Johann shows you how he changes a compressor in a domestic fridge
Пікірлер: 148
@fsoileau Жыл бұрын
I love a tradesman that can explain it in simple terms. I am not an HVAC Tech but I have replaced a few compressors. Find the lbs, and ozs from the specs put the bottle on a scale, and charge the system. This method of watching for line frost is so intuitive and straightforward that it blows my mind. Simply that's what we are looking for. Thank You. Worth a Subscribe.
@kojsiusoaliu67722 жыл бұрын
You cant vent r600 or r290 but cmon man just recover that r134 for god's sake
@rodgraff1782 Жыл бұрын
What is even worse he vented R12, when he blew out the lines
@strimbimmin3283 күн бұрын
Welcome to refrigeration done outside the USA/Canada lol they don’t give a damn
@beanwellnkhata80923 жыл бұрын
Thanks Johann, I always enjoy your videos.
@vusilukhele29433 жыл бұрын
Thank you. Always learning a lot from your videos. God bless you.
@ethansys27253 жыл бұрын
Informative video, as always. Learned a lot from your videos.
@vanheemskerk13 жыл бұрын
Hey Johannes. Nice video, thanx! Groetjes uit Nederland
@foreverendeavors62103 жыл бұрын
I would have liked to watched the brazing/solder procedure.
@hennieroets31892 жыл бұрын
Baie dankie vir die inligting. Ek het die stawe bestel en die sweiswerk was baie maklik. Nog maals dankie vir jou ondervinding wat jy deel.
@syedbasheer82103 жыл бұрын
Excellent job...
@mikegalgano456710 ай бұрын
WOW your allowed to vent 134a to atmosphere in your country! Wouldn't it make sense to pull refrigerant out to a tank to use later?
@ILGuy20122 жыл бұрын
Thanks for making this video. This looks a little too complicated than what I care to tackle.
@nunurbuisness5578 Жыл бұрын
I love fixing things. I recently repaired my old dry now it's good as new. It kinds sucks the equipment needed to repair a freezer though
@vlogcity1111 Жыл бұрын
A vacuum pump can be made easily with an old fridge compressor that still runs they draw hundreds of psi in vacuum
@The-Mattman3 жыл бұрын
Love your vids,very down to earth. Would it be ok to use r12 refrigerant in place of r290a ?. I have a couple of old r12 cans i could use up.
@JDNelRefrigeration3 жыл бұрын
Yes, they are very happily compatible on small domestic fridges. On the bigger ones though the capillary size might be a little bit too big.
@lonniesmith1042 жыл бұрын
And they're very illegal to.
@The-Mattman2 жыл бұрын
@@lonniesmith104 well, it’s worth it, nice cold beers now :-)
@bru3193 жыл бұрын
I have a new Embraco compressor with 3 rubber factory stub plugs. Is there a trick to pulling them out because the heads want to tear off. They are hollow and I was thinking that maybe you push a blunt wire in the there to stretch the plug and then they come out but what is your opinion? I like your tips about dealing with factory braised solder on the connections. I plan on using Harris Stay Brite 4% silver wire which melts at a much lower temperature than brazing.
@JDNelRefrigeration3 жыл бұрын
If the rubber plugs break off inside the compressor, I would, if I can get one of the 3 out, put gas pressure into the compressor through the one that you've managed to get out and with a gas welding torch heat the others up and they will just pop out.
@johnnyriser85193 жыл бұрын
Hello. I enjoy your videos! When you determined the line was frosting, and the system was overcharged, you released some gas. Since you were connected to the suction side, and the system was running, did you turn the system off briefly to allow it to build up pressure before releasing pressure, or how did you manage the release of gas? My thinking was if the release was attempted through the suction side while the system was running, you would pull in outside air. Just trying to see if there was a trick to doing it that I overlooked. Thanks., and keep the videos coming!!
@JDNelRefrigeration3 жыл бұрын
If your suction pressure runs in a vacuum you have to switch the compressor off, but with R12 the suction very seldom goes near a vacuum, so you can blow off the gas while the compressor is running.
