Funny story that happened years ago as a junior tech going on my on service/maintenance by myself. Doing PM work for convenient store, thought I would take the extra step of washing this really impacted self contained drink reach in. Decided to blow it out not realizing the amount of dust and ended up clouding up the whole store before I knew it. good times learning hahaha
@heavydiesel2 жыл бұрын
I did once braze up a leak like that for a customer that was closing their business in a months time. Cut the pipe off flush with the compressor, cleaned all the paint off and made the hole a bit bigger and silver soldered it, had a lot of wet rags on the compressor and nitrogen flowing to try and keep the heat away from the windings. Told them it was kill or cure and luckily it worked!
@sterlingarcher462 жыл бұрын
Standard job for HD , you da man blud ! 👍
@THESNAKE82 жыл бұрын
yessss! HD and uncle Dave are absolutely my favorite hvac/r KZbinrs
@farashvac3 ай бұрын
Why silver solder brudda ? Works better ?
@johnbell69562 жыл бұрын
Making giant messes, that I do not have to clean up, is one of my favorite things about refrigeration repair. Nice job.
@garyglenn14452 жыл бұрын
That coil brush is hammered...My brushes look just like it . But we just keep on using em till there down to the stub!!!!lol great job brother as always!!!
@bottlecapn95932 жыл бұрын
You da f🤘ckin man, thanks for always throwing out the coolest realist HVAC/R flicks on the tubes ❄️ 🔥 💧 takes a minute out in the real world to do the job right
@fredflintstone80482 жыл бұрын
Never saw an anodized coil either. Thanks for the update on the Sunjoe.. POS... Got it.
@lawnmoose2 жыл бұрын
Those Safari vans are perfect for service work. Nice job.
@jochemsluis88342 жыл бұрын
I have repaired the suction line by cleaning it back a sleeving 1/2 copper over it and brazing to the compressor. Best option is to replace of course but at a pinch I have done it and last as copper won't rust out.
@RP-mt6bp Жыл бұрын
Thank you for this video. I agree with compressor replacement decision. The moisture, that this compressor has pooled in for a while, has already damaged the quality of the oil in the system, and it became acidic which is destructive to the compressor windings. Besides, the water vaporizer coil, "the condensate loop" in the condensate pan, was also heavily corroded, and sooner or later, it would have chewed a hole (in that coil). Therefore, both jobs can be done on the same time; easier to replace this coil with the compressor out of the way. Kind regards, Arpi
@scotts41252 жыл бұрын
In the past when I tried to save money it always cost me double. Now I buy once cry once. You shelled out for the Sunjoe now you have to buy the first choice. It's always like this it seems. Trust me I have been bit by the same thinking too many times.
@prothermal_refrigerationHVAC4 ай бұрын
use same washer, broke this pipe too and installed flexible hose(clear braded) and connected with existing hose via reducer and burb connector. love this pump. battery last forever, ideal for minisplits undoors cleaning and reach in condensers cleaning.
@sterlingarcher462 жыл бұрын
Nice one Sir Davros 👍 I like the hand pump sprayer but my only beef is that they don't like hot water.
@CDX8252 жыл бұрын
That's funny when you said danfoss my first thought was leaking at the compressor connection.
@rossflores43942 жыл бұрын
Multiple affender to the max .Great content Dave. Thanks.
@scottk06232 жыл бұрын
Nice find Dave, hope you video the repair too.
@robertv44422 жыл бұрын
Thanks for providing such excellent support to my favorite spot on earth. SARA LOVES YOU!
@chrisbivens54102 жыл бұрын
🎶 back to the H-10…it never lets me down 🎶
@hvacrnortheastern21102 жыл бұрын
Great job Dave when you got that pump sprayer l look up the reviews they had same problem that you have with sprayer.Look at Goodway CC-JR great compact sprayer $$$ it a great sprayer.
@christopherlucas6209 Жыл бұрын
Good troubleshooting video!
@icecoldfridgy17292 жыл бұрын
Get a little handheld steamer. Melts the ice really quickly, and has the benefit of not adding much in the way of water.
@vinnyp162 жыл бұрын
Thanks for a great video super tech lol 🤣🤣🤣. Thanks for everything Dave has learned so much from the videos .
@NorCal-refrigeration2 жыл бұрын
Thank you for watching
@captainkirk77022 жыл бұрын
Came across those by the tons, I think now when you get a new one it’s built like a Copeland does it,at the suction port it’s copper now. As soon as you opened it up and seen the txt I thought it was the leaky danfoss compressor. Then you led me astray only to return to the compressor.🤣
@jasonjohnsonHVAC2 жыл бұрын
Been missing some of your videos...apologize for that.....been a hot and busy summer here in Austin....catching up on videos I've missed
@NorCal-refrigeration2 жыл бұрын
Thanks for watching
@danwittels55422 жыл бұрын
Excellent repair video! I'm diggin' that anodized coil, never seen one before.
