Powerflush Couldn't Shift This Blockage!

  Рет қаралды 6,133

CP Utility Solutions

CP Utility Solutions

Күн бұрын

Пікірлер: 22
@plumbertime
@plumbertime 2 жыл бұрын
No valves on combined feed and vent! Assuming you know that but just incase. Microbore should be banned!
@brendanfisher2528
@brendanfisher2528 2 жыл бұрын
I have connected my pump to the valve before and pressurised the blockage until it clears. A very old youtuber called 'tomplum' did it on one of his videos.
@cputilitysolutions
@cputilitysolutions 2 жыл бұрын
Yes I've seen this method before too. But I don't know if it would have worked on this particular one. Hate microbore anyway so was glad to cut it out completely!
@bluedwarf8858
@bluedwarf8858 2 жыл бұрын
Nice video, I've got a question as I'm not an expert, instead of taking the radiator off and doing what you did wouldn't it have been easier to point that imaging camera at the radiator pipework to see if heat was flowing to the radiator
@cputilitysolutions
@cputilitysolutions 2 жыл бұрын
I did that at first and was getting the same result, so before I did start cutting into the pipework I wanted to be 100% sure the radiator itself wasn't causing any issues too and this way I knew for sure it had to be the pipework
@bluedwarf8858
@bluedwarf8858 2 жыл бұрын
@@cputilitysolutions got you, good thinking
@leestaps
@leestaps 2 жыл бұрын
Was about to say the same , take handle off at least , good video as usual cp 👌
@mikearthur2586
@mikearthur2586 9 ай бұрын
Why didn't you connect the flush to the trv and locks locksheild. Back and forwards action 👌🏼. 10mm and below is a c%#t though.
@cputilitysolutions
@cputilitysolutions 9 ай бұрын
I had everything else shut and was using FX2 as well and it still wouldn't shift it. Only option was to re-pipe that section
@TheMaintenancePlumber
@TheMaintenancePlumber 2 ай бұрын
Great video how do you factor that into your price ?
@cputilitysolutions
@cputilitysolutions 2 ай бұрын
Thanks man, I explained to the customer whilst at the job that this is what I need to do and this what it will cost
@sharazali-tabassam3033
@sharazali-tabassam3033 2 жыл бұрын
Hello, great video! Had a question about the difference between sludge and the black water that comes out. I attempted a magnacleanse flush through an old open vent (microbore system). All water came out same colour as coke but the magnets caught nothing. What is this water? And how does it form? Is it still sludge but a weak form of ferrous oxide? Let me know thanks.
@psi10001
@psi10001 2 жыл бұрын
Bacterial growth, open vent allows oxygen in to the system water. You can use biocide and flush system with clean water, then add inhibitor. Best of converting to use a filling loop and remove open vent.
@sharazali-tabassam3033
@sharazali-tabassam3033 2 жыл бұрын
@@psi10001 so bacterial growth causes water discoloration? Even if the majority of the run is in plastic pipes... does this water block and form inside a radiator (same way as sludge)? Because I have never heard of bacterial growth being that potent to change the water colour and viscosity! BTW thanks for answer psimpson747!
@psi10001
@psi10001 2 жыл бұрын
@Sharaz Ali-Tabassam all ferrous oxide is magnetic, you can drain some of your coke coloured water in to a clear plastic water bottle and hold a magnet to it to check. If the system water is not clear, your only non-magnetic options that colour the water are bacterial growth, inhibitor or system cleaner. You can get Fernox to lab test the system water, or try the test strips and a TDS meter.
@sharazali-tabassam3033
@sharazali-tabassam3033 2 жыл бұрын
@@psi10001 thanks for the reply. I know ferrous oxide is rust. I am aware of that. I also did catch the water and test but no luck (got nothing on magnets). The black water was non magnetic. But I just can't figure out what it is (as the magnacleanse magnets caught nothing at all). If I check on sticks sure it might have been more acidic or alkaline. If it was acidic, this would eat at the rads and create ferrous oxide (rust). Thus causing atleast some magnetites to be caught by magnets as it is pressed steel. It's been bugging me ever since I have done the job, what was that water? How does it form? As I myself cannot explain to the customers the whats, whys or hows.
@sharazali-tabassam3033
@sharazali-tabassam3033 2 жыл бұрын
Also how do I check for bacterial growth? What testing methods are out there? Tds sticks i'm pretty sure tests for water hardness which is more alkaline. Would this change viscosity of water? If so, how? Thanks.
@leestaps
@leestaps 2 жыл бұрын
Regarding valve on combined feed and vent that is
@jasonwhittle5008
@jasonwhittle5008 2 жыл бұрын
Good find mate 👍
@cputilitysolutions
@cputilitysolutions 2 жыл бұрын
Cheers mate
@colin4685
@colin4685 2 жыл бұрын
Probably blew all the rads off the wall if it's piped in 10mm
Powerflush that didn't work out
12:30
CP Utility Solutions
Рет қаралды 8 М.
Flushing a microbore system
13:01
CP Utility Solutions
Рет қаралды 7 М.
УНО Реверс в Амонг Ас : игра на выбывание
0:19
Фани Хани
Рет қаралды 1,3 МЛН
Who is More Stupid? #tiktok #sigmagirl #funny
0:27
CRAZY GREAPA
Рет қаралды 10 МЛН
ADEY MAGNACLEANSE CLEAN HEATING SYSTEM SLUDGE
21:49
plumberparts
Рет қаралды 258 М.
How to power flush central heating system
16:42
Urban Plumbers
Рет қаралды 96 М.
toms top tips blocked rad pipe
13:22
tom plum
Рет қаралды 33 М.
DIY Power Flush Your Heating | Get More Heat for Less!
7:19
Skill Builder
Рет қаралды 51 М.
Powerflush Popped A Rad Valve! - A Day In The Life Of A Gas Engineer 67
17:59
heating zone valve problem
14:21
keith jackman
Рет қаралды 84 М.
Heating Hacks: How to Safely Unblock A Cold Feed Pipe
16:25
HeatingGeek
Рет қаралды 14 М.