ECM Multi-Speed Blower Motor Troubleshooting!

  Рет қаралды 298,804

AC Service Tech LLC

AC Service Tech LLC

Күн бұрын

In this HVAC Training Video, I Show How Several ECM Multi-Speed Fan Motors Work and How to Troubleshoot Them to Determine the Problem. I Show Measurement Voltages, What Should Happen, and Where to Visually Inspect. Blower Motor Won't Shut Off, Blower Won't Turn On. Blower Ramps Up and Down. ECM Motor Terminal Wiring. Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
Tools Used In The Video
UEI DL479 Multimeter With Temp Sensor amzn.to/2jtsUbJ
Magnet Jumpers- amzn.to/2PyKPQZ
Alligator Jumpers- amzn.to/2PxqJXn
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos/Articles
ECM Multi-Speed and Variable Speed Blower Motor Troubleshooting Playlist:
• ECM Blower Motor Troub...
Full Blower and Fan Motor Troubleshooting Playlist: • Troubleshooting HVAC F...
• HVAC ECM Variable Spee...
• Testing ECM Variable S...
• How to Troubleshoot a ...
• Step by Step Procedure...
• Step by Step Troublesh...
• 240 volt PSC Blower Mo...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicetech.com/store
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicetech.com/hvac-ca...
Our Newest Articles: www.acservicetech.com/articles
Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
Our Other Resources: www.acservicetech.com/resources
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicetech.com/tools
Our Tool List on Amazon: www.amazon.com/shop/acservice...
Support the Channel by purchasing tools through TruTech Tools!
Use this link www.trutechtools.com/?aff=8
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.com/show/74KXLz5...
Apple Podcasts: podcasts.apple.com/us/podcast...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided. ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #blowermotor #blowermotor #multispeed #troubleshooting #diagnosis #ECM #ecmmotor
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Пікірлер: 285
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
The E-Book, Paperback and Quick Cards: www.acservicetech.com/store The Paperback, Quick Cards at Amazon: www.amazon.com/shop/acservicetech Support the Channel- www.patreon.com/acservicetech Tool List- www.amazon.com/shop/acservicetech Related Videos: ECM Variable Speed Genteq 3.0 Troubleshooting: kzbin.info/www/bejne/oqDGf6lvjNiUpKM Make Your Own ECM Genteq 2.3 Tester: kzbin.info/www/bejne/onzWepqgeq93f6s Variable Speed Motor Testing: kzbin.info/www/bejne/ooCYgXSoh6tsqMk PSC 120v Motor Testing: kzbin.info/www/bejne/nJ3FhqeCgsqGhbM PSC 240v Blower Motor Testing: kzbin.info/www/bejne/q3m7qGullL6ikM0 PSC 240v Blower Motor Wiring: kzbin.info/www/bejne/a3ishZqph9KGkJY Tools I Use Are Linked Below! Leak Detection: Accutrak VPE Ultrasonic Leak Detector amzn.to/2nFYKVe Accutrak VPE-GN Ultrasonic Leak Detector amzn.to/2Zy4IZP RectorSeal Bubble Gas Leak Detector - amzn.to/2ckWACn Vacuum Tools: JB 6 CFM Vacuum Pump - amzn.to/2nqbvo8 CPS 4 CFM Vacuum Pump - amzn.to/2DxgPwY Appion Valve Core Removal Tool - amzn.to/2uYr8WL Appion Blue 3/8" to 1/4" Vacuum Hose - amzn.to/2uYlVyc Appion Red 3/8" to 1/4" Vacuum Hose - amzn.to/2uYg6Ro Yellow Jacket 1/4" by 1/4" 3’ hose - amzn.to/2umtcod Appion 1/4" by 1/4" and 3/8” hose - amzn.to/2Zyxzx9 Uniweld 1/4" by 1/4" 2’ hose - amzn.to/2GFov1Y CPS Vacuum Micron Gauge - amzn.to/2v1nM3O Supco Vacuum Micron Gauge - amzn.to/2v1JRiA JB Vacuum Pump Oil - amzn.to/2mGrlXy Checking the Charge: Yellow Jacket Refrigerant Gauge Set amzn.to/2aenwTq Refrigerant hoses with valves amzn.to/2aBumVI Yellow Jacket Gauge set & hoses