How to Connect Poly Pipe to ANYTHING using Barbed Fittings

  Рет қаралды 314,434

R.C. Worst & Co., Inc.

R.C. Worst & Co., Inc.

Күн бұрын

Chris shows you how easy it is to connect Polyethylene (black plastic pipe or poly pipe) to just about anything using barbed fittings. In the video, he uses a stainless steel insert fitting with male NPT threads (Male Adapter). Barbed insert fittings are also available with female NPT threads (Female Adapter) and with barbed threads (barbed coupling).
View or purchase these fittings: www.rcworst.co...
If you need more information or assistance with products, call 855.329.4519 or email Customer.Service@RCWorst.com to speak with an industry expert. Thanks for watching!
Add us to your professional network: www.linkedin.c...
Follow us on Twitter: / rcworst
Like us on Facebook: / rcworst
For more industry videos visit our KZbin Channel: / @rcworstwater
Check out our website: www.rcworst.com/
We are a distributor of pumps, packaged pumping systems, on-site wastewater treatment equipment, on-site wastewater treatment systems, and custom electrical control panels for water and wastewater applications, water well supplies, drilling supplies, and water treatment equipment.

Пікірлер: 148
@geoffhess2267
@geoffhess2267 Жыл бұрын
Exactly what I needed to get a leak-free result when replacing a poly pipe to barbed connector on my swimming pool. Attached and tightened while warm. Excellent!
@isovideo7497
@isovideo7497 Жыл бұрын
I used a face cloth folded twice and wrapped around the end of the pipe, and then held in place by an old trouser bicycle clip. Then I poured boiling water on the cloth, waited for a couple of minutes for the heat to dissipate through the thickness of the pipe, and then was able to insert the barb! A heat gun also works, and is gentler than a blowtorch.
@mikerudenko3539
@mikerudenko3539 5 ай бұрын
Thank you x 10000000000!!! I’m abt to run 2000 ft of this pipe (500 ft rolls) - needed to see this video!
@MrVARhythm
@MrVARhythm 8 ай бұрын
Thanks! Great video and weirdly enough one of the only ones I could find on YT
@somaday2595
@somaday2595 2 жыл бұрын
Added note: RE Getting to tightening the hose clamps quickly, the PE expands about 8 times as much as steel, so tightening the clamps while the PE is still warm will tighten the fitting even more when cooled.
@artlathers3746
@artlathers3746 3 жыл бұрын
Thanks for the help. Had no idea how to do this. Now I can connect my garden! Cheap money too.
@RCworstwater
@RCworstwater 3 жыл бұрын
Glad I could help!
@bullrunhunter6489
@bullrunhunter6489 Жыл бұрын
I use a wagner hot air gun it works great without weakening or damaging the tubing. I also like to use single ear compression clamps because they get the full 360 degrees when you compress them. Similar to a CV boot and can be compressed with any small to medium end cutting pliers.
@jb791505
@jb791505 Ай бұрын
Thank you. This is the tutorial I needed.
@RCworstwater
@RCworstwater Ай бұрын
Glad it was helpful!
@The56Kaveman
@The56Kaveman 5 жыл бұрын
Super helpful! I was trying to get that bloody barb fitting in for ages, I think I just want heating it up enough.
@holdurhorse9149
@holdurhorse9149 Жыл бұрын
It looks way too easy in shop , how about splicing a poly pipe inside pit hole with minimum space ?
@JenniferSmith-bv3zk
@JenniferSmith-bv3zk Жыл бұрын
This was so helpful! I have been trying to connect a garden hose to a huge polypeptide to make a pool heater! And I have leaks! I am about to go try this! Tha KS for sharing.
@randyjerrett3385
@randyjerrett3385 11 күн бұрын
Nicely done!!!
@RCworstwater
@RCworstwater 9 күн бұрын
Thank you! Cheers!
@truongutctdynnvt
@truongutctdynnvt 3 жыл бұрын
It's pretty a good way that I'm looking for, different from the ordinary way
@VitorMadeira
@VitorMadeira 6 жыл бұрын
This was quite e tremendous help. Thank you so very much. Greetings from Portugal.
