2023 NEC changes: GFCI protection (210.8)

  Рет қаралды 105,556

Ryan Jackson

Ryan Jackson

Күн бұрын

Пікірлер: 560
@wonderfulbliss85
@wonderfulbliss85 2 жыл бұрын
Might as well just install dual function AFCI/GFCI breakers for the whole house and just be done with it.
@theodoreroberts3407
@theodoreroberts3407 2 жыл бұрын
I'm green (trying to get to be a journeyman), but that's the way I see it. If I do that no body will be mad at me later.
@anthonypicozzi7360
@anthonypicozzi7360 2 жыл бұрын
At this point we should price it that way
@estevaness
@estevaness 2 жыл бұрын
Would simplify things a lot.
@y2kmadd
@y2kmadd 2 жыл бұрын
Agreed. AFCI/GFI breakers for every circuit. Future-proof.
@Wintersky136
@Wintersky136 2 жыл бұрын
Totally agree! The NEC 2023 is just unnecessarily complicated in that maner!
@coreysalo1809
@coreysalo1809 2 жыл бұрын
Seems it would be easier just to list what doesn't need GFCI protection.
@sl06bhytmar
@sl06bhytmar 2 жыл бұрын
in Europe, you GFCI everything, Arc-flash protectors are becoming mandatory to wet & dwelling rooms.
@dporrasxtremeLS3
@dporrasxtremeLS3 2 жыл бұрын
E V E R Y T H I N G!!!
@Khaos-y7n
@Khaos-y7n 7 ай бұрын
Just make all breakers GFCI
@G.I.JeffsWorkbench
@G.I.JeffsWorkbench 6 ай бұрын
Thanks for paying close attention to NEC updates. Very helpful.
@jimzimmerman5288
@jimzimmerman5288 Жыл бұрын
The NEC should just make a code change to have every outlet to be GFCI protected. This has gone beyond crazy.
@G.I.JeffsWorkbench
@G.I.JeffsWorkbench 6 ай бұрын
And then in 2026 they’ll need to be AFCI/GFCI dual function.
@ditodant
@ditodant 7 күн бұрын
Mr Ryan l am an old man 56 years and I wash your videos every day, l am not speak English very well but l am learning , just want to say thank you and God blessed you , to you and you family, l don’t know if one day l try to do the exam but l go into continue with study with your videos because I love my job tank you
@RyanJacksonElectrical
@RyanJacksonElectrical 6 күн бұрын
@@ditodant Thank you so much for telling me that. I am happy to help, and I wish you all the best luck and success.
@jamesramos408
@jamesramos408 2 жыл бұрын
Thank you Ryan for your help and support for all of us Sparkys out here in the field.
@swiley4045
@swiley4045 2 жыл бұрын
I am a Home Inspector in Texas and your photo of the bathroom requiring the bedroom receptacle to be GFCI protected was spot on. I recently inspected a home where the GFCI receptacle was on the left side of the sink while the still plugged in curling iron was plugged in the non-GFCI receptacle. There was nothing plugged into the GFCI so my reasoning was the user of the curling iron was right handed and was more convenient since the GFCI was operating properly. I left the home owner a note explaining the danger but your videos are FANTASTIC and extremely helpful.
@robertmcenery4344
@robertmcenery4344 Жыл бұрын
If the bathroom was wired properly, the single GFCI outlet protects the other outlets in the bathroom.
@MR-nl8xr
@MR-nl8xr Жыл бұрын
Aren't "windows" by definition EXCLUSIVELY installed on EXTERIOR WALLS?
@z1522
@z1522 Жыл бұрын
@@MR-nl8xr As he so clearly tries to explain, a Window may be defined ambiguously. We had an old house, originally a log box circa 1920; during its multiple expansion/remodels, a garage space (later converted to large work studio) was added, and right there was one of the original windows, with sliding glass, facing not the great outdoors, but the work studio. "By definition" LITERALLY means one had better take the time to actually define every critical term used, whenever laws or codes are developed.
@ThunderClawShocktrix
@ThunderClawShocktrix 3 ай бұрын
if it was wired properly that outlet was hooked to the load side of the GFCI if not thats very dangerous as it could lure people into false sense of security
@ChrisTexan
@ChrisTexan 2 жыл бұрын
Thank you for this summarization! As a DIY homeowner on many projects, i prefer to follow all codes up to or beyond those required in my area, so this is excellent information to help in the "keeping up" process.
@stillthakoolest
@stillthakoolest 2 жыл бұрын
Looking forward to getting the book as I will be testing for JW under 2023 code. As always, love how you keep things concise and clear and use examples from the field. Mike Holt's videos are near unwatchable with all his tangents and fluff. Thanks
@supremeel555
@supremeel555 2 жыл бұрын
Love the channel brother. I am a safety manager in the construction industry. Just purchased the 70E book to study. Will need it as we are building a Data center near Dulles airport Va.
@salmanalhuthaifi9486
@salmanalhuthaifi9486 Жыл бұрын
I am an international student studying construction engineer. You are the best person to explain the electrical code Thanks
@rcinfla9017
@rcinfla9017 2 жыл бұрын
On the topic of GFI's for outside units, the "150 V or less to ground' might be mis-interpreted if a unit only has 240 vac feed with no neutral. It does have less than 150v to ground measured from either L1 or L2 to ground but the unit itself only runs on 240vac which is greater than 150v. Further confusing the interpretation is "if supplied by single-phase branch circuit" may be interpreted as 120 vac only branch circuit. I do understand the intent. After several years in my new house my 240 AC sprinkler pump died. When I went to install a new pump I discovered the ground wire was not originally connected to pump motor case. If the motor winding developed a short to case there could have been 120 vac on the case of pump to ground. Same can happen with an air conditioner metal case. The problem with mini-splits and some variable speed compressors is their switching power supplies for three phase inverter VFD have some small EMI bypass capacitors to metal case ground, so they meet EMI (radio interference emissions) specifications. This creates a small amount of current on ground wire that creates the GFI ground fault. Do you really think an A/C service shop replacing an old 240vac outside air conditioner compressor unit is going to get the old non-GFI equipped 240vac feed to outside unit upgraded with GFI breaker in fuse box?