@joeshumo94572 жыл бұрын
But it’s an r134 system that you vented to atmosphere. Certainly not R12. Unless you retrofitted the entire system. This video has far too many problems.
@elektrolyte Жыл бұрын
excellent video!! moooi MAN!!!
@chrispfeif55523 жыл бұрын
Hi Johann, lekker video. i would be able to do it myself if i had the gas and tools for soldering.. anyways. I want to ask can you, as in your company, replace my AEG fridge compressor, it ran on CCl2F2. it should be the same physics as the newer R-134 gases right? the comp is making a high pitched whistling noise. I am in CPT though...
@JDNelRefrigeration3 жыл бұрын
Yes I can replace it.
@bateeification3 жыл бұрын
Hi Johann... I have a KIC super cool fridge. The freezer does it's part in a matter of mins, but the fridge is not as efficient. It cools but stuff doesn't get as cold as it would on a normal operating fridge. Could it be a gas leak?
@JDNelRefrigeration3 жыл бұрын
From the little information you are giving me, I really can't say. I would need to test your fridge.
@antoniov41523 жыл бұрын
Just found your channel and wanna thank you for what you do sir. My refrigerator has a leak is a KitchenAid 5 door is expensive but got it for cheap I added a car freon stop leak can r134a what is your take on that?
@JDNelRefrigeration3 жыл бұрын
I've heard of the stop leak solution but I have not used it myself. I would spend some time to find the puncture and repair it.
@antoniov41523 жыл бұрын
@@JDNelRefrigeration so far the stop leak car freon has done the trick . I thank you for your response keep up the great work you do.
@s968222 жыл бұрын
Does it help to use liquid on brazed pipes to check for leaks? I recall before charging an AC minisplit you must maintain steady vacuum prior to charging. Not with a fridge?
@JDNelRefrigeration2 жыл бұрын
If you are unsure of a weld it is a good idea to use a liquid leak detecting solvent. I draw vacuum in the whole system for about 2 minutes that's all you need to remove all the air from the system before charging.
@J.T3233 жыл бұрын
Thanks,this video helped me alot...thanks for sharing your knowledge...
@godleykoena72453 жыл бұрын
We appreciate yr good job sir and yr experience
@johnnieveight49252 жыл бұрын
i wish we had guys like you in the UK, seams like fridge engineers over here just say the fridge is old and to just throw it away!!
@166Roberto2 жыл бұрын
I don't wish to see these guys in the UK. First thing we learned was not to release the harmful refrigerant into the atmosphere
@Beelzebub73 Жыл бұрын
@@166Roberto r134a is not a ozone depleting gas so you just told us you learned nothing without actually saying it
@jackmorgan70911 ай бұрын
@@Beelzebub73 BUT it is a very potent grenhouse gas which is not great.
@MrJrryhy4603 жыл бұрын
Can you use a regular propane soldiering torch? Or do I have to get a MAP gas torch? Can I use regular soldering fill? I want to thank you for sharing this DIY repair to help me save money during these trying times.
@JDNelRefrigeration3 жыл бұрын
Yes you can use a propane torch, rather not use soldering, get the proper rods
@MrJrryhy4603 жыл бұрын
@@JDNelRefrigeration I cannot say enough thanks for sharing this to everyone. This helps.
@michaelbaltay79162 жыл бұрын
Hi, Thx. helpful video. Question: I am rebuilding sub zero refrigerator running R134a. 1.Other than adapting connections, is there any reason why cannot use automotive R134a in new installed residential Embraco compressor and new evaporator? 2. Do you need any oil additives for new residential AC system? Thx.
@JDNelRefrigeration2 жыл бұрын
134a whether automotive or domestic or commercial is the same thing. As far as my knowledge stretches 134a is not used in household air conditioning. They use R22 or 407c or 410
@tbone63542 ай бұрын
If you add purified water to the compressor before regassing then there is no need to vacuum
@mdsadamahmed12083 жыл бұрын
Thanks sir Refrigerator chamber making system vedio uploaded
@Talib8273 жыл бұрын
Hi is it necessary to do flushing when replacing a compressor if gas was coming out? And if you did do flushing what Is your suitable way of doing it.
