I think that is the best way to utilize a generator with solar. A few months ago I did the same but used a much smaller 48v charger. When I need to charge up my battery bank , I start the generator and run the charger only. You can really optimize your battery usage when you know you can quickly charge them up. If you calculate the cost of a larger battery bank to handle any eventuality and the cost of fuel for a generator, the decision to go this way is a no brainer.
@teknologyguy5638 Жыл бұрын
I like how it's modular, those look very similar to server power supplies in their size... makes me wonder if that's what they are using in a custom configuration. Easy reparability.
@termiterasin Жыл бұрын
hopefully it lets you run the unit at half capacity if one fails.
@rickyreynolds17 Жыл бұрын
Identical to 48v telecoms power supplies
@Sylvan_dB Жыл бұрын
They sure do look like server supplies. Even the card edge connector appears as if it could be the same.
@jfbeam Жыл бұрын
Server or telco power modules. I didn't see a model number. It's not repairable if you can't get the modules.
@zaprodk Жыл бұрын
It's 100% some Huawei/Emerson Telco 48V power supplies. I have a few from a 4G Telco rack i tore down, and they are fully programmable via CANBUS where you can regulate voltage and amps, and ofc. read out vital data.
@AdamDeLayDIY Жыл бұрын
Morning David. Thanks for the video. Thought I would share that the Victron Shunt has an update now which will allow it to remember the state of charge when it loses power. When you open the Victon app, you’ll see the red exclamation mark over the settings icon. That update made a world of difference for me and my testing! No more having to remember the SOC when you power down!
@DavidPozEnergy Жыл бұрын
Thanks for letting me know. I'll check it out.
@yankey4 Жыл бұрын
I was going to say the same thing.
@outoftexasRev7v9 Жыл бұрын
Thanks for the informative video! I bought one of those today in person at Signature Solar... they have grown so much since the first two times that I shopped there. Remodeled reception area and office area and all the employees were so friendly and helpful! James S. has really done a great job with growing the business👍
@awrosemba Жыл бұрын
I preordered this a week ago…hoping it would work for me. I feel better after seeing your review.
@xpatrikpvp Жыл бұрын
In the latest firmware of the victron smart shunt you can enable it to keep the SOC after a power loss!
@stevenfrazier8939 Жыл бұрын
Using a MidNite Solar CLASSIC 150 MPPT Charge Controller, Operating at 150 Volts with a Max Current of 96 Amps. And hooked to a #DC1248AC DUAL CORE PMG/PMA by Thermodyne Systems and powered by a 6+HP Diesel engine all for under $1,700 works the treat for me. It is cheap to build and operate and very efficient. We make our own fuel using waste Veggie-Oil that has settled for two weeks and filtered down to 25 microns. We add 10% gasoline and filter to 1 micron and use it in our diesel generator. All of our filters are polyester cleanable and reusable. So, we have an efficient generator and cheap fuel that cost between 3-9 cents per kilowatt hour depending on if it is a 10% summer or 30% winter blend. We live in Michigan where the grid is 17.4 cents per Kilowatt Hour. So, this cost is less than the power grid. Even if you do not make your own fuel, it is still a good way to make energy.
@chasemartin4450 Жыл бұрын
Just a couple server PSUs in the box - clever!
@rongray41188 ай бұрын
Thanks for posting, David. Always appreciate a straightforward review. We did get our unit - finally. Looking forward to seeing how it works on the Absolyte.
@cryptkeyper Жыл бұрын
I pre-ordered one a while ago. Still not got mine. But glad to see a review on it.
@wcoekaer Жыл бұрын
Awesome - just in time, my charger is arriving Monday. Signature just shipped it!
@shonginnis27 Жыл бұрын
So I’m off grid and have been buying from Signature Solar. Everything has been great. Have bought one EG4 battery, has been great and a growatt inverter. If this is done correctly, that is on a off grid set up, you will be using the lower voltage instead of 240. If you built your set up to run only 110-120 v, you will be using a smaller generator. The idea is to use small generators not 240. The bigger the generator, the more gas you use. If you have a shorter charge time it maybe a better deal.
@DavidPozEnergy Жыл бұрын
I'm less concerned with run-time, and more concerned with kWh per gallon of fuel.
@BobHannent Жыл бұрын
60 degrees Centigrade is very safe for most power electronics, although it will depend on what the temperature of the components inside the PSU is, not just the surface of the unit.
@benssolarandbattery Жыл бұрын
That's an amazing price for a 48v 100a charger! Thanks for sharing!