@bradwilmot5066
@bradwilmot5066 2 жыл бұрын
Nice, so now the 20A breaker for a mini-split is $120 instead of $28... Don't tell me Square D et al. don't have their fingers in the pie that is the NEC...
@jeffbower5525
@jeffbower5525 2 жыл бұрын
Manufacturers (or any other group on the CMPs) cannot make up more than 1/3 of the CMP. It takes a 2/3 majority to pass any code change. So yes, you are incorrect.
@FJB2020
@FJB2020 2 жыл бұрын
They pretty much wrote every article about how great AFCI was and why we need them when they first came out... All about profits and nothing to do about "safety"...
@jeffbower5525
@jeffbower5525 2 жыл бұрын
@@FJB2020 you're opinion is incorrect.
@FJB2020
@FJB2020 2 жыл бұрын
@@jeffbower5525 'Your'
@jeffbower5525
@jeffbower5525 2 жыл бұрын
@@FJB2020 Thanks Mr. Grammar Nazi
@The360Electrician
@The360Electrician 2 жыл бұрын
Ryan, thanks for the update as always!
@blakesanders2671
@blakesanders2671 2 жыл бұрын
I’ve been waiting on these to start coming out from you. I learned so much from the last code cycle.
@theseattlegreen1871
@theseattlegreen1871 6 ай бұрын
So does the 30amp 240v dryer receptacle need GFCI in residential or not?
@RyanJacksonElectrical
@RyanJacksonElectrical 6 ай бұрын
Yes.
@foogod4237
@foogod4237 2 жыл бұрын
21:53 The wording was technically correct either way. Previously, it said "indoor damp and wet locations" meaning "indoor damp locations and wet locations". Now it says "indoor damp or wet locations" meaning "indoor locations which are damp or wet". Technically, "damp and wet locations" could be interpreted as either "(damp locations) and (wet locations)" or as "(damp and wet) locations", but as you said, it actually logically does not make sense for a location to be both damp and wet at the same time, so the phrase clearly must be intended to mean the former, not the latter. It arguably still doesn't hurt to remove the ambiguity if possible, though...
@Sparkeycarp
@Sparkeycarp 2 жыл бұрын
The commercial kitchen sink at 21:00 is in a stainless frame and counter. Wouldn't that extent the 6' rule as the entire countertop is conductive.
@fdonaldsonjr
@fdonaldsonjr Жыл бұрын
Just found your channel! Awesome content! Thank you for taking the time to help us to understand the NEC!!!
@tommilton5753
@tommilton5753 2 жыл бұрын
I replaced an old subpanel next to my main panel with a much bigger Siemens plug in neutral panel, and bought a collection of dual function breakers as well as a few GFCI and AFCI individual ones. I also moved some circuits from the main GE panel to the subpanel as the main panel was maxed out with half size breakers, all of which I removed and replaced the remaining circuits with DF breakers. What I have found is that none of my fridges or freezers (all relatively “quality” brands) like these GFCI breakers. Also my mitre saw cannot tolerate AFCI protection, but its ok with GFCI. So my question is “what, if anything, have appliance makers said or done about the compatibility of their products with these requirements?
@drewbrown9678
@drewbrown9678 2 жыл бұрын
Most all appliance techs will tell you to never install an appliance to a GFCI as explained in the installation manual….
@johnschroeder3072
@johnschroeder3072 2 жыл бұрын
Part of the issue with GFCIs is that unlike RCDs (name used in the reset of the world) that are rated with a type (AC, A, B, F) which determines the types of loads it is compatible with. 'AC' type are only really suitable with resistive or motor type loads (probably the type that most GFCIs are), 'A' type can operate with AC or Pulsed DC (rectified ) loads which is fine for most general electronics loads, 'F' type RCD's can work with loads with single phase frequency drives or VSDs. It might be worthwhile doing some investigation into the type of GFCI you have and what is available to find something more appropriate. As far as your circular saw tripping the arc fault there are probably 2 options, 1 is better quality arc fault detection the other is to check the brushes in your saw as that may be arcing more than necessary and being detected as a fault.
@jeffbower5525
@jeffbower5525 2 жыл бұрын
I actually made up an SO cord with cord cap that is 6' long from cord cap face to end of cord for measuring this. I obviously did not terminate the conductors in the cord cap.
@Re6nar
@Re6nar 4 ай бұрын
27:30 without any doubt… those ACs whips are romex from the disconnect to hole in the wall then into 3/4 lfnc to the unit. Romex outdoor. Done here in texas 80 percent of the time 🥴
@jamesbarca7229
@jamesbarca7229 2 жыл бұрын
It's adding a lot of cost if you already bought the AFCI and now you have to go back and buy a dual purpose one.
@johnschroeder3072
@johnschroeder3072 2 жыл бұрын
this is only for new/replacements not already installed equipment.
@isettech
@isettech 2 жыл бұрын
RV recpticals for most cases are a problem if GFCI protected as most older RV's have neutral and ground bonded due to having a generator. Does this requirement mean the RV has to be rewired with a unbonded neutral?