@harrydickson45752 жыл бұрын
Awesome job 👍👍👍
@macbong012 жыл бұрын
its cause the insulation is all the way up to the compressor. I always cut it before the compressor so it doesnt rust. same with the rotor locks.
@kevinpoore56262 жыл бұрын
I see you're back to work I hope you had fun and Sturgis
@NorCal-refrigeration2 жыл бұрын
Ya the Larry the Cable Guy cos play. 😂😂😂✨
@mrbugenhagen33642 жыл бұрын
I am guessing Buena Vista landfill will get a new yellow box shaped addition soon.
@michaelmonfeli736 Жыл бұрын
Vinyl hose on the drain fitting and run it down the side of the box. I usually do that into a garbage can so that I can dump it out.
@WswRefrigeration2 жыл бұрын
Turbo air actually makes some decent walk in equipment. Their outdoor condensing units are not half bad . I came across some last year and was pleasantly surprised Their reach in stuff I’m still not a fan of
@OcRefrig2 жыл бұрын
Outdoor units look like re-badged Heatcraft. Almost identical.
@jorgeaguila67742 жыл бұрын
Great video brother thanks!!👏👍
@karlandersen7932 жыл бұрын
I actually had a similar leak on a reach in unit that's I used orange flux coated 46%(I think) silver brazing rod to get it sealed. Sanded and painted over the bare metal.
@jasonjohnsonHVAC2 жыл бұрын
Orange is 56% silver....blue rod is 45%
@pedrojardim11632 жыл бұрын
Dave dave is no brazing on that one New compressor no question ask🤣🤣
@gigi6442 жыл бұрын
they all have the same controller problems, not enough defrost on those and sometimes fan running only with compressor
@zacnadeau3382 жыл бұрын
Dave you need to get the porta blaster!!!!!!! It’s a pain in the ass to set up but I have used very hot water and have had so much success!
@andrewedis99072 жыл бұрын
Good find
@davejohnsonnola15362 жыл бұрын
Back blowing the condenser coil....¡Flashing back to Jim Petinato crop dusting the mini-mart! You ever blow them out with a large wet towel draped in front of them instead of dealing with the soup?
@NorCal-refrigeration2 жыл бұрын
Yes
@nickyengle96682 жыл бұрын
Nice Video, Thks, for sharing, my thouts,f*** that condensate loop, new compressor,done.
@Oz_is_on_fire2 жыл бұрын
Heck yah Dave, good one.
@thesilentonevictor2 жыл бұрын
Great job Dave super tech
@robertgaitskell7212 Жыл бұрын
Hey Dave great video as usual, just a tip you need a small steam cleaner makes defrosting the evaporator much quicker and less water also great for cleaning the condenser, I’ve used one for 3 years now makes life much easier.
@melikcappucci7605 Жыл бұрын
Just looked up so,e and added to my Amazon list. Great tip and can’t wait to test it out to see if it is more convenient! 👏🏽
@itsprimetime98652 жыл бұрын
yes those are very very common leaks for danfoss ... you can always use electrical tape LOL go full hack mode! those capsule units are so crap! if i had it my way i would of talked the client into scrapping that crap and install a normal coil get some sheet metal and styrofoam and close off the openings inside and ontop and condensing unit either indoor or if money allowed outdoors
@phil955i2 жыл бұрын
I wonder how much more expensive it would be to manufacture if those compressors had a suction stub made from stainless? It's not just Danfoss, I've seen it on countless others. It doesn't help if the suction line is lagged right up to the compressor body, as the surface of that stub never gets a chance to dry out.
@JohnnyJr3962 жыл бұрын
I like that leak detector! What’s the funky intro beat?
@Eddy632 жыл бұрын
Good little vid ... Thx ...
@IFIXCASTLES2 жыл бұрын
Hey Dave a Gallo gun could blow that drain out without hauling the N out. Good job ,want to see repairs. Ice machines can get real disgusting. I always cleaned mine really well. I used that ice in my drinks too !
@davejohnsonnola15362 жыл бұрын
Was thinking the same thing, have a couple of them, they aren't great for much but that little condensate drain was a perfect candidate instead of lugging the nitro tank.
@jamierushing88112 жыл бұрын
Hi bro from west Alabama peace and love
@steveH3842 жыл бұрын
man that condenser reminded me of these two weird glycol chillers a local brewery had... right by where they fill their grain. Just blowing them out with co2 it was like desert storm, I couldnt see 4 feet from me. In hindsight i prob should have hosed em out considering sloped floor with a drain woops!
