Reinforcement lapping Zone as per IS Code 13920 in Column | Learning Civil Technology

  Рет қаралды 85,263

Learning Civil Technology

Learning Civil Technology

Күн бұрын

Пікірлер: 215
@LearningCivilTechnology
@LearningCivilTechnology 5 жыл бұрын
Video ko Daba ke Share karo bhailog aur apna pyar dikhau.. Taki hamare sabhi bhahiyo, hamare Juniors aur Engineers tak pahuch sake.
@manojsuthar5041
@manojsuthar5041 5 жыл бұрын
Sir plinth beam top se floor beam bottom hight hi length hoga kya
@mdshahanshahalam6262
@mdshahanshahalam6262 4 жыл бұрын
I like ur videos more than other's videos.....
@Mahijavre
@Mahijavre 3 жыл бұрын
Sir middle zone me to bending moment kam hota he na tabbi ties ki spacing ku kam rkhte he
@SurajKumar-oc3he
@SurajKumar-oc3he 2 жыл бұрын
Sir aapka video dekhne ke bad pura tarah se satisfied ho jata hu bhagwan aap ko aise aur mind ko clear rakhe 👏
@abubakarsiddik5033
@abubakarsiddik5033 3 жыл бұрын
Sir I'm form Bangladesh,You are my very good teacher.Your explanation is very good sir. Thank you so much,keep your update your video.
@mdshoaibhossain360
@mdshoaibhossain360 3 жыл бұрын
u r so good person! ❣️ Allah bls you
@krazyharsh5040
@krazyharsh5040 3 жыл бұрын
your explaination is very good
@UttamSingh-ee5oj
@UttamSingh-ee5oj Жыл бұрын
Sir I am Engineer but I can't explain as you explain. Thanks sir 🙏
@AKTV_786
@AKTV_786 2 жыл бұрын
#Beam zone required. Beautifully explained.
@VeerBuildhouseEngineering
@VeerBuildhouseEngineering 5 жыл бұрын
knowledgeable video sir 👌👍
@LearningCivilTechnology
@LearningCivilTechnology 5 жыл бұрын
Thank You Sir
@raviyadav5
@raviyadav5 2 жыл бұрын
I have downloaded your IS Code app.You have done a fab job brother.
@vinodjoshi1234
@vinodjoshi1234 Жыл бұрын
Mukesh ji I like you for good teachings
@gkengr
@gkengr 5 ай бұрын
Very well and technically explained
@anildas888
@anildas888 2 жыл бұрын
Good and informative video. Thanks!
@ziauddin7948
@ziauddin7948 2 жыл бұрын
👍👍# good lap zone in column #
@vinodkarle2630
@vinodkarle2630 5 жыл бұрын
अच्छा.व्हिडीओ.धन्यवाद.सर.
@sarthakmohapatra3738
@sarthakmohapatra3738 5 жыл бұрын
Superb video sir. #Beam and Slab lap zone
@ashwinanandh7590
@ashwinanandh7590 5 жыл бұрын
Excellent sir.. 👍👍👍🙏🙏🙏🙏
@shivamitvlogsnz2416
@shivamitvlogsnz2416 5 жыл бұрын
Also make video on staircase. As most of the people get confused while calculating treads and risers on actual site. Most important is staircase which is starting from some random floor. Which is not in continuation.
@mdahmed9336
@mdahmed9336 4 жыл бұрын
Very nice👌👌👌
@devcpwd
@devcpwd 2 жыл бұрын
Thank you for your support
@shadabhussain3695
@shadabhussain3695 3 жыл бұрын
Bro ur teaching is damn good 👍🏻 Keep it up Tnx for clearing my concept
@arunkumarkarn1995
@arunkumarkarn1995 4 жыл бұрын
NYC videos about lap zone
@phyohtetkoko929
@phyohtetkoko929 2 жыл бұрын
Thanks For Teaching Sir
@ShahabUddin-fu5yq
@ShahabUddin-fu5yq 5 жыл бұрын
Also make video on beam and slab for overlapping
@gudiyaali1357
@gudiyaali1357 2 жыл бұрын
Good job 👌
@shibnathbanerjee7821
@shibnathbanerjee7821 3 жыл бұрын
Hats of to you sir...