@jonsworld5307
@jonsworld5307 Жыл бұрын
it means stop reading the codes and wire it why people have for 100 years no one died yet lol
@Dezmond_Roman
@Dezmond_Roman 2 жыл бұрын
Dual function everything. Got it👍
@robertmcenery4344
@robertmcenery4344 2 жыл бұрын
The major appliances in my kitchen have been on GFCI for years. Kitchen sink is metal cabinet with stainless top. Appliances are all stainless steel. An older dishwasher I had, caught fire while running. The heating element apparently rusted and leaked, blew up, and blew out almost a foot of the coiled wire without breaking it, against the back of the plastic tub. The tub caught fire, causing molten, burning plastic to drip onto the floor and onto the 1/4 inch nylon water feed to the refrigerator. The plastic tubing developed a pinhole that sprayed water all over the back wall and under the dishwasher. Allowing the dishwasher to finish its cycle without burning my house down. Gallons of water covered the kitchen floor and rained into the unfinished basement. The new dishwasher has a stainless tub and a gfci service switch installed at the counter. My Whirlpool French door refrigerator tripped the gfci receptacle one day. I located the control board and traced the trouble to the ice maker. The heating element developed a high resistance short from hot to ground. The gfci tripped when the ice maker started to eject the ice and powered up the heater to free the ice from the tray to push it out. The gfci saved the refrigerator from damage to the control board and a melted wiring harness. All it needed was a new ice maker.
@stargazer2504
@stargazer2504 Жыл бұрын
On your refrigerator- I'm assuming you caught it before the food went bad? Because you'd need all new food to lol. Also similar to your dishwasher incident- My house had a short to ground which sent amps through the entire ground system without tripping breakers. Well, the cable tv system was bonded to all of this (per code) and it melted the coax. The coax turned orange and started a fire on the outer vinyl siding. The flaming, dripping vinyl siding dripped onto the PEX supply pipe running up the outside wall, melted a hole into the PEX, which sprayed out a steady stream of water ONTO THE SIDING which put out the fire and prevented the house from burning down. This all happened at 4am while we slept. Talk about luck!
@robertmcenery4344
@robertmcenery4344 Жыл бұрын
@@stargazer2504 WOW! That's 2 points in favor of plastic plumbing!
@z1522
@z1522 Жыл бұрын
You and @tracynation2820 present great object lessons, regarding the cost/benefit trade-offs, between obstinately refusing to accept NEC upgrades, and the "expense" related to a few hundred dollars of spoiled food. One burnt dishwasher, > $500; siding fire, plumbing leak and damage, a few $1000; burnt house, your call. A couple hours of electrician labor, and new receptacles or breakers, against all that other stuff, seems pretty obvious. Not even factoring in a 4 am fire and lives inside. But, hey, Freedom, and all that. Is your flag fire-resistant?
@robertmcenery4344
@robertmcenery4344 Жыл бұрын
You speak like someone who would be proud to keep a slightly damaged extension cord around because it still works fine. Then your daughter chooses it to power her iPhone while she's in the tub. Result: A sad ending to a teenage girl's life. But hey, FREEDOM.
@stargazer2504
@stargazer2504 Жыл бұрын
@@z1522 can you quote where my story stated I was "obstinately refusing to accept NEC upgrades" and "expense"? I was merely sharing a coincidental story that happened to us. Where do you get the idea that we were rebuking the NEC code for "our freedom" at the expense of our LIVES? Please explain, if you even can.
@Ittiz
@Ittiz 2 жыл бұрын
Definitely interesting. I'm not an electrician but in my state the homeowner is allowed to do their own electrical. Always check your state codes. Last year when I wired a minisplit (one that won't work on GFCI) my state hadn't adopted the 2020 NEC yet (whenever I tackle a large electrical project I always check). However they did so on July 1st this year and interestingly they specifically struck out the requirements for GFCI on outlets over 125V. So someone with sway in the statehouse didn't want to get with the times yet.
@lyfandeth
@lyfandeth Жыл бұрын
In my town, about the only thing you can change without pulling a permit is a light switch trim plate. Gotta love it, tax mafia.
@edevincenzo
@edevincenzo Жыл бұрын
Ryan, I just came across your channel. Great teaching. My wife and have low income investment property and always use licensed contractors but sometimes have disagreements on scope. Understanding the new requirements helps me ask the right questions up front and avoid the disagreements. Thank you for the timely teaching. I look forward to watching more of your videos.
@randallthomas5207
@randallthomas5207 2 жыл бұрын
Re the fan, you always install devices per the manufacturers instructions. And assume that they will include the ETL instructions.
@rupeinspections5611
@rupeinspections5611 8 ай бұрын
Thank you for clearing this up about the bathroom exhaust fans
@garbo8962
@garbo8962 2 жыл бұрын
Appears to be conflicting GFCI rules. Great that the GFCI for garage ceiling door opener receptacles must be readily accessible why 700# vending machines must have a GFCI built into cord believe within 18" of the male plug. Problem with that when there are rows of vending machines might need a trained rat to reset cord GFCI without getting a hernia moving machine. Thanks for another great vidio. When we wired in areas with more then 3 or 4 vending machines would try to install a panel nearby with a cover that can be locked to make it easier to secure it reset a circuit breaker.
@jovetj
@jovetj Жыл бұрын
If you came expecting common sense, you'll be sorely disappointed.
@ThunderClawShocktrix
@ThunderClawShocktrix 3 ай бұрын
whjy does the garage door opener even *NEED* to be on a GFCI though not somehting you are going to touch when went
@Nahum17good
@Nahum17good Жыл бұрын
Ryan, this is good information. Thanks for helping us electricians to interpret the new code.
@tracynation2820
@tracynation2820 2 жыл бұрын
Super. Back when I first started putting in GFCI outlets, three to five out of every ten I bought were bad or died within a month. Even back then I realized that it was a bad idea to have a GFCI in one bathroom protecting another bathrooms outlet, so I put a GFCI outlet wherever required. $40 each back then, but 100% customer satisfaction. They ought to just make every breaker a GFCI/AFCI mechanism, but if they do, I am going to stock up on regular breakers. 💙 T.E.N. Edit: I just removed the GFCI protection from my refrigerator, and installed separate heavy duty 120 volt 20 ampere NON GFCI/AFCI outlets, one in my garage, one in the hall, and one to the sump pump. Now I just plug the vacuum to the hall outlet, no more refrigerator dying, the sump pump will run until the power dies, and the garage one is for the tools and equipment that don't like AFCI protection, and for my RV, which trips an AFCI breaker, but not a GFCI, which was traced to an in vehicle battery charger. 💙 T.E.N.