@RCworstwater
@RCworstwater 6 жыл бұрын
Obrigado
@zosoo7
@zosoo7 2 жыл бұрын
I appreciate the info. However one question I have is what are (if any) the manufacturer's guidelines? I can't seem to find any information on the poly I'm using. I'm working with 3/4" poly rated for 100 psi. I used the torch method and sure enough I have a slow drip. Short of torching too much or too little, I don't know what I could have done wrong, which leads me to question the torching method if the margin for error is that small. After all, heating plastic changes the molecular structure, does it not? So I'm really curious if the manufacturers have a recommendation on whether the torch method should be used.
@westleywilkes2078
@westleywilkes2078 2 жыл бұрын
As long as they don’t have to fight. Thanks Judge
@ricosaurus
@ricosaurus 2 ай бұрын
Maybe my pvc barb fittings weren't long enough for my 2" poly pipe, but the joint isn't strong enough and keeps coming apart on a hillside even if I crank down the hose clamps. Couldn't find the double barbed stainless steel insert at RC Worst.
@RichardLisboa
@RichardLisboa Жыл бұрын
Thank you... Very good information.
@ricos4700
@ricos4700 4 ай бұрын
How tight will the fitting be once it cools? Can it still spin? I have the sdr 9 1" poly, and it's like 7/8 " ID, which is odd. I used 3/4". Once I heat and clamp, will there be any issues?
@genevelis6075
@genevelis6075 5 ай бұрын
I wonder if you have answers to my questions: 1) Just today, the plastic barbed fitting broke off inside the poly pipe. How to take it out? 2) The poly pipe comes from the well house/pump, about 4' before house foundation it was connected to the Galvanized pipes and a hydrant. All of it rusted and needed to be replaced. Should I use Pex or copper? Pipes in the crawlspace are copper. 3) I also Thinking to lower the pressure tank and connect to the pump about 10' - 15' under the ground to eliminate heating well house in the winter season. My pipe runs about 6' under the ground. A) is it a good idea? B) how to do it? 4) Should I install another pressure tank under the house in the crawl space? The well is about 30 yards away from the house. Also I found a 5" PVC well pipe in the field. PVC pipe broken, leveled with the ground. What to use to close it, to prevent from debris to fall down? How to find if it has water and how deep? Also what camera to buy to inspect the well? What 4" pump and water tank brands and models are best?
@goldenratio5117
@goldenratio5117 2 ай бұрын
Can you heat pvc like this to connect it to galvanized??? My well outflow is going to be plummed galvanized outflow burried into pvc...
@kurtbarrett6785
@kurtbarrett6785 5 жыл бұрын
This is awesome! I've always used compression type unions for repairs on poly pipe, but for some reason up here in the Seattle area I can't find any over 3/4in to save my life. That leaves me stuck with the damn barbed, clamp on style and I'll be damned if I could force the pipe over the effing fitting.
@RCworstwater
@RCworstwater 5 жыл бұрын
Glad we could help! We do sell the compression fittings as well if you need them: www.rcworst.com/Fittings-c79.html?Attribs=481
@JesseAdamson
@JesseAdamson 5 жыл бұрын
I'm in Seattle and they have the compression ones at McLendons Hardware store, and then you can probably get them at specialty plumbing suppliers like Pacific Supply.
@kurtbarrett6785
@kurtbarrett6785 5 жыл бұрын
@@JesseAdamson Hey Jesse, Thanks for the reply, I appreciate the advice! I'm actually in the Redondo/Fed. Way area, so since I wrote this I had tried McLendon in Sumner and Kent with no luck. Next time I will give the one in Seattle a shot and although I can't read the name again at the moment, I will definitely give the other place you mentioned a try. Thanks to the video, I did manage to make the barbed fittings work pretty easily this time around.
@browntrousersmoment
@browntrousersmoment 4 жыл бұрын
Fantastic video!
@RCworstwater
@RCworstwater 4 жыл бұрын
Thanks!
@davidback4524
@davidback4524 4 жыл бұрын
Their videos are fantastic and very well done. If you call them they are very helpful and they carry a full assortment of well items. I'm curious if the barbed fitting was placed in ice if that would help?
@RCworstwater
@RCworstwater 4 жыл бұрын
Heating the poly pipe is going to required either way. I don't see how cooling the metal would help.