@typxxilps Жыл бұрын
What price ? I can not find a 100 A charger on the website.
@thisismov Жыл бұрын
@@typxxilps Its hard to find using his link but its $399
@IceLanderve Жыл бұрын
This is definitely better for your batteries not to mention cheaper to replace. Generators are tough on electronics.
@VinceBadovinatz88 Жыл бұрын
I never knew all this stuff I'm glad I saw the video I haven't run my generator in awhile but it's good to know that they suck hahaha
@paul.phillips Жыл бұрын
The hot exhaust air blowing on the DC cables might not be great, the insulation may begin to deteriorate over time. They probably should have routed those out the same side as the AC in instead, which would solve that problem and may allow for more efficient cooling. Overall looks like a good unit, I have the lower powered, older EG4 charger, but 5kw charging paired with a 240v generator is certainly a great option to supplement solar when the weather's not great.
@Scat.original Жыл бұрын
After rotating so exhaust is up, I would route cable to the left and anchor them to stay out ot the way of the exhaust heat
@jamesmccracken8428 Жыл бұрын
I ordered and just installed my new charger. Out of the box one of the two modules had slipped out of the socket during shipping. Noticed this due to the unit providing only half of the selected charge current. A couple of issues worth noting; as David mentions the unit does not have a delay feature to allow your generator to warm up. I will be adding a timing relay to do this. Also this unit would not work with economy mode on my Honda EU6500. The charger would instantly fault when the generator was attempting to throttle up. When the charger faults it looses the voltage and charge current settings. With economy mode off the unit does a great job changing my lithium batteries and eliminates the sketchy transfers that my inverter/charger produced when the generator came online. I would like to see some added features but do think the unit is very useful at a good price.
@enockbaahaduful7048 Жыл бұрын
Hi... I'm Enock from Ghana and living in Germany. I just subscribed your channel and I really like what you do.
@00000005547 Жыл бұрын
Alternatively you could also just rectify the 240v from the generator and feed it into a charge controller. Just have to make sure that it's within the charger max voltage. 240vac rectified is like 320vdc. This is actually how those big, tens to hundreds of kVA UPS systems work. Instead of using normal diodes they just use SCRs which are basically diodes you can switch off at the crossing point, this way they can control the output voltage and keep the batteries charged 24/7, while the inverter is always running producing clean AC I think it goes without saying that high voltage can be dangerous but is perfectly safe as long as proper safety methods are used.
@jeffreykparker Жыл бұрын
Dear Brother David, I've been expecting this review from you, and you've not let us down. Many thanks for your menthodical, well-explained approach! Now, a request: Given that many of us off-gridders have been using "ordinary" (non-inverter) generators to charge our earlier generation (non-hybrid) systems -- mine is a Magnum 4kW 48v inverter with a Midnite Solar Classic 150 charge controller -- but now are embracing hybrid inverters, can you please kindly run this test again with any old non-inverter generator? Given that the guts of this Chargeverter come from the same Voltronics factory as the MPP Solar and EG4 hybrid inverters, it's crucial that we know the Chargeverter can accept "dirty" AC that our older inverters digested without issues. I don't want to have to buy an inverter generator to use this $400 charger! Best thanks!
@DavidPozEnergy Жыл бұрын
If you are in MA, bring your generator by and we can test it. You are not the only person with this request. I'll ask around to my friends/family and see if someone owns an older style generator to test.
@jeffreykparker Жыл бұрын
@@DavidPozEnergy Given that I'm on the California coast, the odds of my schlepping my genny over are slim! But I do hope someone nearby will offer one up. What about your diesel genny? Can't imagine its signal is too pristine. Thanks again!
@keything8487 Жыл бұрын
@@DavidPozEnergy id like to see that as well
@carlosmacedo6442 Жыл бұрын
My system was designed with help from the EG4 design department. Here's what they said in regards to something similar to your request: "If you wanted to use a generator to charge the batteries you would need a transfer switch to go from the grid to generator power since the inverters only have one AC input port. For a generator we recommend a generator with twice the wattage rating of your inverters. This is to account for dirty power. Dirty power tends to happen when a generator is operating at over 50% capacity and will produce voltage spikes and lulls that the inverters will not like. Since you have 13kW of inverter capacity it would take a pretty large generator. If you didn't want to buy a large generator you could use battery charger plugged into a generator." At the time, he pointed towards a different, smaller charger they had, but then the 5000 came along, so I think that it would apply as well, meaning, these battery chargers account for dirty power.
