Rebar Development Design Example | Part 6| Learn Structural Engineering

  Рет қаралды 4,433

Kestävä

Kestävä

Жыл бұрын

This structural engineering example will teach you EVERYTHING about concrete cantilever retaining wall structures and the development of concrete reinforcing! Part 6 goes over development length of concrete reinforcing per the ACI 318-14 American Institute of Concrete.
This is the best channel for structural engineering basics!
SUBSCRIBE TO KESTÄVÄ’S KZbin CHANNEL! 👇
/ @kestava_engineering
HELP SUPPORT THE CHANNEL - JOIN THE PORUKKA GANG! 👇
/ @kestava_engineering
School of PE Affiliate Link for those Wanting More Material!👇
www.schoolofpe.com/?ref=richa...
For business inquiries email: kestavallc@gmail.com
Connect with me on LinkedIn 👇
/ richard-racz-pe-620b1792
If you Want to Tip Through Brave Browser - I'm a Verified Creator! 👇
(I am not affiliated or receive compensation from Brave)
.
.
.
.
.
.
.
.
.
Disclaimers: Richard Racz, P.E. does not hold the title "structural engineer". Any claim of it in the videos or descriptions is unintentional and is superseded by the title "civil engineer" in the states of MA and OR.
The Kestävä KZbin page is intended for informational purposes only. Nothing contained in, or provided through, this KZbin page is intended to constitute advice, or to serve as a substitute for the advice of an engineering professional. Any reliance you place on such information is strictly at your own risk.
Under no circumstances will Kestävä be responsible or liable in any way for any content, including but not limited to, any errors or omissions in the content, or for any loss or damage of any kind incurred as a result of any content communicated on this KZbin page.
#civilengineering #structuralengineering #kestava

Пікірлер: 14
@ppdnd1253
@ppdnd1253 8 ай бұрын
Thank you very much. Get much knowledge.
@emadnadi5206
@emadnadi5206 6 ай бұрын
How about development length in the footing . The toe and the heel ?/
@TA3A.YAWARD
@TA3A.YAWARD 2 күн бұрын
Could you please explain to me why we need a development for conpression bars ? Like what will happen if I did not provide it Sometimes it is more than the ldh and sometimes more even than ld How is that possible ?? Why I'd we have anchored to concrete I need only like 100 or 150 But if we have a concrete column then I need at least like 400mm
@bbdest3082
@bbdest3082 5 ай бұрын
The 6 inches probably was used when #2 rebar was used, but they don’t really use #2 rebar, rather. They use wire mesh instead
@ajayasuriya77
@ajayasuriya77 Жыл бұрын
The excess reinforcement reduction factor can be utilized for both tension and compression rebar development lengths by code but is not applicable for lap splice length. However, the code does have stringent exceptions when applying this excess reinforcement factor into account.
@Qaw434
@Qaw434 Жыл бұрын
ACI 25.4.10 permits the devolpment length ld to be reduced in cases where the provided flextural reinforcement is greater than that required from analysis, except where prohibited by ACI 25.4.10.2 Also that reduction factor is not permitted in the design of members in seismic-force-resisting systems in a structure assigned to SDC D,E or F Ignoring this reduction factor will lead to a conservative value of ld
@ryanguay5460
@ryanguay5460 Жыл бұрын
The Greek symbol is psi! (Pronounced sigh)
@Kestava_Engineering
@Kestava_Engineering Жыл бұрын
Ryan coming in clutch with the Greek knowledge!
@Kestava_Engineering
@Kestava_Engineering Жыл бұрын
was the popcorn stale? let me know ASAP below
@abiodunekundayo7526
@abiodunekundayo7526 Жыл бұрын
hi bro ...... I am preparing for my PE. Please which Prep classes shold attend ? PPI2PASS ? SChool of PE ? ??
@LoquendoProxy
@LoquendoProxy Жыл бұрын
I have a question here, isn't the "horizontal" length of the hook important too(the part of the rebar that connects to the lower mat)? I've seen some documentations that recommends also Ldh as a minimum so, horizontally, the hook would also need that same Ldh that we got (15'' for this example) and it counts from the external face of the wall to the end of the footing, is it correct? or would that count as ldext per section 25.3.1?
@user-kf1rc1vz2t
@user-kf1rc1vz2t 9 ай бұрын
Did you get an answer for this question?
@bellshbondshsh8387
@bellshbondshsh8387 6 ай бұрын
@@user-kf1rc1vz2t You need a minimum of the standard hook length for that part of the bar. Many industry standards use longer than the standard hook length for this sort of situation; for example some extend the standard hook length beyond the back side of the retaining wall, but there is no code requirement for this, just industry practice based on real-world testing and performance. Far more important though is that your hook runs in the same direction as the load! Again not required by code but testing shows that the orientation of the bar has a substantial affect on the actual failure load.
@bbdest3082
@bbdest3082 5 ай бұрын
The 6 inches probably was used when #2 rebar was used, but they don’t really use #2 rebar, rather. They use wire mesh instead
아이스크림으로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 58 МЛН
Happy 4th of July 😂
00:12
Alyssa's Ways
Рет қаралды 63 МЛН
Я нашел кто меня пранкует!
00:51
Аришнев
Рет қаралды 5 МЛН
Shear Flow Design Example | College and PE Exam Studying
14:39
Concrete Shear Wall Design (ACI 318-19)
8:24
CalcBook
Рет қаралды 8 М.
Wood Shear Wall Design Example - Part 3 of 3
19:04
Kestävä
Рет қаралды 6 М.
Geotechnical Analysis of Foundations
10:06
The Engineering Hub
Рет қаралды 713 М.
아이스크림으로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 58 МЛН