amzn.to/2vLVkV9 Yellow Jacket 4 Port Manifold w Hoses amzn.to/2BkuGIq Digital Refrigerant Scale amzn.to/2b9oXYl Ratcheting Service Wrench amzn.to/2dGV4Nh Fieldpiece SMAN380 Digital Manifold Set amzn.to/3297zse Fieldpiece SMAN480 Digital Manifold Set amzn.to/337mGnq Compact Ball Valve for Refrigerant Hose amzn.to/2KUisW8 QuickDisconnect 90 for refrigerant hose amzn.to/2MMtVcg RectorSeal Bubble Gas Leak Detector amzn.to/2ckWACn Fieldpiece ST4 Dual Temp Meter amzn.to/2wc1ME3 Fieldpiece Bead K Type Temp Sensor amzn.to/2DBwKfs Fieldpiece Wet Bulb Temp Sensor amzn.to/2RRI7Tw Fieldpiece TC24 Temp Clamp amzn.to/2qHLyjZ Flaring Tools: Yellow Jacket Flaring Tool - amzn.to/2OBxGlM Spin Flaring Bits 1/4", 3/8", 1/2", 5/8", 3/4"- amzn.to/31BCs8Z Yellow Jacket Flaring Tool with Set Depth - amzn.to/2QIKsQH Yellow Jacket Torque Wrench - amzn.to/2NRR68Q Uniweld Swage and Flare Kit- amzn.to/2T55jyn Nylog - amzn.to/2MLJcch Ridgid Tubing Cutter - amzn.to/2DnjjR1 Wolverine Tube Reamer - amzn.to/2QGLyMV Swaging Tools: Manual Copper Tube Swage/Expander- amzn.to/2WRPa1M Spin Swaging Bits 1/4" to 7/8" for the Drill- amzn.to/2YQwwqS Uniweld Hydraulic Swaging Tool- amzn.to/2MlrI8m Uniweld Swage and Flare Kit- amzn.to/2T55jyn Uniweld Hammer Swage kit- amzn.to/2CzWMMU Uniweld 3/4" Hammer Swage- amzn.to/2CzXsSs Uniweld 7/8" Hammer Swage- amzn.to/2Mja5WE Uniweld Multi-Size Hammer Swage- amzn.to/2T3Cx1b Brazing Tools: Air Acetylene Torch setup - amzn.to/2aQalsb 15% Silver Brazing Rods - amzn.to/2gVLyLc Uniweld Cap-N-Hook and #2 Tip Oxy Acetylene Torch Setup - amzn.to/2STp3Fe Ameriflame Oxy Acetylene Torch Setup #1 &#2 Tip - amzn.to/2SRm3JF #2 Tip for Oxy Acetylene Torch - amzn.to/2SPDaeD Cap-N-Hook Tip for Oxy Acetylene Setup - amzn.to/2MbhpUk 40cu B Tank to 10cu MC Tank Acetylene Tank Fitting - amzn.to/2GxZZPi Nitrogen Regulator - amzn.to/2bXdR5f Uniweld NitroVue Flow Regulator - amzn.to/2GnsaAo Uniweld Nitrogen Flow Meter - amzn.to/2brvoBg Bernzomatic Trigger Start Lighter Propane/Mapp Gas - amzn.to/2vit0cv Uniweld Soft Flame Sweating Torch Setup for Acetylene - amzn.to/2DyzRD8 Flint Spark Ignitor - amzn.to/2L3P2u9 Stay Brite #8 Silver Bearing Solder and Flux - amzn.to/2XIDJsY Aluminum Braze Rods - amzn.to/2IGNMu Electrical Diagnosis Tools: UEI DL389 Multimeter amzn.to/2xAdaJf UEI DL479 Multimeter with temp sensor amzn.to/2jtsUbJ Magnet Jumpers- amzn.to/2PyKPQZ Alligator Jumpers- amzn.to/2PxqJXn Irwin Wire Stripper/Cutter/Crimper amzn.to/2dGTj2V Nitrogen: Uniweld NitroVue Flow Regulator- amzn.to/2GnsaAo Uniweld Nitrogen Flow Meter amzn.to/2brvoBg Nitrogen Regulator amzn.to/2bXdR5f Service Valve & Port Access: RectorSeal Bubble Gas Leak Detector - amzn.to/2ckWACn 25 Valve Cores - amzn.to/2L37UJU 25 ¼” Brass Port Caps with rubber O-rings - amzn.to/2GIOdD2 Brass Valve Core Tool which holds 3 valve cores - amzn.to/2GFEbm2 Valve Core Torque Wrench - amzn.to/2GHiLoD Locking Cap Universal Lock/Unlock Tool - amzn.to/2GGAoVp Locking caps - amzn.to/2GFXZ8A Ratcheting Service Wrench amzn.to/2dGV4Nh Yellow Jacket Sealright 90 Coupler- amzn.to/2LsU1V7 Yellow Jacket 1pk Compact Ball Valve- amzn.to/2uXdF18 Yellow Jacket 3pk Compact Ball Valve- amzn.to/2AiKfQe Thumb Screw Valve Core Depressor with Backseat- amzn.to/2mR0sCL Other tool links can be found in the video description section. Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal- www.amazon.com/shop/acservicetech
@samuelneil7490
@samuelneil7490 2 жыл бұрын
I dont mean to be offtopic but does anyone know a tool to log back into an Instagram account?? I somehow forgot the login password. I love any tricks you can give me!
