Furnace ECM Motor Repair

  Рет қаралды 198,656

John Salt

John Salt

Күн бұрын

Пікірлер: 543
@Rchelicopterfun
@Rchelicopterfun 5 жыл бұрын
May 2023 Update! This used 3.0 ECM I put in 6 years ago is still working. It has outlived both previous brand new 2.5 ECMs. Is the 3.0 a better ECM than the 2.5? Is it lasting longer because I put one of those Zebra Instruments ECM surge protectors in ( amzn.to/3LCtZwl )? Or perhaps I've just been lucky with this one? Regardless, thanks to a commenter here, I was made aware of another product to convert one of these communicating ECM's (like the 2.5 or 3.0 used in my evolution system that talks to the main control board), to a standard robust 3 speed PSC motor through an independent logic board so no faults will be triggered. As far as the main board is concerned, there is still an ECM motor in the unit "talking" to it. I've been searching for such a product since my first 2.5 failed, and finally we have something. It's called a QwikSwap board made by Mainstream Engineering. The one for my 2.5/3.0 communicating system is their V3 QT6104 model: www.qwik.com/product/qwikswap-x1-x3-v3/ Here's an Amazon product link: amzn.to/2YdMLlj These things are around $330 USD, plus the cost of a new 3 speed PSC motor (about $125), bringing the final cost to around $450 USD, but that's less than a new ECM (a lot less up here in Canada), and you'll never have to worry about another expensive ECM motor failure. Just fire in an easy to source $125 PSC motor next time (if there is a next time). Another fairly recent budget option is to get one of the aftermarket Evergreen ECM & Motor units. These are less costly (about half the price) of the original Gentek motor/ECM combos and are said to be more robust. It's still an ECM motor however. If anyone has experience with the Evergreen ECM motors (good or bad), feel free to leave a comment below.
@charlescunningham3050
@charlescunningham3050 5 жыл бұрын
This is a good idea! Unfortunately, for me in the Colorado area, doesn't look like there are any distributors. Do you know how I could get my hands on one of these
@joeydelmarsjr.646
@joeydelmarsjr.646 5 жыл бұрын
i saw it too on another video, good for DIY
@Rchelicopterfun
@Rchelicopterfun 5 жыл бұрын
On Line... I've seen them on eBay and at online hvac supply stores.
@scotthsmith8635
@scotthsmith8635 5 жыл бұрын
Jake Fournier The first thing you should do before going PSC is check the external static pressure on your duct system by taking a reading across the HVAC unit. If there is anything beyond 0.5 inches of static pressure then PSC may not be a solution There’s a reason why we use ECM motors and to overcome high external static pressure. You may also add return air grills and/or supply registers to reduce static pressure. Also undersized ductwork can be replaced
@Rchelicopterfun
@Rchelicopterfun 5 жыл бұрын
@Scott H Smith Sorry, but I have to chime in and no disrespect is meant since we are all learning here. I have checked ST on my system when the first & second ECM 2.5 failed and it was low both times & within spec. The best I can determine after further testing of my second failed 2.5 unit after digging it out of the potting compound (a 2 hour job) is one of the three back EMF circuits that tells the ECM where the motor is positioned for proper timing has failed. All 6 MOSFET's themselves were fine and working, but one of the three phases was not triggering. That's what causes that rumbling and jerky movement - only two of the 3 phases are powering. My best guess is not enough built in back EMF protection or simply not having enough component cooling. All anecdotal evidence to my one tested unit of course. Regardless, when it comes to PSC's retrofits for those that decide to go that route, no worries about restrictions with them. The higher the restriction (be it return or output), the less current a PSC will draw because it's not moving as much air and thus not working as hard. All standard motor driven impeller type pumps for fluid or air follow this principle of increased restriction = less current load. Now, such restrictions very well could cause higher loads and premature failure of ECM motors because they will presumably try to compensate for the reduction in air flow by spooling to higher RPM's to maintain their set flow rates, at least that's the reason I've been told by several HVAC engineers. I really would like to confirm this one way or the other on our residential Gentek ECM's by monitoring how much load is going across the MOSFETs while in operation as flow restriction is increased and decreased; but since they are sealed in silicone potting compound, there is no practical way for a homer owner to get to them for testing. Regardless if ECM motors do draw more current when flow is restricted and are being overworked and that is why they are pre-maturely failing, I still don't buy into this reasoning. Why? The beauty with all electronic 3 phase commutated motors is their ability to be "smart" and automatically speed up or slow down based on whatever algorithm is controlling them. If Gentek were honest, smart, and wanted to make a product that would last, they would have algorithmic safe guards programmed into the ECM to save both the motor and ECM control unit when high loads or ECM internal component over-temps are experienced, by throttling down the output, and on communicating system, flag a code if the condition persists. "System Malfunction - High Static Pressure Detected or High ECM Load/Temperature Detected." Most communicating systems as you point out already monitor static pressure as well so there is no reason the ECM's algorithm shouldn't be able to use that as well to throttle output to a safe level for the ECM. We are talking firmware, nothing special. Our little RC ESC's that are dirt cheap have a multitude of built in algorithmic protections such as over current, over temp, over speed, over/under voltage, high ripple, and if they were used in a model furnace that monitored static pressure, they would no doubt have over pressure protection as well. Some even have data logging/telemetry to help diagnose powering/load issues. So if a $60 RC ESC can have all that "smart" protection built into its control algorithm, why can't a $600+ consumer grade HVAC electronic controller have it? The only reason that I can come up with is Gentek & the furnace manufacturers are crooks, and their current line of brushless 3 phase electronic commutated controllers represent a false economy. Saving a few bucks a year on power doesn't offset a thousand dollar expense every five, or even ten years. Working families on modest or fixed incomes simply can't keep getting screwed over by these pirates. My god, there are people who have commented on here that have been quoted half the cost of a new furnace or higher for an ECM & Motor replacement. This has to end! No more excuses - time to hold these buggers accountable for their crap product.
@ericcowan3619
@ericcowan3619 2 жыл бұрын
You say that you are not an HVAC guy, yet you put together one of the greatest HVAC videos that I have ever seen. Great job!!!
@ParabellumX
@ParabellumX Жыл бұрын
John, thank you so much for putting this video out there for us. I am halfway finished attending college for HVACR, and I'm researching countless resources, trying to learn as much as possible about this field. I can't wait to go back to class after Spring Break is over, remove a blower motor from one of our test/practice units, and show my instructor what I learned from watching your video! Again, thank you SO much!
@ParabellumX
@ParabellumX Жыл бұрын
UPDATE: Wow! I really impressed my instructor! When I showed him, his eyes got wide! He smiled and said, "I can tell you're going to go far in this field. But don't get hung up in the details of things; just keep it simple. Remember; you're trying to make the most money in the shortest amount of time. If there's a problem with a motor, and you know for sure that the motor is bad, slap a new one in there for 'em, get your money, and go on to the next service call. In the end, their unit is back up and running again, you get rewarded handsomely for your knowledge and time well spent, and it's a win-win situation for everyone." 😏
@greatlife765
@greatlife765 5 ай бұрын
Hi sir is this motor can be used as a condenser fan motor
@JohnRodriguez-ll4vc
@JohnRodriguez-ll4vc 4 жыл бұрын
you're better at trouble shooting, diagnosing, and finding parts than most of my service techs.
@stephenliso2225
@stephenliso2225 Жыл бұрын
Thank you John, it's wonderful to see DIY solutions. I have 3 x Bryant AC/Furnace systems all using HD44SE120 motors with 2.5 ECMs - installed, June 2008. One EMC just died yesterday Aug 2023 (15 years later). I will be following your good advice.