@maxheadroom8857
@maxheadroom8857 2 жыл бұрын
If the refrigerator or freezer is made before the 90s code change requiring GFCIs on outlets near the sink in kitchens, that fridge or freezer might trip the GFCI. New ones are more likely to withstand tripping a GFCI. You can always use a battery backup pack to buffer the fridge and keep it running if a GFCI trips behind it. You will usually hear a backup beeping if a circuit trips.
@jovetj
@jovetj Жыл бұрын
@@maxheadroom8857 What kind of battery backup? The ones you use for computers? Those are not designed for inductive loads.
@maxheadroom8857
@maxheadroom8857 Жыл бұрын
@@jovetj An electronics shop might have a backup that will power a fridge
@dustinbergeron7508
@dustinbergeron7508 Жыл бұрын
So for the kitchen the code is stating all receptacles must be gfci protected. Does that mean just protection or does every receptacle have to be gfci. I know for a long time you can have a gfci and then duplex receptacles placed after the gfci and the duplexes will then be considered gfci protected. Did that ever change
@jovetj
@jovetj Жыл бұрын
GFCI _protected._ One GFCI receptacle protecting 7 downstream outlets is just fine. Most every GFCI comes with two sets of terminals or wires. The LINE terminals are for incoming power and, obviously, must be used for the GFCI receptacle to be of any use. The other materials are LOAD terminals, and these are protected by the GFCI just like the plug slots are. All wiring, wiring devices, and anything plugged in to the LOAD terminals are protected.
@johnmaranuk1842
@johnmaranuk1842 Жыл бұрын
Thank you, Ryan for these clarifications. Thank you for what you do for all of us. Its up to us to keep informed. So cheers, from Pennsylvania 👍
@VideoByPatrick
@VideoByPatrick 4 ай бұрын
Can you just put gfci breaker in main panel instead of multiple gfci outlets ?
@RyanJacksonElectrical
@RyanJacksonElectrical 4 ай бұрын
Yes, although the total leakage current of all combined circuits would need to be less than 4-6mA, otherwise the breaker would trip. That could work, but it also may not work for a given application.
@VideoByPatrick
@VideoByPatrick 4 ай бұрын
@RyanJacksonElectrical thanks, so code doesn't require gfci outlets in kitchen IF there is instead a main panel gfci breaker for kitchen outlets.
@garbo8962
@garbo8962 2 жыл бұрын
Not a bad rule about not having to protect ceiling fans with GFCI protection. In my 50 plus years as a sparky never saw the commonest style fan motor , A shaded pole ever short or ground out . Had the exact same type of motor on my early 1960's erector set 120 volt motors. Been years since I took a shaded pole fan motor apart but kinda remember that the enamel motor wire is only in contact with either a maroon fiber material or plastic vastly limiting those motor wire from grounding out.
@michaelstora70
@michaelstora70 2 ай бұрын
Ryan, I suspect a welder outlet would be a branch circuit but an RV outlet would be considered a feeder circuit.
@markavery2888
@markavery2888 2 жыл бұрын
Any idea how to wire commercial UPS units and comply with GFCI requirements? The common mode filters don't play nice and having power turned off for an item you are trying to keep on does not work well.
@news_internationale2035
@news_internationale2035 2 жыл бұрын
How's about when surge protection equipment gets old and leaks current to the ground wire? More having to replace surge protectors.
@theodorgiosan2570
@theodorgiosan2570 10 ай бұрын
How about 3 phase branch circuits in a dwelling unit? In my area high leg and 120/208 residential services are not uncommon, which means you have both a leg over 150v to ground and the capability for multi phase branch circuits. If, in a house with 3 phase, you ran a 3 phase circuit to the stove, installed a NEMA 18-50 if a wye service, or splice box if delta, and then put a cord on the stove with only single phase hooked up to a 18-50 plug or hardwired to the splice box with a single phase whip, would that really bypass the requirement for GFCI protection on that circuit? Same with cooktops, ovens, etc. If 3 phase was ran to the electrical box, and only single phase went out to the appliance, would that bypass the GFCI requirement?
@FJB2020
@FJB2020 2 жыл бұрын
Sure glad I don't have to worry about codes around here.. I would hate to shell out 3k in breakers just to pass inspection and tear them all out again and replace with normal ones..
@The_Ladder_Perspective
@The_Ladder_Perspective 2 жыл бұрын
🤣
@perspicacity1396
@perspicacity1396 2 жыл бұрын
What if equipment changes. Who is responsible if a fatality occurs after install due to new/rearranging of equipment??
@losboleros5261
@losboleros5261 Жыл бұрын
In your interpretation, does a readily accessible disconnect for a future AC in a dwelling require GFCI since you don’t consider it the outlet? Does the outlet not exist if the AC is not installed?
@brianerock
@brianerock 2 жыл бұрын
Great explanation, Ryan! FWIW, the TIA for 210.8(F) shown was for 2020 NEC®; HVAC could not meet THEIR OWN January 1, 2023, so TIAs and/or Appeals MIGHT extend this to 2025 or 2026.
@wm79198
@wm79198 2 жыл бұрын
Thanks for taking the time to make these videos for us. They’re Informative and we’ll presented. Tip for your viewers… spa disconnects come with a 50 or 60 amp GFCI breaker at a lower cost than buying the breaker separately. I’ll use those at the HVAC equipment for GFCI protection and the breaker at the panel for overcurrent protection. Especially since 2 pole 20 or 30amp GFCI breakers are turning into unicorns.
@jeffbower5525
@jeffbower5525 2 жыл бұрын
Most likely can't use a 50 or 60 amp spa disconnect as it will exceed the Max OCPD for the condenser.
