Love the DSam spectrum. Glad to see you using a meter to track noise .
@Vicentejmd4 ай бұрын
Love the DSam is the best meter to track noise
@Wav100015 жыл бұрын
When you are in ingress expert (which is what I prefer to use, not ingress scam), press the up arrow hard-key twice and it will zoom your trace in. Unfortunately because of the dynamic range of the meters analyzer, you must use auto AGC when you’re probing with the ONX. You have to be cognizant that if auto AGC is turned on, you have to hit reset whenever you plug in to something new or cause your noise floor to raise (eg: by loosening or tightening a seizure screw). This doesn’t happen when Auto AGC is turned off. You can turn the auto AGC off when you are using yours amps test points though (because they are 20dB, 25dB down etc). With that said, you may be able to get away with using a 20dB probe (such as an iStop) with Auto AGC off to have a better experience chasing ingress. Again, just make sure to zoom the trace in a bit because it will be harder to see the noise: A) because you’re used to the DSAM and B) because the noise will be attenuated by the probes attenuation value
@bbtechbbtech2 жыл бұрын
I have also noted (recently) that the ONX-620 will often default to a noise floor of -60dBmV and doesn't adjust to where you would normally expect the noise floor to be (-40 dBmV). Often times, with a lot of noise you are greeted with a constant "excessive ingress" display and the only to get this to go away is by turning the AGC on. When you turn the AGC on, you can see the noise floor move then as it adjusts (adds attenuation). Sometimes this moves the noise floor down to levels lower than -30 dBmV. This has obvious flaws considering a 25db spike from a -60 dBmV noise floor will only be measured to -35 dBmV which means it's in a "passing" range whereas if the noise floor were accurate from the jump (around -40 dBmV) your spike would be badly failing at -15 dBmV. Not sure why this is happening. In any regard, clearing a house of ingress is so much easier with the DSAM than with the ONX. If anyone knows WHY the ONX 620/630 is defaulting to show the noise floor at -60 dBmV, I would love to hear it. (my suspicion is that the meter is being effected by the downstream channels and may require use of a low pass filter). Still....operationally I would much rather be chasing house ingress with a DSAM than an ONX at this point.
@transitiontelevision3 жыл бұрын
When was the last time that meter was calibrated? Also, the OneExpert might be zoomed out and therefore showing fewer details. Try adjusting your Vertical setting before you rotate the screen.
@ViyaHeadend4 ай бұрын
While usin the ONX-630, Always use Ingress Expert, and NEVER use Average power. You will never see the accurate amount of noise on the line. Max Power and Max hold.
@Henry-vq6tl3 жыл бұрын
I think that's why I don't use that meter for casing noise and stay to the DSAM.
@timcat10043 жыл бұрын
The Viavi blows away the DSAM once you learn it. Turn on heatmap.
@jamesscherz95892 жыл бұрын
JDSU renamed themselves Viavi years ago. I think you are referring to the model# this one is the OneExpert by Viavi.
@louisguzzi47864 жыл бұрын
Why are you even bothering with the 2nd meter? Use D-Sam and path-Trak
@louisguzzi47864 жыл бұрын
Plus you already saw it leave when you floated the output screw. I go to your last tap and start taking drops off.
@F0X_1N_S0X5 жыл бұрын
Love this video!! I hate using ONX to track. there have been no training on using ingress expert. The videos you watch from the company are garbage. I want to physically see someone plugging the leads into an active etc...like what you've done with the taps. We are all just play with it...I no longer have a dsam...😞.
@usernameredacted47317 ай бұрын
To everyone that"s been hating on the ONX 620/30 ingress expert mode... 1. I would bet money that if trained properly on the ONX, you'd never pick up a dsam or 1G again (well. The 1G is pretty tight too). 2. How many of you ran docsis expert first in order for the ingress expert app to lock the upstream channel descriptors?
@charlesgrey1a14 жыл бұрын
I learned if you turn your AGC off you don't have to keep pressing reset.
@YouTubeMajstor5 жыл бұрын
on the dsam instrument do you measure ingress with "pre amp" on or off? and what exactly does this option serve?
@EFFENDICC3 жыл бұрын
change db/div maybe to see the noise better?
@letsTalkgeography4 жыл бұрын
im using VeeX for that same thing not much details Dsam is the best , whats the name of the app in your phone ?
@nvideon6 ай бұрын
path-trak
@fernandovilla21313 жыл бұрын
Nesecitas un filtro que te muestre solo el retorno, por que ese medidor no tiene el diplexor que te separa el retorno del forward, hay uno de la marca pct PCT-BSFA-96-517 Con ese filtro solucionas tu problema, buena suerte 👍🏻👍🏻
@abesgraable Жыл бұрын
Si conectara el medidor al puerto 2 del equipo alli si mediria retorno porque alcanzo a ver que lo tiene conectado al puerto 1 que es el de bajada ( si estoy equivocado perdon 😂😂😂😂)
@justynrodriguez49183 жыл бұрын
Serious question, new MT here. Can you post a pic of that probe, I’ve asked to see one me nothing.
@tony7419833 жыл бұрын
That is a SV03 plug. That is a Signal Vision 03, it is power passing and 0 down. They are way better than an I-stop IMO. Also they have SV05s that are 20 down and power blocking
@rpsmith3 жыл бұрын
Cable TV - Total Garbage! Way past its prime! Bring on the Fiber!
@bbtechbbtech Жыл бұрын
Someone hasn't done their research....cable has been fiber to the node for over 20 years.....and is doing quite a bit or work with even further fiber penetration in a lot of markets. Coax still has a lot of life left in thanks to a lot of the newer technologies (PNM, Adaptive equalization, OFDM/D3.1, Remote Phy, High Split..and more). To call it garbage just shows how little you know.
@rpsmith Жыл бұрын
@@bbtechbbtech -- I'm an IT person. I deal with the shortcomings of cable internet on a regular basis! The coax shared media part of the cable system is the problem. any one of your many neighbors can seriously degrade everyone on that shared segment. any trunk amplifier on that segment can cause hundreds of homes to have degraded service. and there is that fact the many if not most cable systems are poorly maintained and typical lack competent technicians to troubleshoot intermittent problems. No, they really are total garbage whose time has come and gone!
@rajacable705 жыл бұрын
Ilke cable TV job
@rajacable705 жыл бұрын
I just love cable TV work, can you help me
@joseph_b3194 жыл бұрын
You could have saved all of those steps by looking at pathtrak, dropping the tap plate then hitting the button inside the tap and then watch the noise drop on PT.
@Wav100013 жыл бұрын
Good method assuming you don’t have multiple layers of noise and have good cell coverage (to connect to PT). It’s always good to be able to know what you’re looking at on a meter.
@rajacable705 жыл бұрын
I like working with cable TV and I am looking for a new TV only job Can you help me You can join me on your team.