@bmich281
@bmich281 2 жыл бұрын
Thanks! @John Salt That Quick Swap V3 saved me $1300. I just did it after finding your video on 6/13/22. I can't thank you enough! I got my parts from supplyhouse which sold me everything. The V3, a motor and a capacitor. I was going to buy amazon but they had junk psc motors and they were costly. I found a variable speed 1/2-1/6HP for $90.00, the cap was $3 and the V3 was $350-380ish. I cant remember. But shipping was overnight and free. Thanks again! I'm the hero to my wife! The past two days have been the hottest days in 10 years here. I was quoted at $1850.00 for a new ECM motor.
@Rchelicopterfun
@Rchelicopterfun 2 жыл бұрын
That is great news Ben you got yours working with the QwikSwap, saved a good deal of coin, and you were able to get all the components from Supplyhouse (nice one stop shopping). Wish they would ship up to Canada - great selection of parts. Always a good thing to be a "hero" to the most powerful person in our lives - the wife 🙂Thanks so much for the Super Thanks. Will put it toward the V3 conversion when I have to get one when this used ECM puffs out its last electron. I have another used one here, but I know I would feel better with the QwikSwap. Stay cool mate...
@ericmoon8043
@ericmoon8043 2 жыл бұрын
I have a similar carrier. My furnace guy tracked it down to the ECM control unit, and correctly predicted the capacitor would have a burn mark. I ordered one from mouser and soldered it in. The company quoted $1800 to purchase and install a new board. The capacitor was $8. Tomorrow I'll put it together and see it if works!
@nrjank
@nrjank 8 ай бұрын
Did it work?
@mousearebec
@mousearebec 3 жыл бұрын
One of the better explanations than I have seen on line. That "Canuck" accent...... love it.
@GeorgeLecakes
@GeorgeLecakes 4 жыл бұрын
Thank you for the video. Technician came in and flat out told me everything in my system was crap and wanted me to pay thousands through their preferred loan company to replace it all. Sent him packing and went up myself and pulled out the blower. Found the 2.3 version installed and your video helped answer a lot of questions I had on replacing it and getting the right information.
@Rchelicopterfun
@Rchelicopterfun 4 жыл бұрын
Glad it helped
@traumajock
@traumajock 4 жыл бұрын
same here. We contracted with a local company to do maintenance on the HVAC in my rental property. They said I needed a whole new system. I took apart and rebuilt the previous system in that small crawlspace by myself (20 years ago). I pulled the blower assembly and am changing out the ECM. Found one on ebay for 130 bucks. I hired them so I wouldn't have to crawl my old ass in that hot attic again. Lesson learned. I used to repair cameras with tiny little parts, so big sheet metal boxes with a fan and a small amount of electronics don't scare me.
@hughgordon335
@hughgordon335 4 жыл бұрын
Great video sir; its still helping people like me. I have a Rheem 3.5 ton with the Gentaq X13 ECM installed in air handler. I observed the motor would jog back and forth for up to five minutes before running steady. There was my answer in the 14 of the ECM Service Guide. Saved me from plunking down up to $300 for a new motor. Thanks you so much.
@Rchelicopterfun
@Rchelicopterfun 4 жыл бұрын
Good to hear
@eegg6954
@eegg6954 Жыл бұрын
Great video. How many of us are left who work on our own stuff and learned about electronics back in the day before microprocessors?
@KennethDiStefano-gt1zs
@KennethDiStefano-gt1zs 4 ай бұрын
John I just found this video 4 days ago after my blower was having a similar problem. You literally saved me around $2000 (difference between the part and the repair quote). THANK YOU!!!
@mtbbiker6401
@mtbbiker6401 4 ай бұрын
I'm having the same issue. My motor tries to spin but can't. What parts did you end up replacing....the entire motor assembly or just the control module. Mine is a gentec ECM 2.3.
@KennethDiStefano-gt1zs
@KennethDiStefano-gt1zs 4 ай бұрын
@@mtbbiker6401 It's exactly the ECM part shown replaced in this video. But my spec was different. I went on ebay and found someone selling the -exact- same ECM as mine. At the very least the ECM x.x, HP, Volts, GCxx must match. But also the Exxxxxxx in the left hand corner of the sticker matched with mine as well. Not sure if that made any difference.
@mtbbiker6401
@mtbbiker6401 4 ай бұрын
@@KennethDiStefano-gt1zs Thanks. I did the ohm test on my motor leads and I'm getting 1.2, 4.8, 4.4 so I believe there's a problem with my motor windings. At minimum I'll need a replacement motor and possibly an ECM also.
@jeffmcdonald918
@jeffmcdonald918 4 жыл бұрын
I did the same repair approx 3 years ago when my ECM motor controller failed. The 3.0 conversion I installed is still working and I hope it provides me with dependable service for a few more years to come. Thanks for a great video and your commentary is wonderful!
@Rchelicopterfun
@Rchelicopterfun 4 жыл бұрын
Nice work.
@randyrivera1089
@randyrivera1089 2 жыл бұрын
do i need to program a new or used ecm?thanks
@sunset986S
@sunset986S 7 жыл бұрын
You make all us Canucks proud by doing this...keep your stick on the ice my friend!
@bettinaneumeyer6760
@bettinaneumeyer6760 3 жыл бұрын
Hi John ... I want to thank you for this video. My problem initially was furnace would need power reset and then finally it stopped altogether. It also was giving blower motor problem on LED light. Motor also pulsed like yours. I bought a used ecm on ebay. Luckily the guy was only 1 hour away so i picked it up. I plan on trying to take the conformal coating off of old ecm and try to trouble shoot original problem. Will update if i can fix it. Thank you for this great video. You saved lots of money for a lot of people.
@nrjank
@nrjank 8 ай бұрын
Old comment, but did you have any luck playing around with the old one?
@tomfurr5760
@tomfurr5760 3 жыл бұрын
Great Video. I understand that Trane has a universal choke kit for problematic ECM motors. Rather than repeatedly changing the ECM module. It protects the module from power surges
@chrisguillen1495
@chrisguillen1495 9 ай бұрын
That’s the number one killer of these motors.
@scotthsmith8635
@scotthsmith8635 5 жыл бұрын
John, thanks for your video and assistance. I have an Amana unit which is similar to Goodman and other brands out there. So it’s not just Carrier and their other product line. It’s almost every HVAC manufacturer that utilizes ECM. Mine ran for about 9 years and then a capacitor went out in the ECM. Mainly due to your DIY video and a few other informative pieces I’m just going to replace the capacitor. While I’m waiting for the part to come in, I installed a 120V 3/4 HP PSC motor and capacitor. Plugged into the wall for constant run so that we could stay comfortable. Good luck to all.
@MalaAndPaul
@MalaAndPaul 2 ай бұрын
I know this is really old but Im also in a similar situation where I have a blown/bulging capacitor in my ecm module. I ordered 2 capacitors to replace both even tho only 1 is bulging. Just wondering if your capacitor replacement worked and is the ecm motor running? Thank you kindly.
@mahakoushik
@mahakoushik 3 жыл бұрын
Love the detailed video and the self-deprecating sense of humor. Just thought I would let you know that when you rectify 230VAC, you get ~320V DC because 230V is the RMS and the peak will be 325V. About 4-5V is dropped in the rectifier diodes.
@Rchelicopterfun
@Rchelicopterfun 3 жыл бұрын
Yep, thanks for pointing that out.
