hole out with tin snips. I don't know if you can buy pre cut.
@russellstall169
@russellstall169 Жыл бұрын
@@KenTraining easy enough, think I will do just this. Thanks!
@brianmoore5498
@brianmoore5498 2 жыл бұрын
No ninety right out of the vent hood. Go up vertically with four inch at least 12 inches before using a ninety
@larrytheplumber9851
@larrytheplumber9851 2 жыл бұрын
Hood drift
@JBTran-p7j
@JBTran-p7j 6 ай бұрын
Good morning Mr.Ken I would like to ask you a question about the metal vent pipe for the water heater: why does water drip on where two pipes connected. I appreciate
@KenTraining
@KenTraining 6 ай бұрын
I want to answer you but I don't understand. are your referring to my video or your house?
@JBTran-p7j
@JBTran-p7j 6 ай бұрын
@@KenTraining about my house, please.
@KenTraining
@KenTraining 6 ай бұрын
@@JBTran-p7j I need to understand "where the 2 pipes connect" what is that location? I need a better description.
@JBTran-p7j
@JBTran-p7j 6 ай бұрын
@@KenTraining So from the water heater tank up to 3 feet using an elbow installed, then from the elbow and 5 feet long connecting to 6 feet long (total 30 feet through the outside backyard), so between 5 feet and the pipes connected, water drips/ leaks. Is it possible for me to use anything to seal those two pipes? Thanks
@KenTraining
@KenTraining 6 ай бұрын
@@JBTran-p7j is the water coming from the flue gases condensing? Can you take an infrared thermometer and note the temperature of the flue pipe upon exit of the water heater and then at the midway point and then at the roof exit. I assume your are running natural gas for the fuel but please confirm this is true.
@078dragonlady
@078dragonlady 2 жыл бұрын
Wow.. Well you got plenty of work cut out for you.. Looks like a nightmare for me.. I was thinking of changing my electric water heater to gas.. I may reconsider
@tygoulding2547
@tygoulding2547 Жыл бұрын
Keep electric. Way more simple. Easier to fix, and can’t kill you with carbon monoxide
@jjtaylor5687
@jjtaylor5687 2 жыл бұрын
Get a licensed plumber for gas work
@nickgill418
@nickgill418 2 жыл бұрын
Hello Ken on your video we need a set of the two plates you have secured around the vent pipe as it leaves the room and up and through the ceiling. What are those plates called so we can try to find them for sale? And how did you attach them to the drywall ceiling? Thanks.
@KenTraining
@KenTraining 2 жыл бұрын
it is a home made fire block, made out of sheet metal. the drywall is cut to provide a 6" gap around the pipe and then the sheet metal extends past that and its just secured to the drywall. If you use type B vent through the ceiling which my house should have but the original installer did not, then you will only need a 1 inch gap around the pipe to the drywall.
@comk135
@comk135 2 жыл бұрын
Quick question: the termination height should be less than 5 feet above the gas water heater draft hood--measuring from the top, or the bottom of the draft hood? There're a couple of inches between the top and bottom of the draft hood. Thanks.
@KenTraining
@KenTraining 2 жыл бұрын
my opinion is from the bottom of the draft hood because that is where the draft begins. The top of the draft hood is connected to the vent pipe.
@jeremyking6146
@jeremyking6146 3 ай бұрын
gotta dissagree on the orientation of male/female pipe. it matters alot for wood burning appliances but for gas, the dilution air from the room at the draft collar will cause a Vacuum and the flue gases will find its way out fine.
@KenTraining
@KenTraining 3 ай бұрын
you are probably right that it does not matter as much. But I do think, as long as you are the installer, why not install the right way...
@mts7274
@mts7274 Жыл бұрын
How do you get the screws in pieces with no pre-drilled holes?
@KenTraining
@KenTraining Жыл бұрын
use self tap screws.
@PatrickBuckley-ol2ok
@PatrickBuckley-ol2ok 22 күн бұрын
Do I need a lighter in my chimney for running a gas furnace
@KenTraining
@KenTraining 21 күн бұрын
I am not sure what you mean. Many people vent natural gas appliances using a chimney.
@PatrickBuckley-ol2ok
@PatrickBuckley-ol2ok 19 күн бұрын
@KenTraining liner
@PatrickBuckley-ol2ok
@PatrickBuckley-ol2ok 19 күн бұрын
@KenTraining with gas appliances it is required by code to have a liner because cracks in the mortar is a easy way for carbon monoxide to leak.
@josephlomeo3435
@josephlomeo3435 2 жыл бұрын
Good information.
