Earth electrode testing the proper way

  Рет қаралды 18,514

Residual Electrical

Residual Electrical

Күн бұрын

Пікірлер: 50
@TheHomeent
@TheHomeent Жыл бұрын
Once again you nailed it. Always great videos. Full of information and the job done properly, no shortcuts.
@bramcoteelectrical1088
@bramcoteelectrical1088 Жыл бұрын
good to see as not many have done the 3 lead test or understand how to carry out this testing good video thanks
@walseee
@walseee Жыл бұрын
Where you been, we’ve missed you 😢
@Jake_Baker_Electrician1997
@Jake_Baker_Electrician1997 Жыл бұрын
Not a test I have had to undertake often, so this video will be a massive help to refresh the memory in future! You’re probably the best KZbin Spark for informative content that looks awesome 👌 watched all your content and I’ve adopted a lot of the things you do into my own skill set which has helped me massively as an apprentice!
@fredflintstone1
@fredflintstone1 Жыл бұрын
years ago I used a wheatstone bridge meter for testing earth rods in hospitals
@johnward5006
@johnward5006 Жыл бұрын
Top man! You nailed it and that's a plumber commenting!
@DarkShadowedOne
@DarkShadowedOne Жыл бұрын
Only just had to use this sort of tester at work this week for doing lightning protection testing. Lucky you have a nice open area to drive your test stakes in for your video
@fje1948
@fje1948 Жыл бұрын
Excellent video - you do thing’s properly! Many thanks Mike.
@patterdalezipsuzilil
@patterdalezipsuzilil 4 ай бұрын
I used to fit mats 4ft square copper dig a big hole all rods and plates only work if soil is damp with plates we put sink waste pipes into ground for watering in dry weather
@Engineer-Samibress
@Engineer-Samibress Жыл бұрын
Thanks for your time
@corymac
@corymac Жыл бұрын
Great job! 👍🏼
@angelofranklin1
@angelofranklin1 Ай бұрын
Well explained and well done...
@rattlehead85
@rattlehead85 Жыл бұрын
Fantastic video mate. Good reference material to go back on as this test is not one of the common ones and not many sparks could tell you how to do it. Calculations towards the end got a bit complex with the percentage deviation but how you explained it was great. Well done fella. Enjoy your content. 👍🏻👍🏻👍🏻
@sergiofernandez3725
@sergiofernandez3725 Жыл бұрын
Great explanation Mike
@avfczoff
@avfczoff 3 ай бұрын
Really helpful video & well explained 👍🏻
@paulstimpson8977
@paulstimpson8977 8 ай бұрын
I went with a cheaper tester as testing can be done with as you say by 3 methods, my luck get called to a TT install with a fault no power (Fuse pulled) and what looks like a disconnected Earth Rod! Didn't do the job in the end because no one knew who pulled the fuse or why and other issues! But I would have been in a pickle not being able to prove the TT earth was sound prior to the Supplier (DNO had no contact and stated that without knowing why the fuse was pulled they would not reinstate) coming out and who knows when they would turn up! Would probably need to be there when they came.
@markrainford1219
@markrainford1219 3 ай бұрын
What a palaver!
@e5Group
@e5Group Жыл бұрын
coming along nicely
@lowrybrock8272
@lowrybrock8272 Жыл бұрын
That’s really interesting stuff. And go ahead and admit it, those were your toys weren’t they? Good to see you back! Be safe out there!
@iosebbegiashvili8145
@iosebbegiashvili8145 11 ай бұрын
previously with efli test you have almost similar readings ,i wonder ,is it worthy to do potential fall test as well?
@maximuspareo
@maximuspareo Жыл бұрын
It is ok 16 ohm ??? In my country we need 4 ohm for normal and 1 ohm for + lighting protection .
@adriatikkrasniqi1453
@adriatikkrasniqi1453 Жыл бұрын
How did you do calculations is 2.2 percentage. To ne work out 3.8 percentage..,
@abdulseaforth6930
@abdulseaforth6930 6 ай бұрын
@@adriatikkrasniqi145316.2/16.56≈0.98 ie 2% difference
@chrismason3341
@chrismason3341 9 ай бұрын
Dno or supplier still not been out to reseal?
@tincanpete
@tincanpete Жыл бұрын
interesting and helpful video... thanks!!
@alantowler9430
@alantowler9430 Жыл бұрын
excellent video.
@vioreltanasa988
@vioreltanasa988 Жыл бұрын
What are you doing when you measure to a industrial place and you cannot disconnect earth because are a engine in process
@martijn7924
@martijn7924 9 ай бұрын
Look up stakeless and selective earth testing. If money is not an issue, see earth clamp meters as well.
@SpikesMavic
@SpikesMavic 9 ай бұрын
But if the test Spikes are into dry ground, what will that measure ?
@abdulseaforth6930