@patrickcoyne1292 Жыл бұрын
just got mine set up. in alaska i have some short days, so this is something i will use for probably 3 months out of the year. i use an 8000w generac. charged my 300ah bank at 75amps, from like 60% in 1.5 hours….i’m excited about being able to run my bank lower and charge faster instead of having to top off more frequently.
@DavidPozEnergy Жыл бұрын
Yeah, Alaska would need a pretty good generator system. Thanks for sharing.
@patrickcoyne1292 Жыл бұрын
@@DavidPozEnergy was using the 18a with a 2000w generator and it’s just to much wear and tear and time. so this unit is super helpful. i wish that it could be mounted differently. or atleast had longer leads.
@RayCampbell-c5s Жыл бұрын
I am off grid with a EG4 LifePower 4 48V battery bank. I just bought the EG4 Chargeverter and I want my generator to start automatically at 47V and shut down at 52V to power the Chargeverter when solar is not enough. Signature Solar recommended using the EAZY-VLC 2.0 12V dual programmable relay control cycle delay timer. I have a Westinghouse WGEN 7500 DF generator that has a remote start. I plan on
@DavidPozEnergy Жыл бұрын
I've never used that Voltage controller. Looks like it can work well.
@joshg1244 Жыл бұрын
Give the 120v a try on the review. Wonder how well that works
@mondavou9408 Жыл бұрын
Best video on this product that I've seen. Thanks.
@DavidPozEnergy Жыл бұрын
You're welcome.
@defjamsgreen Жыл бұрын
Great product that will sure to get the batteries charges up .🤙🤙
@thinde88 Жыл бұрын
Got mine coming now! After two years off grid I haven’t had to run a generator yet but it always caused me anxiety since I bought a normal non inverter generator and didn’t want to run it into the utility in on my inverter.
@RayCampbell-c5s Жыл бұрын
Have you looked at how to do this? I may use the 7 pin connector on the generator and rewire the internal wiring to the connector. My generator uses the same push button to start/stop the generator.
@EliteRman121 Жыл бұрын
At 14:17 I hope you flipped the DC cables on the top to the left side of the charger as having the hot exhaust air blow directly on those cables doesn't seem like a great idea. Not an expert, just seems logical to me, this is an awesome video. I am of the opinion that it makes way more sense to have a generator available to charge your system if you plan on going off grid so you don't need to go over kill with solar panels and battery capacity in order to make up for those cloudy days or poor weather. I think it's way more practical and cost effective, it also has the added bonus of having a generator available should your inverter ever fail. I feel like most people wouldn't mind needing to run the generator for a few hours to top up when weather is an issue, and since you are capturing most of the electricity generated it's actually not bad on fuel cost. What are your thoughts?
@DavidPozEnergy Жыл бұрын
My goal is to cover my electrical needs with solar 99% of the time. That leaves 1%, or 3.65 days per year that I need to run the generator. I'm OK with that.
@MrButuz Жыл бұрын
Hey David there's a setting on the latest firmware of smartshunt to always retain the previous SOC when it loses power so no more jumping back to 100% (I always thought that was stupid).
@VinceBadovinatz88 Жыл бұрын
I totally agree. I have a feeling my shunt isn't telling me the proper SOC on my batteries either I don't know really how to set it I have to read some directions somewhere again.
@gees6858 Жыл бұрын
@davidpoz, i am wondering if you lose power input. Will the chargeverter retain the last setting once it gets back the power input back ? Or do you have to re configure the amp/voltage ?
@patrickcoyne1292 Жыл бұрын
mine retains the info
@tjmooney4181 Жыл бұрын
Awesome thanks a lot I am supposed to be getting my eg4 chargeverter any day now and I have the same Honda 6500 generator so this video was perfect for me 👍
@VinceBadovinatz88 Жыл бұрын
I have a little Predator 3500. And I have a Amitabh 4000 light pole I'm not sure the specs on that generator. I don't think my 3500 would do much haha I'd have to set set the charger at 50% or something or 50 amps I mean
@ericross9768 Жыл бұрын
Good video David. Especially liked the actual measurements which often are in specs but seldom given in videos. Do you have any idea of the need for inverter generators to supply this charger or of the tolerance for modified-sinewave type chargers?