@rahulsingha2227
@rahulsingha2227 3 жыл бұрын
Bahat achhaa!
@RajeshKumar-my2ri
@RajeshKumar-my2ri 6 ай бұрын
Very good video
@LearningCivilTechnology
@LearningCivilTechnology 6 ай бұрын
Share and Keep Learning
@YogeshLohar93
@YogeshLohar93 Жыл бұрын
Auto level pe video banao sir....
@shashikanth3648
@shashikanth3648 2 жыл бұрын
Excellent sir
@eguru786
@eguru786 3 жыл бұрын
Beam lap also required . Thank you soo much.
@haidaralikhorejia8984
@haidaralikhorejia8984 4 жыл бұрын
Excellent sir. Please sir still ki quantity nikalna batao. Kaise still ki quantity ko nikale total slab, beam, coloum etc.
@b.m.sudhakar6595
@b.m.sudhakar6595 2 жыл бұрын
Your my Guruji
@success555
@success555 5 жыл бұрын
Very Good Follower Base. Good Luck. #Success555
@arunkumarkarn1995
@arunkumarkarn1995 4 жыл бұрын
Please make videos on RE wall highway
@-adnanKhaja
@-adnanKhaja 4 жыл бұрын
Thank a lot sir
@shankarsinghaniya617
@shankarsinghaniya617 2 жыл бұрын
Hello sir.. Yaha lap ham upar se jo joint karenge us steel me dena hai ya niche wala me.
@sunilthakur4290
@sunilthakur4290 4 ай бұрын
Sirmera columns plinth beam se11ft hai toh lapping Kiana ft par hoga
@ajaz545
@ajaz545 4 жыл бұрын
Bhut gazab sir Plz Do some Thing for compitative exam
@mahadevchinchali2843
@mahadevchinchali2843 3 жыл бұрын
Well explained
@prajayurkude9821
@prajayurkude9821 4 жыл бұрын
Its very good vidio. Please make vidio on mivan Constructions steel.
@raviprakash8640
@raviprakash8640 4 ай бұрын
Nice
@MADHAVMULTYPRINTHasmukh
@MADHAVMULTYPRINTHasmukh 4 жыл бұрын
Thank you sir
@saileshsingh1
@saileshsingh1 4 жыл бұрын
Thank you very much for the practical knowledge on Lapping Zone in column. It is increasing our knowledge and confident in real time environment in site. I have one question regarding column. What could be the solution if the length of the reinforcement from isolate foundation is not enough for Lapping which should be provided for second or next story of building ? Thank you and Regards! Shailesh Singh. Nepal
@sanjayswain9763
@sanjayswain9763 2 жыл бұрын
Sir, I want to know that.... Ki sariya ka dia Or quantity saman hona chahiye ya nanhi..... 1000sq building ka sab Callum ka
@babusjohn
@babusjohn 9 ай бұрын
Hi mukesh... i have a question. Between both the lapping zone how much should be the spacing? I mean 50% rebars to be lapped below centerline and 50%above centerline. Should there be any gap between these staggered bars?
@shahabdulhaqim8900
@shahabdulhaqim8900 4 жыл бұрын
PLEASE MAKE A VIDEO ON LEVEL OF. SLAB. ( SLAB ka level kaise check krte hai before casting)
@owaisulqamar1617
@owaisulqamar1617 4 жыл бұрын
Sir plz bta dain stagger kB provide krte hai raft me
@jackybosko1362
@jackybosko1362 4 жыл бұрын
Thanks for Ur valuable information. I want to know one information, what is the joggle length and its ratio of the lapping bar as per the code reference.
