Setting Up A Megger MFT for Continuity and Insulation Resistance Tests (How to set up a Tester)

  Рет қаралды 59,814

GSH Electrical

GSH Electrical

Күн бұрын

Пікірлер: 28
@MMG_MoonManGuitar
@MMG_MoonManGuitar 6 жыл бұрын
Thanks for this. Useful tips.
@davidroche6973
@davidroche6973 6 жыл бұрын
Thank you GSH, look forward to the future checkbox video
@GSHElectrical
@GSHElectrical 6 жыл бұрын
Hi thanks for the comment. Check box video will be next year. Have a great festive season and thanks for watching GSH Electrical
@eotlati1763
@eotlati1763 2 жыл бұрын
Watching this give me confidence to do ring testing.
@shaunbeard593
@shaunbeard593 6 жыл бұрын
thanks for the link
@duckman5642
@duckman5642 5 жыл бұрын
Great vid cheers.
@sn2319
@sn2319 2 жыл бұрын
Very useful videos, thanks for it. One question I wonder you have not given any tips for 3 leads live tests? Thanks
@georgedumitrescu9473
@georgedumitrescu9473 3 жыл бұрын
Hi Gary. Absolute brilliant videos. All of them. Just one quick question - how do I get to see the “private videos “ please. Thank you.
@GSHElectrical
@GSHElectrical 3 жыл бұрын
George Dumitrescu I have 62 videos ready for release over the coming year. New video every Sunday at 10 am 🦾.
@georgedumitrescu9473
@georgedumitrescu9473 3 жыл бұрын
Thank you Gary. I am looking forward to watch them. Good work and well done!
@kobeyossef5903
@kobeyossef5903 6 жыл бұрын
.HI can you make video how to Check problems at the socket .what should be the reading between Hot-neutral. Hot- earth and Neutral-earth
@jtdata622
@jtdata622 5 жыл бұрын
Can anyone recommend a first MFT for me want a megger. Done a bit of research and 1731 is same price as 41?? Plus a few people have said don’t bother with this new software for saving results as it’s rubbish. Any advice or stockists would be great
@Herendill
@Herendill Жыл бұрын
When I connect the leads I got the value about 0.2ohm. but when I pick them up or move, the values change even up to 5 ohms. The connection is solid but the value change. I tried to move just the cable itself and it seams that it changes the values. Why could that be? I got the tester refurbished with calibration
@acelectricalsecurity
@acelectricalsecurity 5 жыл бұрын
Can any manufacturer explain why they supply a red test lead, they have changed from black to blue, but have stuck with red rather than brown.
@alinili5569
@alinili5569 5 жыл бұрын
You are right I have 2 fluke and new megger 1721 But when I ordered new set of test lead from fluke instead of red came brown with fluke sign on it I be never seen anyone else have brown But it works
@VillainGang.
@VillainGang. 6 жыл бұрын
Fluke sticker on megger?? But nice video. Thumb up
@GSHElectrical
@GSHElectrical 6 жыл бұрын
Hi. Fluke had a have price calibration day on so we went for it. Thanks for watching GSH Electrical 👍
@seandempsey9396
@seandempsey9396 4 жыл бұрын
How about doing a video on the Robin metres, the are still complyant after all, these new models are over priced and bulky, just my own opinion I have used ROBIN MFT since last late 80s And never had any problems. But an other great video from Gary
@piotrlyczba9247
@piotrlyczba9247 3 жыл бұрын
Hi,can you please explain why when testing Z you can use either 3lo,2lo and 2hi,but when using Zs you can only use 2hi and 3 lo option.Thank you in advance.
@Mr.Q852
@Mr.Q852 3 жыл бұрын
When you’re testing between L-L or L-N no rcd will trip so there is no need for the setting to be present.
@piotrlyczba9247
@piotrlyczba9247 3 жыл бұрын
@@Mr.Q852 thank you for your comment,what I meant is that in megger 1711 when the left knob is in the L-PE position and the right one is in the Z position you have got three settings to choose 3lo,2lo and 2high but when you change the right knob into Zmax than you can only choose 3lo and 2high.Why there is no 2lo setting any more since you still test between L-PE so rcd can trip.I thought Zmax is there only to register the highest value if you test lets say couple of sockets.So the setting 2lo still should be available.Maybe I just do not get something.Anyway thank you in advance for your answer.
@mrw1584
@mrw1584 2 жыл бұрын
The reason the MFT only gives you the option for 2hi and 3lo on ZS is because 2lo is not a preferable or accurate measurement. When you have 3 leads connected in the back of the tester it assumes you have 3 cores available to test, thus not needing 2lo. 2hi is the most accurate fastest test but is only useful when no RCD’s are in circuit. 2lo is used on for example a light switch with a Line & CPC and no neutral but on a RCD protected circuit that cannot handle 2hi. 3lo is generally used on circuits where all cores are available to test but RCD is present. As i say for accurate Live tests and PFC or ZE measurements 2 hi is recommended for use in the Megger MFT Instruction Manual. Hope this helps👍🏻
@sherkoahangari4401
@sherkoahangari4401 6 жыл бұрын
Thank you
@GSHElectrical
@GSHElectrical 6 жыл бұрын
Hi. Thanks GSH Electrical
@roymillar4895
@roymillar4895 4 жыл бұрын
Does anyone just get to the test let's assume the meter is in date works and cables are not falling apart and hopefully we can all see what colour they are or really don't proceed
@emilgemc8913
@emilgemc8913 2 жыл бұрын
They have put Fluke name on Megger serial number 😂😂😂😂
@GSHElectrical
@GSHElectrical 2 жыл бұрын
😂😂😂🤫
How to use Megger MFT1700 Series
18:46
MeggerUK
Рет қаралды 88 М.
Why Is He Unhappy…?
00:26
Alan Chikin Chow
Рет қаралды 111 МЛН
黑天使遇到什么了?#short #angel #clown
00:34
Super Beauty team
Рет қаралды 44 МЛН
Challenge matching picture with Alfredo Larin family! 😁
00:21
BigSchool
Рет қаралды 41 МЛН
Идеально повторил? Хотите вторую часть?
00:13
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 18 МЛН
An idiot's guide to Megger 1741+  MFT
12:51
ELECTRICIAN TV
Рет қаралды 15 М.
Megger MFT1741 Review and Demonstration
51:37
John Ward
Рет қаралды 135 М.
The Heavy Machinery Gear Broken Was Very Professionally Repair by Genious Mechanic…
21:48
Why Is He Unhappy…?
00:26
Alan Chikin Chow
Рет қаралды 111 МЛН