@browsedeweb8834 Жыл бұрын
Thanks for doing the test. I may eventually buy one if they appear to hold up over time. I have the Honda EU7000is and it can't start my 4-ton HVAC condensing unit even with a soft start. My Growatt 12k inverter likely can, so if I ever have a prolonged outage during a heat wave, I would be able to have the Honda run the Chargeverter while the Growatt runs the house loads and handles the large inrush spikes. This would prolong the run time of the 20kWh LIfepower4 battery rack provided that the average house load stays below the max continuous output of the generator which I converted to run on natural gas.
@SkyNoris Жыл бұрын
I wish this charger was out a year ago! Then I'd probably grabbed it. Right now, I just use a 16-amp 48v charger a few days out of the year to keep my 50KW battery bank alive. It seems to put out around 600 watts. It runs usually for 12-18 hours whenever I need it. I've got it connected to a 20amp Wi-Fi switch currently. So, I can switch it on and off remotely from anywhere. I guess next step would be to get it to kick in automatically when my batteries are low. But I'll probably just buy a generator or run 240v grid power to my solar shed. This way I could take advantage of my dual 100amp chargers built in my Victron inverter. The huge Victron inverters utilize software that helps them use less running power. I've seen my 15KW inverter running on 90 watts before.
@JayDee25895 Жыл бұрын
Congratulations on 200k Subs! 👍🏻
@DavidPozEnergy Жыл бұрын
Thank you.
@jeffreysylvester905 Жыл бұрын
Thanks Dave! The instructions for this unit left me with many questions. You answered them all!
@DavidPozEnergy Жыл бұрын
Glad to help
@eliotmansfield Жыл бұрын
You can make something similar from a Huawei R4850G2 power supply - they are used to charge backup lithium batteries on cell towers - they used to be really cheap to buy (less than 50 bucks) but looking now they seem to be expensive now. You can also get dedicated 48v generators as well now - which avoids the need for the genny to invert to ac mains and the power supply to convert back down to dc
@andrewfidel2220 Жыл бұрын
The Huawei gear would be going up because they've been banned from the US so anything you see is new old stock.
@mgd09050 Жыл бұрын
David, thanks for the review of this. I'm interested in one to pair with a j1772 on my box truck so I can charge at public ev chargers. What I can't seem to get an answer on is if the neutral is required or not for the 240v input. The J1772 standard is two hots and a ground, no neutral. Any chance you could check?
@ChrisLhamon Жыл бұрын
Cool project. I'd like to see an update on the house and garage. I'm buying a 100-year-old house that needs some work. I've already started on improvements. By the way, solar is definitely on the list because the roof is perfect for it. You were an inspiration for both the house and the solar. I can't give you all the credit for that, but you DEFINITELY deserve some credit. I may even try cellulose insulation in the garage. Thanks for the videos!
@DavidPozEnergy Жыл бұрын
I'm glad my videos help in some small way.
@ChrisLhamon Жыл бұрын
@@DavidPozEnergy Well, I just found that there appears to be no insulation at all on the exterior walls. I live in Ohio, so that's not good. I'm probably going to do a blown-in insulation, but I'm not sure I'll have time to do it myself. Either way, your insulation videos are a BIG help in my understand of that process. I'm still a little concerned about how much that cellulose settles.
@georgedrenes8143 Жыл бұрын
I've been wondering about this charger. Thanks for doing this video. It certainly helps take the guesswork out of my decision making process. Someday I hope to figure out why I've never been able to get my two spf 5000 GW inverters to run in parallel.
@solaroffgridlivingeurope Жыл бұрын
Will be working with small, non inverter generator. I use 3000 W AVR generator, and I must set on mppSolar controler about 10 Amps to start it, and then raise to 20, 30 and finaly to 40A. Maybe that charge controller have softstart.
@wideawaketotruth5301 Жыл бұрын
As always, thanks David.
@vincei4252 Жыл бұрын
Are the battery terminals isolated from the neutral/ground on the generator side ?
@alexanderkolyshko Жыл бұрын
Thanks for Celsius 😀 during temperature measurement.
@KumiOriFarm Жыл бұрын
I was hoping to see you share how it compares to using the other gen-to-battery setups, in over efficiency that is.
@NoelBarlau Жыл бұрын
Pretty nifty little unit. Thanks, David.
@waynewilliamson4212 Жыл бұрын
good teardown and review...thanks!
@basspig Жыл бұрын
I just ordered one of these from signature solar it's supposed to be shipping in about 2 weeks.
