No video

Pump and System Curves

  Рет қаралды 48,370

Postcard Professor

Postcard Professor

Күн бұрын

Пікірлер: 48
@virtualpilot2235
@virtualpilot2235 Жыл бұрын
I've saved this video in a playlist and I watch it everytime before my fluid exams. Must say this is an awesome piece of work here.
@SonicGirl4Ever
@SonicGirl4Ever 3 жыл бұрын
I'm studying for my Water Resources PE and, having been out of uni for 4 years and never having to touch a pump in my career, this is exactly the refresher I needed. Thanks!
@tacicub
@tacicub 3 жыл бұрын
This is excellent! Your instructions are perfect and easy to follow. Thank you!
@PostcardProfessor
@PostcardProfessor 3 жыл бұрын
Glad it was helpful!
@kkguptahp
@kkguptahp 3 жыл бұрын
Best video solves all points with clarity 👌🏼👌🏼
@thatolehula4296
@thatolehula4296 3 жыл бұрын
best video om the topic. been studying this for momths amd the dude just gave it all to me in less than 20 minutes ✌😅. great video.
@asifalikalody1722
@asifalikalody1722 4 жыл бұрын
I tried many ways to better understand TDH concept. Finally This video helped me.Thank you very much sir. Subscribed👍
@PostcardProfessor
@PostcardProfessor 4 жыл бұрын
Thanks for the kind words!
@benklassen77
@benklassen77 4 жыл бұрын
The best video I could find on this topic. Subscribed.
@arinahurgoi3031
@arinahurgoi3031 3 жыл бұрын
literally couldnt agree more
@muhammadreza572
@muhammadreza572 3 жыл бұрын
It can't be better than this.thanks for your work
@chrisgraham5963
@chrisgraham5963 2 жыл бұрын
Amazing explanation! Thank you!!
@kupo871
@kupo871 4 жыл бұрын
Better than my fluids class! Thank you!
@letsgosurfingdude
@letsgosurfingdude Жыл бұрын
Thanks! Awesome video.
@Anonymous-fj3vi
@Anonymous-fj3vi 3 ай бұрын
best explanation
@1daniel2678
@1daniel2678 4 жыл бұрын
Great video, thanks a lot!
@lex5740
@lex5740 16 күн бұрын
Bro that what I do when selecting equivalent pump from the existing which isn't in good condition anymore on site
@winexhd9373
@winexhd9373 4 жыл бұрын
Thank you!
@karthikp2650
@karthikp2650 2 жыл бұрын
Thank you friend
@fredrickagyemang9395
@fredrickagyemang9395 7 ай бұрын
Master you are too good❤
@fredrickagyemang9395
@fredrickagyemang9395 7 ай бұрын
15:29 15:29
@thandonxumalo1278
@thandonxumalo1278 3 жыл бұрын
Sooo informative! Thank you!
@amirrowhani8101
@amirrowhani8101 2 жыл бұрын
Excellent!
@aliabdulkadhumali243
@aliabdulkadhumali243 4 жыл бұрын
smart! thank u
@boomfly9543
@boomfly9543 2 жыл бұрын
I would recommend to use z for elevation not another h
@zumazumame8852
@zumazumame8852 7 ай бұрын
Sir... could you explain, why hpump equation sudently become (1+f(L/D))... why vB^2/2g was replaced by 1?
@mirageleung1575
@mirageleung1575 11 ай бұрын
Does the arch above hb matter when calculating hb? e,g, what if the arch was far higher?
@dheyaalgallaf6060
@dheyaalgallaf6060 2 жыл бұрын
i am slightly confused, if engineering company design a centrifugal pump for viscosity other than water (i.e. other fluid) how to link this pump with a vendor pump tested by water only!
@nhaz652
@nhaz652 Жыл бұрын
is it necessary to draw the parobolic line each time?
@26goldnugge
@26goldnugge 3 жыл бұрын
If you have a hose going up a hill as showed in your picture would that produce minor losses?
@santoshkafley5772
@santoshkafley5772 3 жыл бұрын
how did you guess Hp and correspondence value of Q? : Is there mathematics formula?
@Shah8086A
@Shah8086A 3 жыл бұрын
I think Q&H should be determined by the application; then find the pump gives the good efficiency in the region. Not the other way around.
@noopurpancholi4497
@noopurpancholi4497 3 жыл бұрын
can we predict VSD or DOL type of pump by this cure?
@brendangolledge8312
@brendangolledge8312 2 жыл бұрын
