Productivity 1000 Series PLC Timer Instructions

  Рет қаралды 7,271

ACC Automation

ACC Automation

Күн бұрын

Пікірлер: 14
@last_name_ramos7525
@last_name_ramos7525 3 жыл бұрын
Why won’t my 1000 value show up after I typed it into the value section at the database?
@ACCautomation
@ACCautomation 3 жыл бұрын
Hi GroovyRamon X, When you are using the Data View. You must Edit the value and then send the edit to the Productivity. accautomation.ca/productivity-1000-series-plc-monitoring-and-testing-the-program/ This will show you how to use the edit. I hope this helps you out. Regards, Garry
@last_name_ramos7525
@last_name_ramos7525 3 жыл бұрын
Thank you Mr Garry. I will try that and let you know.
@HetanHawke
@HetanHawke 6 жыл бұрын
u r Mr a great teatcher in PLC .
@ACCautomation
@ACCautomation 6 жыл бұрын
Hi Hetan, Thank you for the comment. Regards, Garry😀
@brentbarnhart5827
@brentbarnhart5827 2 ай бұрын
HOw do you do a traditional LATCH?
@ACCautomation
@ACCautomation 2 ай бұрын
Here is a simple start / stop (LATCH) circuit. accautomation.ca/productivity-1000-series-plc-first-program/ You can also use the set and reset instructions. I hope this helps you out. Regards, Garry
@chossmedia
@chossmedia 5 жыл бұрын
what would Timer1 do if both Time Up and Time Down were on at the same time? Meaning switches 3 and 4 both on
@ACCautomation
@ACCautomation 5 жыл бұрын
Our first input (Switch3) will be the time up. When this is on the timer will time up at the time base rate we selected. The second input (Switch4) will be the time down. When this is on the timer will time down at the time base rate. When both time up and time down inputs are on at the same time the timer will not count. This is documented on the website at the following address: accautomation.ca/productivity-1000-series-plc-timer-instructions/ Regards, Garry
@peterwang1568
@peterwang1568 5 жыл бұрын
Garry can you change the preset value of the structure tag though an HMI interface or do we have to create a new tag for the preset value and done to be able to change it through an HMI interface?
@ACCautomation
@ACCautomation 5 жыл бұрын
Hi Peter, You can use the existing structure tag for the timer. In the tag database, a Modbus address can be assigned for the preset value. Regards, Garry
@baconsledge
@baconsledge 2 жыл бұрын
I have a P1-540 and the instructions and this video do a lousy job of explaining how the timers really work.
@ACCautomation
@ACCautomation 2 жыл бұрын
Hi Bob, What are you trying to do with the timers? What is your application and timing chart look like? Regards, Garry
@ACCautomation
@ACCautomation 2 жыл бұрын
This post may help in understanding timers. accautomation.ca/the-secret-of-using-timers/ Regards, Garry
Productivity 1000 Series PLC Contact and Coil Instructions
19:28
ACC Automation
Рет қаралды 7 М.
Productivity 2000 PLC Ladder Logic Timers
11:04
ACC Automation
Рет қаралды 1,5 М.
Nastya and balloon challenge
00:23
Nastya
Рет қаралды 50 МЛН
The FASTEST way to PASS SNACKS! #shorts #mingweirocks
00:36
mingweirocks
Рет қаралды 16 МЛН
Productivity 1000 Series PLC Numbering Systems and Tag Database
12:02
ACC Automation
Рет қаралды 4,5 М.
PLC Timer Programming for Beginners
10:44
RealPars
Рет қаралды 124 М.
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 912 М.
Productivity 2000 Series PLC First Program
18:07
ACC Automation
Рет қаралды 4 М.
Productivity 1000 Series PLC Data Logger
6:15
ACC Automation
Рет қаралды 4,2 М.
Beginners Guide To Programming An HMI From Automation Direct
16:06
ControlsFreak
Рет қаралды 10 М.
Basic PLC Instructions (Full Lecture)
33:09
Jim Pytel
Рет қаралды 717 М.
Productivity 2000 PLC Ladder Logic Contacts
12:41
ACC Automation
Рет қаралды 1,3 М.
CAN Bus Explained - A Simple Intro [v2.0 | 2021] 🌟
14:44
CSS Electronics
Рет қаралды 227 М.
Click PLC Drum Instruction Sequence
7:43
ACC Automation
Рет қаралды 18 М.