Reinforcement Coupler , COUPLER का पूरा ज्ञान As Per IS 16172.

  Рет қаралды 6,559

Civil kudos

Civil kudos

Күн бұрын

Пікірлер: 39
@ReenaDevi-pt7kf
@ReenaDevi-pt7kf Ай бұрын
Good information.
@adityasipoliya7455
@adityasipoliya7455 Жыл бұрын
Very nice bharat sir, well described content hats off.
@SachinKhandelwal-u3i
@SachinKhandelwal-u3i 2 ай бұрын
Bht bdiya
@deepakyadav6523
@deepakyadav6523 Жыл бұрын
Sir very nice content. 👏👏👏👏👏. I really appreciate for your well done work. 👏👏👏💯💯💯💯
@civilkudos
@civilkudos Жыл бұрын
Thanks👍
@antimapareek3282
@antimapareek3282 Жыл бұрын
Sir really informative 👍 thank u Bharat sir
@amarjeetgupta8085
@amarjeetgupta8085 9 ай бұрын
Nice information sir❤
@chanduyadav3758
@chanduyadav3758 Жыл бұрын
Very nice sir 🙏🙏
@sushantcachu5057
@sushantcachu5057 Жыл бұрын
Kindly provide a complete information vedio on MBT cupler with costing comparison..
@shridharpatil7721
@shridharpatil7721 Жыл бұрын
Aapko mila kya sir cost comparison ?,
@rupeshkumarpajiyar8252
@rupeshkumarpajiyar8252 Жыл бұрын
Sir please make video on different tests of coupler.
@civilkudos
@civilkudos Жыл бұрын
I have Share , Please Watch.😊
@jayantaghosh3659
@jayantaghosh3659 4 ай бұрын
Namasta sir. 1st floor k upar 16mm steel bar 6 inch to 1foot tak chora jata ha to coupler use kar sakta hai? Iskaa upar ek video laye.
@nitinkashyap2931
@nitinkashyap2931 Жыл бұрын
Want to know the testing of slip test
@dhirendranegi6786
@dhirendranegi6786 Жыл бұрын
Please share the testing procedures of coupler in site as well as in lab
@civilkudos
@civilkudos Жыл бұрын
Please Visit my Reinforcement Couplers Playlist. In which I made Coupler's testing procedures.
@mayankswarup4464
@mayankswarup4464 7 ай бұрын
Sir one coupler to 2nd coupler distance kitna hona chahiye....
@AbdulRashid-vm8fj
@AbdulRashid-vm8fj Жыл бұрын
Sir column mai coupling ka position kya hai
@vbrajprasad
@vbrajprasad 3 ай бұрын
What is the market cost of this coupler with same IS Specification
@vishalchaudhary3266
@vishalchaudhary3266 Жыл бұрын
Sir coupler Ki testing.pe video bnaye
@civilkudos
@civilkudos Жыл бұрын
Mene Reinforcement Coupler par aur bhi videos banaye hai , Jiski alag se PLAYLIST hai , AP " REINFORCEMENT COUPLERS " ke PLAYLIST me jakar dekh sakte hai , yadi iske alava apko kisi aur knowledge ki jarurat ho to use pura describe kare ki actually apko kis vishay par jankari chahiye ..
@AbdulRashid-vm8fj
@AbdulRashid-vm8fj Жыл бұрын
Sir coupling zone kya hota hai
@sanjivanigayake8625
@sanjivanigayake8625 Жыл бұрын
👌👌👌👌👌👌👌👌
@hemantnegi7000
@hemantnegi7000 10 ай бұрын
sir what should be the position of couplers in column reinforcement and it is ok in column beam junction or not..?
@civilkudos
@civilkudos 10 ай бұрын
By the way, if your position of coupler comes at the junction then it is not a big deal. Well, for It's safety, the structure consultant keeps for a lap position( Zone-2) .
@muktarali4594
@muktarali4594 Жыл бұрын
Side hai kya koi threding wark ka sir
@civilkudos
@civilkudos Жыл бұрын
please visit my reinforcement coupler playlist
@AbdulRashid-vm8fj
@AbdulRashid-vm8fj Жыл бұрын
Sir position kya hota column reinforcement ka
@civilkudos
@civilkudos Жыл бұрын
Sir , Reinforcement Coupler ke 3 parts hai ap vah sabhi dekhe . I hope apko sabhi savalo ka javab milega. 👍
@sumit39pal
@sumit39pal Жыл бұрын
sir plzzz videos upload kijiyega
@civilkudos
@civilkudos Жыл бұрын
I have made Reinforcement Coupler playlist - " Reinforcement Coupler " Whatever you want to know about , you will find it there
@maheshj660
@maheshj660 Жыл бұрын
Sir I have a question, our site contractor claimed extra length for forging in column rebar , is it claimable??
@civilkudos
@civilkudos Жыл бұрын
You must have seen two methods in this video. threading and forging; Threading and forging methods have different rates. If you are getting forging method done at your construction site, then you have to give separate rate to the contractor for reinforcement forging as mentioned in the video. In forging method, you have to give the rate of steel forging. There is no need to count the steel length separately. I hope you have understood. Revert in case of any query required.
@maheshj660
@maheshj660 Жыл бұрын
@@civilkudos actually problem is that he is claiming length of rebar 30mm more at every coupler location, because during forging that 30mm is pressed and then will do forging, is this concept is right ?? Should we pay for him for additional 30mm
@civilkudos
@civilkudos Жыл бұрын
@@maheshj660 , No, you don't have to do that. You only have to pay the rate of forging. There is no need to give any extra length.
@maheshj660
@maheshj660 Жыл бұрын
​@@civilkudosthanks sir for ur valuable advise...
@maheshj660
@maheshj660 Жыл бұрын
Please make 1 video regarding bend deduction as per IS code 1d or 2d,... Thanks making such informative videos
@ashishkumar2032
@ashishkumar2032 Жыл бұрын
want coupler service pls share contact
The Best Band 😅 #toshleh #viralshort
00:11
Toshleh
Рет қаралды 22 МЛН
Гениальное изобретение из обычного стаканчика!
00:31
Лютая физика | Олимпиадная физика
Рет қаралды 4,8 МЛН
Cheerleader Transformation That Left Everyone Speechless! #shorts
00:27
Fabiosa Best Lifehacks
Рет қаралды 16 МЛН
Reinforcement lapping Zone as per IS Code 13920 in Column | Learning Civil Technology
23:58
what is GGBS  #civilkudos
13:15
Civil kudos
Рет қаралды 15 М.
How Micro Silica works | Silica Fumes | Micro Silica hydration CSH Gel formation | Elkem metallurgy
3:47
Reinforcement coupler Length l  AS PER IS CODE : 16172
5:29
Civil kudos
Рет қаралды 258
Coupler factory production process
2:34
Jerry
Рет қаралды 26 М.
Complete information about slab reinforcement | Why and When L/3, 0.1L 0.2L 0.3L || By CivilGuruji
16:01
ALL MIVAN COMPONENTS, MATERIAL, PARTS, THING,
24:57
DC SITE ENGINEER
Рет қаралды 115 М.
The Best Band 😅 #toshleh #viralshort
00:11
Toshleh
Рет қаралды 22 МЛН