@LearningCivilTechnology
@LearningCivilTechnology 4 жыл бұрын
Will make video on it
@mohammadshoaib2073
@mohammadshoaib2073 Жыл бұрын
Column ki laping beam wale porsen me kr sakte h
@adityashekhar852
@adityashekhar852 3 жыл бұрын
Sir splice mai jo ties provide krte hai uska spacing kitna hota hai ???
@debasisghosh6697
@debasisghosh6697 4 жыл бұрын
Jab column k vertical bar k dia change hota hai tab humko kakha lapping dalna hai????? Matlab 2nd floor k bad mera steel k dia change hone wala hai..tab konsi jaiga par lap dalna hai?????
@LearningCivilTechnology
@LearningCivilTechnology 4 жыл бұрын
lap always zone B
@debasisghosh6697
@debasisghosh6697 4 жыл бұрын
I know the lap provides always zone B...But How it's possible when my dia of bar change in 2nd floor...!!!so how can i extend the bar B zone in 3rd floor...!!!
@9549549543
@9549549543 4 жыл бұрын
@@debasisghosh6697 please clear you Quotation I think for example 3rd floor par dia 20 hone wala hai aur 2nd par 25mm hai. To 25mm ka bar 3rd floor par zone B ke center tak jayega. Aap kehna chahte ho ki me steel 3rd floor par 25mm kyon du.
@sahiljharia8850
@sahiljharia8850 Жыл бұрын
In addition to that minimum clear vertical distance between lapped bars shall be 0.25 times lap length. What is this?
@mamasconstructiongroup
@mamasconstructiongroup 2 жыл бұрын
Slab beam ke Ander column r/f ka lap de sakte h kya
@engrkhalilnaz9019
@engrkhalilnaz9019 5 жыл бұрын
Very nice sir .make vedio also beam ,slab lapping
@KamalSrivastava-k4h
@KamalSrivastava-k4h 9 ай бұрын
Thank u sir
@AshokYadav-ov9uy
@AshokYadav-ov9uy 4 жыл бұрын
Jab ham clear cover ki baat karte hain to beam ya column dono cases me yah clarify Karen ki langitudinal bar ke outer face se clear cover consider Karen ya stirrups/ ties ke outer face se.Thanks
@AshuDixit-z7q
@AshuDixit-z7q Ай бұрын
Column lapping me agr dia change hota hai to kya hm maximum dia follow krenge ?
@gowrinaidu7656
@gowrinaidu7656 4 жыл бұрын
waterpoofing mixing details at buildings prepare one video sir.....
@CreativeCreative-sc8me
@CreativeCreative-sc8me Жыл бұрын
Each floor lap divide karna kya sir
@jitulkalita6579
@jitulkalita6579 3 жыл бұрын
Sir me assam se hu . mera building me column ka 6 sariya me 4 ko job join kiya tha usme laping kiya baki bij ka 2 me laping kiya nahi .kiya kharab hoga kiya .abhi me groun floor banaya he .
@ABHISHEKYADAV-oj6zt
@ABHISHEKYADAV-oj6zt Жыл бұрын
# plz tell about cutting length of steel from foundation so that we can avoid zone A for floor height 3mtr..❤
@firdous529
@firdous529 5 жыл бұрын
Sir ; Bridge pier or abutment will be same Lapping zone
@dimpalrana7183
@dimpalrana7183 4 жыл бұрын
Nice sir
@LearningCivilTechnology
@LearningCivilTechnology 4 жыл бұрын
Thank u dimpal ji
@amarkumar-hx8bk
@amarkumar-hx8bk 5 жыл бұрын
Lap joint in beam as per is13920 2016
@shaikhssr7417
@shaikhssr7417 3 жыл бұрын
16mm bar 45d kar k kat diya hun... isku over lapping dene se koi problem hoga????