@orlandojohnson5742
@orlandojohnson5742 Жыл бұрын
Easy replacement on a heat pump air handler! I installed a relay off the control side to the fan! Had to make sure it worked for emergency heat too! I hate ECM motors too!😅
@Observe-n-Learn
@Observe-n-Learn 2 жыл бұрын
Currently going through this hell. Ditching ECM's since they are designed to fail and the manufacturer made them unrepairable by potting the components that fail. Not unlike the garbage disposals designed to rust out after 8 years. Probably going three phase motor with variable VFD or split phase. Just need some air moving in the air handler and duct system, since I put three mini-splits in my house. Much better than a $13K single heat pump, which always fails in August and we're screwed with a $500 emergency call. Thanks for the vid.
@darrell2292
@darrell2292 7 жыл бұрын
Thank you for the excellent job posting and explaining the ECM module replacement. I just finished replacing my ECM Module on a American Standard furnace AUD080R9V3K4 with the help of your video. The new OEM part cost me 700 Canadian ordered online in Canada. I got in a local HVAC company and was quoted 2500 for part and replacement (wanted a professional diagnostic done before I ordered the part and confirmation of the part number). If anyone else is looking for the ECM module part number it is Trane ECM BLOWER MOTOR MODULE MOD02186 (This one is programmed from factory). The replacement of the ECM module was a little more intense with a removal of the blower motor and ECM module before I could get at the ECM Module. took 1.5 hours to complete and everything is working. The HVAC company would of made 2K off of me for 1.5 hours of work. Lawyers do not make that an hour. Shame on you HVAC company. I also have two zones and two furnaces so I was not in a hurry situation. Thanks again John and I am also a RC guy and am very, very grateful for your post.
@mikekeers6401
@mikekeers6401 4 жыл бұрын
I watched your video and it matched my case exactly. So I ordered the Module from EBay and was back up in 5 days. Thanks for making such a clear and easy to follow video.
@Rchelicopterfun
@Rchelicopterfun 4 жыл бұрын
Glad it helped.
@raorsa1
@raorsa1 Жыл бұрын
Thank you very very much!!! Now understand how to troubleshoot this items, thanks for the RC comparative analysis!
@wonyoon1931
@wonyoon1931 4 жыл бұрын
John, Thank you so much for your video. Most of AC guys in youtube doesn't explain in detail like you. It was very informative. I have an air handler with an ECM motor. When it breaks, I know what to do. Mine is Goodman. But I am sure it is from the same manufacturer.
@Rchelicopterfun
@Rchelicopterfun 4 жыл бұрын
Glad it helped
@oldskule2091
@oldskule2091 Жыл бұрын
Thank you very much! Loved the common sense comments. Pos is right. I didn’t even know this thing was on fan. After trying everything else, in Florida heat I called good local company. He obviously knew what it was when he walked in door. I already had covers off. He changed out & it works. I haven’t gotten bill yet, but wifey happy & quality of wife means A LOT 😀. I’ll know if there’s a next time. Carrier now made in Mexico! Lots of folks lost their jobs in Indiana because of this change.
@mrpawpaw7023
@mrpawpaw7023 3 жыл бұрын
Thanks for your video. Like you, I did it myself for an older carrier unit and saved $973.00 over the cost of a HVAC tech. Frankly, I think this is ridiculous for a couple of hours work max. Also, I will be avoiding the newer Carrier units per your ownership experience. I replaced the entire unit (motor and ECM) from the Tampa outfit, who sells motors and ECMs sealed as a warranted unit together.
@mattneibaur215
@mattneibaur215 5 ай бұрын
Thanks for this video. I had the same issue and error code. I found the part on ebay for $80 vs $3000 for AC repair quote. It is working fine, and I bought a backup ECM too. From discussion on reddit, I learned that I may have inadequate return airflow causing premature failure of ECM. I plan on adding a second return duct.
@dadomacasaet5064
@dadomacasaet5064 3 жыл бұрын
John this is the most accurate and clear procedure for my exact situation... Thank you very much for sharing this!
@Rchelicopterfun
@Rchelicopterfun 3 жыл бұрын
Glad it was helpful.
@genehathcoat6311
@genehathcoat6311 11 ай бұрын
Thanks for information 45 years of service first one I've ever seen
@robg5630
@robg5630 6 ай бұрын
Great video! I have a Lennox that has the 2.5 ECM. The original from 2005 lasted 13 years. The first (2018) replacement lasted 6 years, and now I'm on my 3rd replacement (2024) , we'll see how long this one will last. Like you, I'm going to get a spare.
@pcp212
@pcp212 4 жыл бұрын
Just experienced the same problem with mine at home. Luckily its still under warranty. Didn't read through all the comments, only the first 100 +/-. Someone may have mentioned this already but they do sell a ECM motor surge protector. As the packaging states "The most common cause of ECM motor failure is damage to the electronics module as a result of poorly conditioned voltage." I'm looking at the VZPRO from zebra HVAC. It's a very simple harness that plugs in line with existing motor and wire harness. My local hvac supplier has them for just over 30 bucks. Considering the alternative, it's a very small price to pay if it works.
@Rchelicopterfun
@Rchelicopterfun 4 жыл бұрын
Zebra's VZPRO's ECM surge protector is mentioned somewhere in the comments, and I installed one on my unit shortly after I made this video from that recommendation. By all accounts, there is already adequate surge suppression & filtering within the ECM going by the number of MOV's and inrush current limiter on the input side of the circuit board; but as you say, for $30 beans, it's certainly worth trying and won't do any harm. There is no doubt these ECM's hate dirty voltage. My used 3.0 is till going strong and it's been over 3 years now, so who knows... Maybe the external surge protector is actually working 🙂
@Bondovian
@Bondovian 3 жыл бұрын
Great video. I have the same exact furnace and my motor just cogs back and forth and wont spin up! Replaced the motor and ECM in September with a remanufactured one from United HVAC motors in FL and now that one has gone out! Ugh! Frustrating! It's cold here in Indiana now and need it replace ASAP! thanks again!
@willie9397
@willie9397 6 жыл бұрын
I have a problem with my furnace not working and upon further investigation because of your video I found the problem, thanks for sharing the video
@azzabar
@azzabar 3 жыл бұрын
Thanks, that was great. I am having this issue right now. Odd that my AC failed last night and this shows up in my feed this morning. 🤔
@Daluke61
@Daluke61 4 жыл бұрын
Exercising caution by not 'lighting' ones self up; words to live by for sure. Good overall information regarding ECM's. Should help this DIY'er... thanks!
@gerryconnolly5426
@gerryconnolly5426 2 ай бұрын
Thanks, you've given me the courage to find and change the ECM on my 19 year old Carrier infinity 3 ton heat pump. Think I'm going to have to pay a lot more though...
@iskoos
@iskoos 6 жыл бұрын
Thank you John for taking time and making this video and also following up with the questions/comments. I am also coming from an RC scene and am fairly familiar with Brushless motors/ESC system. It was fun to watch you explain all that. In my Carrier heat pump unit, there is one of those f...ing stupid ECM motors that is sold under the environmentally friendly/high efficiency scam. The one in my unit is called ECM X13. The original motor lasted for 3.5 years(Didn't know it was under 5-year part warranty at the time). Bought a replacement which lasted only one year. After the 2nd motored burned out, I was still under 5-year warranty and was able to get a replacement motor for free. That one lasted 5 years then said bye... Bought another one which lasted less than a year. So 4 blower motors in about 10 years. That is enough for me to call this technology a piece of $hit. I am highly considering doing a PSC induction motor conversion. It may not be as efficient in a short term but heck it will be more efficient in the long run because it will last for decades...