@JDNelRefrigeration3 жыл бұрын
If the system is clean I do not flush it. If the system is dirty there is a few different types of flushing agent available for different applications.
@boashna3 жыл бұрын
anybody can answer this my system use ptc system. I am not sure if I use the correct ptc but I hear and see the overload activited and working. is that mean the ptc is correct and motor stuck .. what happens if ptc fits but wrong ..
@JDNelRefrigeration3 жыл бұрын
You have to run the compressor through an amp meter and see whether the compressor draws the correct current according to the manufacturers specifications.
@bobbofly4 ай бұрын
I'm assuming the replacement compressor utilizes ester oil, since you're mixing r12 & 134a? Either that or you meant you're refilling with *r12a* which is basically propane, sans the odor additive?
@JDNelRefrigeration4 ай бұрын
The oil on small domestic fridges does not cause a problem
@m.n.3490 Жыл бұрын
I would have like to see you do the welding.
@dale36453 жыл бұрын
Very helpful video but I’m not sure I understood a comment you made to someone. I will use map gas torch. I wasn’t understanding WHAT solder or flux to use from your video or comments. What would I ask for or look for in the store?
@JDNelRefrigeration3 жыл бұрын
I use acetylene welding which creates a hotter flame than map gas but there is no problem with using map gas. We get lots of different grades of silver solder in South Africa with different types of silver content. The one with the highest silver content is called mattibraze 34. The flux powder I use is the same that is used on precious metals - for silver brazing alloys at temperatures up to 800 degrees celcius. We used Easy-flo flux powder.
@dale36452 жыл бұрын
Thanks, I’m doing project today!!!!!!!!
@johnnyriser85192 жыл бұрын
Hello. What type silicone did you use to glue the defrost tray back on with? Thanks.
@JDNelRefrigeration2 жыл бұрын
I buy a white multipurpose rubber silicone.
@johnnyriser85192 жыл бұрын
Thanks. I will try to find some.
@douglas747wct3 жыл бұрын
Eish...lekker! Baie dankie.
@NickAnderson-rc4gt Жыл бұрын
I wish to know how may I switch a 220vac compressor into 12vac. How to rewind it, what wire gauge to use, etc. I wand to operate my refreg on battery without using an inverter. Is it possible?
@JDNelRefrigeration Жыл бұрын
You can buy a 12volt compressor I do not think you can rewind a 220v compressor into a successful 12volt compressor.
@hemtet55002 жыл бұрын
Does a fridge freezer have the same set up? thanks
@JDNelRefrigeration2 жыл бұрын
They are all similar.
@qrocks013 жыл бұрын
hi.. how do you calculate what sise compressor to install if there is no specs on it?
@JDNelRefrigeration3 жыл бұрын
All compressors are marked with specifications, either with codes that you can look up what displacement, BTU & power consumption or some mark the power consumption on the compressor itself. If there is no markings you can use an educated guess according to the size of your fridge.
@1caniac3273 жыл бұрын
you should've shown the welding part
@beanomino Жыл бұрын
Morning please can you tell me what type of paint can i use to paint inside my fridge
@JDNelRefrigeration Жыл бұрын
Rust-oleum.
@katojeremiah2 жыл бұрын
Should the drier be replaced whenever a compressor is being replaced
@JDNelRefrigeration2 жыл бұрын
Yes because it is a filter & no matter how clean or hygienic you think the job is done, there is always a little bit of impurities and secondly a drier is a very inexpensive part.
@rmoran99998 ай бұрын
When you pinched it and then sold it the end of the line. Wouldn't air want to blow back out of that joint?
@JDNelRefrigeration8 ай бұрын
No.
@rmoran99998 ай бұрын
Ty
@twincam8252 жыл бұрын
Do you purge with nitrogen when soldier .