@xavierleandro188
@xavierleandro188 2 жыл бұрын
@Samuel Neil instablaster ;)
@samuelneil7490
@samuelneil7490 2 жыл бұрын
@Xavier Leandro thanks for your reply. I got to the site through google and im waiting for the hacking stuff now. Takes a while so I will reply here later with my results.
@samuelneil7490
@samuelneil7490 2 жыл бұрын
@Xavier Leandro it did the trick and I actually got access to my account again. I am so happy:D Thanks so much, you really help me out !
@xavierleandro188
@xavierleandro188 2 жыл бұрын
@Samuel Neil no problem :)
@johndoe-wt4ui
@johndoe-wt4ui 4 жыл бұрын
Nobody at my job can teach me any of this 🤦‍♂️ I have to go to KZbin your channel to learn how to be a hvac Service Tech it’s frustrating man thanks ac service tech
@eclipse369.
@eclipse369. 4 жыл бұрын
Most technicians are part changers. Learn all you can :)
@TheOneshot78
@TheOneshot78 4 жыл бұрын
Read books and learn on your own..we are in a field that never stop learning. Also go to Expos and trade shows. Any training you can go too do it.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
We all just try to invest in ourselves as best we can. Thanks John Doe for letting me know! I am glad that the videos are helping in your current situation!
@benjamindyer7348
@benjamindyer7348 3 жыл бұрын
I agree, must of my co workers are great at what they do but they don't know the real deep details on how this stuff works
@kidernie7
@kidernie7 3 жыл бұрын
Dammm I did a service call and the motor kept spinning even tho the ts was off, now I know why thanks boss couldn’t help that day 🤨
@Armand9100
@Armand9100 Жыл бұрын
I bought a Genteq 5SBA39FLP8013 ECM blower motor to replace the Broad Ocean motor which stopped working in my air handler. The Genteq is an X13 with 5 speed taps as shown in the video. I decided to test it before going to the trouble of mounting it in the air handler. I laid it on its side next to the air handler and connected the wiring. The thermostat was set to fan only. When I turned on the power the shaft began to spin for about 1 second and shut off and then a few seconds later it came back on and shut off and continued this pattern until the power was shut off. My neighbor's son in law is a HVAC technician, so I called him and explained the problem. He told me that the motor detects the load that is on it and adjusts for that load to maintain a steady speed. It needs to have the blower wheel on it and be mounted in the blower housing in order to detect a load. I installed it in the air handler and it works perfectly. I don't know why this information is not in the video and why the motor in the video is not showing this problem.
@orangetuono38
@orangetuono38 Жыл бұрын
HELLYA! Paid $85 for a service call for the guy to lie to me about the issue. Watched AC Service Tech video, got the skinny, back up in the attic troubleshoot to a likely blown Cap on the ECM module, order an exact replacement off Ebay for $82. 3 hours of YT videos, 1 hour to Trane shop to be denied, 1 hour surfing Ebay, then 10 minutes mounting replacement ECM and I'm UP AND RUNNING! It was a total of 6 screws to fix!! You saved me $2400!!!!!!!!!!!!!!!!!!!!!!!! Signed up for Patreon. I'm not an HVAC pro so would have preferred a one-time payment.
@hliz8818
@hliz8818 3 ай бұрын
Your machine could have been out off warranty. You were paying parts and labor. Did you know it was the blower motor BEFORE he got there? I'm glad you fixed it. But don't bash the tech. Most of the time the company sets the prices..we just do our part and diagnose issues for customers.. plus it's an attic. Salute
@orangetuono38
@orangetuono38 3 ай бұрын
@@hliz8818Company, Tech or both, they tried to get $2500 for the blower replacement or better yet a $8000 full system replacement. It's a year later and I'm out $75 in parts and my HVAC is running great. I spent more time watching this video than the repair took. If that's how you "just do our part" you might want to think about how you sleep at night.
@EyeForKnowledge.
@EyeForKnowledge. 2 жыл бұрын
I got myself into the trade watching KZbin. AC service tech knows their stuff. I started at an apartment complex as a groundskeeper and within two years I was lead tech. Now, I’m in residential working for a really good company that really doesn’t have time to train. Most companies don’t have the resources (especially in todays economy with everything getting so expensive), to send two techs to a house so one can learn. So you either start as a helper making $10/hour where you’ll be on install or you learn the stuff and go in making $30/hour on service. Learn this stuff. You won’t be rich but you’ll make a comfortable living. I’ll be moving into industrial and commercial soon. We do commercial now but I’m looking forward to working on more complicated things like chillers and oil heaters.
@acservicetechchannel
@acservicetechchannel 2 жыл бұрын
Really cool Steve! Thanks for sharing!
@ToughCowboy
@ToughCowboy 2 жыл бұрын
Unbelievably helpful, THANK YOU!!! I literally got 2 quotes - one was for $3,850 to replace motor and ECM and the other company said there was not available replacement available and said I absolutely MUST buy new unit which was $10-12k. I just replaced the motor and ECM with parts from Supply House for $750. However, from your video I figured out that it was the inrush current limiter that had blown and bought new component for $5.07, so will either save as backup or sell used but working on eBay and probably get $200-300 of my money back, I would have sure paid it.