@keithkeithkeith9874
@keithkeithkeith9874 2 жыл бұрын
How would you patch a pen size hole on a vent pipe? There's a mesh patch on my furnace vent pipe and I wanted to know what type of patch is it. It looks professionally done.
@KenTraining
@KenTraining 2 жыл бұрын
If its only the size of a pen, you can put a metal button in it. check this out hvac-talk.com/vbb/threads/2198672-Hole-in-my-furnace-exhaust-vent-flue-pipe
@keithkeithkeith9874
@keithkeithkeith9874 2 жыл бұрын
@@KenTraining Thank you for time. I'm still wondering where I can get this mesh patch for the hvac system pipe for future repairs to prevent from replacing the whole pipe.
@KenTraining
@KenTraining 2 жыл бұрын
@@keithkeithkeith9874 I don't know, I have never seen or applied a mesh patch to a Vent pipe. It would need to withstand 500F or more...
@vinnygoombatts1458
@vinnygoombatts1458 4 ай бұрын
You can get by if you put metal flashing between vent and existing wood, then I would change it later.
@KenTraining
@KenTraining 4 ай бұрын
That is good practical advice. Thanks
@vinnygoombatts1458
@vinnygoombatts1458 4 ай бұрын
@@KenTraining inspector made us do it one time so I can't take the credit if we have PVC venting running too close to the roof they made us do it too how to put flashing inside the roof above the pipe in case they nailed through
@rodgraff1782
@rodgraff1782 Жыл бұрын
What a cluster F. Single wall thru to the roof. Thee only thing right about this video is your code book. I used to giver those out to my apprentices. Please fix this before you have a fire. It isn’t even close to code, even after your work. It wouldn’t even meet the installation instructions for the water heater. You may have to buy a stubby water heater, and move it, before it can be made safe. Just hire a pro and get it done right.
@dustinfuentes5746
@dustinfuentes5746 4 ай бұрын
Damn dude, hire a plumber. Wtf
@catranger01
@catranger01 2 жыл бұрын
Call the guy that installed it and tell him you want a refund for shoddy work.
@jmabs5096
@jmabs5096 8 ай бұрын
I hope this wasn't a company that installed this, I would sue if that happened to us
@KenTraining
@KenTraining 8 ай бұрын
I don't know, I bought the house this way. But I would not have sued anybody anyway.
@stevehiggins9338
@stevehiggins9338 2 жыл бұрын
Epic fail on your part. You didn't replace the single wall vent pipe going through and within 6 inches of combustible materials and through the roof.
@AidanSkoyles
@AidanSkoyles 2 жыл бұрын
it is done wrong, but in a vent where there's no lint, this seems like nitpicking. in a dryer vent it might be a different story.
@rodgraff1782
@rodgraff1782 Жыл бұрын
Nitpicking? There is not one thing right about it. It’s a fire hazard with single wall too close to combustibles, pipe run backwards, elbow right at draft diverter, and ready to fall off, roof termination not to code, etc, etc, Would you want this in your house?
@SuperAcousticman
@SuperAcousticman Ай бұрын
Also should be 4 inch
@KenTraining
@KenTraining Ай бұрын
I think your right based on my BTU input.
@matthewgodwin6688
@matthewgodwin6688 Жыл бұрын
Had gas water heater malfunction cause was starved for gas cause heater couldn't keep That damage wires and to point one scorched ceiling
@KenTraining
@KenTraining Жыл бұрын
I am glad you were not hurt.
@matthewgodwin6688
@matthewgodwin6688 Жыл бұрын
@@KenTraining yea wish insurance company did give us hazel Want give 800 on 60g bill
@KenTraining
@KenTraining Жыл бұрын
@@matthewgodwin6688 Wow, That is not good insurance, what Insurance co. is that?
@JoeMill-sl9rz
@JoeMill-sl9rz 7 күн бұрын
Surprised you use old beat pipe
@KenTraining
@KenTraining 7 күн бұрын
It still has life left on it...
@njtinman519
@njtinman519 2 жыл бұрын
but you are still a fire hazard through the roof you could just put b vent through the existing roof penetration and get rid of your fire hazard
@KenTraining
@KenTraining 2 жыл бұрын
That is a great point, I will have to take a second look at doing just that. Thanks for reminding me.
@boby115
@boby115 2 жыл бұрын
Keith, you’re absolutely correct. Single wall vent pipe is not allowed to be in an unconditioned space( attic area in this case). Single wall vent pipe is not allowed to leave your eyesight (It’s quite obvious we can’t see it once it penetrates the ceiling). Ken, hopefully the B vent is installed by now , with all the required clearances.