@JDNelRefrigeration2 жыл бұрын
No I use the same type of refrigerant that the system will run on.
@nchomey2 жыл бұрын
Thanks for the video. Why do you aim for 10psi? I've seen numbers from 0-4in vacuum all the way up to 22psi. Is this a fridge only or a fridge/freezer? Thanks!
@JDNelRefrigeration2 жыл бұрын
Different gasses work on different pressures. In this video the fridge was charged with R12. If I had used a different gas my initial charge would have been a different pressure.
@nchomey2 жыл бұрын
@@JDNelRefrigeration understood. Thanks! Any suggestions for r134a in a fridge/freezer? Pressure/temp tables lead me to believe that around 0psi is ideal for this situation.
@JDNelRefrigeration2 жыл бұрын
@@nchomey 0 psi will be achieved at a very cold evaporation temperature, but starting off with a warm fridge, pressure should also be around 10psi
@nchomey2 жыл бұрын
@@JDNelRefrigeration thanks! Yes, I mean aiming for 0 psi when the fridge/freezer is fully cold. I have about 3psi right now when cold/running and it's about 13 when the compressor is off. Seems like it could be a bit lower - there is frost on the suction line, almost to the compressor.
@JDNelRefrigeration2 жыл бұрын
@@nchomey If you blow a little bit of gas off, the frost on the suction line should melt.
@lobdsk6 ай бұрын
Can you any compressor that fits it a refrigerator?
@JDNelRefrigeration6 ай бұрын
Yes, you can fit any compatible compressor
@seanborman32612 жыл бұрын
Johann, thanks for posting these videos. I was very surprised to see you vent R-134a into the atmosphere since it's a potent greenhouse gas. Just 1kg of R-134a has the same warming effect as 1.43 metric *tons* of CO2 (R-134a GWP is 1430). Here in the US there's an effort underway to phase out high GWP refrigerants like R-134a. R-12 is even worse since it's a CFC that breaks down the ozone layer as well as being an extremely powerful greenhouse gas. R-12 was banned under the Montreal Protocol that was pun in place after we realized that CFCs were responsible for ozone depletion. R-12 has a GWP of 10900, so venting 1 kg of R-12 is equivalent to releasing almost 11 tons of CO2! To put that into perspective, that's the amount of CO2 released from burning a little over 4000 liters of diesel in a vehicle engine. Crazy, huh? Though it *seems* harmless to release the charge from a fridge, I hope my info shows you that's not the case. Please will you consider capturing the gas and having it destroyed properly? I know SA isn't subject to the environmental laws that apply in many other countries, but the atmosphere and climate doesn't really care where the release occurs. We're all in this together. Met groot respek en dankie.
@AirmanJH2 жыл бұрын
How do you propose capturing the gas when there is no service port?
@hallcrash2 жыл бұрын
@@AirmanJH tap it with a line piercing saddle valve.
@hallcrash2 жыл бұрын
Its cost effective to capture the gas. It can be dried and reused. I'm suprised the company who supplies the gas you use doesn't pay you for recovered gas.
@nkujajunior83732 жыл бұрын
Sir please solve these problem how do you test that you did not block the filter drier after welding it in and how do you test a working compressor that it will be able to run with gas
@JDNelRefrigeration2 жыл бұрын
If the gas circulates it means there is no blockage. A quick test - put power on the compressor let it run for a few seconds while holding your finger on the high side tube to feel if it builds up pressure.
@tbone63542 ай бұрын
A good idea is to fill the compressor with water before regassing. Then it will run cooler
@JDNelRefrigeration2 ай бұрын
Less than one drop of water in the system will freeze and cause a blockage.
@tomsawer869610 ай бұрын
WOW - you do understand that R134A is a danger to ozone layer and is illegal to release like that?
