PowerFlex 525 VFD Setup - Programming Parameters Wiring RSLogix Studio 5000 EtherNet IP Start Stop

  Рет қаралды 103,007

SolisPLC

SolisPLC

Күн бұрын

Пікірлер: 78
@juliollontop4812
@juliollontop4812 3 жыл бұрын
I was an EE for 18 years, now a maintenance supervisor. Yor video is straight forward and informative. 5 stars
@SolisPLC
@SolisPLC 3 жыл бұрын
Thanks!
@automationpanthers2794
@automationpanthers2794 12 сағат бұрын
Great Explaination.
@davidpalmer963
@davidpalmer963 2 жыл бұрын
Absolutely fantastic VIDEO !!!!!!!!!!!!! Vlad, you cover every detail..as usual.
@DunwoodyRobotics
@DunwoodyRobotics 3 жыл бұрын
Awesome Video! You just saved me a ton of time hunting and pecking in the user manual... Thank you!
@RahulMishra-mw4ml
@RahulMishra-mw4ml 2 жыл бұрын
absolutely brilliant bro. you have made it so simple to understand. 👍🏻👍🏻👍🏻
@isaacpayne4589
@isaacpayne4589 4 жыл бұрын
I love your Videos Solis! Thank you for always sharing knowledge
@SolisPLC
@SolisPLC 3 жыл бұрын
You're welcome! Glad you're finding them useful.
@Jrjulio95
@Jrjulio95 4 жыл бұрын
Really nice and helpful video
@shreedharvyas7666
@shreedharvyas7666 2 жыл бұрын
Fantastic!
@PINOYTECHMARLON
@PINOYTECHMARLON 4 жыл бұрын
Thanks sir for the very useful video
@kevin00861
@kevin00861 2 жыл бұрын
Thanks a lot 🙏
@suriyat8773
@suriyat8773 8 ай бұрын
Thank you
@KillerSmells
@KillerSmells 2 жыл бұрын
Do you have a video where you use a 4-20mA output on the PLC to vary the speed of a VFD?
@ChristianMealey-1
@ChristianMealey-1 8 ай бұрын
Jumper comment came in clutch
@tusharsood2443
@tusharsood2443 6 ай бұрын
amazing
@bryanfrancisco-t7x
@bryanfrancisco-t7x 6 ай бұрын
What is DSi port beside Ethernet ip?
@charlesdoty776
@charlesdoty776 3 жыл бұрын
new to the channel,but learning alot as im very new to the automation world.enjoyed the video very informative,wanted to ask do you have any video's on the siemens g120x vfd
@jasonpick3670
@jasonpick3670 3 жыл бұрын
This might help with school I'm in my last semester for Automated Manufacturing Systems Technology
@alangutierrez1447
@alangutierrez1447 Жыл бұрын
Can you do a video explaining a path splicing failed to splice the path pf525
@АндрейСидоров-ц3ж
@АндрейСидоров-ц3ж 4 жыл бұрын
Thank you for your video. But why you didn't show how to add a converter?
@SolisPLC
@SolisPLC 4 жыл бұрын
What do you mean to add a converter? The wiring of the drive?
@АндрейСидоров-ц3ж
@АндрейСидоров-ц3ж 4 жыл бұрын
@@SolisPLC no in RSLogix 5000.
@SolisPLC
@SolisPLC 4 жыл бұрын
@@АндрейСидоров-ц3ж Sorry about that. The video was already long, so I left out certain parts. I'll try to step through the process in a separate video.
@juanalamilla7566
@juanalamilla7566 7 ай бұрын
How to change the ovid amps on a power flex to its macimu.
@suriyat8773
@suriyat8773 8 ай бұрын
Thank
@YunWang-qk7up
@YunWang-qk7up Жыл бұрын
good
@sunilsisodia51
@sunilsisodia51 Жыл бұрын
May I know in about Kinetix servo drive how to measure voltage, Ampere from Ethearnet communicate and get see in Hmi
@agripp36
@agripp36 Жыл бұрын
Unclear about what you did at 14:30. The PF1 output. How did that tag get there? How did you know to use that one? Is PF1 a start or stop? Thanks
@ravindradesai5007
@ravindradesai5007 3 жыл бұрын
Hello sir nice video can you please tell me the (PLC 5, RS Logic) VFD control via DH + Communication
@gregarkwright3960
@gregarkwright3960 3 жыл бұрын
In the very end of the video, the green button is pressed. The plc receives this input. Then, the ethernet wire energizes the VFD? Is that how it works?
@SolisPLC
@SolisPLC 3 жыл бұрын
That's correct Greg.
@gregarkwright3960
@gregarkwright3960 3 жыл бұрын
@@SolisPLC Thanks for your assistance. I still don't understand completely, but I need to keep on studying. I need to continue and one day I will get it
@stephengibbon2141
@stephengibbon2141 2 жыл бұрын