@bradsimard7357
@bradsimard7357 5 ай бұрын
doesnt look like the barbed fitting has a collar to spin? how do you connect to the female if can not spin to thread on? looking for an better solution to connect and disconnect my pumps to my sand point wells. thanks!
@robertmillstein8916
@robertmillstein8916 3 жыл бұрын
Very helpful. Thanks.
@MarkMcPeak5895
@MarkMcPeak5895 3 жыл бұрын
Good video. Thanks for lesson!
@historygradstu
@historygradstu 3 жыл бұрын
do yo guys recommend pinch clamps? if so what is a good brand to use?
@admorison
@admorison Жыл бұрын
I have to replace a barbed elbow on the hose coming from my well pump that connects to the pressure tank. How do i relieve the pressure in the line before removing the hose clamps?
@demokratiaperemoje
@demokratiaperemoje 3 жыл бұрын
That's MAP not propane, but great video!
@roberthaynes7674
@roberthaynes7674 2 жыл бұрын
Super helpful video! I need to connect HDPE Pipe to 4" grooved steel sprinkler pipe. Do they make a fitting for this??? I havent been able to find anything!
@Honestandtruth007
@Honestandtruth007 2 жыл бұрын
Great idea and Well done. 👍👍
@DaisyHollowBooks
@DaisyHollowBooks 5 жыл бұрын
Very useful!
@forestfairness12
@forestfairness12 3 жыл бұрын
thanks for a good video demonstration... i have been searching high and low online for brass or plastic shut off valves (with barbs on both ends) that will fit a one inch (inside diameter) black poly pipe... i have found them for smaller diameter pipe, but can't seem to find one inch size... any idea where i might look??? thanks
@bosdad7
@bosdad7 5 жыл бұрын
Great tips, Thank you !
@RCworstwater
@RCworstwater 5 жыл бұрын
Thanks for watching! :)
@dctorres210
@dctorres210 3 жыл бұрын
Thank You for the info.
@RCworstwater
@RCworstwater 3 жыл бұрын
You bet!
@manonboyer3718
@manonboyer3718 2 жыл бұрын
Can you tell me the max. dimension différence IT should be between the ID of the pipe and the OD dimension of the bar sectionnelle
@manonboyer3718
@manonboyer3718 2 жыл бұрын
Barb section. Because I tried to fit a 1.50" pipe on a 1.50" barb connection and there us a diffirence of .150" on one of m'y pipe, and a other one , .090". IT was impossible to Do. Thanks for a answer.
@kenneth.handsome3443
@kenneth.handsome3443 4 жыл бұрын
Thanks it's a big help
@RCworstwater
@RCworstwater 4 жыл бұрын
Glad to hear that!
@pcofranc
@pcofranc 4 жыл бұрын
what about replacing rusted steel or iron where the pipe must be cut - weld new threaded fitting on ? Epoxy, Clamp?
@jamescole3152
@jamescole3152 3 жыл бұрын
Never heard of this. Is this recommended by the manufacturer? I have used hot water but the pipe was only 3/4 inch.
@jacobjordan7644
@jacobjordan7644 5 жыл бұрын
Ty this is a good help out
@anasantiago-akyurek5435
@anasantiago-akyurek5435 3 жыл бұрын
What happens if the black pipe is set on fire to be able to insert the fitting. That is what I saw the pool repair guy do? Will the pipe cracking or leak when I run the filter? Help???
@clovehitch1854
@clovehitch1854 Жыл бұрын
So I'm 6 feet down (frost) replacing an old leaking plastic 1" tee (installed years ago by previous owner)with a brass T. Plastic is not up to code and I do not want it to leak again so am using brass. My helper thought it was smart to dig a hole as small as possible. Do not do this, you risk a cave-in and there is not enough room to work. I've always used hot boiling water, would not recommend a torch as once the plastic seems heated enough it will continue burning/melting after the torch is shut off. Against my better judgement, egged on by my "assistant" I melted the hose using a heat gun, deformed the end of the pipe. I have heated and worked with plastic for 40 years, believe me it can be easy to FU. I'm going to just cut the tee off as it is too difficult to get enough torque on a tee and it would groove up the interior wall of the pipe with all the twisting and turning. So off to the big box store miles away (the one that put the local hardware store out of business) to get the Tee I saw that has an extra long barb in one direction. As far as the politics, didn't watch it. I did learn from my high school WW2 vet teachers (in both Pacific and European theaters) how to identify Hirohito and Hitler type leaders. We've got one here in the US right now who combines the worst of Hirohito and Hitler. Pretty sure those vets would have said his name begins with a T, not a B.
