Napaka systematic mo talaga sir pag apporach sa problem. Thumbs up!
@leckyjake3 жыл бұрын
Thank you and sana meron ka din sayo na yung convinient ka sa ginagawa mo. Safe sailing
@melaniobenitez55274 ай бұрын
Good job lecky for showing your videos in trouble shooting of fault refrigwration vegetable room. remedy slonoid valve adjustment.
@__iam.zee_3 жыл бұрын
Your videos are the most simplified and well explained. Keep posting such. It has been a great practical knowledge booster for many of the youngsters like us😊👍🏻
@leckyjake3 жыл бұрын
Thank you very much. Next video is the modification of wiring diagram
@johncantrell6143 жыл бұрын
Thanks for sharing this refrigeration information, along with your electrical information as well! 🙂
@vietvu86598 ай бұрын
Very good video and explained. I am excited to see your next video on Provision refrigeration troubles. Thanks
@manubkrishnan Жыл бұрын
Thank you Jake... expecting more videos related to refrigeration and air condition....Thank you...😊
@arielcuaresma78782 жыл бұрын
Godbless po!,please keep posting such knowledge and ideas👍👍👍
@abhijithmohan60353 жыл бұрын
thank you for making very informative video -as you mentioned at the end waiting video regarding other problems facing on refrigeration ,keep doing very good work lecky
@leckyjake3 жыл бұрын
Thank you for the support
@geremeicaro1637 Жыл бұрын
Very informative sir thank you for sharing your expertise ingat lagi SA paglalayag God bless
@engrlavalava82323 жыл бұрын
Thank you for the knowledge. Keep it up!
@leckyjake3 жыл бұрын
Thank you for your support
@25denzil3 жыл бұрын
Your video cover much more than what institutes teach us. Awesome video 👌🏻
@findvoltage3 жыл бұрын
its up to you to research,. they teach you what you need to know the rest is up to you. your going to have to learn how to learn. you will have to start thinking for your self now, no one can teach you everything, no one!
@satyabratgaan4918 Жыл бұрын
Kindly it would be nice to elaborate on superheat thing. First of all if the system was running fine before this problem happened and there was no work done on the TXV of veg room . So why to solve the problem we have to open the TXV more . As we know it has been set by factory before it was fitted as per requirement of the system. That clearly says that TXV should automatically open more as per the operational requirement. That means opening pressure due to the bulb sensing is not sufficient to maintain the superheat. Though the action solved the problem but I feel if TXV is malfunctioning then it needs to be changed so that it maintains the temperature in the previous setting of the TXV.
@mtwithismail98017 ай бұрын
😊
@tylernorman254 ай бұрын
yes, i would suggest changing out the txv screen first. They get clogged often and buildup of ice immediately upon start up is a hint to this issue.
@muhammadansar_208411 ай бұрын
Good share from kabayan base on his experience faced on board ship recently as it also can advance to someone else knowledge about fridge system...😊
@jeynishjayaraj94163 жыл бұрын
I am studying for eto now... Urs video r very useful to me.. Thank u
@leckyjake3 жыл бұрын
Thank you for watching
@jaykesapalaran54342 жыл бұрын
Sir salamat Po sa mga idea ng mga troubleshooting.. ❤️Keep safe all
@jeomarhidalgo83003 жыл бұрын
Thank you sir lecky for another knowledgeable ideas.
@leckyjake3 жыл бұрын
Thank you for your good comments
@rajeshloganathan69103 жыл бұрын
Sir please keep on update more knowledge eto videos
@leckyjake3 жыл бұрын
Thank you for the support
@geonbuenvenida54452 жыл бұрын
Thankyou sir very informative .. seaferer din ako passenger vessel mag isa lang din po ako na reefer dito ... upload ka din sir sa trouble ng chiller compressor
@ethanlove5513 Жыл бұрын
As always excellent and informative video keep them coming. This is a common problem I’ve encountered this many times but the Chief just had me use hot water to break up the ice 🧊
@joselitomacapaz85212 жыл бұрын
thank to your sharing kabayan God keep bless you
@PracticalMECEngineStudy3 жыл бұрын
Very Nicely explained. I am excited to see your next video on Provision refrigeration troubles. Thanks
@emmanuelzamora11142 жыл бұрын
Good job sir jake kaya pala nag ice build up yung evaporator ng chiller dahil d wastong pagset yung TXV..lage po ako nanonood sa vlog nyu sir.sana palarin gaya nyu po.
@farhanfaisol64982 жыл бұрын
Thanks leaky Jake hope can hear more knowledge from you
@frankcloskey77892 жыл бұрын
This is the best Refrigeration field for a job. Excellent trouble shooting. 9/30/2022yr
@CruisingMaya3 жыл бұрын
Informative and on point- thanks for putting this together!