@MJ-uz4zw2 жыл бұрын
Just out of curiosity why didn’t you just cut the suction and high pressure side lines rather than un soldering them off. It looked like you had enough line to complete the job. Thanks for the informative video
@JDNelRefrigeration2 жыл бұрын
I do sometimes cut the pipes off, but for this demonstration video I showed that you can do the joints without cutting the pipes off.
@MJ-uz4zw2 жыл бұрын
@@JDNelRefrigeration awesome I’m getting ready to do my compressor swap later today. Also when pulling a vacuum does it remove any moisture from the system?
@JDNelRefrigeration2 жыл бұрын
@@MJ-uz4zw Yes it does but rather than removing moisture try and prevent moisture from entering the system while changing the compressor
@enduringpromise3 жыл бұрын
I see you are in South Africa. In the USA we must evacuate R134A into a recovery tank and return it to a recovery center.
@chrispfeif55523 жыл бұрын
yea i was wondering about that too. i guess the work space there is well ventilated. i checked wiki ,it seems R134a has an insignificant ozone depletion potential, but i agree it should be saved/'recycled'.
@rodgraff1782 Жыл бұрын
@@chrispfeif5552 Yea, but he also purged and vented R12, which one of the first refrigerants that were banned. It is much greater as far as ozone depletion, along with R11, R22, and R500. South Africa agreed to follow the Montreal Protocol on January 15, 1990, so he is required to recover the refrigerant.
@TheHolyFlapjack2 жыл бұрын
A bottle of r-12 that big would go for a pretty penny over here in the US…..
@fahimzaywari53183 жыл бұрын
in which country you are located.
@JDNelRefrigeration3 жыл бұрын
South Africa
@beanomino Жыл бұрын
Please can you explain the difference between a dual compressor fridge and a single compressor
@JDNelRefrigeration Жыл бұрын
On a dual compressor fridge the one compressor will work the fridge side & the other compressor will work the freezer side. On a single compressor. One compressor works both the fridge and freezer.
@beanomino Жыл бұрын
@@JDNelRefrigeration thank you
@almighymole21424 ай бұрын
Use a scale for correct charge
@stevejrsalazar301110 ай бұрын
Why didn't you capture the freon???
@alexdavis7872 Жыл бұрын
Shouldn’t you have recovered the refrigerant in the system?
@JDNelRefrigeration Жыл бұрын
On a small domestic I do not recover the gas but on larger refrigeration equipment I do recover.
@orutraorutra64522 жыл бұрын
Sorry, but no mater what you should use a recovery refrigiration equipment and not just vent it to the air to increase the ODP and GWP. If you past and have your EPA license you know that you can be fined for this actions.
@agamparihar40336 ай бұрын
Where. Is. Your. Shop. Address.
@JDNelRefrigeration6 ай бұрын
we are located at 37 5th street, Linden, Johannesburg
@joeduca60712 жыл бұрын
you have to run nitrogen inside the tube when brazing or carbon will build up inside them and it will destroy the compressor soon
@JDNelRefrigeration2 жыл бұрын
I you notice, I did flush the system with the type of refrigerant that I use for the charge before fitting the pencil dryer
@rodgraff1782 Жыл бұрын
@@JDNelRefrigeration purging with R12 is not going to remove the scale.
@Gaz8883 жыл бұрын
Don't you Guys have laws about discharging gas into the atmosphere we do! That stuff puts massive holes in the izone
@tubatits2 жыл бұрын
We do in Canada, also for who can purchase. My experience has the vast majority of retailers have no idea about asking for the certification, before the purchase. I regret taking the course because the government is doing nothing about enforcement.
@rodgraff1782 Жыл бұрын
@@tubatits His country agreed to the Montreal Protocol on January 15, 1990, which banned the practice of discharging Ozone Depleting refrigerants.
@XX-mi7kq3 жыл бұрын
EPA watching this 👁️👁️
@coffeeseven3 жыл бұрын
Definitely not a U.S. compressor change. Let's just let a the gas out LOL
@TheRayMaynard2 жыл бұрын
EPA would love this. obviously not in USA.
@chemicalcowpoke3072 жыл бұрын
EPA has no say in RSA...