@Rchelicopterfun
@Rchelicopterfun 6 жыл бұрын
Yep, a total POS is right! I maintain these stupid things are no good for home HVAC applications after hearing more and more comments just like yours. As I mentioned to another commenter, they represent a total false economy. I'm interested in these PSC conversions too. I've heard a little bit about them, but nothing more than that. Do you have any good links to something explaining the options/procedures (if any yet)? I can only imagine if someone came out with PSC conversion modules for all the various ECM's out there, so we could all convert to good & proven reliable induction motors, they would make a small fortune!
@iskoos
@iskoos 6 жыл бұрын
John, there are a few KZbin videos showing how to do the ECM to PCS conversion but I found none of them shows it step by step for people that aren't in the field. Though it shouldn't be a big deal. PSC equivalent motor is easy to find and pretty much a direct replacement. Costs about 100 bucks brand new. A few wiring will need to be changed/rerouted and a capacitor will need to be added. (Maybe in some cases a relay or contactor). That's pretty much it. Probably one hour job for someone who knows what to do. Not sure if a module that converts the ECM to PSC would be practical or even possible since ECM motors are running on DC power. Someone though (if they ever) may come up with an aftermarket control module to fit on the current ECM motors and if their price is competitive and their units last, they will definitely make money off this. I have several ECM motors in my hand. All would need a working module and they would be good to go...
@Rchelicopterfun
@Rchelicopterfun 6 жыл бұрын
Thanks for the info on the PSC conversion. I'm wondering however how that method wouldn't throw a code since the mother board is not seeing any communication from the ECM telling it the motor is in fact working? With this Carrier/Bryant Evolution system I have, any funrance/fancoil motor fault code shuts the entire system down. I'm sure other systems are different and don't do that however by quickly reading a few PSC conversion posts. My thought on the "PSC conversion module" would be a device that plugs into the communication 4 connector plug that communicates with the main board in its native protocol. The power plug would also plug into it to supply the motor power. That main power plug is by the way supplying VAC; it's the rectifying circuit in the ECM that changes it to DC. At any rate, the conversion module would communicate with the mother board and trigger the relay/s as instructed by the mother board to send 120vac to the PSC motor. Turning it on, off, and if it's a multi speed PSC motor, at what RPM stage to run at (low, medium, high for example with three different relays). All the time communicating back to the main board in the furnace or fancoil all is working well so the mother board won't know any different and throw codes. Doubt it would be easy, but if affordable & more robust aftermarket communicating ECM's are ever available, conversion ones to run a different type motor should be possible as well? I would love to see a lower cost aftermarket option to these things. Even if they are just as crappy, they would drive the cost of the OEM Genteq ones down. You hit on the biggest issue with these ECM motors (next to their disposable failure rate), zero competition! Genteq can charge whatever they want to, and they are doing just that as we all know.
@iskoos
@iskoos 6 жыл бұрын
Hmmm, You know? You do have a point there!.. I never thought about the smart thermostats that get feedback from the ECM motor. My thermostat is a simply relay device that sends a signal to the air handler's board so it can energize the 24 volt wire to start the ECM motor. It is a dumb device. It doesn't know what's going on at the motor end. All I have to do is to add a contactor that uses the 24volt to energize the 230volt-end which will be connected to the PSC motor. And all should be good to go. And this setup will have a one-speed setting obviously. The speed of the PSC motor could be manually adjusted I believe. But since you have a kind of smart thermostat, I do understand it won't be this easy. Yes, your thermostat may refuse to control the motor thinking that something is wrong since it won't get any feedback. You may go back to a simple thermostat:) Genteq has a few competitors as I see now. There is the Evergreen motors that replace ECM X13 (not the kind you have though). Then I found a X13 Rescue motor but really didn't hear good things about it. Then lately I found Azure Digi motors by Mars. This one might be promising. I will check them a bit more before going with PSC route. I also found an ECM motor rebuilt center in south Florida (They are in Tampa) and it seems they rebuild all types of ECM motors made by Genteq. They sell it either a complete motor or just the module. They have your motor in stock. They only give 60-day warranty though. It will work but not sure if it is smart to spend money on. Because I know they will quit in a few months. They are the same design motors made by Genteq and I have zero trust on this company (Genteq). There is a design flaw on these motor modules. Manufacturer doesn't want to recognize it. But all the HVAC guys know this issue. Something will eventually happen and this problem will come to an end. I don't know when. I would love to use a variable speed/torque motor than a PSC motor but only if a reliable design comes into market...
@tomtom1541
@tomtom1541 3 жыл бұрын
@@iskoos do you realise that if you have an issue like high static that will cause motors to fail over and over again?
@jimh1263
@jimh1263 2 жыл бұрын
Thank you for the excellent video and explanation of how to diagnose ECM motors! You may have saved me from a large repair bill if it works!
@Rchelicopterfun
@Rchelicopterfun 2 жыл бұрын
Glad it may have helped - thanks for the visit.
@DFWKen
@DFWKen 3 жыл бұрын
I believe that any money saved from lower fuel consumption are far outweighed by the maintenance of the furnace. I was a Bryant dealer. Loved the furnace and loved selling them . . . . .UNTIL . . . they started breaking down and costing $1K or more to repair. Always sold with a 10 year parts and labor. But $1,000+ repair expense after warranty expiration is still too much and exceeds any energy savings. Just my experienced opinion. Maybe they're better now.
@mattboorom9909
@mattboorom9909 3 жыл бұрын
Couldn’t agree more!
@NoSuffix
@NoSuffix 2 жыл бұрын
You are absolutely right!
@OnePointLander
@OnePointLander 2 жыл бұрын
10 year labor ? Wow thats impressive.
@pipsqueak631
@pipsqueak631 2 жыл бұрын
Born to break.
@billl3936
@billl3936 7 жыл бұрын
Good job! I'm glad it was May and not January that you were waiting two weeks for this part. Otherwise I don't think your Hudson Bay blanket would've kept you warm.
@BarryWinner2075
@BarryWinner2075 3 жыл бұрын
Great video, I had the same problem with a York Diamond 80 only it looks like the themistor is burned with no current going through, I am just ordering a new one now, it looks like it is fairly easy to solder in.
@Rchelicopterfun
@Rchelicopterfun 3 жыл бұрын
Hope it works 👍
@BarryWinner2075
@BarryWinner2075 3 жыл бұрын
Works great after soldering in the new thermister, and it only cost $6 for two of them, Fixed it just in time for the winter heating season , They wanted $1100 for a new ECM motor
@scotthsmith8635
@scotthsmith8635 5 жыл бұрын
The first thing you should do before going PSC is check the external static pressure on your duct system by taking a reading across the HVAC unit. If there is anything beyond 0.5 inches / 125 Pa of static pressure then PSC may not be a solution There’s a reason why we use ECM motors and manytimes to overcome high external static pressure. You may also add return air grills and/or supply registers to reduce static pressure. Also undersized ductwork can be replaced
@robertjackson7590
@robertjackson7590 2 жыл бұрын
Excellent info Scott, Thank You. I had an Inrush Thermistor fail after 20 years and if I had it failing at 5y I'd be checking supply voltage and your advice. John might have an underlying problem.
@nyrangers3150
@nyrangers3150 6 күн бұрын
Thanks John. Great video. I am having the same problem with the motor stepping like yours. Can't wait to open it up.. 🙂
@Rchelicopterfun
@Rchelicopterfun 6 күн бұрын
Good luck with the repair! Hopefully, you can get it running again.