This logic has created a race condition. If the RPI times out between your start and stop branch it means a packet will be sent to the drive asking to start and stop together. The next packet should just be a start but the drive is already locked up until the start is cycled. Nice video though!
@BieuHoangDinh
@BieuHoangDinh 4 жыл бұрын
Thanks Sir. Great video. I have Problem. I want to config IP address for PowerFlex 523 (25A-D017N114~~~7.5kW).. But on keypad i don't see show Parameter (C128/C129,C130,C131,C132/C133,C134,C135,C136). I had setting C169=1 (Network opt). Please help me. Many thanks.
@abdullrahimjajeh8572
@abdullrahimjajeh8572 2 жыл бұрын
Does the VFD need to be tuned like the servos?
@stevekesler5928
@stevekesler5928 4 жыл бұрын
Great video! - What make/model motor are you using in the video?
@SolisPLC
@SolisPLC 4 жыл бұрын
Hey Steve, it's a "25B-V2P5N104 " Powerflex.
@abdullrahimjajeh8572
@abdullrahimjajeh8572 2 жыл бұрын
@@SolisPLC does the drive needs its own AB motor?
@darryladams5644
@darryladams5644 6 ай бұрын
Why did you hard wire? I did mine the same way without hard wiring push buttons and it still starts and stops the vfd and motor. Are you just showing us two different ways to accomplish the same results? Is there a reason why you did it this way?
@SolisPLC
@SolisPLC 6 ай бұрын
Yes, just to showcase the specific start/stop IO. In some facilities they still use those, but it's absolutely unnecessary if you're doing it over EtherNet in my opinion.
@darryladams5644
@darryladams5644 6 ай бұрын
Ahh makes perfect sense. Thank you for explaining!@@SolisPLC
@DerekPalisoc-lg6gd
@DerekPalisoc-lg6gd Жыл бұрын
could you start and stop the VFD via PLC and not having external start and stop button? appreciate your response. thanks
@SolisPLC
@SolisPLC Жыл бұрын
Yes, you can set the drive parameters so that it only starts and stops via PLC logic.
@nukeelda
@nukeelda 3 жыл бұрын
What kind of trainer do you use and did you have to buy studio 5000 ? Great videos keep it up !!!!
@SolisPLC
@SolisPLC 3 жыл бұрын
I built my own trainer; it's mostly an arrangement of components I purchased separately. I have a license through the projects I work on. It is fairly expensive.
@nukeelda
@nukeelda 3 жыл бұрын
@@SolisPLC yeah I know it is expensive .I think you can use workbench instead 5000
@KamalSingh-dd4ou
@KamalSingh-dd4ou 4 жыл бұрын
How many vfds can be added? Enthernet?
@n__r6224
@n__r6224 4 жыл бұрын
Hello Thanks for the Rslogix 500 software video.. Is there any link where i can get rslogix 5000 software and emulator for study purposes waiting for your reply
@SolisPLC
@SolisPLC 4 жыл бұрын
Not that I know of.
@nirmal_tom1897
@nirmal_tom1897 4 жыл бұрын
@@SolisPLC any cracked version
@SolisPLC
@SolisPLC 4 жыл бұрын
@@nirmal_tom1897 I don't use cracked versions, but I'm sure that you can find links through forums and Facebook groups. Sorry.
@dwaynes965
@dwaynes965 4 жыл бұрын
ab website. I use the RSLogix Micro starter lite and works great for me.
@raulh802
@raulh802 4 жыл бұрын
Hello great info , this setup is on Studio 5000 ? Can someone run 525 via rs logix 5000 using messaging? If so do you have a video on that ?
@SolisPLC
@SolisPLC 4 жыл бұрын
Yes, that's definitely possible. At this time, I don't have a video on that, but I'll plan to add it to my list.
@gustavotorresberra5178
@gustavotorresberra5178 4 жыл бұрын
Good evening Vlad, what SPECIFIC model is that PowerFlex 525 VFD?
@SolisPLC
@SolisPLC 4 жыл бұрын
25B-V2P5N104
@gregarkwright3960
@gregarkwright3960 3 жыл бұрын
There is a coil inside the VFD correct? And when it gets energized it closes the contacts which sends power out to the motor. So, is the ethernet wire energizing the coil? Is it power of Ethernet type wire?
@SolisPLC
@SolisPLC 3 жыл бұрын
Hi Greg, not exactly. The EtherNet commands go to a board on the drive. This board receives the signal and will use a chip that is on the board to toggle the coil. There is no power over ethernet and it's not the direct signal over that wire that is switching the drive.
@toddpreisler8963
@toddpreisler8963 4 жыл бұрын