@ChrisMeyersBigPickles222
@ChrisMeyersBigPickles222 2 жыл бұрын
@@jeffbower5525 as long as the breaker feeding the spa panel is the right size,, it would be fine, no?
@jeffbower5525
@jeffbower5525 2 жыл бұрын
@@ChrisMeyersBigPickles222 no, the branch circuit OCPD can't exceed the MOCPD on the nameplate. If you install an OCPD after the breaker in the panel you have made that the panel breaker is not the branch circuit OCPD but rather a feeder OCPD. I'll look at verbiage when I get home but I'm pretty sure this is how it ends up working.
@ChrisMeyersBigPickles222
@ChrisMeyersBigPickles222 2 жыл бұрын
No different than a 60 amp breaker feeding a sub panel with 100 amp Main
@jeffbower5525
@jeffbower5525 2 жыл бұрын
@@ChrisMeyersBigPickles222 You can't exceed the MOCPD rating (or 175% of the Motor compressor rated load current, whichever is greater) for the BRANCH CIRCUIT. If you use an OCPD at the disconnect the feeder OCPD value is irrelevant as part III of article 440 is for BRANCH CIRCUIT short circuit and ground fault protection. See 440.22(A) it specifically says branch circuit. So I am correct that you can't do this type install on the vast majority of the A/C installs.
@J-Jim
@J-Jim 2 жыл бұрын
Thanks for keeping us informed!
@solomoon100
@solomoon100 Жыл бұрын
Hi, I am trying to determine the maximum allowable ampacity of class 4 conductor. I read section N726.144 and it says it has to comply with 300.15. I have not found any information on 300.15. I have UL 1400-2 documents; it doesn't say much about the maximum allowable current on the UL document. can I use section 310.15 article this product?
@JohnThomas-lq5qp
@JohnThomas-lq5qp 2 жыл бұрын
Maybe 10 years ago at an IAEI class I questioned the instructor if heat build up with up to 40 AFCI in only a 14.5" wide panel will cause problems. Said UL tested panels with up to 80 AFCI circuit breakers and these was no problem with heat. Hard to imagine that if you have 80 very crowded #12 copper wires on both sides of a narrow panel. ( due to longer breakers ) that heat would build up.
@JMoney-ne3to
@JMoney-ne3to 6 ай бұрын
If you've sized things correctly, WHERE'S THE HEAT coming from???
@JohnThomas-lq5qp
@JohnThomas-lq5qp 6 ай бұрын
@@JMoney-ne3to Heat is produced any time a lot of current carrying wires are ganged together plus these breakers produce some heat. The large hospital that I retired from we had to perform an IR scan with expensive FLIR cameras on the over 10,000 circuit breakers every year. GFCI bolt on 20 amp circuit breakers always ran 2 to 3 degrees hotter.
@armyfazer1410
@armyfazer1410 2 жыл бұрын
I've watched this for 4 minutes. Subscribing, time now.
@bryanknudsen8100
@bryanknudsen8100 2 жыл бұрын
Guessing as with all other changes it primarily applies to new construction or remodels, but you mentioned in an example on a multi family dwelling where an AC unit needed to be replaced then the circuit would need to be upgraded to GFCI protection. Does that apply to all appliances? If say, for example, an over-the-range microwave has to be replaced, do you have to upgrade so the outlet is GFCI protected? It's not really a remodel, but it is in a loose definition a built in appliance.
@RyanJacksonElectrical
@RyanJacksonElectrical 2 жыл бұрын
No.
@drewbrown9678
@drewbrown9678 2 жыл бұрын
Microwaves Are cord and plug. Do you have to upgrade a range or dryer outlet to 4 prong when you buy a new dryer or range?
@danrowe79
@danrowe79 Жыл бұрын
This may be borderline but: in (4) buffet serving areas - does the buffet structure include ice wells to hold bottled beverages that may be uncorked and poured at the buffet structure? P.S. Thanks for a great video.
@thisgame1499
@thisgame1499 2 жыл бұрын
Hey Ryan, When applying 215.2 (A) (1) (b) for a continuous load, would you do the 310.14 calculations based off 100% or 125% of the continuous load?
@jimmiegill3981
@jimmiegill3981 2 жыл бұрын
Am I reading the 2020 wrong I am being required to gfi the finished part of a basement which when we could get duel function breaker no big deal but I think that I read only unfinished had to be gfi?
@RyanJacksonElectrical
@RyanJacksonElectrical 2 жыл бұрын
That's correct.
@brianerock
@brianerock 2 жыл бұрын
Jimmie Gill: GFCI protection is required for 125 - 250 V receptacle outlets supplied by branch circuits rated not more than 150 V TO GROUND in both unfinished AND FINISHED basements. The enforcement issue had been: • What constitutes “unfinished” versus “finished”? With modular (removable) basement finish systems, that becomes a “grayer” question. • Is there a difference in shock risk for unfinished versus finished basements? The answer was: no difference in shock risk.
@felixsandoval486
@felixsandoval486 2 жыл бұрын
Awesome 2023 start Ryan. Great video.
@shadedtree-
@shadedtree- 11 ай бұрын
So will ac on commercial build that are 208v 40a now need a gfci breaker. Or do this apply to residential dwellings
@MrTooTechnical
@MrTooTechnical 2 жыл бұрын
Great vid. When u going back on mike holt panel to be in his recordings???
@murrylonghurst3796
@murrylonghurst3796 Жыл бұрын
So have the building final inspection should be done before the equipment is installed
@bjcouche1
@bjcouche1 2 жыл бұрын
At this point, for dwelling units, it would be more straightforward to list the locations where GFCI is NOT required. I can think of a few, but they require AFCI, so at that point from a cost perspective, you might as well make all 120 and 240V circuits protected with combination AFCI / GFCI breakers.
@tonylee486
@tonylee486 Жыл бұрын
Does an IP66/68/69 rated receptacle (Leviton Rhino Hide Receptacle) also meet code for an outdoor weather resistant (WR) receptacle?
