PT & INSULATION RESISTANCE TEST OF POTENTIAL TRANSFORMER: MEGGERING OF PT:WHAT IS PT & INSULATION

  Рет қаралды 5,766

Electrical Passionate

Electrical Passionate

Күн бұрын

Dear Viewers,Please Watch the Video. Thank You.
pt megger test,Potential Transformer meggering,IR test of PT,Process of meggering PT,pt test,how to check pt,what is pt in electrical,insulation test of pt

Пікірлер: 18
@amitpagare5946
@amitpagare5946 Ай бұрын
Very informative video 🙏🙏🙏🙏
@electricalpassionate
@electricalpassionate Ай бұрын
You are welcome. Thank you for watching the video. Please watch other videos on this channel. ❤
@umadevi6754
@umadevi6754 Ай бұрын
Super sir.. your video thank you
@electricalpassionate
@electricalpassionate Ай бұрын
You are welcome. Please keep watching. Thanks❤
@dodiyasanjay7777
@dodiyasanjay7777 Жыл бұрын
Battery impedance test video
@electricalpassionate
@electricalpassionate Жыл бұрын
You are welcome. I am trying.Please keep watching. Thank you.
@dodiyasanjay7777
@dodiyasanjay7777 Жыл бұрын
@@electricalpassionate ok sir
@konstantinostheo2911
@konstantinostheo2911 9 ай бұрын
The n terminal usually has thin wire with poor insulation, if we apply 5kV at HV terminal while we perform the primary to body or primary to sec test wont we stress or damage the insulation of wire of N terminal?
@electricalpassionate
@electricalpassionate 9 ай бұрын
you are most welcome. Sufficient insulation is provided at Primary side to withstand 5KV voltage. When the fuse at primary side neutral opened accidentally then full primary voltage appeared at the N- terminal. Thank you for watching the video and commenting on it.
@konstantinostheo2911
@konstantinostheo2911 9 ай бұрын
⁠@@electricalpassionatebut we don’t put fuse in neutral at primary side, we install fuses at secondary windings only.I mean the wire that ends at N terminal on the secondary box has small cross sectional area, so can it withstand the 5kv dc volt on insulation resistance test?
@electricalpassionate
@electricalpassionate 9 ай бұрын
@@konstantinostheo2911 On that case, you must have seen a Link and the Link is connected with the body/tank. When you will perform the IR test you have to open that link. Otherwise, you will get no result. Again a 132 KV or 33KV PT has provided sufficient insulation and you can use 5KV for testing the PT easily.So far as the Secondary winding is concerned, you must use 500Volt. Thank you.
@ElectricalDot8704
@ElectricalDot8704 3 ай бұрын
Sir , in 132kV/110V PT what should be the insulation resistance value?? Primary to earh , primary to core-1 , core-1 to earth????.... please reply
@electricalpassionate
@electricalpassionate 3 ай бұрын
You are welcome. So far as my knowledge is concerned there is no effective thumb rule for calculation of IR value. For a new 132KV PT it should be as high as possible. But for older one it should be how? In few cases IR values of such PT were between pry. to earth 40 to 50 mega ohm and Secy. to Earth were only, 5 to 10 megaohm.And they were running smoothly. Experience will act accordingly. Thank you.
@ElectricalDot8704
@ElectricalDot8704 3 ай бұрын
Thank you so much sir, today I tested 132kV/110V CVT which is made by Alstom and manufacturing year is 2012. and it is not charged so far from 2012. the insulation resistance we obtain as primary to earth - 374 Giga ohm, primary to core 1 -112 Giga ohm, primary to core 2 -38.4 Gohm, core 1 to earth is 2.14 Giga ohm, core 2 to earth -5.7 Gohm, core 1 to core 2.23 Gohm............. Sir how can I make a conclusion of this?? Please reply...
@electricalpassionate
@electricalpassionate 3 ай бұрын
@@ElectricalDot8704 IR values are good enough.If other parameters are good then it can be put into service. Sorry for belated reply. Thank you.
@ElectricalDot8704
@ElectricalDot8704 3 ай бұрын
@@electricalpassionate thank you sir 🙏
@user-jg7bb3wi8h
@user-jg7bb3wi8h 6 ай бұрын
Could you pls add (slid/pdf) file for u. Lecture....
@electricalpassionate
@electricalpassionate 6 ай бұрын
You are welcome. Sorry. No such provision.Thanks.
Current Transformer vs Voltage Transformer : What’s the Difference ? TheElectricalGuy
12:32
6,600 VOLTS ALTERNATOR INSULATION RESISTANCE CHECK
11:58
leckyjake
Рет қаралды 47 М.
Scary Teacher 3D Nick Troll Squid Game in Brush Teeth White or Black Challenge #shorts
00:47
Looks realistic #tiktok
00:22
Анастасия Тарасова
Рет қаралды 98 МЛН
Fluke Insulation Tester In Action, (AKA Megger)
4:19
ElectricianToolDeals
Рет қаралды 17 М.
Mistakes of Insulation Resistance Test | Correct Method of Megger Test
6:36
Electrical lectures
Рет қаралды 24 М.
VT ratio test 13.8kv by CPC100
9:04
Power System Engineering Solution (PSES)
Рет қаралды 13 М.
What does "impedance matching" actually look like? (electricity waves)
17:08
What is a CT Burden ? Explained | TheElectricalGuy
11:59
Gaurav J - TheElectricalGuy
Рет қаралды 14 М.
Important Current Transformer Parameters | Quick Guide | TheElectricalGuy
13:42
Gaurav J - TheElectricalGuy
Рет қаралды 23 М.
IR and WR test क्यू किया जाता हे?
12:14
Gyaan ELECTRICAL
Рет қаралды 32 М.
Stability test of Transformer || Hindi
23:01
Insight Tecs
Рет қаралды 54 М.