@sharadbarman6491
@sharadbarman6491 3 жыл бұрын
Sir colomn ki clear length beam bottom se Lena hai ya slab bottom se ? Kyoki beam bottom , slab bottom se down hi hoga
@shivamitvlogsnz2416
@shivamitvlogsnz2416 5 жыл бұрын
Kindly make a video on accelerator and retarders, plasticizers and superplasticizers
@mkhurshid2961
@mkhurshid2961 4 жыл бұрын
What happen if the lapping given by welded ? Kindly make a vedio about why engengeers do not let welding any rebar joint in the building design ? Please let me know ! ?
@skjha1947
@skjha1947 4 жыл бұрын
Sir Column ko jab overlapping krte hai tab L/4 rule ke liye column ka total height ground se count hoga ya floor to slab? Please
@LearningCivilTechnology
@LearningCivilTechnology 4 жыл бұрын
Floor top to beam bottom
@MADHAVMULTYPRINTHasmukh
@MADHAVMULTYPRINTHasmukh 4 жыл бұрын
Very nice app
@kalindrasingh5459
@kalindrasingh5459 4 жыл бұрын
Thank you sir.....ur valuable information.sir i want to know that about bbs.
@hassanhaider9651
@hassanhaider9651 3 жыл бұрын
Sir please confirm thi, bar dia 25mm hai, uska lap zyada hai, ab lap ka kuch portion plinth beams me ja rha ha, tou kya ye possible hai ke hum uper jo columns uthayengy unko plinth se lap krkey utha len? Please confirm this sir thankyou so much
@aibansharailyngdoh8608
@aibansharailyngdoh8608 2 жыл бұрын
Bro,in lap zone do we used 45D
@vivekborse2790
@vivekborse2790 3 жыл бұрын
nice information , take a example of floor to floor ht 4 m , and give detail of lapping and lap length for footing to coloum , and above
@ravikirankadam3306
@ravikirankadam3306 2 жыл бұрын
Sir while calculating L beam depth should minus or not
@chetanrana6427
@chetanrana6427 3 жыл бұрын
G+2 ke liye column, beam or plinth Ka kya size rkhe
@amitjoshi1872
@amitjoshi1872 7 ай бұрын
Absolutely sir
@ShahabUddin-fu5yq
@ShahabUddin-fu5yq 5 жыл бұрын
Plz make a video on importance of primavera p6
@pg-ce-007ankitaroykarmakar2
@pg-ce-007ankitaroykarmakar2 4 жыл бұрын
Sir agar building ka height 12m se kam hua toh kya lap de sakte hai???
@LearningCivilTechnology
@LearningCivilTechnology 4 жыл бұрын
Ha kiu nahi.... Aur dena hi padega practically
@pg-ce-007ankitaroykarmakar2
@pg-ce-007ankitaroykarmakar2 4 жыл бұрын
@@LearningCivilTechnologythnku sir... toh sir ek 11m k building mai kitne length k baad lap denge??
@tarunpigfarm1629
@tarunpigfarm1629 3 жыл бұрын
Good sagsion
@oldephart471
@oldephart471 3 жыл бұрын
Any change in lapping zone if couplers are used?
@LearningCivilTechnology
@LearningCivilTechnology 3 жыл бұрын
No
@oldephart471
@oldephart471 2 жыл бұрын
@@LearningCivilTechnology I can't find Section 7.2.3 (in the copy of the IS code I have) to understand transverse reinforcement as mentioned in Fig 12. Please give me a link to the right version of the IS code.
@rahulgarg4335
@rahulgarg4335 5 жыл бұрын
Mukesh ji only column beam junction mai actually minimum numbers of ring set kitne provide krne chahiye as per which is code
@lakhandas
@lakhandas 3 жыл бұрын
Total station operation video banaye sir G
@sunaramsingh6881
@sunaramsingh6881 3 жыл бұрын
Kese Membership lena hai
@sgpfamilysgpfamily844
@sgpfamilysgpfamily844 3 жыл бұрын
Sir , now column height is 2.5m and stirrups spacing is 150mm. This data’s are given as per drawing ..L/6 area it has less spacing .I what spacing should use here (L/6)
@vykuvicky7573
@vykuvicky7573 4 жыл бұрын
Sir I have one doubt about feture extension of building we leave 1 height of steel for feture extension but that is not a lap zone.then what we do for that for over come that problem
@sapatesantosh0
@sapatesantosh0 4 жыл бұрын
Lapping lower dia ya higher dia interview Questions?