@WiSeNhEiMeR-1369
@WiSeNhEiMeR-1369 Жыл бұрын
Howdy R.C.-W&C, ... Is there ever any advantage to utilizing a TEFLON Pipe Dope to the BARBS - as a Lubricant or Sealant ? YES ? / NO ? / reasons PRO or CON Thanks COOP ...
@RCworstwater
@RCworstwater Жыл бұрын
No, do not put pipe dope on the barbs. You can use food-grade lube or dish soap.
@robbropyro3283
@robbropyro3283 5 жыл бұрын
Thank you
@RCworstwater
@RCworstwater 5 жыл бұрын
Thanks for watching!
@Rc51gemini900
@Rc51gemini900 2 жыл бұрын
Thanks
@RCworstwater
@RCworstwater 2 жыл бұрын
Welcome
@andymcmurry6948
@andymcmurry6948 2 ай бұрын
Can you show me how to do this upside down in the bottom of a 4’ hole with water trickling out of it during a blizzard with no electricity or gas
@andymcmurry6948
@andymcmurry6948 2 ай бұрын
Good video btw 👍🏻
@joeltemplin3570
@joeltemplin3570 2 жыл бұрын
Will this work for the CTS (OD) poly as well as the IPS (ID) poly? The dimensions are kinda goofy on this poly stuff. There's way more CTS available but fittings are limited unless I can heat up the pipe enough to take a barb.
@sweetiepienumber1
@sweetiepienumber1 6 жыл бұрын
That makes perfect sense compared to other info I have read/watched... I have 1" HDPE I think it's 200 or 250 psi and I need to connect to a 1.5" polypropylene sink trap tailpiece. Any thoughts? Thank you.
@RCworstwater
@RCworstwater 6 жыл бұрын
You would want a 1" insert x 1" NPT and a 1" x 1.5" bushing. If the sink trap has female threads then that's all. If it has male threads you'll need a 1.5" Coupling as well. Here are links to buy all 3: www.rcworst.com/BII-SSMA-100-Stainless-Steel-Male-Adapters-1-MPT-x-1-INS-p2174.html www.rcworst.com/304-Stainless-Steel-Bushing-1-50-x-1-p5074.html www.rcworst.com/316-Stainless-Steel-Merchant-Coupling-1-5-p8091.html
@bob15479
@bob15479 9 ай бұрын
What if the inside of the pipe has bubbles from being super old?
@johnbarron4265
@johnbarron4265 4 жыл бұрын
Can this barbed fitting be used inside metal drain pipes as well? If so, how would you go about sealing the connection?
@RCworstwater
@RCworstwater 4 жыл бұрын
No, it is for poly only.
@pauldow1648
@pauldow1648 6 жыл бұрын
Not the worst I've seen.
@joschae8080
@joschae8080 3 жыл бұрын
Can you use copper fittings?
@sammyg3697
@sammyg3697 7 жыл бұрын
Nice work
@RCworstwater
@RCworstwater 7 жыл бұрын
Thanks!
@mukundsrinivas8426
@mukundsrinivas8426 3 жыл бұрын
hey man.. i need to connect a 2mm pipe to a square tank. can i do this with barbed fittings?
@John98512
@John98512 4 жыл бұрын
Is there an option to have the barbs on the outside of the pipe rather than the inside? I don't want the barbed fitting to reduce the flow. Thank you.
@RCworstwater
@RCworstwater 4 жыл бұрын
Good question! The other option is to use a ford fitting: kzbin.info/www/bejne/qHSkhqGAnNBrgLM
@MGSpangler
@MGSpangler 4 жыл бұрын
I have a 3/4" brass barb coming out of a gate valve after my water meter. It turns to a 3/4" poly line leading to my house right after the gate valve. The barb just slides right in for some reason. Almost as if it's not even touching. Would this work with that situation or should I get another type of barb fitting that isn't brass? I'm currently trying to find out why I'm only getting 25psi from my meter, so the pressure may go up to 100psi in the future if it's an issue with the city's equipment. Thanks in advance for any help.
