Rerouting Wires: Upgrading to a 200A Breaker Box, Part 3

  Рет қаралды 2,919

Reid the Manual

Reid the Manual

Күн бұрын

Пікірлер
@christianz8020
@christianz8020 2 күн бұрын
I hope that is not in USA. I'm stunned he put all the wires back in the same way
@reidthemanual
@reidthemanual 2 күн бұрын
Haha. I’m definitely in the USA. How would have done it?
@RonRichards-v5f
@RonRichards-v5f Күн бұрын
@@reidthemanual It's a good, clean job
@Kamala-aint-Black
@Kamala-aint-Black Күн бұрын
​@@reidthemanualNo romex connectors?
@mkkkay4789
@mkkkay4789 2 күн бұрын
That will be 20,000 usd
@reidthemanual
@reidthemanual 2 күн бұрын
Hiring work done always feels too expensive, but I was thankful for the help.
@CybekCusal
@CybekCusal 22 сағат бұрын
This is trash. So many code violations where do i start. Need a disconnect outside, need to separate your grounds and neutrals, need AFCI breakers. This has been code for many years. Don't give me that "my local AHJ doesn't require me to follow code" nonsense. It's the "national electrical code* it's there for a reason. It would have been smart to make these upgrades as part of the project instead of using 1990 materials and technique. Hack job.
@reidthemanual
@reidthemanual 21 сағат бұрын
To be clear, this setup is perfectly safe (grounds and neutrals bonded properly) and fine for existing construction. MWBCs are just something to watch for in the field. I respect your views and am actually “one of those people” who wants to do everything by the book and spare no expense to do so. That was my plan. Without recounting the months-long saga that was going on with this project, let’s just say that sometimes we have to humbly check our perfectionism at the door. It’s a long story…
@CybekCusal
@CybekCusal 16 сағат бұрын
@reidthemanual I have an electrical license, you don't so whatever you think and say is irrelevant.
@reidthemanual
@reidthemanual 10 сағат бұрын
@ I respect your opinion and am glad you care about the code.
@lostonlongisland6845
@lostonlongisland6845 3 сағат бұрын
@@reidthemanual dudes right, you do need a disconnect outdoor, the way you bought the wires in the top of the panel is wrong.plus no ground rods or water bond , but you dont need ark fault breakers unless you move the panel more than 5 feet, wich you didnt. but county aproved so job well done! ps i like the future junction box 👍
@reidthemanual
@reidthemanual 2 сағат бұрын
@lostonlongisland6845 Thanks. The county and utility were steering the ship here, so I went along with what they requested. Outdoor disconnects are not yet “code” in my county. The box is grounded though via a ground rod under the meter socket (ground wire is in the small conduit leaving the meter socket).
Japan’s (Surprisingly Safe) Outlets, Explained
12:32
Andrew Lam
Рет қаралды 388 М.
THIS changes DIY Audio...
19:46
Zac Builds
Рет қаралды 340 М.
Quilt Challenge, No Skills, Just Luck#Funnyfamily #Partygames #Funny
00:32
Family Games Media
Рет қаралды 55 МЛН
So Cute 🥰 who is better?
00:15
dednahype
Рет қаралды 19 МЛН
She made herself an ear of corn from his marmalade candies🌽🌽🌽
00:38
Valja & Maxim Family
Рет қаралды 18 МЛН
To Brawl AND BEYOND!
00:51
Brawl Stars
Рет қаралды 17 МЛН
HOW GOOD WAS PELÉ?
18:28
Gustavo Marques
Рет қаралды 3,5 МЛН
Turbo Fan Dusters are getting out of hand
14:08
Torque Test Channel
Рет қаралды 1,6 МЛН
I never understood why you can't go faster than light - until now!
16:40
FloatHeadPhysics
Рет қаралды 4,8 МЛН
What is a Lost Neutral? Lost Neutrals demonstrated
12:21
Morgan Inspection Services
Рет қаралды 114 М.
90% of Toilets Are Installed Wrong (Here’s the Right Way)
16:04
Home RenoVision DIY
Рет қаралды 2,2 МЛН
you are clamping too long
10:03
WoodcraftBySuman
Рет қаралды 398 М.
A breaker disguised as a meter
19:16
Bobsdecline - Lineman blogger
Рет қаралды 1,2 МЛН
Quilt Challenge, No Skills, Just Luck#Funnyfamily #Partygames #Funny
00:32
Family Games Media
Рет қаралды 55 МЛН