@termiterasin Жыл бұрын
This is cool. I'm planning on buying a chinese 4kw inverter, the new EG4 500v 100A MPPT charge controller, and maybe this now! I'm getting this setup instead of a EG4 AIO because they have extremely high idle consumption around 150w which is too much for my needs.
@DavidPozEnergy Жыл бұрын
Great. If you decide to use any of the affiliate links in the description, it would really help out the channel.
@larrymajorana9269 Жыл бұрын
I bought one of these to charge a golf cart with the SPIM08HP batteries like the one you built awhile ago. Seems ideal for that. Heavy duty, programmable at about the same price as other lithium golf cart type chargers. I’m connecting them with Anderson 175A connector so when I park it’s easy to just plug & play. Plan to power directly from Outback AC inverters or generator via transfer switch. What do you think? I’ll send update when installed. Great video!
@WellsNursery Жыл бұрын
It would be awesome to see the Kw of charge through this charger per gallon of gas in the honda so perfectly matched.
@L3thalComprehension Жыл бұрын
another great review david thanks for showing us alternatives for charging 👍🏽. total side bar your hair evolved from a young michael mcdonald to a slick morgan wallen lol. 🔥💯
@DavidPozEnergy Жыл бұрын
Thanks. I'm having some fun seeing how the hair evolves. It's nice not being forced to have a high & tight any more.
@michaellane4762 Жыл бұрын
David, Great video. One thing I think you forgot to mention, How long did it take for your gen to charge your battery bank ? Thank-you, Mike.
@DavidPozEnergy Жыл бұрын
My battery bank is made of 6x EG4 batteries. Each EG4 battery is 100Ah. 6 in parallel means my whole battery bank is 600Ah. If I was at 0%SOC, and charged at the full 100A, then it would take 6 hours to charge the battery to 100%SOC. However, I don't suggest that approach. As I showed in the video, I'll be charging at 80A given my generator. And, I wouldn't wait until the batteries were dead, and I wouldn't charge all the way. It's far more typical to charge, perhaps, 40% of the total capacity in an off grid situation. That would be 600Ah*0.4/80= 3 hours.
@wjbieber Жыл бұрын
By the way, I love all your content.
@JPHER217 Жыл бұрын
Hey DavidPoz. Looks like Growatt is about to launch the SPF 6000 ES Plus inverter. Would be awesoe if you could try get in contact with them and see if you can do a 1 phase/3 phase review on the units, im stoked on them because dual MPPTs.. Would be sweet to see you do a review on them like the ones you did for the 5kw units.. Keep up the nice work.
@charliemorgan6553 Жыл бұрын
Hi David, thank you for videos. Did you try powering your loads with the inverter while charging? Thanks
@DavidPozEnergy Жыл бұрын
No. I wanted to measure power at the shunt during the test.
@charliemorgan6553 Жыл бұрын
Thanks For your response. I Was wondering if you could power your loads from the charging power provided by the Chargeverter. I have a small gas generator, 2000 W, and this device may help me charging my batteries using my generator. I have a Schneider XW +so I have enjoy your recent videos on that inverter. Thank you again for your videos and please continue doing what you do.
@rufelestrada97916 ай бұрын
@DavidPozEnergy I was wondering along with Charlies' question, IF you can safely turn on your INVERTER while charging with this new device? Will all that amperage fry the Inverter? I would think not, because they are ready to accept all the amperage from the batteries/banks, no issue... Your thoughts?
@twsconsulting Жыл бұрын
Idle loss should be readers at the input (AC) side
@kimburndred3218 Жыл бұрын
Thanks for the review. I have a couple of questions. 1. Can the chargeverter be used while the inverters are operating? 2. Since there's no BMS what happens when the batteries reach full charge?
@DavidPozEnergy Жыл бұрын
Yes, the chargeverter can be used at the same time your inverters are being used. This is a tool that mostly will be used for people living off grid. So, the inverter must be up all the time. As for the BMS. The chargeverter should be set to a lower Voltage than your batteries would be full. For example, my batteries can go up to 58.4V, but I set my chargeverter to 55.0V. This means the chargeverter will never fully charge a battery. However, this doesn't mean you don't need a BMS. You still need a BMS if you are using lithium batteries.
