Response Spectrum Analysis as per IS1893 in Staad Pro. V8i (Dynamic Analysis)

  Рет қаралды 120,616

OnlineCivilDigital

OnlineCivilDigital

Күн бұрын

Пікірлер: 97
@inamgay
@inamgay 11 жыл бұрын
Amazing Walk through, i have been searching for the RS analysis on the web for months without any progress, and boom civildigital to the rescue.. !!
@satydevnegi5454
@satydevnegi5454 10 жыл бұрын
Great Video, Thanks Civil Digital for uploading
@MrSyedfaheem
@MrSyedfaheem 5 жыл бұрын
The way of teaching is perfect. Great work Sir...!!!
@rohitbabje4041
@rohitbabje4041 7 жыл бұрын
Very nicely explained with references. Very useful.
@mdzeeshanali
@mdzeeshanali 11 жыл бұрын
THIS IS VERY GOOD INITIATIVE BY YOU...A VERY-VERY THANKS TO YOU
@satishjethwani8318
@satishjethwani8318 2 жыл бұрын
GREAT ... VERY NICE EXPLANATION .... VERY USEFUL
@ramesh_yezdi
@ramesh_yezdi 4 жыл бұрын
The explanation is at the best... Thank you so much for making such a useful one.
@soniyakhatri27
@soniyakhatri27 7 жыл бұрын
Hello sir, really helpful video. Easy to understand. Great work. Can you also provide video for how to design a structure with shear wall and its dynamic analysis?
@edenty1716
@edenty1716 3 жыл бұрын
instaBlaster
@RamachandranRavichandran
@RamachandranRavichandran 3 жыл бұрын
Well Presented. Crystal Clear!
@KuldeepKumar-po8tt
@KuldeepKumar-po8tt 5 жыл бұрын
thanks a lot, really helpful video and Easy to understand dynamic analysis, keep it up. it will be more use full if add geometry of model with dimensions .
@yagneshjoshi11
@yagneshjoshi11 10 жыл бұрын
Thank you so much for your remarkable efforts...
@onlyforstructuralengineers7443
@onlyforstructuralengineers7443 5 жыл бұрын
Hello Sir! very worth watching and thank you for sharing the precious knowledge. One doubt is that In Static analysis while defining the seismic definition, EQ load cases must be put first ,otherwise error may pop up. But in Response spectrum analysis you have created as usual DL and LL case first and then response spectrum load case. Here why there is no error? Please explain this Sir.
@sarvangpandya8576
@sarvangpandya8576 3 жыл бұрын
Really Easy to understand.
@HITESHKUMAR-bn5eq
@HITESHKUMAR-bn5eq 11 жыл бұрын
got a help from this video...keep it up guys...
@hinaajannabum3871
@hinaajannabum3871 5 жыл бұрын
Extremely good video. Please upload video on model generation, response spectrum analysis for building resting on sloping ground say 40% slope.
@ak_1293
@ak_1293 7 жыл бұрын
nice video!! u v taken vry great effort... Really very helpful vid..... thanks a lot....!
@dilbagstar
@dilbagstar 5 жыл бұрын
Sir, I have one question in Load case details under Load case 1 you have added all the live and dl of slabs what about self weight of columns and beams ????
@OnlineCivilDigital
@OnlineCivilDigital 11 жыл бұрын
thank you.. share to your friends too.
@onlyforstructuralengineers7443
@onlyforstructuralengineers7443 5 жыл бұрын
Should the response spectrum be added in all the three directions??
@MohamedAlmoflehengalmofleh
@MohamedAlmoflehengalmofleh 8 жыл бұрын
So Thanks fo the so helpful video and explanation
@teukumuhammadnafisbarizki4457
@teukumuhammadnafisbarizki4457 6 жыл бұрын
hello sir. thank you very much for the video. very helpful. I want to ask something, if i input custom spectrum value (T vs Acc in "g" unit), should i use the scale factor 9.81 to convert g unit to m/s2 (SI)? Thank you very much.
@OnlineCivilDigital
@OnlineCivilDigital 11 жыл бұрын
will upload as soon as possible.
@kuswantosolossawantosoloss863
@kuswantosolossawantosoloss863 7 жыл бұрын
thanks to video staad...
@manikandanthangaraj5333
@manikandanthangaraj5333 10 жыл бұрын
vy nice.. gud work.. the videos are vy helpful.. thank u
@OnlineCivilDigital
@OnlineCivilDigital 10 жыл бұрын
Thank you for your feedback..