@rodgraff1782 Жыл бұрын
@@chemicalcowpoke307 Maybee, but South Africa agreed to follow the Montreal Protocol on January 15, 1990. It requires him to recover the refrigerant.
@drpoundsign2 жыл бұрын
I'm a pretty well off late middlle-aged guy. But, I'm PISSED about my twenty year old inherited GE refrigerator (probably) dying. )-; I lost a leg of power back in July, and the surge probably doomed the compressor. There is a humming noise, the light inside (along with lights in my house) dim, and it clunks towards the end of it's -all too frequent now-cycle. The surges FROM the fridge have probably taken out my HVAC transformer for the second time. This repair looks complicated. I cleaned the coils in back and slots in the cardboard today. These puppies used to last forever in the OLD days.
@JDNelRefrigeration2 жыл бұрын
I don't know where you are but you would need a technician to examine it and diagnose the fault.
@drpoundsign2 жыл бұрын
@@JDNelRefrigeration I did an experiment last night. I unplugged the fridge for ten minutes, and STILL had flickering lights. What's Really Weird is that when I turn on an overhead light near the fridge, it sounds almost normal. But, when it's OFF, it makes that "dying" sound. I am DEF calling the electrician today
@ashrafkarjiker6888 Жыл бұрын
Why don’t you install a service valve on the compressor
@JDNelRefrigeration Жыл бұрын
The type of service valves we get in South Africa has a plastic seal inside and from the heat of the compressor I find that after a couple of years it can develop a leak.
@rodgraff1782 Жыл бұрын
It’s best best practice everywhere to remove the access valve, pinch off and braze the end of the process tube, just like he did in the video.
@rodgraff1782 Жыл бұрын
Why did you not recover the refrigerant? South Africa agreed to follow the Montreal Protocol on January 15, 1990, which makes it illegal to vent ozone depleting gasses, including R134A and R12 refrigerants. Hope no one with authority to enforce it sees your video. just cut the lines. Just running your vacuum pump for two minutes does not prove you had a good vacuum. You did remove your service valve and resealed the process tube, which is very good.
@JDNelRefrigeration Жыл бұрын
On big refrigeration plants I do recover the gas but not on the small domestics.
@shawnrasch38272 жыл бұрын
cutters are not recovery equipment
@user-kl7gu2vb5h3 ай бұрын
Hy
@bluecollardownunder36162 жыл бұрын
Oh my goodness! Really? You didn’t recovered the refrigerant? 😳 stop making video tutorial dude! 🤦
@networkingdude5 ай бұрын
You don't vent gas to the atmosphere... You don't put random amounts of gas in, you weight it to the correct amount... There's lots of good info here but please don't take these shortcuts.
@edsecce56853 жыл бұрын
I guess that gas is harmless to humans and the environment
@foreverendeavors62103 жыл бұрын
134a is harmless.
@edsecce56853 жыл бұрын
@@foreverendeavors6210 thanks
@davemcgaffney94012 жыл бұрын
I'm was surprised seeing the R134a being vented to the atmosphere... The use of obsolete R12 and no real measurement of the quantity of refrigerant... Here in the USA they would be all over you with large fines over the depletion of the ozone layer... Must be nice not having government all over you...
@foreverendeavors62102 жыл бұрын
I previously put that it is harmless, that is a pretty loose statement, I wouldn't go scuba diving with it lol, all joking aside it should properly be recovered.
@kojsiusoaliu67722 жыл бұрын
Not for the environment..
@maureenv83122 жыл бұрын
Very bad camera
@Riffuchs11 ай бұрын
To be frank, I stopped watching the video when I saw the refrigerant being wented to atmosphere. Not like there's rules about how to handle refrigerants environment friendly. And not likes those rules are there for a reason. But hey... it's YT, every non-professional can show off and act like he's doing good work. Some click and some more cents from from YT make it worth to vent refrigerants doing a ton of damage to the climate to the atmosphere, yes? God grief.