@josemaldonado-bw1pb
@josemaldonado-bw1pb 5 жыл бұрын
excellent video more information than a furnace manufacture thanks keep up the good work
@jamesdaws3457
@jamesdaws3457 3 жыл бұрын
Thanks for this video - not only informative, but entertaining too.
@Rchelicopterfun
@Rchelicopterfun 3 жыл бұрын
Glad you enjoyed it
@MrWaynesea
@MrWaynesea 2 жыл бұрын
Thanks for sharing your knowledge of electronics as well as your experience with the repair.
@abaidrehman4883
@abaidrehman4883 2 жыл бұрын
You have a fantastic teaching skill thank you so much 😊
@Rchelicopterfun
@Rchelicopterfun 2 жыл бұрын
Thanks & you're very welcome. 🙂
@ISAIAHXKENSHIN
@ISAIAHXKENSHIN 3 ай бұрын
Supco has a ecm kit to test as well. As a tech and having alot of calls daily I would wouldn't have time to check all this but this is good and thorough. I would check resistance, continuity and all unplug modex plug going into the blower and check voltage and if I'm getting proper voltage going into motor and still not running then I know for the most part my motor will be getting replaced.
@pipsqueak631
@pipsqueak631 2 жыл бұрын
I had a customer with a Carrier system where the EMC motor only ran on high. It took replacing the module to solve the problem. I get feedback that the 2 stage gas system uses more gas to heat but it's still a Comfort System. And the 2 stage or more stage systems are great at dehumidification in Summer.
@paulbavis9913
@paulbavis9913 2 ай бұрын
THANK YOU - THANK YOU - THANK YOU. Great video and is going to save a tonne of loonies! Carrier ECM 3.0 won't communicate static pressure to board/thermostat and doesn't ramp up to full CFM when called for. Tech says CAD 2000 parts plus labour plus GST.
@Rchelicopterfun
@Rchelicopterfun 2 ай бұрын
Glad to hear it might help - thanks for watching.
@DIRTTRIKER
@DIRTTRIKER 2 ай бұрын
Excellent video, is it possible to run this motor with the AC to DC converter but not with the electronic controller? The one I have is ECM 2.3
@Rchelicopterfun
@Rchelicopterfun 2 ай бұрын
No. The controller is what converts the DC into a 3-phase AC waveform (these are essentially 3 phase A/C motors) and is also what communicates with the main control board of the furnace/airhandler/AC/heatpump.
@DIRTTRIKER
@DIRTTRIKER Ай бұрын
@@Rchelicopterfun there is not a controller, i simply want tov use the motor with on off switch
@charlieb2794
@charlieb2794 5 ай бұрын
Awesome video. Just completed 3.0 upgrade. This video was extremely informative
@Rchelicopterfun
@Rchelicopterfun 5 ай бұрын
Glad you found it useful & thanks for watching.
@karlnovsak3435
@karlnovsak3435 4 жыл бұрын
Great video I have just an AC blower and the ecm seams to be bad but was built in 1999.
@huskyng6981
@huskyng6981 11 ай бұрын
You are better than service tech, most service tech their main job is replacement parts only and charge money, they dont care to spend time and fix problems
@CarlosMoreno-wv4md
@CarlosMoreno-wv4md 4 жыл бұрын
Hi. You just saved me a lot of money. Many thanks to you for doing this video.
@Rchelicopterfun
@Rchelicopterfun 4 жыл бұрын
Glad I could help
@monkeyjibeman
@monkeyjibeman 7 жыл бұрын
Wow...Brilliant...been looking for this exact description and trouble shooting...soo many identical videos that miss the other components......multiple capacitors within explains my intermittent no start on nearly new chinese goodman perfectly..Thank you and please continue .......just 1 rc guy to another......thx
@caru3257
@caru3257 5 жыл бұрын
You definitely know more than I. As a tech, I have a tool for diagnostic and customers who pay to get their A/C running.
@johncolon244
@johncolon244 5 жыл бұрын
Thank you! I learn something new to safe some money in my a/c unit air handle, I didn't known this fix, ecm fix. and bought the whole ecm motor about Two year ago I put it my self the a/c company want to charge me almost 1300 I save about 1,000 dollars, ecm cost about 300.00 dollars. Thanks a gain.
@inhocsigno9151
@inhocsigno9151 5 жыл бұрын
DC doesn't have Phase, that is a function of AC cyclical power. Maybe '3 wire DC motor' is more accurate. Nice and helpful video.
@Rchelicopterfun
@Rchelicopterfun 5 жыл бұрын
You are 100% correct. Many of us "RC'ers" call these things brushless DC motors, since that is what they are called and marketed as in our world. So yes, in actuality these HVAC ECM motors are a 3 phase AC motor. The voltage regulation side of ECM first converts the single phase 60 HZ AC input to your furnace/fancoil into DC and then the electronics within take over and convert it into a 3 phase AC waveform which can be altered in amplitude, wavelength, and even shape by some controllers to vary the output speed and torque of the motor. Back EMF from the motor is used to correctly time the phases with the motor rotation speed.
@apostolakisl
@apostolakisl 4 жыл бұрын
I think it all sort of depends on your definition of "phase". Instead of three wires that "pulse" voltage in sine wave at 120 degrees offset with a freq set by the utility, it is a 3 phase motor with variably controlled "pulse" frequency and duration that rises and falls more or less as a square wave. My understanding is that the windings on the motor are essentially the same as the standard 3 phase configuration, however the ECM only powers two of them at once and uses the 3rd to sense the position of the rotor via hall effect. Since it has fixed magnets instead of induction magnets, you have to have some way of keeping your stator magnetic field in the right place, hence a computer that knows where the rotor is. Well, at least this is how I understand it. I too have a Carrier Infinity and have had to replace one of my condensor fans. It kills me that the ECM board goes bad and you end up throwing away perfectly good windings. I also had the GE motor, not sure which model number, but I could clearly see where the ECM fried itself. The board was fully potted so it was pretty much impossible to fix it. But this whole thing is a bunch of crap. Fortunately I have 3 units in my house so things are still tolerable with one unit out provided you leave doors open and use some fans to move air around. But if you only had one unit and lived in the great white north, what the heck would you do if the thing went out in Feb and the parts were 5 days out.
@harley62t
@harley62t 5 жыл бұрын
VERRY informative....my blower quit 2 days ago and I let the Ruud service folks find the blower motor and module "failed" and the replacement motor and module would cost $1200 USD. I've been trying to educate myself on the module - you've given me the most info. My motor is 3/4 hp and has a ECM 2.3 module. The new motor with module was installed so now I have the old motor and module on the bench. I removed the module and found some arcing on the circuit and the motor checked out fine, equal resistance between coils and no coil to ground found. My ECM 2.3 lasted 10 years - now hearing your experience, I am concerned whether to just put a ECM 2.3 from Ebay as a spare. I wonder if I can also find a converter plug to upgrade to a ECM 3.0? Thanks for a great video!!
@jasonostler9221
@jasonostler9221 5 жыл бұрын
A lot of times if the capacitor or the thermistor are blown on the ECM module, you can de-solder them and solder on new components for cheap. Not sure if your unit had visible damage like mine did. I just had to replace two capacitors and the thermistor for $37 and few hours of work.
@MalaAndPaul
@MalaAndPaul 2 ай бұрын
@@jasonostler9221 Hello Jason, I know this is really old but Im also in a similar situation where I have a blown/bulging capacitor in my ecm module. I ordered 2 capacitors to replace both even tho only 1 is bulging. Just wondering if your capacitor replacement worked and is the ecm motor running? Thank you kindly.