@Altenurgy
@Altenurgy 3 жыл бұрын
I've got 1-1/2" SDR-9 pipe and a 1-1/2" barb x MPT adapter. The OD of the pipe is just a little bit smaller than the OD of the fitting. I'm going to really to soften up the pipe so doesn't look like the torch is going to work. It looks like I should be using a 1-1/4 or 1" barb. Maybe someone else has had this problem and knows what I'm up against? Thank you
@ThirdDayGuitarFan
@ThirdDayGuitarFan 6 жыл бұрын
Do these barbed fittings rust? Or are they stainless? I'm needing to pipe 1000ft of drinking water from my well to a large 1000gallon poly tank, and I want to be sure the connections dont rust on me. Should I use brass? How long do the connections last?
@RCworstwater
@RCworstwater 6 жыл бұрын
We sell brass and stainless, we like to go with stainless because the barbs go a bit deeper into the pipe. I'd say the fitting should outlast the pipe, 20+ years or so.
@ThirdDayGuitarFan
@ThirdDayGuitarFan 6 жыл бұрын
R.C. Worst & Co., Inc. Thanks! Will check out your site
@percybrown9191
@percybrown9191 5 жыл бұрын
I have a Barb fitting that measures exactly one - what size pipe can I get to connect with that Barb
@doityourself6429
@doityourself6429 5 жыл бұрын
OK I got some good info I never knew, however, my problem is removing these fittings after they are installed. Any tips? Thanks!
@bosdad7
@bosdad7 5 жыл бұрын
re-heat them and remove them. however the pipe end will be deformed and not be any good for reconnecting to a fitting. I suggest you simply cut them out with a hack saw and if it need's be extended add a splice barbed connector and a small piece of poly pipe to the end.
@justthinkalittle8913
@justthinkalittle8913 5 жыл бұрын
Can heated Polyethylene pipe be stretched around a larger barbed insert. I have a 1" barbed fitting and two Polyethylene pipe options. #1) The ID of one Polyethylene pipe is .87" and #2) ID of the other Polyethylene pipe is 1.097. what one should I choose for a well pump application?
@RCworstwater
@RCworstwater 5 жыл бұрын
What size are the poly pipes? 1" and 1.25"? You should use the same size insert fittings as your pipes.
@bosdad7
@bosdad7 5 жыл бұрын
1 1/4 inch is the smallest I would go on any well application. most are 1 1/2" or 2" for maximum water flow.
@thepoolboy6136
@thepoolboy6136 3 жыл бұрын
Can I use a heat gun?
@f1fanatic80
@f1fanatic80 6 жыл бұрын
Can this black poly piping be used as a replacement to a corroded copper line from the meter to the main valve to the house? Is pet better than poly for this use and how deep should they be buried down?
@richardj5417
@richardj5417 3 жыл бұрын
If you are asking these questions please don't do it. Lol
@sojournsojourntraveler1203
@sojournsojourntraveler1203 4 жыл бұрын
I got away from the high dollar couplings a long time ago just using the next size smaller threaded steel pipe .
@alabastardmasterson
@alabastardmasterson 4 жыл бұрын
Do you use a reducer fitting?
@sojournsojourntraveler1203
@sojournsojourntraveler1203 4 жыл бұрын
No and the pipe threads hold the pipe inside. NO HEAT REQUIRED for connecting / thread in if needed./ snug fit. When using them with hot water I use metal hose clamps on the outside so there is metal on both sides of the plastic, It works well. Try it you will like it. Ps you probably know there is a food grade poly if needed .
@alabastardmasterson
@alabastardmasterson 4 жыл бұрын
@@sojournsojourntraveler1203 appreciate the response. I should've asked if you just step the size down and run the size down. Thanks
@sojournsojourntraveler1203
@sojournsojourntraveler1203 4 жыл бұрын
Yah just the the threaded nipple about 2.5" to make the connector . Happy trails . Peace and Shalom
@williamdarby9011
@williamdarby9011 4 жыл бұрын
Can you explain what you mean? What type of pipe do you use as the fitting.I need to connect 2 inch DR11 and I need 2 inch male pipe threads
@thesarbot9502
@thesarbot9502 6 жыл бұрын
You are oxidizing the poly with an open flame, wouldn't a heat gun be better ?
