Septum and Liner | ENG | Nexis GC-2030 | Shimadzu

  Рет қаралды 18,599

Troubleshooting Tips & Tricks by Shimadzu

Troubleshooting Tips & Tricks by Shimadzu

Күн бұрын

Пікірлер: 5
@bakryelreef5285
@bakryelreef5285 2 жыл бұрын
I used shimadzo 2014 now i Faced problem about the Flow of carrier not increased and the temperature of injector, . coloumn. And detecor not increased also
@jonheblanco2737
@jonheblanco2737 3 жыл бұрын
A cordial greeting, where I can obtain information on the frequency with which consumables or parts should be replaced either from the injection port, column or detector
@ajchromatography
@ajchromatography 2 жыл бұрын
Hello Jonhe. In Real Time Analysis window, you have the info on the Injection Port consumables shown in the panel to the right. However, the frequency of replacement of injection port parts and the column strongly depends on the analyses you perform on your system. Generally, if you inject 'clean' solutions (like if you're analyzing ethanol for methanol and other impurities content), you don't change liner and column too often (some analysts don't change liners for a year and until serious peak deterioration occurs, while the column would require only trimming throughout 2-3 years, then replace column). But if you're analyzing samples with high matrix load (such as QuEChERS extracts for pesticides), then you have to often replace liners, columns, and even syringe. But it all strongly depends on matrices you inject. In any case, it is a good practice to replace septum regularly as puncturing with a needle worsens sealing. If it comes to the detector, the maintenance varies for specific types of detectors. Generally field service engineers would manage maintenance and cleaning of detectors, although some actions may be performed by the laboratory staff -- it depends on the specific detector and level of the problem.
@attallahhouaria9861
@attallahhouaria9861 5 жыл бұрын
How to change the seringue
@scienceisnotfun2857
@scienceisnotfun2857 3 жыл бұрын
good but annoying and distracting music in background...
Selecting a GC Inlet Liner
2:42
Restek Corporation
Рет қаралды 18 М.
ЗНАЛИ? ТОЛЬКО ОАЭ 🤫
00:13
Сам себе сушист
Рет қаралды 2,6 МЛН
Миллионер | 2 - серия
16:04
Million Show
Рет қаралды 1,7 МЛН
What's in the clown's bag? #clown #angel #bunnypolice
00:19
超人夫妇
Рет қаралды 32 МЛН
Shimadzu GC Column Ferrules
15:49
ShimadzuMidwest
Рет қаралды 74 М.
Liner- und Septumwechsel | DE | Nexis GC-2030 | Shimadzu
2:35
Troubleshooting Tips & Tricks by Shimadzu
Рет қаралды 3,9 М.
Nexis GC-2030
2:52
Shimadzu Analytical and Measuring Instruments
Рет қаралды 28 М.
Shimadzu AOC-20i Change Syringe
3:27
ShimadzuMidwest
Рет қаралды 36 М.
ClickTek | ENG | Nexis GC-2030 | Shimadzu
1:16
Troubleshooting Tips & Tricks by Shimadzu
Рет қаралды 4,8 М.
Split vs. Splitless Injection
4:41
Restek Corporation
Рет қаралды 126 М.
GC - Gas Chromatography - Split & splitless injection Animation HD
4:05
MrSimpleScience
Рет қаралды 101 М.
GC Troubleshooting-Split Peaks
2:03
Restek Corporation
Рет қаралды 34 М.
Shimadzu GC-2014 Injector Maintenance
11:09
ShimadzuMidwest
Рет қаралды 43 М.
LabSolutions LC/GC Workstation Basic Data Analysis
8:56
Shimadzu Analytical and Measuring Instruments
Рет қаралды 124 М.
ЗНАЛИ? ТОЛЬКО ОАЭ 🤫
00:13
Сам себе сушист
Рет қаралды 2,6 МЛН