@marcograssi3688
@marcograssi3688 6 жыл бұрын
Amazing man, you Rock!
@akashmahadevpatil
@akashmahadevpatil 3 жыл бұрын
Thanks Sir!
@onlyforstructuralengineers7443
@onlyforstructuralengineers7443 5 жыл бұрын
My result says like this... Story drift cannot be calculated for the response spectrum load case.Response spectrum computes joint displacements that represents maximum magnitude of the response quantity that is likely to occur during the seismic load. Any response quantity like story drift, torsional irregularity, etc should be calculated from actual displacements of each mode considered during the analysis. The response quantity from each mode should be combined using modal combination to get the maximum magnitude of that response quantity. Whats the solution for this?
@rajkumar-bd7yj
@rajkumar-bd7yj 3 жыл бұрын
sir, if give diaphragms then we should define reference load case (as mass load) , then under the mass load we have to give selfweight, member loads, floor loads in all directions X,Y,Z with positive sign it seems, my doubt was same pattern we are giving in Response spectrum case also, so if we give in reference load case shall I skip in response spectrum case or is it compulsory to provide both in reference load case and response spectrum load case??
@ozothegsd2701
@ozothegsd2701 3 жыл бұрын
While applying seismic weight shouldn't we take (1) Dead load & (0.25/0.3) Live load, instead of whole Live load assigned in Load Case 1. Pls correct me if I'm wrong.
@aslamrahman2748
@aslamrahman2748 3 жыл бұрын
Great work done by you. Very useful. Can you please upload the staad input file of this RS Analysis. I have repeated this analysis on my computer but results are slightly different. Want to understand why.
@markespinoza3721
@markespinoza3721 10 жыл бұрын
thank you sir...it helps a lot....
@rajeshkolte6982
@rajeshkolte6982 5 жыл бұрын
Thanks, very good information through this video, keep it up - I have query in load case 2- ie result shows all forces and moments as positive, how to account these for design ?. do you have some more video on this.
@vasimkajal5011
@vasimkajal5011 7 жыл бұрын
Nice Explanation of the method and very helpful too. sir, what shall be the difference if I wish to analyse an equipment foundation using same method from analysis to design (up to provision of reinforcement)?
@suliman9058
@suliman9058 4 жыл бұрын
Sir please , should we always apply I/R factor and why its applied? To compere with the static analysis,or it is essential factor for any dynamic response spectrum despite the static analysis
@hojefadhundhiyawala7271
@hojefadhundhiyawala7271 5 жыл бұрын
Hello, Its great video to understand response spectra. But i have doubt if we want to perform response spectra in X and Z direction so , i think we have to apply loads only in that two direction for response spectra load case. please reply..
@aarakshyakandel7741
@aarakshyakandel7741 9 жыл бұрын
thanks for a very helpful video. Couple of questions... 1. Why is the dead load value so big. I didnt see the brick loading being applied in the model . for seismic load i think the brick load being dead load should be applied 100% . or does the applied dead load includes brick load as well ?? 2. as questioned earlier by Akshay , wht abt the signs? thnks again for the well presented video.
@AnandPaul
@AnandPaul 9 жыл бұрын
+aarakshya kandel Dead load value will depend on the actual brick loads and codal loads. Values assumed here are only for demonstration purpose.
@AkshayKothiyal
@AkshayKothiyal 9 жыл бұрын
sir can you please tell me why we have used all loading in +ve direction specially in floor load loading direction should be in the -ve direction
@abhilekhprasai2750
@abhilekhprasai2750 8 жыл бұрын
+Akshay Kothiyal yes why has he taken all the loadings in +ve direction..when it should have been in the -ve direction.....even for the self weight ... (confused)
@mdtariqulislam2795
@mdtariqulislam2795 8 жыл бұрын
Thank You Brother
@sahil95213
@sahil95213 9 жыл бұрын
thanks for reply. but while defining response spectrum data we need to define code, and doing that there isn't any UBC code in drop down list. in that case shall i go to custom option??and in this option how we enter the UBC input data which is actually not matching. pls clarify
@suliman9058
@suliman9058 5 жыл бұрын
Is it possible to have more base shear with response spectrum than static method ? Some codes do not have modal response parameter factor (i/r)
@OnlineCivilDigital
@OnlineCivilDigital 11 жыл бұрын
Thankyou..