@RCworstwater
@RCworstwater 6 жыл бұрын
This is a great question that I think warrants a followup video. I spoke with the factory that manufactures our poly pipe, they said that oxidation does not occur until the pipe is heated to over 425 degrees. He also mentioned that it is generally not a worry when you're using a torch because the pipe is soft enough to work with long before 425 degrees. Keep an eye out for our followup video!
@margueritewhilden7551
@margueritewhilden7551 6 жыл бұрын
great vid. Question: in low pressure situations must the pipe be heated first? I wish to go from black poly to PEX, have all the barb fittings and clamps, but do not have torch. Can I get by with just clamps? Many thanks
@RCworstwater
@RCworstwater 6 жыл бұрын
Thanks for watching! You will have a very tough time trying to insert the barbed fitting without heating the pipe. Also, when the pipe cools it "constricts" on the barbed fitting. If you can somehow manage to insert the fitting without the torch, just clamp it down and check for leaks.
@margueritewhilden7551
@margueritewhilden7551 6 жыл бұрын
Many thanks! Also, good advice for the positioning of the clamps for proper fit. Thanks again for reply.
@bosdad7
@bosdad7 5 жыл бұрын
Use a heat gun, they are cheap and easy to find. or grab the wife's blow dryer and use it. it will take a little longer but will achieve the same results. if you still have none of these item's. you can dip the end of the pipe into a pot of boiling water to help soften the poly pipe. If you still have no way to do this,,, call a friend that has a blow dryer.
@stcharleshometheater
@stcharleshometheater 2 жыл бұрын
What type of fitting did you use for the poly to pex since they have different inner dimensions?
@nzmak3220
@nzmak3220 6 жыл бұрын
blow torch is overkill.. i prefer heat gun
@desert1cop
@desert1cop 6 жыл бұрын
Heat gun is ok unless your outside on wet grass or working where a pipe has broken and soaked the area,Butane won't electricute you
@johnturney5721
@johnturney5721 5 жыл бұрын
@@desert1cop bammmm
@diverwa
@diverwa 3 жыл бұрын
Whats the max psi on the joint?
@Kodababoda
@Kodababoda 5 жыл бұрын
What about CRT Poly Pipe? I can get that type pipe much cheaper but supposedly they require high $$$ Ford Couplings?
@leorexwinkle683
@leorexwinkle683 3 жыл бұрын
Is it possible to re-make the connection if need be?
@RCworstwater
@RCworstwater 3 жыл бұрын
Yes
@vipleather
@vipleather 6 жыл бұрын
Is that pipe rated for a deep well. If not what kind of pipe do I use for a 100 foot static. I think my well has galvanized pipe and I what to replace to something lighter
@RCworstwater
@RCworstwater 6 жыл бұрын
Thanks for the question! We actually have a video on Selecting Drop Pipe, check it out: kzbin.info/www/bejne/jXe1qKOHjNSNqM0
@mikewilliams-no9cm
@mikewilliams-no9cm 3 жыл бұрын
What's the proper fitting to mate poly pipe to a deep well jet pump?
@RCworstwater
@RCworstwater 3 жыл бұрын
We use long-barb insert fittings: www.rcworst.com/Fittings-c79.html?Attribs=476&
@michaelkuzmin
@michaelkuzmin 3 жыл бұрын
On 1/2 poly pipe, can I use 1/2 PEX clam rings instead of these more expensive screw clamps?
@richardj5417
@richardj5417 3 жыл бұрын
I wouldn't
@michaelkuzmin
@michaelkuzmin 3 жыл бұрын
@@richardj5417 not the same diameters?
@richardj5417
@richardj5417 3 жыл бұрын
@@michaelkuzmin pex rings are better suited for cheap pex. Honestly I would use hose clamps and a 60inch/lbs T handle torque wrench. Being a plumber myself. Lol by setting torque you get guarantees with the clamps that you won't with pex rings and yes the well line or polyethylene is a heavier schedule or tubing.
@juandelacruz1520
@juandelacruz1520 4 жыл бұрын
cris can i use heat gun instead of torch thank you.
@RCworstwater
@RCworstwater 4 жыл бұрын
You might be able to, it will just take much longer.