@tooftaker
@tooftaker Жыл бұрын
Where did you find the inrush current limiter?
@brunoshvac2578
@brunoshvac2578 3 жыл бұрын
Thanks for sharing Craig. I tell all my trainees to watch your videos. It’s amazing what this industry has become with everyone sharing information thanks to people like you putting in the time. Great video sir!! 😎
@kr4awkr4aw5
@kr4awkr4aw5 Жыл бұрын
I LOVE KZbin!!!!! The motor on my furnace went out. An AC/Heat company said it would cost over two thousand bucks to fix it, due to the type of motor ECM. which cost around 1500.00 dollars. So like always I went to youtube to see how hard would it be to replace the motor. To my surprise, there were many videos showing how to do it. Looked pretty simple to me. I found a place that sells rebuilt motors and found exactly what I needed for $300 dollars no tax or delivery charges. Just got the motors and fixed my unit in less than two hours, most of that time was cleaning the furnace. The wife is happy and I am very happy. Thank you, KZbin you're the best!!!
@Raulito9
@Raulito9 2 ай бұрын
What site was it?
@rb5875
@rb5875 4 жыл бұрын
Your electrical troubleshooting videos have been helping me on a daily basis, and your book has been a huge help in the field for me to look back on instead of calling my techs. It would be amazing if you made a book on electrical troubleshooting, having a good guid handy really helps out in a jam for a newbie on call lol
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thank you very much for letting me know and I would very much like to in the future, thanks!
@jesseduenes7380
@jesseduenes7380 2 жыл бұрын
Thank you so much for the information on this ECM. I'm a maintenance technician at a retired community and I have ran into some problems with some of my air handler blower with this ecm. So watching this video gives me a little more information on what to look for. Again thank you for your fine work & information!
@samuelvalenzuela4541
@samuelvalenzuela4541 3 жыл бұрын
These are the best HVACR videos around the world from AC Service Tech, congratulatuons from México
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad you are enjoying the videos Samuel!
@Eddy63
@Eddy63 4 жыл бұрын
Excellent explanation Craig ... I wish you were around 40 yrs ago ... Lol ... Happy 2020 ...
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks a lot Eddy!
@hvacdoc2338
@hvacdoc2338 4 жыл бұрын
Great explanation !! I’ve been in the field for many years and still learn a lot from your videos.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Absolutely, I wish I had all the online training, articles, and videos when I started. I could have learned a lot faster when I started in the trade, thanks!
@ericbrobst5591
@ericbrobst5591 4 жыл бұрын
Great imformational video. Had an X-13 motor running constantly, without 24v, about a month ago. I replaced the entire motor. I was unaware untill watching this video that you could replace the module only. Your videos are always helpful.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks Eric!
@acheatdoctor
@acheatdoctor 4 жыл бұрын
I was just diagnosing one of the ocean broad motors yesterday, this video was right on time. Kudos
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Nice, thanks!
@earlguillory5168
@earlguillory5168 2 жыл бұрын
I see a lot of ECM motors on Fan powered boxes (VAV's) and this is the best video with explanations I have seen to date. Usually, the factory recommendation is to use the "Tech-Mate" adapter and call it good. Thanks for the great video.
@Cl4rkTheShark
@Cl4rkTheShark 2 жыл бұрын
If you replace an ECM motor and it is ramping up & down... make sure the blower is turning the right way. Thanks for the video!
@jashua2089
@jashua2089 3 жыл бұрын
Thank you all HVAC school members for these great lessons.
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad you like them!
@coydog6665
@coydog6665 8 ай бұрын
Congratulations Shawn on the marriage, I wish you and your wife a lifetime of happiness. Brother I’ve been following from the beginning and will continue to follow your videos. I enjoy the way you approach content and then share it. Semper Fi brother!
@pointblank6467
@pointblank6467 3 жыл бұрын
This was the most detailed explanation of these motors I have ever seen. Thank you so much!
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad you enjoyed it!
@derf_the_mule1405
@derf_the_mule1405 Жыл бұрын
Some of the X13 controllers have an OFF Delay (30sec-3min) built in. My ComfortMaker (Carrier) does this. The only way to stop it is replace the control board without the OFF delay.
@stevehiggins9338
@stevehiggins9338 10 ай бұрын
Perfect explanation and understanding of how to service these motors. I have been trying to find something like this for a while now and you nailed it. Thanks man.
@acservicetechchannel
@acservicetechchannel 10 ай бұрын
Thanks for watching!
@jiangbian76
@jiangbian76 4 жыл бұрын
The best video for troubleshooting the ECM, thank you!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks J. Bian!
@Deus_Ex_Machina.
