Subscribe: mmini.me/Subscribe-4-Updates Other socials: Facebook: facebook.com/OnlinePLCSupport LinkedIn: www.linkedin.com/in/shane-welcher-sr/
@camalo171 Жыл бұрын
Daaaaaaang. Exactly what I needed. Thank you!!!!
@ShaneWelcher Жыл бұрын
Glad it was helpful
@ajayjoseponda1Ай бұрын
Amazingly helpful video . Thank you ❤
@ShaneWelcherАй бұрын
@@ajayjoseponda1 Welcome
@jbrenkendorff87634 күн бұрын
Thank you. Exactly what I needed.
@ShaneWelcher4 күн бұрын
@@jbrenkendorff8763 Great
@JohnSmith-rm7mh Жыл бұрын
Thanks for this. I knew it was possible but you made it faster by laying it out. You rock sir.
@ShaneWelcher Жыл бұрын
Thank you for the kind words
@bobstretz7142 Жыл бұрын
Just what I was looking for! I couldn't go offline with the PLC. I've done this before, but couldn't remember the instruction. Thanks!!!
@ShaneWelcher Жыл бұрын
Glad I could help!
@frank8424 Жыл бұрын
Wow thanks, I don't program but work with controls for multiple lines. Was asked to have current value come in on an auto audit from another program and needed to see current from the 525. I tried a few things and during down time downloaded but it didn't like it and had to go back. This may work for me. Of course not being a programmer I'll watch it a few times lol thanks. Subscribed!
@ShaneWelcher Жыл бұрын
Let me know where I can help
@markbernard4992 жыл бұрын
Thanks for the video, What would you enter in the destination element and/or service type if you wanted to get instance 13 (for example) which consists of different data types. (DPI read basic)
@ShaneWelcher2 жыл бұрын
Just make sure the data type of the drive parameter you want to read is the same data type as the tag you made to receive that data. It really is that simple, just look at the VFD's parameters to understand what data type you are trying to read.
@oliesting49213 жыл бұрын
Hi Shane love your videos. I just enrolled in your batching station course on your website. I have not seen comment section on your website to ask question if we get stuck. I am currently following along and completed "Starting Our Studio 5000 & FactoryTalk View Files" section :) should we email you our questions? thanks!
@ShaneWelcher3 жыл бұрын
Sure, just shoot me an email
@oliesting49212 жыл бұрын
@@ShaneWelcher what is your email? I have a question regarding RecipePro+. I am getting an error when trying to create ‘Generic’ recipe. The error is "Unable to create recipe file 'Generic' at HMI Server". Please let me know how to move forward as future lectures depend on this RecipePro+. Thank you!
@donniechen87188 ай бұрын
Shane, Which manual has the info of class instance, attributes for PF755?
@ShaneWelcher8 ай бұрын
Knowledgebase
@joseantonioalvarez50257 ай бұрын
@@ShaneWelcher 36 / 5.000 I need help where can I contact you?
@SafeAndEffectiveTheySaid11 ай бұрын
Thank you Sir! We are actually having so much trouble trying to correlate the drive so many bugs
@ShaneWelcher11 ай бұрын
Glad this helped
@diarmuidoconnor20019 ай бұрын
Does anyone know how I can use this with other parameters? I presume I must use the parameters Hex code but cannot find them anywhere. Its for my Final year project of my degree. The current is a huge help but I also need voltage and power at minimum
@ShaneWelcher7 ай бұрын
You need to create a datalink for that
@sophialucena62013 жыл бұрын
🙌🙌🙌🙌🙌
@ShaneWelcher3 жыл бұрын
Glad to help
@trevorrichard47102 жыл бұрын
This didn’t work for me. It’s saying the class or instance isn’t supported
@ShaneWelcher2 жыл бұрын
Please watch & follow exactly what I teach, it shows how it works through the video
@vladimirelkin16862 жыл бұрын
Shane, your footage is great, but how did you select Class, Instance, and Attribute in the messaging setup? Thanks
@ShaneWelcher2 жыл бұрын
From the drive & from the message instructions. Depends on the drive. I often look at Rockwell Automation's tech notes to verify the proper attributes & classes. The drive manual would be one point of reference