@fredsalter19153 жыл бұрын
What a cool job! Sailing the beautiful seas and keeping the vessel's systems in ship-shape!
@pjero20052 жыл бұрын
Only a guy that has never worked on sea can say that (marine engineer with 14 years expirience)
@fredsalter19152 жыл бұрын
@@pjero2005 Maybe true, but I still think Lecky Jake has an enviable job!
@16valve642 жыл бұрын
Thanks a lot for sharing your thoughts
@rupanjansaha4788 Жыл бұрын
Excellent,,
@bersajibuden16813 жыл бұрын
Thank you so much sir, stay safe always!!!!
@leckyjake3 жыл бұрын
Thank you
@monzurhasan35833 жыл бұрын
After wait is end 🥰🥰🥰
@leckyjake3 жыл бұрын
Thank you for your support
@chinesenightbreaker02fl.h799 ай бұрын
Salamat Po!Keep in mind my friend that as ship's ETO to deal with refrigerators and A/C IS NOT YOUR OBLIGATION OR JOB!!!Where is your engineers?Scratching the ases in ECR perhaps?Let them do their job where a refrigeration systems is one of their duties!
@dmitriibugayov69759 ай бұрын
It depends on the situation on board. Sometimes you have engineers who are so helpless... Better to do it by yourself to be sure that job is done and nobody gives you extra problems when doing some shit there. Sometimes you knowleges much better than your team in this area, and if people on board are good- better to help them) But if there are lazy stupid motherfuckers- of course send them to do their job))😅
@gurbirsingh8232 Жыл бұрын
Nice video sir thanks
@sumeshlalsurendran21932 жыл бұрын
Dear Jake, Icing on evaporator ,so you reduced the super heat by turning it into counter clock wise. Actually here, superheat was "increased". I believe it's done after turning the adjustment screw to "clock wise ."
@bt96042 жыл бұрын
Are u eto
@NisanthVpillaiIndia Жыл бұрын
Superheat is reduced by turning anticlockwise.
@ronkurey88402 жыл бұрын
Excellent!
@niky71976 ай бұрын
Super valuable Sir . Same problem in my meat room . I will try this method
@imranshaheen81393 жыл бұрын
Tnx for sharing,,,,
@leckyjake3 жыл бұрын
Thanks for watching
@ekojuniharyanto655 Жыл бұрын
Normaly expantion valve how many turn Jack , ❤❤❤
@syedbasheer82103 жыл бұрын
Great job✅
@joeybocabel78973 жыл бұрын
Nice video lecky 👍🏻
@leckyjake3 жыл бұрын
Thank you for the support
@MaxKharevsky3 ай бұрын
Thanks ❤
@TJ-bi8hf3 жыл бұрын
very informative Elec. thank you
@coldstorage36163 жыл бұрын
Thank You po Sir Leckyjake👍🙏☺️
@leckyjake3 жыл бұрын
👍👍👍
@zanegraydulnuan37543 жыл бұрын
Nice very informative video. Just piece of advice much better and safer to use water in defrosting expansion valve.
@nestormolato115811 ай бұрын
Hi Elect, thank you for the video, just curious if the vegetable room have evaporator pressure regulator since the piping is interconnected with meat and fish freezer? Means both suction pressure are the same. Provision compressors on this video is Bitzer / Sabroe open type.
@thivankagamage2630 Жыл бұрын
Hi,, thanks for the vedio which is very usefull.. Lecky,, I have a same trouble which is Ice deposit on expansion valve. I have cleaned inside filter and run the system. But trouble is remaining still. Unfortunately , I dont have a spare one onboard ...😒
@gealje94333 жыл бұрын
Thank you for this video. I still have a question, how do you know the level of the refrigerent is okay? And how do you assess the evaporators on your meat and fish room are still good?
@leckyjake3 жыл бұрын
For the level, check your pressures, and on the sight glass you will see the level. For the evap of meat room and fish room, no ice to thaw on the grill and the temperature is in range.
@SCAMATICS7773 жыл бұрын
So is the same compressor running all 3 rooms? I was curious on refrigerant level as well but did not see any gauge readings. Nice video. I would like to see a little more testing before your determination. Thank you. Im about to get certified but lack experience because of covid schooling turned to online.
@findvoltage3 жыл бұрын
@@SCAMATICS777 Its the same as a multi split system AC. no difference, dont confuse yourself with labels, look at what they are, just a pump cycle with switches and relays, oh and mini switches and relays (PCB's). easy as pie, a trained money could do this work. im living proof.