@onlyforstructuralengineers7443
@onlyforstructuralengineers7443 5 жыл бұрын
Can you please explain how to design the reinforcement of the structural elements using the Earth quake analysis results ?
@VTiger86
@VTiger86 6 жыл бұрын
Dear sir. Would you please explain to me the value that input to X direction in table of response spectrum X = (Z/2)x(I/R) = 0.036. Normally I always input 1.0 for this parameter. Thank you so much!
@ashashenoy4212
@ashashenoy4212 3 жыл бұрын
Please tell us load combination for Response Spectrum method
@nishimonkonwar2132
@nishimonkonwar2132 6 жыл бұрын
I have a query... when calculating the live load, the floor range given was 0 to 11 of 2kN/m, but in ground floor we don't consider Live load can you pls explain...
@gp19891
@gp19891 5 жыл бұрын
Hello sir, Is there requirement of defining seismic load cases before live load and dead load as it was in Static seismic analysis using response spectrum method?
@aminuddinraja1696
@aminuddinraja1696 10 жыл бұрын
sir...why i can't run the analysis results for storey drift??i'm trying to follow your video,but the results does not include the storey drift..
@suliman9058
@suliman9058 4 жыл бұрын
i have negative response spectrum story drifts why ? can you help please
@Sufiavd
@Sufiavd 10 жыл бұрын
do you have any tutorial on stack design, guyed wire and self supported structure.
@onlyforstructuralengineers7443
@onlyforstructuralengineers7443 5 жыл бұрын
Should be the response spectrum load case of seismic type?? because u have selected none
@siddharthsahu2897
@siddharthsahu2897 9 жыл бұрын
sir can i replace SRSS method and use CQC method and the remaing procedure same as in video.
@upasanakumar545
@upasanakumar545 5 жыл бұрын
yes, you can do that.
@ChinTanLimbani
@ChinTanLimbani 8 жыл бұрын
Nice one
@jacobscreek1681
@jacobscreek1681 6 жыл бұрын
Can u please explain the same process for an elevated circular tank
@nrupenpanchal1664
@nrupenpanchal1664 5 жыл бұрын
Can u share one model with response spectra analysis in all three direction with cqc method and how to interpret the results ?
@pinnacleeiit
@pinnacleeiit 3 жыл бұрын
How to take 12 kn /m2 as a dead load?
@soniyakhatri27
@soniyakhatri27 7 жыл бұрын
hello sir! Can you tell me how to give more no. of modes, if 6 modes are not sufficient? 'cause as per Clause 7.8.4.2, IS 1893 part 1, the no. of modes in the analysis should be such that the sum total of modal masses of all modes considered is at least 90% of the total seismic mass" . but in my analysis, it is only 78%. So what to do to give command for more no. of modes?
@ezhilarasans4581
@ezhilarasans4581 7 жыл бұрын
Select "Commands" from Menu Bar, under the drop down menu, select "Miscellaneous" sub option, then select "Cut off mode shape", then enter your desirable mode shapes.
@snjkumarbr
@snjkumarbr 6 жыл бұрын
Ezhil Aaron that doesn't works ...
@NeerajSingh-zw4jx
@NeerajSingh-zw4jx 6 жыл бұрын
is it possible to get storey drift in response spectrum analysis of building??
@sahil95213
@sahil95213 9 жыл бұрын
Hi, Thanks for uploading such an understandable video, would you mind pls let me know how can i use UBC or any other local code instead of IS. kindly response..
@AnandPaul
@AnandPaul 9 жыл бұрын
whatever the code be, the basic approach remains the same..you just need to understand the method first. Just open up some other code and try doing. its not that difficult as you think it is, and verify the results with some worked out examples..
@bhushanpatil5539
@bhushanpatil5539 3 жыл бұрын
Why only load applied in X direction 0.036
@pulkitmishra4918
@pulkitmishra4918 10 жыл бұрын
Sir, can you please upload the video regarding Pushover Analysis in Staad Pro, and please do tell me how I can carry out time history analysis without extracting input file?
@vinodsnk
@vinodsnk 5 жыл бұрын
Hi can you make a video for dynamic analysis of machine bed or turbo generator
@inamgay
@inamgay 11 жыл бұрын
I followed exactly as u did, but in the staad output, i don't get the Multiplying Factor (Vb/VB) and therefor i have no way of determining the scaling factor. i thought maybe its because of different staad version, but again when i downloaded ur staad file and analyze, it shows a note saying Multiplying factor (Vb/VB) is of some value. where do u think i am going wrong?