@jasonostler9221
@jasonostler9221 2 ай бұрын
@@MalaAndPaul I also replaced the black disc looking device @9:15 and its been working since! Still going strong.
@anibalcarbonell5818
@anibalcarbonell5818 4 жыл бұрын
Great video John, well done and very explicit. I will over my unit tomorrow and believe is the ECM.
@ppm9072
@ppm9072 6 жыл бұрын
You ROCK!!! Especially enjoyed/and share the sarcasm and utter contempt. Nice job, too, clearly showing each vital step on camera. AAA+++
@rj44319
@rj44319 2 жыл бұрын
I just replaced one of these 650 us bucks for the full Assembly. It looked like I was starting to have bearing wear so I replaced both. But I want o have one ECM controller on hand "just in case" for the cold day and no heat issue. I think you can get them new for 180 bucks at some online stores. Hard to say tho that if the ECM fails it will not take out the motor too. I almost swapped the blower motor assembly for a split y cap AC motor. Way cheaper. But was worried about messing up the air flow.
@yoashuain1
@yoashuain1 Жыл бұрын
Cleanest furnace I've ever seen. Is it new?
@ebfsystem
@ebfsystem 5 жыл бұрын
Great video!! Ill love to learn more from you!! I have 10+ years of experience as a HVAC-R tech under my belt, you definitely impressed many of us !
@timothy5974
@timothy5974 11 ай бұрын
Nice! So my parents must have one of these motors. hVAC tech took the motor today and returned with a new motor and said it was bad, and he had to take it to the shop and program the motor. I think they got shafted and it was by another HVAC tech. He’s partying tonight!! Woohoo!! 1500$
@injector221
@injector221 7 жыл бұрын
One thing to keep in mind. The direction you attached the ecm and routed the cables through the top didn't create a service loop. You'll want to either face the connector down or create a service loop with the wiring to prevent water (condensation from the evaporator cold Temps in the summer) from flowing down the cables into the ecm connector.
@Rchelicopterfun
@Rchelicopterfun 7 жыл бұрын
Good catch there on the drip loop. Yes, important practice to follow and it even states it in the Genteq Service Guide I link to above. After catching that in the service guide, I did rotate the motor so the plug is now near the bottom (7 o-clock to be exact) with a proper wire drip loop. At that time, I also installed one of those Zebra VZPro ECM protectors. amzn.to/2Bwogph Not sure if they work or are just snake oil considering the ECM already has a MOV in it for voltage surges, but figured for $35 bucks, it was worth installing. Going on 8 months now with that used 3.0 in there and the fan has been running on low speed 24/7 and of course on higher speeds during cooling and heating cycles - so far, so good. Keeping fingers crossed :-)
@JackJensenTrader
@JackJensenTrader 2 жыл бұрын
@@Rchelicopterfun Great stuff, with the video and now the update! Re: the Zebra, I'm looking at that, too (still troubleshooting my issue), but my thought would be it's easier to replace that than replacing a blown MOV, right? It would damage the MOV if it does its thing, correct? Re: troubleshooting, is the reason you didn't confirm you were getting correct voltage sent to the ECM because of the error code indicated that wasn't the issue?
@douglas787
@douglas787 6 жыл бұрын
15:40 price $600-$800 and about double in Canada. Not for me, when I run into a bad ecm motor I just add a couple relays and throw a regular two speed motor in and I'm done. Other techs might disagree with me but I just can't justify close to a grand for a motor especially when its just going to break again in a few years.
@justdissin7340
@justdissin7340 5 жыл бұрын
You should do a video on installing that basic motor & relays you use,i dont want to buy a ecm motor
@MrGarcon98
@MrGarcon98 5 жыл бұрын
i did the same back when they where newer ! in 2019 i dont know how its done , cause i am told we cant get the old motors anymore ? is what i am told ? so we pay lol
@andrewschulder1387
@andrewschulder1387 5 жыл бұрын
Hope your not doing this in Canada because if you are and you are liscensed. Be hopeful you don't get caught because you are altering how the equipment was certified and its against the mechancial and gas code
@andrewschoenfeldt5620
@andrewschoenfeldt5620 4 жыл бұрын
Thank you Sir. You made troubleshooting my unit a breeze. Quick, easy, cheap repair
@Rchelicopterfun
@Rchelicopterfun 4 жыл бұрын
Glad it helped.
@kittyfanatic1980
@kittyfanatic1980 2 жыл бұрын
You could de-pot the lower board for testing and component replacement. But if theyll cover a different module best to go that route.
@Mikecianfrocco
@Mikecianfrocco 5 жыл бұрын
I found bad return airflow will kill these motors. Change filters often and have someone check static pressure for bad duct flow
@garyangelstad5212
@garyangelstad5212 3 жыл бұрын
Say John, i have the same motor just replaced w a new mtr/cntrl. I figured it was the contoller but the factory parts guy said the whole unit was all they listed. Under the circuit board theres a connection between red and negative on the nearest capacitor. Looks like a fuse. Any way to replace that? That looks like the only spot but " dammit jim! I'm a plumber not an electrician!
@dankelley9361
@dankelley9361 2 жыл бұрын
Just a great how to video on saving tons of money and going thru the process of find a replacement ECM for your air handler. Is it standard that your blower runs of 240, or is that because of the ECM?
@Rchelicopterfun
@Rchelicopterfun 2 жыл бұрын
Hi Dan, that is a good question. Our furnace/air handling unit runs on 240V because it also has 20kW backup electric heating elements. Not sure if one without the electric aux heating would be 120V or also be 240V?
@pineychristian
@pineychristian Жыл бұрын
Good video. Yea you have the older 2.5 motor. Almost 99% of time the motor module is the problem. What sucks there are a lot of brands that wont sell the module by itself, so you end up buying the entire ECM motor / module.
@DonTownsendJr
@DonTownsendJr 6 жыл бұрын
Thank you for all the detail you covered here. Got me in my family back in the cool zone amongst this Texas heat. Appreciate you.
@sammartinez8896
@sammartinez8896 4 жыл бұрын
Great video, ordering a hd46ar265 tomorrow for my carrier unit, this looks exactly like mine. Happy to have found you just in time.
@Rchelicopterfun
@Rchelicopterfun 4 жыл бұрын
Glad I could help
@erichead021484
@erichead021484 2 жыл бұрын
I found a ecm that looks exactly like mines but im not sure if I can buy it may thermistor blew out and melted a bunch of stuff so I was gonna just replace the whole ecm to fix the issue but not sure if they call work the same
@euclon
@euclon Жыл бұрын
The device you referred to as a fuse/current limiter is actually a NTC thermistor... it limits the inrush current on initial power up... part number SL22 IR020... about 5$ on amazon...
@Rchelicopterfun
@Rchelicopterfun Жыл бұрын
Guess that's why I referred to it as a current limiter _"it limits the inrush current on initial power up"._ 😉
@nsideguy1
@nsideguy1 Жыл бұрын
Over the years the NTC thermistor have not always been the same for all 3x versions motor modules. Removing/attaching the line voltage connection to module with power still on, can also cause an arcking which could fail the thermistor. The way you tugged on the connector can also deform the pins, thus causing a poor or lacking connection. In general the fail due to power surges (lighting, poor earth ground or electrocuted squirrels). I was extremely impressed with your video. I dealt with the GE designed motor and its evolution for 33-years before retiring in 2018. The 1st generation motor was installed in a 1984 Carrier furnace model 58SXB. The pulse width modulator was separate and mounted on the back of the blower housing. In 1986 it was coupled with a variable speed inverter driven compressor A/C (38EV) or heat pump (38QV). The thermostat (Parker Electronics) was a DDC control that communicated to both indoor and outdoor unit just like your Bryant Evolution or Carrier Infinity system. The ECM (a.k.a. ICM) motor itself hardly ever fails. Failures are usually in the electronics or connections. Fan coils like yours, encounters a higher failure rate than gas furnaces. The electronics are in the cold air discharge of the fan during cooling, thus in high humidity conditions would condense water on the electronics and connections. There are 3-different modules 1/2, 3/4 and 1- horse power which are used in both 230vac fan coils and 115 vac gas furnaces. The modules will operate on both voltages. There is a jumper wire in furnace harness at motor to tell motor which input voltage. High efficiency motors were mandated by our federal politicians in 2018 just like the implementation of seat belts in cars. FYI starting in 2025 all new cars will be mandated to have a device to ensure the driver is not under the control alcohol.