@findvoltage3 жыл бұрын
Super heat and subcooling is hoew to tune a system, go look it up. you will need to know what they mean if your going for a jab,... i mean job.
@ivanfmartinezm Жыл бұрын
You can see the refrigerant level on the sightglass paced on the condenser unit wich should be at middle the liquid level. Furthermore the temperature from fish and meat room are both in range -18 °C, also you can see the refrigerante gauge from low pressure the indication should be about 1 bar or higher with one of the chamber are working, i hope this make sense and can help you.
@chrishye Жыл бұрын
Our Blaster Freezer room (-40C) frequently have icing on the floor (we have proper door with gasket and curtain strips but hot air from outside or products when we push the hot product into the room to freeze them). Our floor has changed to use PU to reduce icing and anti-slip yet still have this issue... do you have any suggestions?
@hiteshraibagkar77663 жыл бұрын
Very Nice . Thank you.
@sohaghossain64692 жыл бұрын
Thank you so much for your information
@HaydeeVelasco-d9w11 ай бұрын
Sir good job Sana mag labas ka din ng video kung paano ang adjustment ng txv sa ice machine tnx sir
@jaykesapalaran54342 жыл бұрын
Sir sana next video Po charging of refrigerant..at ano procedure safety ways
@aiahamadumbayo74752 жыл бұрын
Thanks very much.
@frankcloskey77893 жыл бұрын
Excellent Trouble shooting a superheat adjust ment needed. 10/30 2021
@ayhamshbat27333 жыл бұрын
Hi thx u for the content , I got confused when u lower the super heat the ice will be melted? Isn't increasing the heat will melt the ice
@syarifudin_bwx39042 жыл бұрын
Nice bro, thank u for the knowledge
@arielsaemon61703 жыл бұрын
Thanks for your video sir. It's very helpfull 🙏.
@NataneAlves53 жыл бұрын
Thanks for the video!!!
@akil78255 ай бұрын
Hi sir..one issue on our E/R package AC unit... When we switch on the system suction pressure going negative 😢
@JunaidAli-qr3rr5 ай бұрын
Some of ur solenoid valve is not going to onn bro
@Lizard_DroneX2 жыл бұрын
You still sailing? did you get your refeer endorsement?
@pauljohnson8113 жыл бұрын
Thankyou sir...very helpful ❤️
@leckyjake3 жыл бұрын
Thanks for the support
@reyencels17493 жыл бұрын
Slmat sir lecky jake
@wasimedoo7994 Жыл бұрын
Very good job 👍
@mrvoyageratseaandland81003 жыл бұрын
Good one sir. Sir how did u adjusting the manual txv value did there is any specific adjustment value is there ah sir
@ebfsystem Жыл бұрын
I'll love to be side by side with you while you do the troubleshooting,,, I'll be asking 2 million questions 😂😂
@ccoairconservicescris16052 жыл бұрын
Keep posting sir tnx
@joseantoniolobera27953 жыл бұрын
A Lot of tHanks for the vídeo
@winefredcaluser50142 жыл бұрын
Hi! Lecky Jake good day to you. Elect I have a question maybe you can help me. My question is, what is the common caused or the problem of the Cylinder head and the line in Marine Refrigeration Icing?
@MrAviraabraham3 жыл бұрын
Nice videos, which ships are you sailing on ?
@naylinhan57952 жыл бұрын
how about back pressure control valve on the evaporator out let? does it function correctly? need adjustment. i guess.
@ashimkumaradhikari49022 жыл бұрын
Thank you. What will be the problem if i get ice only on expansion valve but not on Evaporator.
@danteybanez84952 жыл бұрын
Hello leckay goo day! may tanong lang po ako sa reefer provision namin ang MEAT ROOM hindi mag auto start...pero mag auto stop naman? Pls. share your a good idea..
@tomoliver84983 жыл бұрын
It simply needed an off cycle defrost timer installed or replaced. Or may have been trying to run it too cold. I doubt the txv needed adjusting.
@leckyjake3 жыл бұрын
It is actually a vegetable room so no defrost for the system
@persimonsen87923 жыл бұрын
@@leckyjake How do you keep 4C in there without defrost ? In a humid enviroment in a kitchen and especially on a ship at sea.
@marinemaza2452 жыл бұрын
Very good vedio ..after watching yr vedio thing came in my mind Is let me first subscribe then go for next😂
@ksantostitanos3 жыл бұрын
Wait for this video
@leckyjake3 жыл бұрын
Thank you for your support
@ksantostitanos3 жыл бұрын
@@leckyjake thanh You for this perfect video!!! Really!
@lecmen473 жыл бұрын
by freezing, possibility, thermostat, coolant, or some leak in ducts etc.
