SMA inverter fault VAC BFR, what is this?

  Рет қаралды 5,293

Andy Reynolds

Andy Reynolds

Күн бұрын

Пікірлер: 28
@ianhelsbyservices
@ianhelsbyservices Жыл бұрын
Glad to see it working. We all need to generate our little bit, especially when the import cost doubles in April. Worth pointing out volt drop across long leads too. I swapped a 50m 1.5mm2 extension cord for a 2.5mm2 as the smaller reel lost 12% in voltage.
@TheInfoworks
@TheInfoworks Жыл бұрын
Ian, volt drop is a killer with all of these systems. I am going to move some inverters closer to their panels to reduce this, cheers
@kennyward4674
@kennyward4674 Жыл бұрын
I got a bit of chuckle from that one😀 Glad it was a simple fix and at least you know what the code is now.
@TheInfoworks
@TheInfoworks Жыл бұрын
Kenny, yes a bit of a DOH! moment, cheers
@g7mks383
@g7mks383 Жыл бұрын
Hi Andy, Not sure about that socket outdoors without protection. Could get corrosion on the plug pins and also the fuse holder. Thanks for the video.
@TheInfoworks
@TheInfoworks Жыл бұрын
Hi, oh yes, exactly, this is a temporary set up, cheers
@noakeswalker
@noakeswalker Жыл бұрын
SMA inverter error codes VAC-Bfr and VAC-Srr seem to be internal codes for 'grid voltage too low' and 'grid voltage too high' respectively. Grid frequency out of range error codes are FAC-Bfr and FAC-Srr also. What 'Bfr' and 'Ssr' are short for, I can't work out. Just looked this up online, and am passing it on as I find it. If you don't have a label printer Andy, and I _really_ recommend them, you could do worse than use masking tape wrapped around and a permanent pen marker to label your cables outside and in the batt shed. Cheers, Dave
@TheInfoworks
@TheInfoworks Жыл бұрын
Dave, so VAC BFR in this case refers to AC low. Normally I colour code wires and that extra white mains lead was from testing a Solis, then forgetting it was there, cheers
@mattcotton4413
@mattcotton4413 Жыл бұрын
Who doesn't like a quick win! 😎
@TheInfoworks
@TheInfoworks Жыл бұрын
Matt, especially when it's caused by a simple no harm mistake, cheers
@mouldyboats
@mouldyboats Ай бұрын
Those caps are hating life. Looks like your next inverter problem. Recap with Nichicon's and get it out of exposure.
@bootsowen
@bootsowen Жыл бұрын
I wondered about putting a multimeter across ac. But a true rms meter would be necessary.
@TheInfoworks
@TheInfoworks Жыл бұрын
Owen, as you see it's fine unless you need to be very accurate. It let me know there's mains power there, cheers
@sim6699
@sim6699 Жыл бұрын
Are any grid tie inverters really reliable or come with a 10 year guarantee?
@TheInfoworks
@TheInfoworks Жыл бұрын
Well this one may be 15 years old. The Solis had a 10 year guarantee. it all depends on the quality of the installation, cheers
@christianlarsson6065
@christianlarsson6065 Жыл бұрын
Help, sorry bad inglish. Omniksol 2k tl Isolation fault , fault in inverter, where do i start looking? Relays is new.It is possible find schema?
@TheInfoworks
@TheInfoworks Жыл бұрын
are you sure the fault is in the inverter, many times it is in the panel wiring. make sure your DC wires are strapped up and not touching earth, cheers
@christianlarsson6065
@christianlarsson6065 Жыл бұрын
@@TheInfoworks yes absolutely sure, also tried 150 vcd from battery
@TheInfoworks
@TheInfoworks Жыл бұрын
@@christianlarsson6065 Difficult to define, maybe start checking the capacitors. Otherwise replace the unit with a second hand solar inverter, cheers
@giovanniablett1628
@giovanniablett1628 Жыл бұрын
Thank you
@TheInfoworks
@TheInfoworks Жыл бұрын
No worries, I hope you have subscribed, cheers
@neilobusk
@neilobusk Жыл бұрын
I know nothing about solar.....apart from using the sun..lol learning... N x
@TheInfoworks
@TheInfoworks Жыл бұрын
Neil, time to gather some, cheers
@Rami-z8f
@Rami-z8f Жыл бұрын
Help inverter won’t turn on
@TheInfoworks
@TheInfoworks Жыл бұрын
do you have AC and DC power at your inverter?
@cherrabimohammed7342
@cherrabimohammed7342 6 ай бұрын
@@TheInfoworks hi, i meet the same issue it will not run... i have a 480vdc and 230vac but it wil not run it's a sb3800
@TheInfoworks
@TheInfoworks 6 ай бұрын
@@cherrabimohammed7342 is the 230v AC getting on to the board? cheers
@cherrabimohammed7342
@cherrabimohammed7342 6 ай бұрын
​@@TheInfoworks hi, it run wel now... The mistake that i did was to run First the DC then the AC and normaly you need to start the inverter First then activate the DC switch
SMA Solar grid inverter SB1700
15:39
Andy Reynolds
Рет қаралды 4,6 М.
Electrical Wiring for a SMA Sunny Boy 7.0 Grid Tie Inverter
8:50
Grumpy Miner
Рет қаралды 3,8 М.
НИКИТА ПОДСТАВИЛ ДЖОНИ 😡
01:00
HOOOTDOGS
Рет қаралды 2,9 МЛН
SMA Sunny Boy Isolation Resistance Error 35 Message
5:18
Gold Coast Solar Power Solutions
Рет қаралды 21 М.
Stunningly simple solar hot water system 🔥🌞
16:11
highflyrod
Рет қаралды 6 М.
Installation of Sunny Boy US-41 Inverter
9:07
SMA Solar Technology
Рет қаралды 33 М.
AMP HOURS EXPLAINED (amp hours vs watt hours)
10:59
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 982 М.
Sunny Boy Solar Inverter Removal
5:50
EEVblog2
Рет қаралды 11 М.
SMA HF solar grid inverter, features and test.
12:42
Andy Reynolds
Рет қаралды 2,4 М.