I have seen that I've had to branch a Start and Run Forward together in order to get the drive the run. How did it do with merely the start?
@SolisPLC
@SolisPLC 4 жыл бұрын
That's a good point. I looked through my previous code within the program and it included an FWD/REV flip-flop for that particular drive. In other words, it was already enabled on FWD elsewhere. Sorry about the confusion.
@RahulGupta-yl7gf
@RahulGupta-yl7gf 3 жыл бұрын
How can we change the standard function of a VFD terminal using parameters only. Eg, making a moter to rotate in reverse direction by giving the command to the forward terminal (02). I'm using powerflex 525 VFD. Ps interchange of wire connection is not the option it has to be done by changing some parameters only. Please help!
@megavergatario1
@megavergatario1 4 жыл бұрын
what control logix version I need to make this what if I got an older version ?
@SolisPLC
@SolisPLC 4 жыл бұрын
Hey Erik, to set it up this way, you need Studio 5000 v 21+. A similar setup is possible on RSLogix 5000, but the layout would be slightly different.
@jcollier3212
@jcollier3212 4 жыл бұрын
How do you reverse a insert request to make the logic take the object automatically
@SolisPLC
@SolisPLC 4 жыл бұрын
I'm not sure I fully understand your question. How to reverse the motor? Take the object automatically?
@jcollier3212
@jcollier3212 4 жыл бұрын
SolisPLC take the skid automatically
@yi9164
@yi9164 4 жыл бұрын
Hi there, would you be able to do a tutorial on setting up PID (exlclusive and trim) tutorial on your Udemy powerflex course please?
@SolisPLC
@SolisPLC 4 жыл бұрын
Just a general PID or one for the drive? What would be the feedback loop for the PID? I'd probably need an encoder for that. I may consider doing a video on that in the future.
@yi9164
@yi9164 4 жыл бұрын
@@SolisPLC pid for the drive would be great. would you be able to demonstrate both the exclusive control and trim control and the difference between using general pid or drive etc....? cheers
@joew4202
@joew4202 3 жыл бұрын
Vlad, how do I change speed of the drive over Ethernet? Somehow the controls engineer o work with gets into the parameter on the drive and increases/decreases speed. When I look at parameters the output frequency is always grayed out and I can’t change it
@SolisPLC
@SolisPLC 3 жыл бұрын
The parameter should be the right approach. I suspect that it's either nested into an AOI or it's being aliased elsewhere. Can you send me the program or a few screenshot to v.romanov@solispl.com? I'll try to see what's wrong in your specific case.
@stephengibbon2141
@stephengibbon2141 2 жыл бұрын
You need to look at the command frequency. The output frequency is what the drive is actually running at.
@joew4202
@joew4202 2 жыл бұрын
@@stephengibbon2141 I was trying to change the speed in the controller tags. I needed to change the speed in the actual logic for it to work
@RahulGupta-yl7gf
@RahulGupta-yl7gf 3 жыл бұрын
How can we change the standard function of a VFD terminal using parameters only. Eg, making a moter to rotate in reverse direction by giving the command to the forward terminal (02). I'm using powerflex 525 VFD. Ps interchange of wire connection is not the option it has to be done by changing some parameters only. Please help!
@amarnath2740
@amarnath2740 3 жыл бұрын
F 00 4 error
@PLC-79
@PLC-79 8 күн бұрын
may be I'm wrong, stop should be NO
@rufushughes5602
@rufushughes5602 Жыл бұрын
Why do you have to push buttons so fast or do your presentation so fast in general woo!.it is difficult to follow
Players vs Corner Flags 🤯
00:28
LE FOOT EN VIDÉO
Рет қаралды 81 МЛН
规则,在门里生存,出来~死亡
00:33
落魄的王子
Рет қаралды 27 МЛН
Офицер, я всё объясню
01:00
История одного вокалиста
Рет қаралды 5 МЛН
Programming a VFD from the Keypad
14:51
AccessToPower
Рет қаралды 38 М.
How to Wire a PLC Control Panel Like a Pro
9:06
Bee Automation
Рет қаралды 113 М.
Adding a Powerflex 525 to RSlogix 5000 over ethernet
16:56
PLC Automation Training
Рет қаралды 153 М.