@abdulseaforth6930 6 ай бұрын
Dry ground - worst case scenario
@flint1982769
@flint1982769 Жыл бұрын
Great video!!
@chas3997
@chas3997 4 ай бұрын
look st the reason behind the test its to find if your intentional earthing rod position is placed at higher resitance postion than other possible ground at a much lower resistance. In real life we place them where they wont be disturbed and have a loop value below a 100 ohms 😀. ( the condu disk project you did i would see a calculated average being of more value than this over kill method for a single ground stake 🧐)
@residualelectrical
@residualelectrical 4 ай бұрын
Mate it’s literally the preferred test method in guidance note for testing earth electrode systems, it’s also great for determining rod location, same principals. The purpose of the video was to educate others on how to conduct the test, if anything the simpler the installation, the easier to get the knowledge across.
@chas3997
@chas3997 4 ай бұрын
@@residualelectrical Yes all good but i think the purpose of this test is to find the best location for the ground rod as far as impedence but there other considerations as well such as location it wont be distubred or provide a hazzard.
@chas3997
@chas3997 4 ай бұрын
personally aslongs its below 100 ohms and not distubed im happy with that !
@NabeelAhmad-gp5ps
@NabeelAhmad-gp5ps 7 ай бұрын
I haven't five years experience in this field...please guide me and help me i want work with you
@electricalservicesmaroc
@electricalservicesmaroc Жыл бұрын
Hello man ❤❤❤🎉🎉🎉
@Riley_Jarvis_the_sparky
@Riley_Jarvis_the_sparky Жыл бұрын
Lovely video bud keep it up 👍
@residualelectrical
@residualelectrical Жыл бұрын
Thanks, will do!
@vioreltanasa988
@vioreltanasa988 Жыл бұрын
Rezistence should be under 4 ohms for civil and industrial ,and under 2 ohms for farming 😢
@adriatikkrasniqi1453
@adriatikkrasniqi1453 Жыл бұрын
I done the calculations 3.8 percentage not 2.2 percentage…
@fje1948
@fje1948 Жыл бұрын
@adriatikkrasniqi1453 Hi. Can you please provide an analysis of your calculations - Thank you. I make it: max deviation from average 16.56 - 16.20 = 0.36 then (100/16.56) x 0.36 = 2.17% which is close to Mike’s result!
@adriatikkrasniqi1453
@adriatikkrasniqi1453 Жыл бұрын
@@fje1948 you have to do the highest minus average taken from 3 reading then divide by the highest + - 5% but not more then that…
@fje1948
@fje1948 Жыл бұрын
⁠@@adriatikkrasniqi1453 Thank you for your swift reply. Using Mikes readings: Highest 16.84 - Average 16.56 ---------- 0.28 Further using your wording: ‘Then divide by the highest’ 0.28/16.84=0.01662708 ??????????? Your detailed calculations using Mikes readings would be appreciated - Many Thanks.
@adriatikkrasniqi1453
@adriatikkrasniqi1453 Жыл бұрын
@@fje1948 than times by 100 %
@adriatikkrasniqi1453
@adriatikkrasniqi1453 Жыл бұрын
@@fje1948 I the end of the day is good to contribute with this calculation for us as learners maybe I am wrong Mike calculation I could be right I don’t but he to explain the calculation.
@vioreltanasa988
@vioreltanasa988 Жыл бұрын
You have only 1 electrode must be 3 in star connected
@vioreltanasa988
@vioreltanasa988 Жыл бұрын
I am not satisfied with this
@vioreltanasa988
@vioreltanasa988 Жыл бұрын
Electrods sh
Running a 12k lb harbor freight winch with LiFePO4 batteries @ 24v
31:36
Devin Gleason Lambert
Рет қаралды 36
Mom Hack for Cooking Solo with a Little One! 🍳👶
00:15
5-Minute Crafts HOUSE
Рет қаралды 23 МЛН
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН
Installing an earth Rod - New TT Supply
30:36
Residual Electrical
Рет қаралды 58 М.
Maximum Earth fault loop impedance
27:21
JPElectric
Рет қаралды 14 М.
Testing a ConduDisc earth electrode system at a railway station
28:02
Residual Electrical
Рет қаралды 15 М.
Quitting my job and going out on my own | REC01
26:06
Residual Electrical
Рет қаралды 28 М.
HOW TO PREFORM EARTH RESISTANCE TEST
14:36
rictor rictor
Рет қаралды 273 М.
Loop Impedance
15:56
John Ward (jwflame)
Рет қаралды 294 М.
Terminating a 630A 3 phase supply
27:39
Residual Electrical
Рет қаралды 76 М.
Earth Fault Loop Impedance Test & Prospective Fault Current Test
16:50
City & Guilds Electrical
Рет қаралды 699 М.
Halloween is coming
0:12
Younes Zarou
Рет қаралды 3,4 МЛН
ПОСТАРЕЛА ЗА 1 ДЕНЬ НА 20 ЛЕТ - МУЖСКОЕ ЖЕНСКОЕ
55:44
ПРИЯТНЫЙ ИЛЬДАР
Рет қаралды 677 М.
ЛАЙФХАК НА КУХНЕ ! 🧐🤦🏻‍♂️ #shorts #лайфхак
0:15
Крус Костилио
Рет қаралды 109 М.
Самые простые строительные леса
0:54
Канал ИДЕЙ
Рет қаралды 1 МЛН