@bobflyer4346
@bobflyer4346 5 жыл бұрын
Getting ready for new AC/gas Furnace replacement. Have the manufacturers improved upon the ECM Motors as of July 2019. I tolded the service personnel that are wishing to sell me new system that I would like to stay with PSC motors, they try and convince me that the current ECM motors are a big improvement. I am looking at ICP products, TempStar line (owned by carrier?). Went to even show me the add-on surge protectors you mentioned, which look like varistors or MOV's which run about 38 dollars u.s. Says they have not had any issues with the newer ECM's ?? Plus indicated that parts have 10 year warranty if I fill out paperwork within 60 days. I am in Northwest Florida, utility power issues all the time. Great video, also, I have been flying electric RC planes since about 2005, and related very good to the speed controllers used in RC. Even used to wind my own brushless motors. Thanks
@Rchelicopterfun
@Rchelicopterfun 5 жыл бұрын
All I can say is I will never get another furnace/fancoil with an ECM motor in it, if/when this one craps out for good. Complaints are wide spread, not just here but everywhere I look. When even a good number of honest HVAC techs are bashing them, you know there is an issue. The idea is sound (as we know from our 3 phase brushless RC motors), the main problem I see is the HVAC ECM industry has no competition. It would seem Genteq has a monopoly and as such, will charge whatever the market is willing to bear. No affordable Hobbywing or Castle Creations ECM's to choose from over premium priced Kontronic in the HVAC world ;-) Further, if you know you have dirty power issues in your area, then I would doubly stay away, even with extra external surge protection. Electronics are sensitive to voltage fluctuations, frequency shifts, and brownouts; not just surging. As for warranties, I come from the car repair industry and extended warranties for the most part are scams through and through - really read the fine print. You said the parts are warrantied for ten years, what about the labor & service call charges? Of course, this is all based on my negative anecdotal experiences and that of others. You could get one and never have a single issue with it. Certainly not every single ECM motor out there has a 100% failure rate. At least you know up front what you may be walking into. When we put this fancoil in our home, I was totally ignorant about them. My wife and I were just given all the sunshine and rainbows about how much electricity the ECM motor will save us and it's the latest technology. That's a laugh. Even doing all the repair work myself each time and sourcing cheap ECM's, I bet the money I spent on these POS's, wouldn't make up a lifetime's worth of the little extra it costs to run bullet proof, tried and true PSC induction motors. Hopefully someone else with positive anecdotal ECM experience/s will chime in here as well to give you a different perspective. An informed decision requires both sides of the argument to be presented :-) Hope you get a good system regardless of the motor technology :-)
@crueheads1
@crueheads1 5 жыл бұрын
@@Rchelicopterfun After dealing with my second ECM failure it two years and not willing to purchase another, I just picked up an $80 PSC motor and $15 fan relay, hooked the relay up to the EAC (electric air cleaner) points on the motherboard (so it cycles with air calls) spliced a few new wires into mains power for the fan and presto... Left all the old ECM wires just hanging and tucked out of the way... There is also the QwikSwap conversion boards that will restore variable speeds when using a PSC motor in an ECM furnace if you really want to restore the variable speed features and do a full conversion to a PSC motor... I did pick up a 3-speed motor so I have that option down the road, but for now, just using the motor on high with the relay and it just works... Under $100 and I no longer have to deal or worry with ECM failures and if the PSC motor fails, I can pick up any generic PSC motor and fire it right back up for under $100 with a readily available motor...
@Rchelicopterfun
@Rchelicopterfun 5 жыл бұрын
Going the relay and PSC conversion is a great option; unfortunately for communicating systems where the mother board in the furnace/fancoil is monitoring ECM communication, they won't work. A no motor signal fault will be triggered and put the unit into fault mode. Perhaps there is a way around this problem as well, but I've never come across it in over 4 years of looking.
@crueheads1
@crueheads1 5 жыл бұрын
@@Rchelicopterfun I could be wrong but it's my understanding that the QwikSwap board solution (instead of just a relay) should solve the communication problem if your furnace faults out, a little expensive yes, but still cheaper than a new ECM module/motor...
@Rchelicopterfun
@Rchelicopterfun 5 жыл бұрын
@@crueheads1 Thanks so much for this information. This would be the ideal long term solution! I'm definitely going to look into the QwikSwap V3 version because a quick looks shows it working with my particular unit. Oh I hope so. If (more likely when), I get one of these, I'll be sure to do an "update video". I can't believe I have not heard of these QwikSwap boards before. Search is obviously only as good as the search terms being entered :-) Thanks again for info - much appreciated!
@ianbrown1089
@ianbrown1089 5 жыл бұрын
Saved my ass! I have the exact same old module as yours. Thank you!
@zcarz2890
@zcarz2890 4 жыл бұрын
Nicely done John. Great info
@Rchelicopterfun
@Rchelicopterfun 4 жыл бұрын
Thanks 👍
@alializadeh5223
@alializadeh5223 Жыл бұрын
Thanks, John for putting this video together, very helpful. Can you put the link to the ECM and adapter that you got from eBay? mainly the adaptor. thanks
@Rchelicopterfun
@Rchelicopterfun Жыл бұрын
Sorry, can't find the eBay seller I used (changed their name or perhaps stopped selling on eBay)??? Ebay and Google Search are your friends.
@w.jamieward4498
@w.jamieward4498 4 жыл бұрын
Thanks.. I enjoyed the nerd level detail. Say Hi to all my Canadian relatives...
@alsing441
@alsing441 2 жыл бұрын
I also live in Canada and can not source a ECM-2 motor. Windings, furnace control board are OK. Likely the module is not working. I am wondering if I can convert my furnace to a PSC motor? American Standard AHU2bB060A9V3VBA with Emerson CNT06585 control board and EMC-2 Eon HD03 1/2hp motor. Cold in Canada.
@ericdorsey2262
@ericdorsey2262 Жыл бұрын
thanks for this great video. after discovering my blower motor was running non stop for yrs! i replaced the pc board on both the hvac units, blowers stopped yess! now after a yr, the upstairs units fan is running non stop again, this is when all is set to off. do you think its this ecm? i guessing I have one, need to look first.
@Rchelicopterfun
@Rchelicopterfun Жыл бұрын
I've personally never experienced or read about an ECM failure causing a constant running condition. When they fail, they to the best of my knowledge fail in a non-running condition. I am course not an HVAC tech; just going by anecdotal experiences and what I've researched.
@Jason-wc3fh
@Jason-wc3fh Жыл бұрын
It steps up the voltage because the capacitors are storing the voltage after the regulator at the Peak to Peak voltage of the AC waveform. When we measure just the AC voltage, we're getting an RMS reading that is not the peak to peak value of the waveform.