@AztecWarrior69
@AztecWarrior69 3 жыл бұрын
will a heat gun work? Well that depends on the quality of the heat gun. So yes it can be done. Also it is much safer and actually takes LESS time. Not like this guy says. Why? Because you can apply direct heat to the pipe and not have to keep doing this touch and go. You can make a fitting to that heat gun out of metal conduit and a cap. Cap the EMT and drill holes all the way around near the cap and about an inch wide band of holes. Now you can stick the new heat gun attachment you just made inside the pipe and heat it just at the end and on the inside where it matters the most. It will only take seconds even with a cheap heat.gun.
@roblewis4306
@roblewis4306 Жыл бұрын
I've had different issues in the past dealing with 3/4" poly pipe. After much trial and error, I've found that brass barbed fittings seem to work the best with the size pipe that I have along with the two clamp technique. Steel and plastic barbed fittings are just plain terrible. I can't believe after all these years of companies manufacturing and people using this stuff that no one has come up with a better way of connecting and securing fittings to this type of pipe. The worm clamps seems to a major fail point.
@nigeljames536
@nigeljames536 4 жыл бұрын
. Don't know if it works. Did nothing to test after, if you are going to show something take it to the end???
@hermanjamers
@hermanjamers 3 жыл бұрын
So it is too hard to get the barbed fitting in without the heat first? Suppose you could get the fitting on. If you are using a metal fitting then it stands to reason that perhaps you could heat the metal fitting from the inside and it would melt the polyethylene pipe from the inside and make a bond there. Heating the outside of the pipe with the clamps already on would also melt the clamps to the outside of the PE pipe. I'll stick with your method rather than experiment. But I'll be under my home connecting a 1" Brass insert male adapter to 1" polyethylene of iron pipe size with rated working pressure of 200 PSI per my water company's web site. I'll probably wear an OVE glove on each hand underneath a pair of waterproof gloves.
@RichardKinch
@RichardKinch 3 жыл бұрын
It would be better to force the metal barb into the warm (not hot) pipe to press it in, but the force required to do that is still impractical. Poly pipe is slippery, and there's no way to hold it for that degree of press fitting. Heating the metal fitting is a bad idea. That will melt and reform the plastic, which will be loose when it cools.
@jassdsu
@jassdsu 3 жыл бұрын
Seems like way too much heat. The pipe is now compromised.
@RCworstwater
@RCworstwater 3 жыл бұрын
It may seem like too much, but we have been hanging pumps from these connections for 30+ years with no issuse.
@RichardKinch
@RichardKinch 3 жыл бұрын
*Yes!* I admire the Worst guy and everybody else who gets this done, but a 3596 deg F propane-air flame is overheating, scorching, and destroying the polyethylene material strength. You only need 200 deg F to soften it, and any more will spoil it. Worst has gotten away with this for 30 years because he's playing around the flame to minimize the damage, there's enough material there to hold up despite being degraded, and the damaged pipe area is bandaged by the metal clamps and not under water pressure.
@graybriley
@graybriley 6 жыл бұрын
Why don’t you just buy poly pipe compression fittings that are made for the job .
@RCworstwater
@RCworstwater 6 жыл бұрын
We do sell those as well, but for the cost many contractors opt for insert fittings since the compression fittings are easily 10x as expensive.
@smjlemay
@smjlemay 3 жыл бұрын
The absolute worse thing you can do is apply a flame to Polyethylene pipe!! Don't do this!!! Your pipe will get brittle and crack.
@chrismagnum2710
@chrismagnum2710 2 жыл бұрын
Then how????? If the poly pipe is coming up out of a slab you can't dunk it in boiling hot water
@Dewanzaur09
@Dewanzaur09 3 жыл бұрын
Oh dear god, you heated that way too much and had too high a heat. Also, heat the inside more than the outside. You can ruin your connection by having the outside too hot. I don’t care about the outside being as hot as the inside. The inside is where it all matters. Also, remember, that poly continues to heat itself even after you remove the flame.
@davidl2281
@davidl2281 2 жыл бұрын
And he basically only heated one side, when he went to side he wasn't standing by he left heat on it for about 5 seconds total, while the other side was almost melting, lol
@thomashocker2792
@thomashocker2792 2 жыл бұрын
Next time put gasoline on the pipe to get it ready for the torch.