@theseattlegreen1871
@theseattlegreen1871 Жыл бұрын
You explain things so perfectly man. Mike Holt should take notes from you
@progression_decibel
@progression_decibel Жыл бұрын
To confirm something for us homeowners/DIY who are allowed to self-repair or upgrade, here is a question: My house was built in 2005 (and I fact checked back then it was built under NEC 2005 adoption). As of right now THIS MONTH (Feb 2023) my county still adopts the NEC 2020 code. Let's say adoption doesn't change over yet and I want to update/replace some receptacles this weekend. Which NEC year should I abide by? 2005, 2020, or 2023? I am sometimes confused if the home is "grandfathered" in with the NEC it was built under or I should use the currently adopted one. Of course as a savvy owner, I will always prefer to follow codes up to or beyond those required, but I am just curious the bare minimum. Again, this is for EXISTING work, not net-new. Thanks!
@RyanJacksonElectrical
@RyanJacksonElectrical Жыл бұрын
The scope the of the code is the installation of conductors and equipment. That means what you install must comply with the code that is adopted when you install it.
@kenevans6382
@kenevans6382 2 жыл бұрын
Depending on which state, city, or county you're in all this may or may not apply. If the jurisdiction chooses not to enforce the all of the NEC code AND SOME DO NOT, then it doesn't matter
@panelpal111
@panelpal111 Жыл бұрын
😂
@kenevans6382
@kenevans6382 Жыл бұрын
@@panelpal111 Thats just the way it is.....if the local municipality chooses NOT to adopt any part of the NEC it is NOT enforced.....
@ryanmiller1583
@ryanmiller1583 28 күн бұрын
Question for Bathrooms Outlets - If the branch circuit for an outlet is protected by a GFCI breaker then is it correct to say that GFCI outlets are not required for that area?
@RyanJacksonElectrical
@RyanJacksonElectrical 28 күн бұрын
@@ryanmiller1583 yes
@mustafaivoice5693
@mustafaivoice5693 Жыл бұрын
Could that GFCI or RCBO requirement apply on industry socket (Single phase-230V and 3- Phase 400V) or only on receptacle outlet
@rublar75
@rublar75 Жыл бұрын
I know this was made in 2022, but now, in 2023 that the code has officially come out, does the outside AC unit require GFCI protection? Am I misinterpreting what I heard here and what is in Exception 2? I'm seeing GFCI protection for HVAC equipment is NOT required. Exception No. 2: GFCI protection shall not be required for listed HVAC equipment. This exception shall expire September 1, 2026. Did they decide to extend it?
@ronbonick4265
@ronbonick4265 2 жыл бұрын
So is the kitchen table required to have a Receptacle? you can prepare food on it? where does it end?
@GeneralRock114
@GeneralRock114 Жыл бұрын
Can a GFCI breaker flip due to excess heat cause by our current excessive 105 outside temperatures making the breaker box hotter than usual????
@Doug-gp2qw
@Doug-gp2qw 2 жыл бұрын
I've been putting all GFCI receptacles in my own homes since the 90s. I used to use GFCI outlets because they are cheaper. Now I only use AFCI/GFCI breakers in my own homes. It's easier to go to one location to check and reset a circuit then to search behind beds or furniture for the first outlet on a circuit. It will also force you to address some existing wiring problems, if any. Usually its a neutral shared on more than one circuit. In that case the white neutral wire is often brown or even black from overheating.
@JohnQPublic345
@JohnQPublic345 Жыл бұрын
Don't you run out of positions on the neutral bar?
@Doug-gp2qw
@Doug-gp2qw Жыл бұрын
@@JohnQPublic345 It doesn't take any more spaces on the neutral bar. The circuit neutral goes to the breaker instead of neutral bar. Then the white wire from the breaker goes to the neutral bar. If you use a newer panel with a plug on neutral it reduces the number of wires going to the neutral bar.
@JohnQPublic345
@JohnQPublic345 Жыл бұрын
@@Doug-gp2qw oh yeah. I wasn't thinking
@dougpenrod8867
@dougpenrod8867 Жыл бұрын
But questions I got if you have a older home that don't have them like a 70 's home do I need update or only if I make a major remodel then have to do it and does apply for older Apts to
@saltyroe3179
@saltyroe3179 2 жыл бұрын
I guess if a window cannot be opened it is a fixed barrier?
@rupe53
@rupe53 2 жыл бұрын
some inspectors will cut you slack on a window that does not open. (screwed, glued, or caulked shut)
@jonathancall9967
@jonathancall9967 2 жыл бұрын
Are swamp coolers required to be GFCI protected?
@Trainman0401
@Trainman0401 5 ай бұрын
PLEASE HELP!!!!! It’s April of 2024. I just installed a 12000 BTU mini-split heat pump from Mitsubishi. It requires a 15 amp 220 circuit. I just learned (after getting the unit installed) that many mini-splits with variable speed compressors cause false trips when GFCI protected. If I begin to experience multiple faults after connecting it to a GFCI 220 breaker then what are my options …. if any? I am very worried about this. Is Mitsubishi at fault for selling units that won’t function properly under the new code?
@RyanJacksonElectrical
@RyanJacksonElectrical 5 ай бұрын
There was a Tentative Interim Amendment (TIA) that adds an exception to 210.8(F). It removes the requirement for GFCI protection for listed HVAC equipment until September of 2026.
@KrazyKajun602
@KrazyKajun602 Жыл бұрын
What is the code for bathroom Heat/Vent/Light? How many circuits needed and does it have to be AFCI/GFCI protected?
@RyanJacksonElectrical
@RyanJacksonElectrical Жыл бұрын
See 210.11 and 210.12.
@ronaldramirez3256
@ronaldramirez3256 Жыл бұрын
Hey Ryan min:24:18 Hvac systems have been exempted from requiring gfci on 210.8 (f) (3) exception No. 2. Can you confirm?