@reygenoguin81103 жыл бұрын
Sir good day , what pressure of refregirant for low and high pressure can you say that your refrigerant is enough ??thankyou
@kennethlobo44203 жыл бұрын
I liked the video.,yes there is a great responsibility to keep the system going,out at sea.Water is the superheat U maintain on this cooler? In future show us the superheat setting
@kitioneturaganivalu50383 жыл бұрын
trial and error
@kennethlobo44203 жыл бұрын
Okay
@vijayakrishnankogulan77383 жыл бұрын
Super thank you sir
@jeomarhidalgo83003 жыл бұрын
Good day sir lecky may tanung po ako tungkol sa MGPS nmin dito, kasi may voltahi nman papuntang cells nya ang problima walang current reading sa or no current indicaes at ammeter. Thank you sir lecky isa narin po akng electrician sa barko dito sa cebu interisland lang muna sir.
@kevindomingo59033 жыл бұрын
Check condition of anode/cathode
@ShahbazAlam-tr6cn3 жыл бұрын
After long time sir
@leckyjake3 жыл бұрын
Just arrived in the port today
@jimmyestomata5172 жыл бұрын
Thank you sir
@jhonpaulnatividad61202 жыл бұрын
nice galing
@johnangelodelacruz64313 жыл бұрын
What is the range for normal refrigerant level sir in your system?
@leckyjake3 жыл бұрын
Actually I use the pressures as the baseline for any refrigeration system and then level in the sight glass is just secondary
@johnangelodelacruz64313 жыл бұрын
@@leckyjake so what would be the normal refrigerant pressures level for high side and low side in your system sir?
@amantek35452 жыл бұрын
@@johnangelodelacruz6431 pressures vary with the refrigerant in the system
@CrisDoguito4 ай бұрын
what is the suction pressure and discharge
@michaelatos140 Жыл бұрын
Sir saan mo po nabili magnet tool mo 3:45
@jeffreycidro9432 жыл бұрын
wher which turn direction in that case sir...the ice build up problem,,,1 full turn left or right?
@mehmetguver93223 жыл бұрын
I talk about you new generation eto officers to watch your videos :)
@leckyjake3 жыл бұрын
Thank you very much for your wonderful comment. Very much appreciated
@martvofficialchannel4208 Жыл бұрын
Salamat sa idea master
@rhedeemescasinas99713 жыл бұрын
Sir. Good Day! The main reason of Icing on the system is low flow of Refrigerant in the System right?? Thank you!
@leckyjake3 жыл бұрын
I lower the superheat by reducing the spring tension of the TXV.
@matthiaskleinjan29973 жыл бұрын
Yeah low pressure. Because the TEV doesn't let enough refrigerant through the pressure will drop and the refrigerant will start to evaporate at low temperatures.
@Gary-ts6dh2 жыл бұрын
5:36 - That was one-half turn.
@marklaman14983 жыл бұрын
Nakasubscribe na bro...
@leckyjake3 жыл бұрын
Thanks
@temoteoalmendras36003 жыл бұрын
Salamat lecky
@kamaltandel14582 жыл бұрын
How we know we increased or decreased superheat by turning the screw.is there any marking for clock wise and anticlock wise for increased or decreased the superheat
@imrankazi2759 Жыл бұрын
Gmg sir saw ur vidio on no spare of txv.how to make. And troubleshooting for icing on evaporator.thanx Best regards Imran kazi 2nd engineer Teekay tanker ship mgmt.
@yongtamz11943 жыл бұрын
Thanks for this video sir more power to you,anyway sir where you can bought your tool permanent magnet it is so nice?
@jahedkn3 ай бұрын
Due to high superheat this prblm occured. So u lower the superheat prblm solved. I see u anticlockwise valve turn that mean u reduce the flow of refrigent? Normally we seen all valve anticlockwise mean open the valve.
@ShubhamSingh-bn3vx3 жыл бұрын
I m on board as a trainee, keep waits ur video on board too
@leckyjake3 жыл бұрын
Videos will be uploaded every weekend.
@tandelgaurav5320 Жыл бұрын
Sir what's the use of heat exchanger?
@antonyzairaz7627 Жыл бұрын
Could you please explain the fish room tem. Not coming more then -15 dig set tem. Is -18 dig. Meat room mainten 18dig.
@AjeetSingh-iu9wl3 жыл бұрын
Make Video How to read Ckt Diagram it will help in Future Cadet
@leckyjake3 жыл бұрын
Next video is all about wiring diagram and modifications
@vigneshkrvd3 жыл бұрын
@@leckyjake yes sir... Thank you... We are waiting for the next video