Service visit to Viessmann Vitoden 200 with plate heat exchanger separation

  Рет қаралды 2,663

Andrew Millward Watford

Andrew Millward Watford

4 жыл бұрын

Service visit to Viessmann Vitoden 200 Hydraulically isolated via plate exchangers.
A job with an interesting history. The original boiler installed at this property had constant breakdowns caused by the build up of scale within the boiler. Three years ago a new Vitodens 200 was fitted and hydraulically isolated by replacing the old low loss header with plate heat exchangers. The new boiler now protected from the introduction of contaminates from the system is clean and undamaged and running as designed.
#viessman #plate heat exchangers

Пікірлер: 13
@1991elliot
@1991elliot 3 жыл бұрын
Hi Andrew, my comment on your other video re SWEP plates, these two here are actually part of the SWEP E8 series.
@jamiewilliams685
@jamiewilliams685 3 жыл бұрын
Great video.
@ashbyts3900
@ashbyts3900 Жыл бұрын
Hi Andrew, Great video a few queries regarding domestic use. I currently have a Viessmann 200 W installed with a Spira-Cross low loss header fitted, light industrial pump to add to the circulation but in just over 3 years I've ditched two heat exchange plates. I've spoken with the plumber regarding dirt separation but the header should take care of this, I've also mentioned the hard water within our area and possibly installing a water softener. Do you think this could help??
@normanboyes4983
@normanboyes4983 3 жыл бұрын
Really interesting Andrew. I think you have most definitely got to the bottom of it. I have often thought that water chemistry maintenance is the achilles heel of a traditional wet central heating system, which forms multiple cells between copper pipework and steel radiators. Your hydraulic separation is effectively protecting the boiler by removing it from the influence of the corrosion cells and acidic effects. I would expect in ‘traditional’ systems it is likely that primary circuit water is acidic even in serviced boilers. Have you done any assessment on the effect on thermal efficiency of introducing the plates? Of course the improvement in reliability (and life) of the boiler is the no brainer criteria.
@andrewmillwardwatford9410
@andrewmillwardwatford9410 3 жыл бұрын
We get a 3 or 4 c temperature lift across the plate but are already using low temperature design so a very small compromise. A direct system will loose efficiency in the main heat exchanger due to fouling I believe leading to far greater efficiency losses. The systems are ph adjusted to 9.8 if no aluminium is present.
@normanboyes4983
@normanboyes4983 3 жыл бұрын
@@andrewmillwardwatford9410 Thank you Andrew - excellent.👍
@Sash_Window
@Sash_Window 4 жыл бұрын
Plate separation, I'd like to know more on this please.
@andrewmillwardwatford9410
@andrewmillwardwatford9410 3 жыл бұрын
What would you like to know ?
@Benzknees
@Benzknees 3 жыл бұрын
Would a low loss header also do the job of equalising different flow rates & collecting dirt in the system? What are the criteria for choosing either this solution or plate separation?
@andrewmillwardwatford9410
@andrewmillwardwatford9410 3 жыл бұрын
Yes almost the same
@dominichalliday8929
@dominichalliday8929 4 жыл бұрын
Hi , if the water was clean and properly dosed how was it damaging the previous boiler?
@jamiewilliams685
@jamiewilliams685 3 жыл бұрын
Good question.
@andrewmillwardwatford9410
@andrewmillwardwatford9410 3 жыл бұрын
Im not a chemist but have looked at water quality and treatment and found that some systems just can't be cured. Rather than chase my tail seperation is a total fix for the issue.
Vitocel 200 and Vitodens 200 with plate heat exchanger separation.
9:22
Andrew Millward Watford
Рет қаралды 2,5 М.
A clash of kindness and indifference #shorts
00:17
Fabiosa Best Lifehacks
Рет қаралды 133 МЛН
Spot The Fake Animal For $10,000
00:40
MrBeast
Рет қаралды 176 МЛН
Sigma Kid Hair #funny #sigma #comedy
00:33
CRAZY GREAPA
Рет қаралды 37 МЛН
Pleased the disabled person! #shorts
00:43
Dimon Markov
Рет қаралды 27 МЛН
Plate Heat Exchanger Applications and working principle hvac heat transfer
10:18
The Engineering Mindset
Рет қаралды 163 М.
My biggest Project so far
11:43
Andrew Millward Watford
Рет қаралды 2,5 М.
Do we need buffers or hydraulic separation with heat pumps?
9:57
Andrew Millward Watford
Рет қаралды 3,2 М.
another project with boiler Trust
5:03
Andrew Millward Watford
Рет қаралды 1 М.
How the Amish have HOT WATER! Off Grid Living
8:58
OFF GRID with DOUG & STACY
Рет қаралды 1,4 МЛН
plate separation with electronic mixing valve
3:23
Andrew Millward Watford
Рет қаралды 3,5 М.
Plate Separated Viessmann 200 W
1:35
Griffiths Heating & Renewables
Рет қаралды 801
heat pump problems being rectified
6:24
Andrew Millward Watford
Рет қаралды 1,5 М.
A clash of kindness and indifference #shorts
00:17
Fabiosa Best Lifehacks
Рет қаралды 133 МЛН