@Deus_Ex_Machina. Жыл бұрын
Thank you! You're a saint for bringing this secret information to the people! And to clearly explained. The manufacturers and installer/dealers are in cahoots to make it hard for the owners of the appliances to handle their own hardware failures. I don't much like situations where early failures bring profit to someone else, after I shelled out for the equipment. I'm not saying everyone should try this at home, but if you are technically educated, it's nice to have the simple facts so you can take care of issues.
@michaelcolgan3182
@michaelcolgan3182 Жыл бұрын
This was an excellent description on how these work. Thank You
@stuzman52
@stuzman52 4 жыл бұрын
Great information Greg! Just to add another tidbit of information, I had purchased a generic X13 preprogrammed ECM motor, but the motor ran backwards. There are three stator windings which are very similar to a 3-phase motor. One can cut any two of the three wires on the connector going to the stator windings, reverse the leads and the motor will run in the reverse condition. I don't recommend this, but it will work as I've done it to get a unit to work. Fortunately, the motor speed was very close to the original.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Nice, thanks Stuzman!
@Zeknix
@Zeknix 2 жыл бұрын
Some of those motors have a way to program it to reverse the direction of the motor. Also, the motor is a three phase motor, but that doesn't mean you can hook it up to three phase straight from the breaker panel as a temporary work around. I tried this as a last ditch effort to get the AC blowing again, and the windings started to cook. We were over 80 miles offshore so getting a replacement wasn't going to be quick. Thankfully, the field had a crew boat that was making a run to the beach for resupply the next day.
@DIYDaveT
@DIYDaveT 10 ай бұрын
Excellent vid. IT would be nice to know what application of the 24 VAC motor speed control signal actually do, and how one goes about "programming" which speeds are active. It is clear from your vid that only 1 control signal is to be applied at a time. What if the air handler controller feeds 2 at a time?
@benbernank1341
@benbernank1341 10 ай бұрын
I found the same thing… a Goodman system feeds 24v to 1&2 when heating or cooling and 24v to just 1 with call for “G” alone…
@superiorcomfortheatingairl3373
@superiorcomfortheatingairl3373 4 жыл бұрын
You always do great training videos, but this one is one of my favorites. Unfortunately I have already ran across a OEM replacement motor that was programmed wrong, not for sure if it was the manufacturer or the distributor (lot of distributors are able to program motor with OEM specs). Since the motor was under warranty, the service call was negative profit for labor.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Sorry to hear that and yeah we need to be very well versed with the things we tend to run into. Thanks for letting me know Superior!
@bryantylerservices
@bryantylerservices 4 жыл бұрын
Excellent explanation on ECM motors diagonis / test for continuity and ground.. And on module itself! Great video ,Craig ! Bryan Tyler Refrigeration
@jackpast
@jackpast 4 жыл бұрын
Great hands-on, Craig!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks Jack!
@patbrock7460
@patbrock7460 2 жыл бұрын
I live in the Chicago area, lots of supply houses, but on a Saturday night at 100 bucks + an hour the bill can be ridiculous. I've also had supply houses be out of stuck. I always carry a standard PCM motor for older style motors. At -10 outside the people don't want to hear you'll be back tomorrow if you can find the part. So, I will install the PCM motor and hot wire it low for heat and high for AC.to give them service. I know some guys that carry an old working motor just to give service and you can take your time getting the right part. I carry a 1/2 hp. does 1/6 thro 1/2 and 90% of my calls.
@markit8dude321
@markit8dude321 Жыл бұрын
I just started out in this field and luckily I have been lucky enough to work with someone who has 30 + years experience.. But he will make the time to teach you if you’re interested and trying. Not trying to wast time
@oscarestrada5509
@oscarestrada5509 3 жыл бұрын
He's very nice and very good explain ed I have 6 yes in the field and I've still learned with this man other thing.you are doing well thanks
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Awesome, thank you!
@williampaul8979
@williampaul8979 4 жыл бұрын
A great video as always. Keep doing what you do best !
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks a lot William!
@JuanTodoli
@JuanTodoli 4 жыл бұрын
Good one. Happy new year Craig.
@Craig1967
@Craig1967 2 жыл бұрын
Great video! Too bad most control modules are potted. I do component level repairs on just about everything, so it bothers me when manufactures make things disposable. I liked that you said that the MOV is replaceable. Hopefully some technicians will have good soldering skills and will replace them rather than swapping out the module and/or motor. I have worked on some large 3 phase VFD drives for big commercial air handlers, and most of the time its poor soldering and capacitors. The VFDs that I work on are external, and are not potted. Of course there are no schematics, so it is sometimes a challenge. Keep up the great work. Your book is great - I purchased it about a year or so ago. Thank You.
@chuckcraigs9310
@chuckcraigs9310 Жыл бұрын
could a bad mov cause the motor to continuously run or is that likely something else in the module?
