This was very informative, have been looking to know about the same kind of system out of curiosity.
@PrimeBlack-l4u8 ай бұрын
jo jo dhruv rathii ke video se aye hai like kare
@SNAPPERTBK19903 жыл бұрын
This has very low COP vs Heat Pumps. We should pair Heat Pump ODU heatpipe and put into the ground in a large circuit. This could utilize Geothermal heat exchange and will give max SEER and COPs than any system in the world! SEERs of 25+ can be achieved pretty easily. As Ground always has 5-10* temperature difference than air load will be very less.
@observingrogue76528 ай бұрын
I can picture this also being used to heat homes during winter. But beware of pipes & equipment being damaged if the water is ever allowed to become ice. The expansion of ice, can even rip metal. This is why car cooling systems need antifreeze.
@eugeneleroux18423 жыл бұрын
Thank you for a stimulating presentation. Although you addressed the operating costs, I wonder what the capital costs would look like ?
@blazor9072 жыл бұрын
The same as floor heating I would suspect. However A radiant barrier in combination with the radiant cooling would probably be a legendary cooling system for hot climates!
@chandrashekharkotekar84539 ай бұрын
If those coils are placed on the ceiling or on the wall then water droplets will drop all over the room. If we decide to cover the roof with something then this cooling will be less effective. If coils are on the floor then also we have to cover them, otherwise we won't be able to walk.
@tomato33473 жыл бұрын
great explanation
@GGN-923 жыл бұрын
Thanks for the explanations.
@heisenbugz9 ай бұрын
Isn't humidity and condensation the main reason currently hydronic heating installations aren't used for cooling?
@ABU-lz2sh Жыл бұрын
Most top heavy method of cooling
@payanshumeshram7911 Жыл бұрын
Thank you so much, this video is very beneficial . Can you please make more videos on this topic
@AngelLestat25 жыл бұрын
what happen if you use just wall cooling and wall heating for summer, using wall cooling it may be possible to condense the water falling vertically to a collector and you avoid the dehumidification unit which it would cost more than a simple air condition unit that do both things (dry and cool).
@brighttooth35928 ай бұрын
Thank you
@balaramkantipudi37284 жыл бұрын
nice info, btw which one is better in wall, ceiling,floor
@unicornofthought Жыл бұрын
ceiling. radiation transfer is unimpeded, whereas the floor might have rugs, furniture, etc.
@freddybell8328 Жыл бұрын
@@unicornofthoughtWhat about a system for heating though?
@unicornofthought Жыл бұрын
@@freddybell8328 same system. warm fluid is circulated for heating.
@NotionalTarget7 ай бұрын
What happens if a leak develops within the piping inside the wall or floor or ceiling?
@zeroceiling5 ай бұрын
This is the issue with ductless air-conditioning systems we use today!.
@MikeTrieu2 жыл бұрын
I don't get why the radiant heat exchange loops have all those 90° bends. Wouldn't it make much more sense to have a bunch of coiled loops to maximize coolant flow? Otherwise, you're going to have immense head pressure.
@freddybell8328 Жыл бұрын
Probably less material usage
@rahulk26339 ай бұрын
Wouldn't that increase thickness many folds and they could just use u bends instead of L bends
@sherifnabil502 жыл бұрын
The question is how are you going to produce the chilled water???
@chrisgeary46246 ай бұрын
Heat pump
@rameshagrawal38158 ай бұрын
Ac se Mahenga system 🤯
@kangan834 жыл бұрын
THANK YOU, this has been very informative. My one query do we need to install only one kind of system on the ceiling and or it can be installed either on floor / wall / ceiling? How do we decide the module, what is the calculation used here, asking out of curiosity.
@blazor9072 жыл бұрын
It's similar to floor heating, but on the ceiling. Remember if your water is cooled to 20C and the room is 30C, then the radiant heat is lower effectively cooling objects in the room that have high emissivity.
@ImranKhan-kf3lj8 ай бұрын
After dhruv rathee video
@kuietjunkie93873 жыл бұрын
Why radiant cooling is advertised to take care of ALL indoor air problems, including ventilation and air quality? It does nothing to ventilation, only to temperature. You can still have stifled air if your windows are closed with such setup.
@AnnoyedDriftwood-xc2rm10 ай бұрын
🎉
@IftikharR8 ай бұрын
Who came here after watching dhruv rathee video
@alyonarozhkovskaya98024 жыл бұрын
Интересно! Кто-нибудь устанавливал такую систему в России в частном доме? Интересует мнение клиентов по прошествии минимум года.
@joecox99585 жыл бұрын
chiller is 2X expensive then aircon
@IandiBoats5 жыл бұрын
You could dig shallow Wells where the temperature is 9 to 14 degrees c. A simple pex loop in the floor could result in a 5 to 7 degree lower room temp.