@RyanJacksonElectrical
@RyanJacksonElectrical Жыл бұрын
Correct. NFPA's Standards Council issued a TIA for both the 2017 and 2020 editions to add an exception that removes the requirement for listed HVAC equipment.
@chadgerman7467
@chadgerman7467 Жыл бұрын
As always, Amazing video!
@michaelcoelhojr6851
@michaelcoelhojr6851 2 жыл бұрын
Good stuff, great vid. I wish I got continuing education credit for this, this is better then Jade Learning!
@--JohnDoe
@--JohnDoe 2 жыл бұрын
@13:10 countertop receptacle spacing is off. 2' from the sink requires a receptacle. Am I wrong? Is that a peninsula or somthing?
@joeballard3027
@joeballard3027 2 жыл бұрын
Has any state adopted 2023 NEC yet? If so, who? If not when will states be able to adopt ?
@RyanJacksonElectrical
@RyanJacksonElectrical 2 жыл бұрын
It doesn't exist yet, so no. But Massachusetts will almost certainly adopt in Jan 1 of 2023.
@KameraShy
@KameraShy 2 жыл бұрын
How many states adopt the NEC statewide? In my state, the code is adopted by local governments.
@jovetj
@jovetj Жыл бұрын
@@KameraShy Good question: I'd venture to say the majority do. My state adopts a NFPA 70 and then "significant jurisdictions" (as legally defined) are allowed to adopt/modify that.
@Sembazuru
@Sembazuru 2 жыл бұрын
Hopefully the cost will go down for the breakers. For my own home, all of my breakers are the dumb style so I was considering swapping all of them and only returning back for the branches with unacceptable nuisance trips. So to get an idea of the cost I looked up the price of breakers at my local big-box store. The price of normal breakers for my box brand were about $7USD. The AFCI for my box brand were about $70USD. That's a full magnitude of order. If (for nice round numbers) I were to replace 10 of them I'd be looking at $700 in material cost alone to replace about $70 worth of breakers as a DIY project. Probably much more to hire a professional (I'm a trained electronics tech, not an electrician).
@jeffeverde1
@jeffeverde1 2 жыл бұрын
In a new install, that's slightly mitigated by eliminating the need for GFCI receptacles.
@BigGuy8059
@BigGuy8059 2 жыл бұрын
Look up a 2 pole GFCI for a 50 amp stove circuit: You will be shocked at the cost.
@jovetj
@jovetj Жыл бұрын
@@BigGuy8059 Square D (QO) 250V 50A -AFCI- /GFCI Circuit Breaker _only_ $145 on Amazon at the time of this writing. I wonder what the AFCI-combo version will cost; can't find one right now.
@z1522
@z1522 Жыл бұрын
I have to laugh when any home owner laments the "expense" of upgrades that might not match their annual beer budget. Further, these are pretty fundamental upgrades, and at least would help avoid a destructive fire, which in turn might trigger an insurance investigation - and if flagrant violations or neglectful maintenance by the owner was demonstrated, your claim might be denied. Heck, a total revamping of a service panel might even get you an insurance rate reduction. A man often credited with advancing the idea of electricity is often credited, but the expression pre-dates him: "Penny wise and pound foolish."
@triaxe-mmb
@triaxe-mmb 7 ай бұрын
Not a contractor here - learning so i can be sure a remodel is done right... Why cant we just AFCI+GFCI the entire house... How much more could thst possibly cost...and whats the issaue with doing it that way?
@RyanJacksonElectrical
@RyanJacksonElectrical 7 ай бұрын
You can certainly do it. I know plenty of people that have.
@triaxe-mmb
@triaxe-mmb Ай бұрын
​​@@RyanJacksonElectricalno idea how I missed this response. Good thing this popped up again in my feed...my home is not complete yet. I will be telling my contractor to do this... hopefully he doesn't scream at me or kill me with a ridiculously large CO, 😆
@garfieldwood8315
@garfieldwood8315 2 жыл бұрын
10:00 "... it probably isn't adding that much to the cost..." Sounds like politicians -not their money being spent. FACT: a little here, a little there ADDS UP TO A LOT IN THE END. More like manufacturers' lobbying to ADD MORE SALES AND PROFITS..
@jonsworld5307
@jonsworld5307 Жыл бұрын
exactly what it is conter tops and bathrooms weres there water yes eery were else no thanks
@cet4602
@cet4602 2 жыл бұрын
Great stuff here Ryan, looking forward to your book!
@stevenscott6337
@stevenscott6337 Жыл бұрын
read 210.8(B)(4) again. it says, ".....provisions for FOOD SERVING, beverage serving, or cooking." Yes, that was a food serving area. Doesn't state whether it's self serving or staff serving. GFCI required.
@PhilMyCrackin-qd3lk
@PhilMyCrackin-qd3lk Жыл бұрын
Great information Sir. Sooner or later every outlet in a home will be GFCI protected. Just wait for it.
@lpnelson6584
@lpnelson6584 Жыл бұрын
That's probably a good assumption.
@gregmartin1757
@gregmartin1757 2 жыл бұрын
it's easy to talk about all these requirements like it's no big deal and i understand it all comes down to safety And while i agree with about 98% of the codes some go overboard and are completely unnecessary and juzt don't make sense plus when your a contractor all the constant calls due to nuisance tripping of all these gfci/afci breakers is a serious annoyance, nobody wants to be spending hours every week just driving around resetting breakers because it's amazing how many home owners don't know how to reset these .
@williamlabarre4755
@williamlabarre4755 2 жыл бұрын
In your 210.8(B) example with the icemaker, I would argue conservatively that the stainless(conductive) sink table and the icemaker is the relevant measurement. Perhaps even the stainless(conductive) cabinet it sits on. (3 inches?) Another question: these changes seem to include EVSE equipment, which often include GFCI internally. True? Great video, thanks!