@DoyleShadduck Жыл бұрын
100 AMP..lol Hope you’re planning on getting a new generator every six months, batteries every year because that’s one heck of a load. Neither the batteries nor the generator would like being run at that much load. I like that you can turn it down so as to bring it down to a more realistic level, however why not just get one of the millions of quality automotive style chargers? I’ve been using my little ten amp Solar Pro-Logix from Napa auto parts for 3 years now and it works great. I’ve been 100% off grid just using a 3500 generator to recharge everything. It even checks the batteries then runs special cool down modes and ramp up profiles to charge the best way possible. The downside is it only works on, AGM, GEL or flooded. $119.00 PS:Can you even charge Lithium batteries at that rate without damaging the BMS?
@proudwhitesettler7746 Жыл бұрын
Good stuff. Liked and subscribed.
@northidahodreaming5657 Жыл бұрын
thanks for the review.....I just ordered on of these
@neomatrix2722 Жыл бұрын
Thank you for sharing I didn't realize that when you're charging your battery through the inverter that you weren't able to invert meeting that you don't have hydro so this is a great way to do it now I'm running a 24 volt system is this offered any 24 V configuration
@DavidPozEnergy Жыл бұрын
Signature Solar sells a few different 24V chargers. They have an 10A, 30A, and 35A. Right now the 30A is on a really good sale: signaturesolar.com/eg4-battery-charger-24v-30a/?ref=4_rHcgZ9x-TiF-
@bearupfarm1818 Жыл бұрын
Is it only for lithium batteries .
@WellsNursery Жыл бұрын
I purchased on an installed a 30amp 250 volt plug in battery room and couldn't make it charge mor than 49.8 amps I thought cord was wired wrong I turns out after opening the unit one of the chargers were unplugged and main positive lead in dc breaker was completely loose. tighten screw and pushed charger back into socket and now works fine 100 amps confirmed with amp meter.
@DavidPozEnergy Жыл бұрын
I'm glad you figured it out. Sounds like quality control is lacking.
@brianlooney3032 Жыл бұрын
So, you should do a show on how long it takes to charge different size battery banks at different c rates ECT. With this charger
@SylwerDragon Жыл бұрын
i need to check if it for Eu as well
@coryr63598 ай бұрын
Right. on.
@bearupfarm1818 Жыл бұрын
David when you started your charger you turned the inverter off. Did you leave the inverter off during the 1.5 hrs of charging?
@NeverTakeNoCut-offs Жыл бұрын
David, I saw you had your generator set to 120 V, did you change that for the test to 240?
@DavidPozEnergy Жыл бұрын
Yes. At first the charger didn't turn on because that switch was in 120V mode, and that means the 240V outlet is off. As soon as I switched it back to 240V the twist-lock turned on and the charger turned on. You have an eagle eye.
@NeverTakeNoCut-offs Жыл бұрын
@@DavidPozEnergy hehe, only because I've done the same thing myself. I just ordered one of these.exactly what Ive been looking for..
@skipchang Жыл бұрын
David, loved all of your solar/battery videos. I learned a lot from your videos. I'm in Florida and setting up an emergency power backup system using EG4 48V batteries and 3000W inverter/solar charger/ac charger combo unit. Since I don't have solar, if the power outage drags on, my plan was to use the gas power generator to charge up the batteries. The Chargeverter seem like a perfect fit. The one question I have is how do you keep providing the AC power via the inverter while you are charging the batteries? It seems like if you connect the Chargeverter to the power rails on the EG4 battery rack and not disconnect the inverter, then the Chargeverter is just going to be supplying power to the inverter. If you turn off the inverter or disconnect the inverter, then you have no power to the house. What am I missing? Thanks.
@DavidPozEnergy Жыл бұрын
I don't think you are missing anything. You said you plan to use a 3000W inverter, but didn't mention the generator size. The Chargeverter can go up to 100A, so if the battery is at 54V, that's 5,400W. If you haven't bought the generator yet, I'd look for one between 5kW and 6kW continuous rating, and limit the Chargeverter to 90A. Let's say you are pushing 5kW into the battery busbars, and you are pulling 3kW to your loads through the inverter. That means 2kW will be charging the battery at the same time. But, if your loads drop to 1kW, then you have 4kW charging the battery. You still have 5kW from the Chargeverter.
@skipchang Жыл бұрын
@@DavidPozEnergy David, that all makes sense. Thanks for the explanation. My parts are scheduled to start arriving this Friday. Wish me luck 🙂. Thanks again.
@puddlejumper06 Жыл бұрын
David, thanks for the video. I enjoy your videos, nicely done. I am not sure if I am seeing the benefit of using this unit to charge a battery bank. Are you saying the new Chargeverter is more efficient at charging a battery bank than the Schneiders and/or Growatts? Both inverter brands you have will charge the battery bank, I am not seeing the benefit, I guess. Do these inverters cannibalize power to charge battery banks vs when using a gennie? I bet I am over thinking this.