@johng8049
@johng8049 Жыл бұрын
and for gods sake please use stainless steel fittings I swear the number of times i find leaks at joints and the clamp is rotted away SMH
@butchtheiw
@butchtheiw 2 жыл бұрын
1st hafl of video- man heats pipe. Could've done without about 2 minutes of that.
@lostinmyspace4910
@lostinmyspace4910 5 жыл бұрын
Damn virgin pipe. I feel her pain.
@AztecWarrior69
@AztecWarrior69 3 жыл бұрын
This is "A" way of doing but NOT the "Proper" way of doing it. Also hand tight means: To tighten with just the use of hands or fingers, without the use of tools. You say hand tight but you are using a screwdriver to tighten it.
@RCworstwater
@RCworstwater 3 жыл бұрын
If there's a better way to do it we want to know! What would you have done differently to connect the barbed fitting to poly pipe?
@vortexalerand9949
@vortexalerand9949 3 жыл бұрын
What a twat. lol
@timmyl2005
@timmyl2005 2 жыл бұрын
Someone asked a question about cooling the fitting. And I can't seem to find it but anyway. This is the reason he asked I would imagine. I know this is not new as far as the video goes but. The reason he asked about cooling the metal is it's because when you heat the polypipe you make it flexiblePliable so you're able to Insert the Barb into a pipe that it wouldn't normally just push into. He asked that because hes probably A mechanic and has installed bearing races. Same concept. Not to get too off track but to use a good example let's say a 2 stroke motor When you replace the crank assembly you have to remove remove the bottom and crank Shaft bearing, And in doing so Most companies advise Putting the bearing races not the actual bearing in the freezer overnight Because cold makes metal contract and reduce it's overall outside diameter. And they advise that you put the clean engine case case cover on a baking sheet in the oven at a 150゚ 200゚ It allows the metal to expand. Is it's called an interference fit. So that's why he asked. Not to drag on about this but, The 1st time I replaced crank bearings on a crankshaft in a 2 stroke motor but I was surprised at how Well this worked. At room temperature you canTake that bearing race sit it on that engine case and see that it does not fit. With one metal cold and the other 1 warmed up. 9 times out of 10 you can fully sest the bearing race Is with your hand. Is it literally drops in. And when it cools and warms. They are Locked in place. That's why hes asking about freezing the fitting because it will contract it all metalsExpand and contract different temperatures and different dimensions but same concept. Sorry the message was so long I was trying to make it understandable
@westleywilkes2078
@westleywilkes2078 2 жыл бұрын
I wish he wouldn’t even talk about republicans or democrats. It takes away from what he is saying. I would show this to my wife but she’ll just think it’s partisan.
@billytheweasel
@billytheweasel 3 жыл бұрын
I'm thinking of using the wife's hair dryer on rubber dishwasher supply line being supplied from a barbed supply fitting. Will this work? Should I use Rectorseal pipe thread sealant?
@fideauone3416
@fideauone3416 Жыл бұрын
I use a heat gun.
Selecting a Control Float Switch
4:36
R.C. Worst & Co., Inc.
Рет қаралды 5 М.
The ULTIMATE Poly Pipe Trick // FARMSKILLZ
12:08
Bidwell Canyon Farm
Рет қаралды 66 М.
طردت النملة من المنزل😡 ماذا فعل؟🥲
00:25
Cool Tool SHORTS Arabic
Рет қаралды 13 МЛН
WHO CAN RUN FASTER?
00:23
Zhong
Рет қаралды 43 МЛН
Barbed Fitting Troubles?...QUICK TIP GUARANTEED TO HELP!
4:12
That Fix It Guy
Рет қаралды 230 М.
How to Transition from Metal to PVC the RIGHT way
7:15
R.C. Worst & Co., Inc.
Рет қаралды 496 М.
Installing a 260 Foot Water Supply Line to the Barndominium.
28:47
From Scratch Ranch
Рет қаралды 49 М.
How to repair Polyethylene (Black Plastic) sprinkler pipe
4:53
How To Connect Barb Fitting to Water Line Using Hose Clamps
8:42
Benjamin Sahlstrom
Рет қаралды 37 М.
All About Polyethylene Poly Pipe and Fittings
13:23
Pro Irrigation Training
Рет қаралды 71 М.
طردت النملة من المنزل😡 ماذا فعل؟🥲
00:25
Cool Tool SHORTS Arabic
Рет қаралды 13 МЛН