@shreyanshajmera6297
@shreyanshajmera6297 8 жыл бұрын
what if I don't get the total modal mass greater than 90 % of total seismic weight? how to consider number of mode shapes? do reply as it is very crucial for me.
@teukumuhammadnafisbarizki4457
@teukumuhammadnafisbarizki4457 6 жыл бұрын
It maybe too late but i ll try to ans it lol. In toolbar select COMMANDS> MISCELLANEOUS>CUT OFF MODE SHAPE. hope this will help
@snjkumarbr
@snjkumarbr 6 жыл бұрын
Even on changing number of modes....it is not increasing to 90...
@ChinTanLimbani
@ChinTanLimbani 8 жыл бұрын
Thanks u
@nemalavenkatesh
@nemalavenkatesh 9 жыл бұрын
Thats really fine, but is it possibe to show how to calculate response spectrum analysis in manual procedure.
@AnandPaul
@AnandPaul 9 жыл бұрын
+Venkatesh Nemala Please mail me, i will give you the reference doc.
@nemalavenkatesh
@nemalavenkatesh 9 жыл бұрын
+MrFanfinn thank you very much for your reply. i will check it.
@sougatadas6879
@sougatadas6879 6 жыл бұрын
please give a video showing load combination with response spectrum load
@AnjishaDesign
@AnjishaDesign 2 жыл бұрын
How to add pvc water tank load?
@tirade1000
@tirade1000 11 жыл бұрын
Can you provide the STAAD analysis through"Time history"analysis?I will be higly grateful...
@EMCGINC
@EMCGINC 10 жыл бұрын
Can you elaborate on time history method of dynamic analysis using staad ..thanks
@OnlineCivilDigital
@OnlineCivilDigital 10 жыл бұрын
Time History Analysis In Staad Pro v8i - Structures under Seismic Accelerations check out this link for time history analysis
@tirade1000
@tirade1000 11 жыл бұрын
Can you provide the video regarding time History analysis?
@OnlineCivilDigital
@OnlineCivilDigital 11 жыл бұрын
my pleasure..you can use the comment box to ask any doubts.. and share to your friends..
@meghasharma9636
@meghasharma9636 4 жыл бұрын
Acceleration scale after X value in response spectrum how to calculate
@mohamedberrabah1278
@mohamedberrabah1278 5 жыл бұрын
Hi Sir periode must be cheked
@GrazUralKamaz
@GrazUralKamaz 3 жыл бұрын
7 years ago ... Eh ? Our loss
@OnlineCivilDigital
@OnlineCivilDigital 11 жыл бұрын
namgay, can you paste the warnings if you are getting any, or paste here the description that you are getting instead of the NOTE.-" " . you can zip and mail me ur STAAD file to admin @civildigital. com
@apsarasharma445
@apsarasharma445 5 жыл бұрын
can you please share your email id for more information regarding the above analysis?
@rasmitapadhi8940
@rasmitapadhi8940 3 жыл бұрын
Help me sir plzz
@krishnakadiyam2864
@krishnakadiyam2864 6 жыл бұрын
change the file name bro pls... IS1893 not IS1983
@OnlineCivilDigital
@OnlineCivilDigital 6 жыл бұрын
Thanks for pointing it out. It was a typo.
@minhajmajeed
@minhajmajeed 11 жыл бұрын
like
Seismic Analysis of Multi-Story Buildings using the Response Spectrum Method
27:34
Dr Nafie - Structural Engineering
Рет қаралды 60 М.
Calculating Frequency & Mode Shape in STAAD - Eigen Value Extraction Method
13:25
So Cute 🥰
00:17
dednahype
Рет қаралды 56 МЛН
У ГОРДЕЯ ПОЖАР в ОФИСЕ!
01:01
Дима Гордей
Рет қаралды 8 МЛН
Apple peeling hack @scottsreality
00:37
_vector_
Рет қаралды 127 МЛН
Response Spectrum Analysis in STAAD (Part 2) explanation Video
10:29
OnlineCivilDigital
Рет қаралды 36 М.
IS 1893 (Part-1)2016 update in STAAD.Pro Connect Edition
32:10
Bentley Education
Рет қаралды 12 М.
Implementation of IS 1893 (Part 1):2016 in STAAD.Pro CONNECT Edition
53:37
Seismic analysis As per IS1893 2002 in Staad Pro best explained
15:19