Hey mate we’re the nitrogen purge to braze and micron gauge for vacuum
@chocman773 жыл бұрын
Good job man, nice and tight in that condenser lol, keep the videos coming 👏👏
@maracservices3 жыл бұрын
Thanks mate. Yeah they’re so tight aye, so much stuff to burn lol.
@rdenir2 жыл бұрын
Thanks for pointing out just how stupid the HP switch is on the Daikin units,, I have replaced so many and every time I just shake my head in disbelief as to why they designed it that way where it requires a gas removal process..Yet the HP sensor switch can be removed in minutes by screwing off and screwing back on..
@maracservices2 жыл бұрын
It makes no sense to me either. So stupid!
@rdenir2 жыл бұрын
@@maracservices what’s even more unbelievable is that this has just happened to me again today on a VRV unit!!
@maracservices2 жыл бұрын
@@rdenir oh wow.. I’ve come across this twice now. They definitely fail. Once again, why it is soldered in is beyond me..
@hamdani5502 Жыл бұрын
Thanks Mr ....
@deepastephenson6422 Жыл бұрын
Nice and great way to understand and find the daily and solve it
@deepastephenson6422 Жыл бұрын
Sorry it's finding fault and solving it.
@johnhenderson4335 Жыл бұрын
How did u manage to get the last of the gas in? I though the last would go in the suction when on?... I'm trying to learn ac, just incase iv missing something..
@johnhenderson4335 Жыл бұрын
This comment was for previous video mate.. Same HP video /fault
@maracservices Жыл бұрын
So after evacuating the system, I weigh in the refrigerant. In the perfect case, there is enough pressure in the bottle to add all the gas in. If not, then I run the system and add it slowly through the suction line. I hope that helps mate.
@vladimirnik72602 жыл бұрын
Hi, soldering was without nitrogen?
@ushant29 Жыл бұрын
Hi Mitch, DAIKIN AIR WATER HIGH TEMPERATURE 16K installed in 2019 I have an error code that remains displayed: Unit 0 E3 12 160 L32 006 F5E Do you have any information regarding this recurring error code? Unit 0 concerns the outer group? Best Regards ;)
@maracservices Жыл бұрын
Sorry mate I don’t really understand what your talking about. Daikin E3 is a high pressure switch. Something is causing the system to have high head pressure OR the pressure switch is faulty.
@shamimdhaka44242 жыл бұрын
Good video very tanks
@maracservices2 жыл бұрын
Thanks mate
@santiagoyaguesegura57652 ай бұрын
Buen vídeo 👍
@sotirigouna81952 жыл бұрын
Hey bud I have the same error coming up but mine stays on for about 40mins and the top fan doesn’t kick in either
@maracservices2 жыл бұрын
It’s a high pressure switch so unfortunately the only way to diagnose this is to reset the system, and run it with some gauges on the unit. If the pressure is indeed getting to high then it could be caused by the top fan not running (if on cooling mode). However if it is coming up with this error when the pressures are fine then I’d put my money on the HPS being faulty.
@suldaancooling42073 жыл бұрын
Thanks you so much bro👍👍♥️♥️
@maracservices3 жыл бұрын
You’re welcome 🤟🏻
@richardmalewski953 Жыл бұрын
No Schrader core on switch? Crazy
@maracservices Жыл бұрын
No Schrader. You have to reclaim all the refrigerant to change it over. Crazy is correct haha.
@hanshvide893519 күн бұрын
why does not this video explain what daikin system he is talking about?
@ILMANHAFIDZ092 ай бұрын
tinggal cuci , bikin rusak ac itu namanya
@petevelasco68773 ай бұрын
W we
@bmiadmin578410 ай бұрын
The worst brand ever come across. So many faculties and problems!!!