@hariomkushwaha2537
@hariomkushwaha2537 4 жыл бұрын
Sir jese her ek cheej ki ek limit h lekin by chance limit s gar 1 c.m. jyada ho Gaya to koi nuksaan to nai h
@mukeshmani2003
@mukeshmani2003 5 жыл бұрын
from the edge of the bottom or the top of the slab into the column, what shall be the minimum distance to provide the ties.
@vinodkumarsingh1146
@vinodkumarsingh1146 3 жыл бұрын
Yadi lap plinth beam me hai to Sahi hai ya galat ,yadi galat hai tab kya kare
@b.m.sudhakar6595
@b.m.sudhakar6595 2 жыл бұрын
Beam lap required Sir ji
@adityatiwari-lv6yb
@adityatiwari-lv6yb 4 жыл бұрын
Beam ke leye bhi video bana degeye
@LearningCivilTechnology
@LearningCivilTechnology 4 жыл бұрын
Ok
@rishavverma1611
@rishavverma1611 4 жыл бұрын
Bar me Kita mm ka minimum rod use karte hai
@skainulbari471
@skainulbari471 2 жыл бұрын
Lap na deke welding kar sakta hai kiya???
@LearningCivilTechnology
@LearningCivilTechnology 2 жыл бұрын
Gas pressure welding kar sakte hain
@jineshkumaarvklm
@jineshkumaarvklm 4 жыл бұрын
Sir it’s not available in App Store .. I could not find .. pls help
@adityaghosalkar431
@adityaghosalkar431 Жыл бұрын
Mukesh tum yaha ho..Mai Kabse dhund rha tha
@rameshsharma9636
@rameshsharma9636 2 жыл бұрын
Agar ground floor pe hi lap dena hai to bhi B zone me de Mere thekedar ne sare bar 1/2 kar diya ,mera lintal 11 ft pe hai Ab column khade ho gaye kua karoon ya to sare bar katne padega
@lovedeepsingh1398
@lovedeepsingh1398 4 жыл бұрын
# beam lap explain please sir
@shivamitvlogsnz2416
@shivamitvlogsnz2416 5 жыл бұрын
Also make a video on water proofing of terrace. What are the best materials present for it in the market.
@LearningCivilTechnology
@LearningCivilTechnology 5 жыл бұрын
already made a video on waterproofing of terrace..few days back... check my videos
@shivamitvlogsnz2416
@shivamitvlogsnz2416 5 жыл бұрын
@@LearningCivilTechnology yeah sure...Great 🙂
@javedkhan-eu2sx
@javedkhan-eu2sx 5 жыл бұрын
Thank you for this video.pls make a video on beam lap required.👍
@9549549543
@9549549543 4 жыл бұрын
Agar zone B me bars ko starting karni padi to kya karenge. How it possible with overlap?
What is Lap Length | Overlapping | Lap Splices in Beam | Column | Footing and Pile Cap
14:59
Tuna 🍣 ​⁠@patrickzeinali ​⁠@ChefRush
00:48
albert_cancook
Рет қаралды 148 МЛН
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 31 МЛН
Beam Lapping Zone as per IS 13920 - Beam Reinforcement Lap Length Formula & Lapzone
15:44
What Is The Lapping Length Of Column Reinforcement? | What Is The Lap Zone In a Column?
8:30
Civil Engineers Training Institute
Рет қаралды 43 М.
DUCTILE DESIGN AND DETAILING AS PER IS 13920
12:43
Ekeeda
Рет қаралды 10 М.
Live Class | Reinforcement Lapping Zone for Beam | Best Zone for lapping in Beam || By CivilGuruji
30:10