Is there a theoretical derivation for the shape of a pump curve? I guessed maybe a centrifugal pump imparts constant energy per unit mass to whatever fluid passes through it. Then you'd get E = constant (for any given fluid density) = P + (1/2)dv^2 (d is density), or h = E/(dg) - Q^2/(2gA^2). This has the shape of an upside down parabola (right basic shape), but when I try to compare it to real pump curves, the real curves turn downwards something on the order of 100 times faster than my theoretical model. Do you know why this might be? Am I making some unit conversion error, or is the whole thought process just wrong? If the real pump curves turned down something like 10-50% faster than the theoretical one, I'd be happy, because I guess the pump doesn't conserve energy perfectly and it doesn't have the same efficiency at all operating ranges. But getting a result 10,000% different than the theory is unsatisfying.
@dheyaalgallaf6060
@dheyaalgallaf6060 2 жыл бұрын
Why not taking point B on surface of up tank?
@cts3218
@cts3218 3 жыл бұрын
1. I can't understand why the head of pump will be larger the head of B after increasing the Q? 2. Besides, why the connection point of the system curve and the pump curve is the operating point? Why don't we adjust the operating point along the pump curve and choose the point nearest to the 0.82????
@abdulrehmankhan4860
@abdulrehmankhan4860 3 жыл бұрын
can we find system curve for closed system ???
@sadhomie8966
@sadhomie8966 3 жыл бұрын
What is the unit of pump head?
@carlosnoriega7296
@carlosnoriega7296 4 жыл бұрын
5:32 souldn't the equation have another term equal to (v^2)/2g which corresponds to the hydraulic losses at the output of the pipe? Having something like Hb=Zb+ hL being hL the primary hadraulic losses.
@PostcardProfessor
@PostcardProfessor 4 жыл бұрын
That’s the “1” that’s added to f L/D. We can either look at the surface of the water, in which case those are hydraulic losses, or at the exit of the pipe, in which case it’s kinetic energy.
@narrm
@narrm 2 жыл бұрын
Dear sir in some other videos , they consider velosity head as helping the pump so they subtract its value from the total head the pump should give to the fluid
@karimkrimou2568
@karimkrimou2568 4 жыл бұрын
I have two questions 1- why is the velocity in the friction head is the same as the velocity in point b? 2- Is the velocity in point B the same in the impeller? If so, why?
@PostcardProfessor
@PostcardProfessor 4 жыл бұрын
1 - The friction head is due to the velocity in the pipe. At point B, the assumption is that the diameter of the pipe is the same as everywhere else. Since the diameter is the same, and flow rate has to be the same, we know that velocity is the same. 2 - The velocity immediately before and after the pump is the same as point B. However, inside the pump, things are a lot more complicated, as the impeller is causing a lot of rotational movement while the area is also changing. At this level, we don't try to look too deeply into what's happening inside the pump. That's what the curve is for!
@karimkrimou2568
@karimkrimou2568 4 жыл бұрын
@@PostcardProfessor so I guessed right. Thanks a lot
@craig78
@craig78 2 жыл бұрын
I remember putting the energy in to friction. Then I remembered fuck it.
Turbomachinery Similarity Laws
13:41
Postcard Professor
Рет қаралды 6 М.
Pump Curve vs System Curve - Example Problem
13:13
Brian Bernard
Рет қаралды 2,9 М.
КАКУЮ ДВЕРЬ ВЫБРАТЬ? 😂 #Shorts
00:45
НУБАСТЕР
Рет қаралды 3 МЛН
OMG what happened??😳 filaretiki family✨ #social
01:00
Filaretiki
Рет қаралды 12 МЛН
Logo Matching Challenge with Alfredo Larin Family! 👍
00:36
BigSchool
Рет қаралды 20 МЛН
Fluid Mechanics: Centrifugal Pump Characteristics (21 of 34)
59:05
CPPMechEngTutorials
Рет қаралды 255 М.
How to Read a System Curve: Simple Explanation
9:56
R.C. Worst & Co., Inc.
Рет қаралды 41 М.
Fluid Mechanics: Series and Parallel Pumps (22 of 34)
40:33
CPPMechEngTutorials
Рет қаралды 88 М.
Pumps - Operating Point
15:45
Carl Wassgren
Рет қаралды 10 М.
Choices from Pump Curve
11:48
MECH 241 - Fluid Mechanics I
Рет қаралды 68 М.
How to Read Pump Chart and Select Pump
16:15
MEP Academy
Рет қаралды 33 М.
Pump Curve and System Curve Explained
1:03:42
HVAC TV
Рет қаралды 10 М.
Want to understand pumps? Don't start with pump curves.
7:43
Process with Pat
Рет қаралды 23 М.
Fan Curves Master Class with Greenheck
43:43
Holden and Associates
Рет қаралды 19 М.
Combined Performance
6:55
MECH 241 - Fluid Mechanics I
Рет қаралды 24 М.
КАКУЮ ДВЕРЬ ВЫБРАТЬ? 😂 #Shorts
00:45
НУБАСТЕР
Рет қаралды 3 МЛН