@DavidPozEnergy Жыл бұрын
Actually, the Schneider inverter is a little more efficient at charging the battery than this is. In my previous video I showed how switching the loads back and forth from generator to inverter can make the lights blink. This charger eliminates that.
@kokopelli314 Жыл бұрын
Looks like 2 Meanwell hot-swap RCP-3K1U maybe... I made something similar for my 4kw 100v ebike
@tonyshipman257 Жыл бұрын
David, I was wondering why you did not use your meter too vs the panel and your phone alone?
@143110096 Жыл бұрын
😎Thanks David! Very good information you provided.
@clarencewiles963 Жыл бұрын
Thumbs up 👍 good demo!
@william2davo Жыл бұрын
Hey David, Great Video. Could you set up the Honda as a 2 wire auto start stop function that triggers when the battery reaches a certain level? Ive been looking for a 2 wire start stop generator thats budget friendly but cant seem to find anything in the USA thats quiet and smaller. I think you could make a great separate video on this setup. Im sure you could find a good way to do this.
@DavidPozEnergy Жыл бұрын
My Honda EU6500 doesn't go to 2-wire easily. But, the newer version is EU7000, and that one will do a 2-wire easy.
@joeledwards6587 Жыл бұрын
i love how your hair is coming along, I didn't watch a lot of your vids from the time you had shaved your head so was surprised to see it :)
@DavidPozEnergy Жыл бұрын
Thank you. It's fun not being required to have a high & tight anymore.
@yankey4 Жыл бұрын
Love it. That looks nice. I would love to have one of those. That's how I use my generator the most. Just put the power into the batts. Let the inviter do it's job. Thanks for sharing. God bless.
@DavidPozEnergy Жыл бұрын
Thanks for the comment Bobby.
@kennethalmond8922 Жыл бұрын
Thank you for the vid! It wasn't quite clear, wondering if you can you leave the unit off, fire up the generator, and then... come inside and throw the unit circuit breaker to start charging? Is there a reason to leave it on all the time or were you just showing what happens with battery only? .I ask because in my case it's a manual generator start about 200ft from the battery bank - e.g. start the generator without load and then go in and enable the charging at the battery but also cut-off charging at the battery if the generator struggles.
@DavidPozEnergy Жыл бұрын
I wasn't sure, so I just went and tested it for you. It worked fine. I had the AC side connected with the battery circuit breaker off. Nothing bad happened at all. Then I switched off the DC breaker first with the generator still running. Yes, that's fine. If you decide to purchase one, it would help out the channel to use the affiliate link in the description.
@tarassu Жыл бұрын
How many inches of barn corns does it weight? Liquid, Alabama type.
@baquero2175 Жыл бұрын
Hello David, as always, your videos are simple but super educational. I have a question and whether you can put 2 charverters at the same time to charge the same battery bank since I have a generator that generates 15KWA and 22KWA to start and I would not like to waste time if I can do it in 1 hour it is much better than 2 hours and at the same time At the same time, it saves me energy since the generator will generate it in the same way, but it would not really be used. I would like to use the generator directly to the inverter, but the people at Signature do not recommend it because of those at Dirty Energy. Can you give me your opinion and options, thanks.
@DavidPozEnergy Жыл бұрын
Yes. Inside the Chargeverter there are two power supplies in parallel. So, right there, it's not a problem to parallel them.
@rickharold7884 Жыл бұрын
Awesome charger. Looks great.
@midnightmotors7202 Жыл бұрын
Great work as always. Do you have an estimate of the fuel efficiency (KWh / gallon)?
@DavidPozEnergy Жыл бұрын
Yes. My video with my Honda generator showed 5.8kWh/gal. Check it out if you have time. I test it at several different current settings.
@midnightmotors7202 Жыл бұрын
@@DavidPozEnergy Awesome!
@DennisWintjes2 Жыл бұрын
Thanks for sharing David! Like #598
@ko2890 Жыл бұрын
Newbie here. I check on everything to be safe. It looks like you connected this into your bus bars. Is that correct?
@tpike46w Жыл бұрын
Great review I just had a couple questions.1 can the inverter still be powered on and running power to the off-grid cabin while charging the batteries and 2 can this chargeverta run at the same time that the PV is charging batteries also? Ty
@DavidPozEnergy Жыл бұрын
Yes! That's one of the nice things about "DC coupling". Multiple things can be connected and ON at the same time if it's on the DC side. I recommend having some serious busbars centrally located where everything gets tied together (see busbar video).