@garbo8962
@garbo8962 Жыл бұрын
While on stainless steel or any other kitchen sink made from metal a continuing education class instructor/inspector said that all kitchen sink that have Pvc drain, PEX water supply and no garbage disposal must be have sink grounded. Been years since I saw a house without a garbage disposal but a guy that I did work for and owns over a dozen old rental houses a lastly a remove the garbage disposals because of too many problems.
@williamvangundy3358
@williamvangundy3358 2 жыл бұрын
210.8(B) 7: Could it be argued that since that sink is installed in a conductive metal counter; the edge of the sink electrically extends all the way to the edge of that counter?
@ThunderClawShocktrix
@ThunderClawShocktrix 3 ай бұрын
id say yes
@johndavies2949
@johndavies2949 10 ай бұрын
Well yes, the 120v service receptacle is gfi. But the condenser/compressor does not. The reference you give says less than 150 volts. It doesn't say 150 volts to ground. Most all outdoor ac units are 240 volts between the two suppl conductors conductors
@johndavies2949
@johndavies2949 10 ай бұрын
I'm wrong.
@GH-oi2jf
@GH-oi2jf 2 жыл бұрын
When I plug in a device that has no on/off switch (my phone charger) I see a tiny arc as it connects. Would that trip an AFCI? I don’t have any so can’t test it.
@johnschroeder3072
@johnschroeder3072 2 жыл бұрын
If a AFCI is designed and made correctly no, if it's not then possibly
@yellow8954
@yellow8954 Жыл бұрын
Where can i read more on these electrical related deaths that you mentioned
@SEPNWMAN
@SEPNWMAN 2 ай бұрын
In the process of wiring my house. Glad the Home Depot has a good return policy because as soon as my inspection is done I'll be returning all the unnecessary gfci breakers and returning $$ to my account!!!
@timflory4767
@timflory4767 2 жыл бұрын
I'd like to know the thinking behind requiring gfci protection for ranges clothes dryers ,ac units, and garage door openers when u have them connected to a properly sized grounding comductor ? I've ask this before but never received an answer .
@jovetj
@jovetj Жыл бұрын
Someone died.
@jonsworld5307
@jonsworld5307 Жыл бұрын
@@jovetj yep one stupied guy put hes hand in live wire and everyone else hads to change to retired proof it
@johnschroeder3072
@johnschroeder3072 2 жыл бұрын
On AirCons with frequency converters in them why aren't they just required to use GFCI's that are designed for that load rather than standard ones which are really only designed for resistive or motor loads?
@Crazypug-eh7xi
@Crazypug-eh7xi 2 жыл бұрын
Outstanding!! Thanks for breaking it down
@perspicacity1396
@perspicacity1396 2 жыл бұрын
Why not permanent provisions for cooking preparing or Serving? Serving being the word in question
@62Cristoforo
@62Cristoforo Жыл бұрын
A false sense of security. There’s an old KZbin video floating around showing a guy gently lowering a running hair dryer into a filled tub. It is plugged into a GFCI outlet and guess what happens? Nothing. The motor just keeps on spinning, but instead of heated air it’s now throwing out a stream of heated water. There’s no detectable difference between incoming and outgoing current to signal the GFCI sensor to trip itself, so it keeps running. Anyone sitting in that tub wouldn’t make it out alive, even with the GFCI “protection”.
@jonsworld5307
@jonsworld5307 Жыл бұрын
its about the money not your safety
@sammyjimsmith6100
@sammyjimsmith6100 11 ай бұрын
WHat about gas stoves, are they on 120v?
@papabiker2
@papabiker2 Жыл бұрын
I'm an electrical contractor in MN and received an email last fall from of my electrical inspectors with an attachment from NFPA (2023 addition) stating: Reference: 210.8(F) and Exception No. 2 (new)TIA 23-3 1. Revised paragraph 210.8(F) to read as follows: 210.8(F) Outdoor Outlets. (...I'll skip down to Exception 2. ) Exception 2. GFCI protection shall not be required for listed HVAC equipment. This exception shall expire September 1, 2026. Issue Date : August 12, 2022 Effective Date: September 1, 2022
@stucorbett7905
@stucorbett7905 9 ай бұрын
Is it true that Utah has exempted itself from the NEC residential? I had an inspector tell me that 2 yrs ago. Utah inspector.
@RyanJacksonElectrical
@RyanJacksonElectrical 9 ай бұрын
Utah uses the IRC for residential and has for about twenty years.
@sorinmarkov5331
@sorinmarkov5331 6 ай бұрын
I agree dual function breakers for everything aside from the circuit the smokes are on.
Kitchen islands and peninsulas in the 2023 National Electrical Code
17:14
Feeder taps and the 2020 National Electrical Code
28:25
Ryan Jackson
Рет қаралды 65 М.
啊?就这么水灵灵的穿上了?
00:18
一航1
Рет қаралды 57 МЛН
Who’s the Real Dad Doll Squid? Can You Guess in 60 Seconds? | Roblox 3D
00:34
Synyptas 4 | Арамызда бір сатқын бар ! | 4 Bolim
17:24
Where and Why Do We Need AFCI Protection?
12:45
Electrician U
Рет қаралды 164 М.
Raceway (conduit) Fill Pt 1
39:38
Ryan Jackson
Рет қаралды 14 М.
2023 230.85 Emergency Disconnect
15:19
Ryan Jackson
Рет қаралды 10 М.
2020 NEC changes series: 110.14 Conductor Terminations
23:28
Ryan Jackson
Рет қаралды 82 М.
2023 NEC Changes GFCI protection 210.8 Big Changes!
10:46
Electrical Code Coach
Рет қаралды 26 М.
5 Formulas Electricians Should Have Memorized!
17:00
Electrician U
Рет қаралды 961 М.
How to Bond Neutral and Ground With 2023  NEC Code Book and Handbook
7:08
啊?就这么水灵灵的穿上了?
00:18
一航1
Рет қаралды 57 МЛН