@douglaslewis4201
@douglaslewis4201 3 ай бұрын
Aking code everywhere. 12" minimum rise off of drafthood.
@KenTraining
@KenTraining 3 ай бұрын
your right but I did not have the clearance.
@oldarkie3880
@oldarkie3880 2 ай бұрын
It looks like you need a powered vent water heater
@KenTraining
@KenTraining 2 ай бұрын
That is a true statement. I have studied these water heaters and to meet code and leave in the same spot, I should change to powered. Drawback is 1. cost and 2. availability. I was planning on waiting till 100% failure (leaking) and then change out. the powered water heater would take 1 to 2 weeks if I ordered via Home Depot today. Even though I have a code violation water heater installed at this time, this style water heater has been working for over 40 years in this home in this spot...
@lawnboyfromhell
@lawnboyfromhell 2 жыл бұрын
But you didn't fix it. the roof transition is still single wall!🤔
@KenTraining
@KenTraining 2 жыл бұрын
Your correct, I did not want to change the roof penetration because the roof is very brittle to walk on. the roof material is not manufactured anymore. It has been working good for 20 years. When I change out the roof some day when it fails, I will correct this.
@raulrojas1839
@raulrojas1839 6 ай бұрын
I was under the impression that you can’t have the vent be next to a window die to carbon monoxide poisoning, and if it was it would have to cleared the top of the roof
@KenTraining
@KenTraining 6 ай бұрын
you are correct, there are window clearance requirements. I was not near a window.
@shanecompton2428
@shanecompton2428 Жыл бұрын
Move the water heater dude
@KenTraining
@KenTraining Жыл бұрын
I hear you, I am not sure where yet... No good options and have full use of garage.
@bert1913
@bert1913 3 ай бұрын
Would you eat a carrot for us?
@PatrickBuckley-ol2ok
@PatrickBuckley-ol2ok 22 күн бұрын
Comment
@whatdaheck9667
@whatdaheck9667 Жыл бұрын
just repaired one that has been venting into the attic for 2 years ,with that being said you seam a bit whiney
@gangtian7869
@gangtian7869 2 жыл бұрын
I hope you get a real licensed certified HVAC technician to check your venting system before someone get carbon monoxide positioning. I can still find quite a lot code violations, seriously please find a licensed gas fitter check it out.
@tluva1020
@tluva1020 Жыл бұрын
sMaSh dAt LikE buTToN 🥴
@thomasherceg684
@thomasherceg684 Жыл бұрын
He says its HIS OWN HOUSE , and he is NOT IMMEDIATELY replacing all that OLD crap painted existing horizntal sections . What he cannot afford it ? He at least should have put non combustable material like concrete board between that joist as he shows on the photo . He was in the attic to take the photo . it was accessable. I understand walking on that brittle roof is VERY tricky to replace out that C pipe . Right hire someone , its your OWN house . Maybe , whats his name , from that TV show can go over there , ...
@ironqqq
@ironqqq 7 ай бұрын
1:47 your vacation is a really HOT one 🔥🌡
@KenTraining
@KenTraining 7 ай бұрын
yes it was....
Quick Inspection Tip: Inspecting Water Heaters
10:30
International Association of Certified Home Inspectors (InterNACHI)
Рет қаралды 48 М.
Chain Game Strong ⛓️
00:21
Anwar Jibawi
Рет қаралды 39 МЛН
It’s all not real
00:15
V.A. show / Магика
Рет қаралды 18 МЛН
Gas Water Heater B Vent
21:00
Plumbing Solutions, LLC
Рет қаралды 135 М.
A Basic Composition Shingle ReRoof with B VEnts   Getting It Right
16:07
Exteriors by Gary Whillock
Рет қаралды 21 М.
10 Reasons Why You'd FAIL a Plumbing Inspection! | GOT2LEARN
7:36
Vent Pipes and the 4 categories of heating appliance ventilation
3:46
Vent Sizing multiple appliances with B-vent pipe
13:55
Ken Delcore
Рет қаралды 10 М.
Water Heater Needs Venting
20:09
How to Plumbing
Рет қаралды 55 М.
92% of Homeowners Use Teflon Pipe Tape Wrong - Here's Why it Leaks
5:33
Silver Cymbal
Рет қаралды 4,3 МЛН
Backdrafting Water Heater - SIGNS and CAUSES
4:28
Rigid Inspections, LLC
Рет қаралды 11 М.
Installing Flue Pipe, Leak Testing Gas Pipe For New Heating System
20:35
The HVAC Hacker
Рет қаралды 104 М.
Chain Game Strong ⛓️
00:21
Anwar Jibawi
Рет қаралды 39 МЛН