@mr.airservicesllc1373
@mr.airservicesllc1373 2 жыл бұрын
Great video on ECM's, I hope you put out more video's on Broad Ocean and Rescue motors (maybe you did already??). I would change your explanation on the motor potentially overheating if there's an airflow restriction because motors draw less current with an obstruction (less work as your not pushing as much air - less work = less amperes). I subscribed, looking forward to watching more technical videos!
@brianrott921
@brianrott921 Жыл бұрын
Catus Maximus! ...I've got a variable speed blower motor went bad so thanks for the info
@richardleveson6467
@richardleveson6467 Ай бұрын
Thanks for this. The industry charges huge margins for relatively inexpensive parts from Mexico or even China and then we get charged double that by the less scrupulous service technicians. Here in Canada things are worse as the parts suppliers won't sell to the public. I fixed my furnace blower for $25 (cost of five thermistors plus overnight Fedex from DigiKey) after being quoted $1,500 for a new unit. I wish I could find a tech like the creator of this video but, sad to say, they are few.
@mannyfilmsinc
@mannyfilmsinc 2 жыл бұрын
awesome video, thank you so much for sharing... would you be more incline to replace just the module or the whole motor on an ECM Genteq , if the motor is constantly running....
@MrCRYLATINO911
@MrCRYLATINO911 3 жыл бұрын
This was a very helpful video my gosh. Do you happen to have a video showing the step by step to swapping an ECM motor to a PSC motor that you would typically carry on the truck?
@meyerjeff
@meyerjeff 3 жыл бұрын
Only to add that the “in-rush current limiter” you point to in the electronics module is called a Metal Oxide Varistor - and as you said, can be field replaced with relative ease.
@patmason7276
@patmason7276 3 жыл бұрын
Ac company came to fix our unit thought it was the blower assembly, then the board find out the yellow wire to the thermastat had voltage on it all the time. Swapped with another extra wire in the harness everything is good.
@anvibrimel41
@anvibrimel41 4 жыл бұрын
Thanks a lot for this lesson you are awesome and I already have your book but I going to get your quick cards reference,thanks
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Awesome to hear Angel! Thanks!
@joshuaainsworth5440
@joshuaainsworth5440 2 жыл бұрын
I have a carrier unit with the broad ocean ecm you have in the video. I have had an issue 3 times now where all of a sudden when the ac turns on the inducer/blower motor doesnt turn on. The first time I got it working, but to be honest not sure what I did is all I did was test just like you said and when I hooked back up it worked like nothing had ever happened. It then did it again several months later. I was out of town but the wife and kids were at home and I just called an hvac tech to come and look at it since I couldn't trouble shoot. I had the wife simply kill power to the whole unit and when the tech got their the next day he flipped the power back on and it worked with no issues. Basically paid him for a trip to come to my house and turn it on. Well now it has been about 6 months since hat time and it has done it again. Of course I am out of town, but I will trouble shoot when I get back. Sorry for being such long winded but wanted to give you as much info as possible. So you have any idea why it would be intermittently not working. Why would it not work then when turned off for a period of time or when testing it it just all of a sudden works like normal again. I had thought the first times were due to power surges and actually installed a whole house Honeywell surge protector about 3 weeks ago so it wouldn't happen again. This last time, today my wife said there were not any power surges. Any help would be appreciated.
@batso-felik3436
@batso-felik3436 4 ай бұрын
You may have an intermittent problem with that blower motor. That means it’ll work when it wants to and it won’t work when it wants to. That’s a sign of a bad module or blower motor or both.
@RockoRocko-rz7kx
@RockoRocko-rz7kx 4 жыл бұрын
Great video. Thank you for sharing your knowledge
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks a lot Rocko99!
@bobrebera494
@bobrebera494 3 жыл бұрын
always a great reference tool-thanks my friend
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad you liked it!
@fahadsheikh5374
@fahadsheikh5374 Жыл бұрын
Thank you for your guidance and explanation , keep it up 👍
@alsera9063
@alsera9063 2 жыл бұрын
Excellent video tutorial! Thanks!
@marcusdarnell3348
@marcusdarnell3348 4 жыл бұрын
Thanks Craig! Happy 2020!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks a lot Marcus, you too!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks a lot Marcus, you too!
@sonle-fz1xb
@sonle-fz1xb Жыл бұрын
Great video! Thank you so much.
@borshardsd
@borshardsd Жыл бұрын
Another great share! Good content from your team always 👏
@acservicetechchannel
@acservicetechchannel Жыл бұрын
Glad you think so! Thank you for watching!
@zadvindersingh4234
@zadvindersingh4234 4 жыл бұрын
Honestly a great video great teaching abilities 👍👍
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
I appreciate that!
@gregoriomatos3935
@gregoriomatos3935 4 жыл бұрын
can`t explained any better.great content
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Much appreciated!
@xelaju8
@xelaju8 4 жыл бұрын
Thanks for the video. Very useful.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Glad to help, thanks!
@johncasale2195
@johncasale2195 2 жыл бұрын
Excellent in detail
@broncheemims8493
@broncheemims8493 4 жыл бұрын
Thanks Craig for the info
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Glad to help Bronchee!