@winkhvac62 Жыл бұрын
Dave I need a sunjoe
@frankjackson19182 жыл бұрын
Moe told me you can JB weld that suction line and Hack agreed.
@NorCal-refrigeration2 жыл бұрын
PVC glue I used stay tuned
@davidharmon874527 күн бұрын
Dave is the only SuperTech in California. Jn.316
@davidharmon874527 күн бұрын
Another block of ice.😢
@crg0612 жыл бұрын
Good call on the sun joe , it’s trash
@JuanNOnly1232 жыл бұрын
How do you like that Uni-T clamp meter? Has it held up? Pretty accurate?
@stevee77742 жыл бұрын
So tell us, how do REALLY feel about the Sunjoe?
@NorCal-refrigeration2 жыл бұрын
😂😂😂😂😂
@oldognotricks Жыл бұрын
Just thinking has anyone tried repairing a leak like that with orange rod?
@NoorRefrigerationsystem2 жыл бұрын
Sir, it would be great if all of us who are dealing with air conditioning online all over the world can come together in some way.
@zack99120002 жыл бұрын
epoxy the fitting on
@winkhvac62 Жыл бұрын
No more ice for me
@arthouston73612 жыл бұрын
I do not like those evap boxes mounted on top of the walk-ins.
@myykmikelakers1357Ай бұрын
That was a fixable leak
@shine-cg9uf2 жыл бұрын
👍💪❄️🇺🇸 Great vid
@jerryfrigeration2 жыл бұрын
Wow I just ordered the SunJoe because you used it This sucks
@NorCal-refrigeration2 жыл бұрын
Just take care of it. I’m a bull in a China shop
@bluecollardownunder36162 жыл бұрын
oh no SunJoe bad review!!!😁
@winkhvac62 Жыл бұрын
Oops never the end
@RjsEpicAdventures2 жыл бұрын
Be an epic next video if they let you do it $$&&
@ia95622 жыл бұрын
🔥🔥🔥🔥🔥
@kingofthecrease302 жыл бұрын
i hate capsule packs....nothing but problems.... constant frozen coils and water leaks...especially that norlake garbage....turbo air is just as bad....typical danfoss compressors....the body rots out by the suction inlet...common problem on manitowoc undercounter machines
@juanugomusic95882 жыл бұрын
😎
@GoatzombieBubba2 жыл бұрын
Mister head would be better if they make one...
@albertopd7775 ай бұрын
🏅✌💪💪💪
@ronnies59002 жыл бұрын
A Hammer and a chisel would of gotten that ice off a-lot quicker Jk Just did a evap coil change out because of a customer like that
@Justintime6312 жыл бұрын
Stop screwing around with those junk sprayers and get the coil jet cj125 Yes it’s pricey but you pay for what you get. Mines 7 years old. Only thing I’ve ever done to it is a new battery, and that’s cheap enough on Amazon.
@davejohnsonnola15362 жыл бұрын
Was gifted one of those to my side job Bob home address, but haven't broken it or out had opportunity to use it.
@NorCal-refrigeration2 жыл бұрын
Rinse kit sent me the pro it’s killer
@myykmikelakers1357Ай бұрын
That was a fi
@HardKnocks1012 жыл бұрын
Duct tape!!!
@mikestevenson18192 жыл бұрын
Plugo
@jamnben2782 жыл бұрын
click, click, click
@steveblake87662 жыл бұрын
438 thumbs up
@shine-cg9uf2 жыл бұрын
👍🥲❄️🇺🇸 ? 4 u. It’s a critical charge unit with no sight glass no receiver why do they instal txv ?
@davejohnsonnola15362 жыл бұрын
Because its more efficient than a cap tube.
@shine-cg9uf2 жыл бұрын
@@davejohnsonnola1536 thanks appreciate your feedback 🙏
@davejohnsonnola15362 жыл бұрын
Txv will react to a changing load much quicker than a cap tube. Especially in a small box that will experience a lot of door openings and overloading of product during business hours
@shine-cg9uf2 жыл бұрын
@@davejohnsonnola1536 great information. I was thinking u needed a liquid receiver with a txv in refrigeration. Thanks again 🇺🇸💪❄👍
@davejohnsonnola15362 жыл бұрын
@@shine-cg9uf by no means expert, but I believe that all units without a receiver would be considered "critically charged" . Like Dave said in the video, need to weigh out to get a better diagnostic, and weigh back in exact amount of refrigerant to start fresh. At a low load condition, refrigerant will back up and fill more of the condenser with liquid. If repairs are made, say the condensate tubing loop that sits in drained water is replaced with a homemade one with fewer turns and less total length, the total charge may be slightly reduced. However, if while making that repair, the filter drier is replaced with a larger one, charge may need to be an ounce or three more, but still very near the stated factory amount.