@tpike46w Жыл бұрын
@@DavidPozEnergy thank you sir
@burnzy56469 Жыл бұрын
Man there expensive but look amazing thanks for video
@simon359 Жыл бұрын
I’m still learning. So what’s the advantage of having 100 amp charger over just going directly from the generator? You would still get 50 A charge into your batteries! The difference didn’t seem that much.
@kgrowden18 күн бұрын
I have an off grid cabin with solar, an 8KW diesel generator, a 48 volt inverter and battery bank of lead acid batteries. I recently purchased 4 - 48 volt lithium lifepo4 batteries to replace the lead acid, that I will run in series to the inverter The inverter has a charger but it is not designed to charge lithium batteries. I have read other articles about charging lithium batteries and they suggest using a smart type of lithium charger. This charger you are reviewing seems to just be adjustable and it is going to charge at whatever amperage you set it at. What makes it any different than any other charger for instance the one that is in my inverter? Is this the best type of charger to use?
@DavidPozEnergy12 күн бұрын
Lithium batteries need a CC/CV charger. This stands for constant current, constant Voltage. Basically, the charger will charge the battery at full current (set by you) until it sees the battery at the pre-set maximum Voltage. I set mine to 56V. Then, the charger switches to constant Voltage mode, where the Voltage is always 56V, but the current lowers from 100% to 10%. Once it reaches 10%, then the charger shuts off.
@jitterz0135 Жыл бұрын
Question, if you had two generators could you run two chargers running to the same battery bank? If you only had the one charger but two generators could you use one of the GroWatt inverters as a second charger with the AC in while still powering the house?
@dayneanderson Жыл бұрын
What a great product. One improvement I would suggest is upgrading this charger to allow charging for 12v/24v batteries. Lots of us out there with smaller systems that would love this feature.
@mickwolf1077 Жыл бұрын
Yes, I'd like a 24v option. A selectable one would be even better.
@jbuszkie Жыл бұрын
David, I like the modular-ness of the main supplies. However.. I couldn't really see from the video.. Is there anything that secures the the internal 2 modules? You just slid them off. Is there something to prevent that say if you hang it vertical? Gravity or vibrations might cause them to slide out if there is nothing mechanical preventing that. I got to believe the EG guys would have something. I just missed it.
@jbuszkie Жыл бұрын
Nevermind.. I just went back and saw the bracket.. 🙂
@rdcabal Жыл бұрын
80A divided by like 8 banks meass easy charging conditions for LFP. Light tickle.
@MichaelBrown-xb6pp Жыл бұрын
Is it rated for continuous use? Could I plug this into Grid power to maintain my batteries while I was still using my Inverters as if they were a giant ups? I understand I would be wasting quite a bit of energy but I still do not have my PV panels installed yet. Slow process but I wanted to get all my inside wiring completed and tested first. It will be an off-grid set up completely separated from the Utility. Thanks for the video.
@DavidPozEnergy Жыл бұрын
Yes, you could do that. I've ran this charger for several hours in a row without a problem. Keep in mind, if you set it up like that you might want to lower the Voltage to 54.5V since it will be floating there. I don't see a reason it wouldn't work for you, but I have not personally tested using the Chargeverter in that situation.
@russbritt41006 ай бұрын
Wonder how this could work with a automatic generator start system
@gioraver Жыл бұрын
Exelente siempre compartiendo contenido de calidad y escaso . Saludos !
@frankz1125 Жыл бұрын
Nice charger, Runs a bit hot. Cheers
@jeffbowers950 Жыл бұрын
Good day David. Been thinking about getting one of these. Can you do a "tuned test" for fuel efficiency & KWh to batteries with tour Honda please. Perhaps run Honda at 75% load to whatever amps that equals on charger. Would love to see a max KWh charged per gallon on a full tank of fuel, without overloading the genny of course.
@DavidPozEnergy Жыл бұрын
Yes, I plan to do a part 2 video to my previous fuel economy test.
@coldbonez5407 Жыл бұрын
Thanks for the video. I am curious how long it would take to charge one battery with just the generator running through the inverter and then running through your new battery charger? How much of a difference in fuel consumption?
@DavidPozEnergy Жыл бұрын
My Schneider inverter is about 93% efficient at being a charger. This new charger is about 90.5% efficient.