@E85_STI
@E85_STI 2 жыл бұрын
I’m about to graduate from HVAC course but my IBM went out and the tech that came out did a resistance test on the module and he said it was at 18 ohms but normal limits should be between 10 and 20 so he said it was starting to fail. He replaced the whole blower with a new one that didn’t come with a module on it. So I’m the future I can check the resistance of the motor itself without dealing with the module although the module is cheaper to replace than a motor.
@bobrebera494
@bobrebera494 4 жыл бұрын
great video and easy to understand-thanks
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks Bob!
@syn-techcooling7282
@syn-techcooling7282 3 жыл бұрын
Well done. You are a master!
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Thank you very much!
@eliblanchard9178
@eliblanchard9178 Жыл бұрын
This is a great video. Thanks so much.
@andresmurillo5117
@andresmurillo5117 4 жыл бұрын
Excellent video, thank you for share you knowledge.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Glad it was helpful!
@ricardofuentes2153
@ricardofuentes2153 Ай бұрын
Great video! Plenty knowledge
@jayecheverria2454
@jayecheverria2454 Жыл бұрын
Awesome video👍
@noealeman8527
@noealeman8527 4 жыл бұрын
Thank you!! Awesome video like you always do .
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks for watching!
@javiercalvillo4865
@javiercalvillo4865 2 жыл бұрын
Thanks 🙏🏽it was really helpful 👍🏽
@BackFire10mm
@BackFire10mm Жыл бұрын
Great video! Thank you Sir.
@chungjorgen6522
@chungjorgen6522 2 жыл бұрын
I love you man . You are the best .
@boogerhead0
@boogerhead0 2 жыл бұрын
My ECM had magnets detached from the rotor. Cleaned off the junk glue film remaining on the rotor and magnets, and re-affixed them with epoxy, original orientation, spacing. Motor working fine again. Thank GE, Beloit and Junktek or whoever owns this now Genteq for stupid glue application. Even multirotors have the magnets arranges so they cannot be thrown off.
@coldfinger459sub0
@coldfinger459sub0 4 жыл бұрын
Awesome detailed explanation.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks t lech!
@enduringpromise
@enduringpromise 3 жыл бұрын
Great information. Thank you!
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad it was helpful!
@joem3384
@joem3384 4 жыл бұрын
I appreciate your help Very helpful knowledge
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks Joe!
@valdemarbenavides3274
@valdemarbenavides3274 10 ай бұрын
Great informative video. Just had a question. When my ecm is plugged in, it’s hard to turn by hand but when I disconnect the ecm. It moved freely. Does this mean I have a bad ecm or bad blower? Should I just replace both?
@royabreu3627
@royabreu3627 Жыл бұрын
Good explanation,thx,what would be the case if the motor cycle off and on,this will be the module or the motor,thx
@brianlittle717
@brianlittle717 2 жыл бұрын
What voltages do you expect to get out of the module and is there a way to connect power to the motor for temporary without the module? Maybe some type of universal module you can pop in there until you get the new part?
@donnierobertson3088
@donnierobertson3088 3 жыл бұрын
Great job and video like always
@acservicetechchannel
@acservicetechchannel 2 жыл бұрын
I appreciate that
@harryappliancesrepair8587
@harryappliancesrepair8587 Жыл бұрын
thanks bro i,m always leaning alot new things
@tube8533
@tube8533 8 күн бұрын
Great video!
@life_is_miserable
@life_is_miserable 3 жыл бұрын
Great video! I have a Rheem 70-101729-03, if I want to replace it with another model which one should I purchase? And can you make a video on the wiring from the x13 to the transformer and the control board? Thanks.
@zekenzy6486
@zekenzy6486 4 жыл бұрын
Great video. Thank you for sharing. Happy New Year . What is different and the same between ECM motor and Variable speed motor ?
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
A variable speed can modulate the speed up and down depending on the gas output stage of a furnace where as an ecm multispeed as very specific speeds. However, both are quieter than PSC motors at startup, thanks!
@zookeroni1834
@zookeroni1834 3 жыл бұрын
beautiful explanation
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Thanks for liking
@enrolledregistrar103
@enrolledregistrar103 Жыл бұрын
Awesome thank you very much
@manolinrosales9640
@manolinrosales9640 Жыл бұрын
Excelent explanation!
@matthewedwardsnyder
@matthewedwardsnyder 2 жыл бұрын
You are a saint. Thank you so much man.
@hashimwaheed4906
@hashimwaheed4906 4 жыл бұрын
Can you pls do a video on two-stage compressor (working/troubleshooting)
@jimk.8783
@jimk.8783 Жыл бұрын
Thank you
@user-dq8wg8kn4o
@user-dq8wg8kn4o Ай бұрын
Which book you recomend to get more knowledge about furnace & ac unit sir 👌🙏🫵🫶 your videos. Indeed your are a great master
@bluebeastgamer3005
@bluebeastgamer3005 3 жыл бұрын
You are the best 👍👍👍
@ApartmentMaintenance
@ApartmentMaintenance 4 жыл бұрын
Great detailed video 👍 Where would you purchase a new inrush current limiter if that was bad ?