@Rchelicopterfun
@Rchelicopterfun Жыл бұрын
Yep
@user-ty2uz4gb7v
@user-ty2uz4gb7v 6 ай бұрын
I have an x13 from genteq, when I test from 1 to 2 or 2 to 3 or 3 to 4 or 4 to 5 I get open. I bought a brand new motor and I get the same result with a multimeter. Why don't I get a certain resistance reading between the windings?
@heavymechanic2
@heavymechanic2 4 жыл бұрын
Looking at your parts, its apparent it was re-engineered due to a high failure rate. The Heat Sink has the biggest advantage with the semiconductors which are known to fail due to poor heat dissipation on the tin cover. Kudos on saving money.
@zoltanszabo4825
@zoltanszabo4825 7 жыл бұрын
Hi, Many thanks for the great video...it seems I have the exact same controller configuration... could you please share the link to that helpful Ebay seller you purchased the 3.0 control unit from? Many thanks
@TCreatorO
@TCreatorO 2 жыл бұрын
Great video so far, but before you test for continuity, its always good to test your leads 1st
@MrRerod
@MrRerod Жыл бұрын
After replacing the thermister, a year later I thought I had a bad bearing in my carrier infinity inducer motor, but have determined the the main blower motor (GE 1/2 hp 08/22/00 CNO2 011DH7) is making a intermittent high pitched whine (g#5 note) when on first stage. I "think" it's related to the module, but not sure. Anyone? And rather than the Zebra Instruments ECM surge protector, is there a surge protector which would protect the entire furnace?
@mechmusicman
@mechmusicman 6 жыл бұрын
Thanks for a great video. 9 years ago I purchased a new Carrier Infinity Series AC unit. I’m down here in New Orleans where we run AC 12 months out of the year. We were painting the house and I suspect the painter may have used a drop cloth on the condenser unit. I got a high pressure fault on the thermostat. I soon found out about ECM motors. I looked everywhere but the ECM is not available for condenser fan motors. I have a friend who is a Carrier dealer and his cost for the motor is about $550. Ok, so I know I’ve saved money on electricity for 9 years now, but, have I saved enough to pay for these damn motors? I guess my blower has one like yours so maybe I should order the ECM 3.0 now for a spare. I’m not sure it’s worth it to buy these high efficiency units.
@johnfilardi
@johnfilardi 5 жыл бұрын
mechmusicman efficiency is expensive, am changing one today motor n board 700, about the time I write my ticket it’s a$ 1250.00 job
@Diaszurana
@Diaszurana 3 жыл бұрын
Depending on how often your unit is running, you very likely saved well over $550 over your last HVAC SYSTEM. However, what I mean by that is a power saving over your old whole system, not just from the blower itself.
@darcyschmidt1324
@darcyschmidt1324 3 ай бұрын
John, where can we find the service bullentin DSB 09-0001? I was unable to find it. Thanks!
@hphan6486
@hphan6486 Ай бұрын
Were you able to find the service bulletin?
@michaelmorassi4953
@michaelmorassi4953 5 жыл бұрын
One thing I don't think I heard you mention, a new motor/controller is factory programmed to your air handler. Hope everything has worked well since.
@Rchelicopterfun
@Rchelicopterfun 5 жыл бұрын
I didn't mention it, since that is not the case with the 2.5 or 3.0. They don't have unit specific programming. There is certainly more than one sub-version as I mention at time index 19:22, and the importance of getting the correct or superseded part number. Yes, this used 3.0 is still working well in my system going on 2.6 years now and I have another used 3.0 GC08 for backup. However, as I state in my pinned comment at the top, I'll likely be getting one of Mainstream Engineering's QwikSwap V3 PSC converter logic boards and fit a good old conventional 3 speed PSC motor when this ECM craps out. The piece of mind, and cancellation of my unwilling subscription to the false economy of the residential HVAC ECM gravy train should be worth it :-)
@carllungwitz5171
@carllungwitz5171 2 жыл бұрын
Did you verify proper rotation? I didn't observe the motor doing its rotation routine.
@Rchelicopterfun
@Rchelicopterfun 2 жыл бұрын
Considering it's been working fine for over 5 years now, I would suspect it's turning the correct way.
@yeliab814
@yeliab814 3 жыл бұрын
thank you for making this- awesome video!
@Rchelicopterfun
@Rchelicopterfun 3 жыл бұрын
Glad you liked it
@mchristofas
@mchristofas 3 жыл бұрын
I have a goodman with a 1hp ECM 2.5 motor i installed in 2006. I got away with replacing the thermistor about 5 years ago but this time i had to order the 700 replacement motor (updated version) Checking the ohms on the windings of the old motor, one of the fields on the motor reading is way off from the others. The goodman site said the new motor is pre programed but do you happen to know if it was not would the motherboard automatically upload the program? Your video is one of the best i found so far on this topic! Thank you! I'll follow up with when i install the new motor.
@Rchelicopterfun
@Rchelicopterfun 3 жыл бұрын
The main board doesn't or can't flash firmware into the ECM's. That is something only the manufacturing facility is capable of doing at time of production. If the new motor/ECM replacement you got states it works in your specific application, it should be fine.
@jenko701
@jenko701 Жыл бұрын
PCS conversation best money option , these things are supposed to save you money on power , and they do for the short time they work . The more complex they make this stuff, the more the cost of staying cool or worm go’s up . Best longe term option go low efficiency and save money over all by not having problems for decades.
@Rchelicopterfun
@Rchelicopterfun Жыл бұрын
So true. As the engineering adage goes "complexity hampers both execution and reliability."
@boogerhead0
@boogerhead0 6 ай бұрын
Do you know the differences between the ECM 2.3 an ECM 2.5 16-pin pinout?
@thatcaddyguy2374
@thatcaddyguy2374 2 жыл бұрын
John thanks for the video and information!
@Rchelicopterfun
@Rchelicopterfun 2 жыл бұрын
🙂
ECM Multi-Speed Blower Motor Troubleshooting!
16:40
AC Service Tech LLC
Рет қаралды 332 М.
PSC Motor vs Constant Torque Motor vs Variable Speed Motor | Comparison Video
13:46
Fox Family Heating and Air Conditioning
Рет қаралды 101 М.
REAL or FAKE? #beatbox #tiktok
01:03
BeatboxJCOP
Рет қаралды 13 МЛН
It’s all not real
00:15
V.A. show / Магика
Рет қаралды 18 МЛН
Wall Rebound Challenge 🙈😱
00:34
Celine Dept
Рет қаралды 22 МЛН
FINAL EXAM BEE  C24 BY ASK ENGINEERING ACADEMY COMMON TO C21 C18
1:21:18
ASK Engineering Academy
Рет қаралды 9 М.
Replacing an X-13 ECM motor with a PSC (capacitor) motor.
25:29
HVAC Companies HATE That You Can Do This Yourself.
25:51
The DIY HVAC Guy
Рет қаралды 604 М.
Popping a 5000A Fuse
18:42
Photonicinduction
Рет қаралды 6 МЛН
ECM Motor Troubleshooting
10:26
Enertech University
Рет қаралды 117 М.
Thermistor repair of the ECM motor
4:31
grayfurnaceman
Рет қаралды 30 М.
TEF #156 | GE ECM 2.3 DG02 Teardown And Failure Investigation
53:04
That Electronics Fool
Рет қаралды 7 М.
The VZREP ECM Repair Kit
4:39
Zebra Instruments
Рет қаралды 44 М.
REAL or FAKE? #beatbox #tiktok
01:03
BeatboxJCOP
Рет қаралды 13 МЛН