@pizzle1011
@pizzle1011 4 жыл бұрын
Amazon has them
@samersam1933
@samersam1933 2 жыл бұрын
Thank you sir nice explanation👏🏻
@acservicetechchannel
@acservicetechchannel 2 жыл бұрын
So nice of you
@apisglider9
@apisglider9 Жыл бұрын
Good afternoon. I have a Lennox xc17 that is now out of warranty and in need of it's 4th ecm motor. I am considering replacing it with a psc motor and a relay. However, to keep things simple I am also considering the rescue ez13 motor as a replacement. What are your thoughts regarding the ez13 and it's reliability? Also will I still be able to use the Lennox lcd thermostat that came with the xc17 if I switch to the psc? Thank you and any help is appreciated.
@baggins1
@baggins1 2 жыл бұрын
Excellent
@AndTodaysProjectIs
@AndTodaysProjectIs 4 жыл бұрын
Your video is friggin awesome! I have been dealing with problem #2 (the pulsing up and down of the speed of my GE 2.3 ECM 3/4 HP MOTOR 5SME39SL0674 for the last 14 months. In your video you explain that IF the motor is still in the squirrel cage that it might act different than in your video. I'm listening to my a/c run right now as I type. When it comes on initially it comes on soft and then slowly ramps up to full power, then suddenly drops down low to almost as if it was OFF but it is still blowing air out of the vent if you put your hand up there to test...then ramps up to full power again. Up and down about 3 to 5 times per cooling cycle (about 5 to 10 minutes typically). Does that sound about right for it possibly being the ECM module on the back of the motor? I have already replaced the main system control board AND replaced the actual blower motor with the exact same results still. Thanks again for posting. I feel confident that you have isolated my problem with this video already.
@sknight0391
@sknight0391 4 жыл бұрын
Great Job 👍
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks Shannon Knight HVAC!
@professorkiwi
@professorkiwi 4 жыл бұрын
Very helpful! Thank you!
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks Kiwi HVAC!
@mewonderwhy
@mewonderwhy Жыл бұрын
First of all your videos are great. I don’t usually subscribe but I felt compelled to do so after watching two of your videos. What is the expected resistance 1/2 Hp 208/230V X13 motor. I’m getting 12.9 ohms on all. Sorry I’m sure you already answered in comments here or elsewhere but I don’t see how to search comments.
@leonelgamez3302
@leonelgamez3302 3 жыл бұрын
Thanks.. good explanation.!!
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad it was helpful!
@michaelcostello6991
@michaelcostello6991 3 жыл бұрын
Does it matter which wire you use for the common of the low voltage. Is it marked on the transformer ??
@mohammedalobaidi9981
@mohammedalobaidi9981 2 жыл бұрын
Thank you sir.
@petesingh292
@petesingh292 3 жыл бұрын
I used tech pro and I got the ecm motor running so should I replace the circuit board because it’s not getting 24 volts signal? Plz Craig reply
Air Handler Control Board Operation and Troubleshooting!
5:01
AC Service Tech LLC
Рет қаралды 81 М.
3M❤️ #thankyou #shorts
00:16
ウエスP -Mr Uekusa- Wes-P
Рет қаралды 11 МЛН
Sigma Girl Past #funny #sigma #viral
00:20
CRAZY GREAPA
Рет қаралды 31 МЛН
Получилось у Вики?😂 #хабибка
00:14
ХАБИБ
Рет қаралды 7 МЛН
I’m just a kid 🥹🥰 LeoNata family #shorts
00:12
LeoNata Family
Рет қаралды 20 МЛН
ECM Motor Troubleshooting
10:26
Enertech University
Рет қаралды 109 М.
Replacing an X-13 ECM motor with a PSC (capacitor) motor.
25:29
PSC Motor vs Constant Torque Motor vs Variable Speed Motor | Comparison Video
13:46
Fox Family Heating and Air Conditioning
Рет қаралды 85 М.
ECM X13 Blower Motor Troubleshooting!
8:07
AC Service Tech LLC
Рет қаралды 192 М.
Thermistor repair of the ECM motor
4:31
grayfurnaceman
Рет қаралды 26 М.
How To Check Fuses With a Multimeter
0:34
Ward Wrenching
Рет қаралды 243 М.
Genteq Variable Speed Constant Airflow ECM Troubleshooting 101
11:23
WHY CAPACITORS FAIL in Air Conditioners! Watch it Break!
9:45
AC Service Tech LLC
Рет қаралды 1,4 МЛН
3M❤️ #thankyou #shorts
00:16
ウエスP -Mr Uekusa- Wes-P
Рет қаралды 11 МЛН