Excellent demonstration Sparky. You sold me I am buying it. I been dragging my feet due to the cost. But you showed me for the cost and the value. It is a tool I need. Thank you.
@joedillon1594 жыл бұрын
Sparkman is the best! Always teaching us new and better ways to be safe! I’ve learned so much from him. Love Sparkman!
@SparkyChannel4 жыл бұрын
Thanks so much Joe!
@Esspppiia2 жыл бұрын
I just bought this over the weekend and finally had the chance to test it out today. I really don't like the stiffness of the extension cord nor the direction of the adapter plug, with the ground prong in the upright position.
@Marcel_Germann4 жыл бұрын
The frequency also got a tolerance. Here in Europe it is 50 Hz, the deviation is mostly below +/- 0.2 Hz. You can actually see how good the grid stability is by watching the frequency. If the demand in the grid is too high in comparison to the power supplied by the power plants, the frequency will drop. In airplanes the frequency of the on-board power supply is higher, mostly round about 400 Hz, so they can use smaller transformers. But the disadvantage is: You can't transmit the electricity over long distances with such a high frequency. Here in Germany the trains are supplied with 15,000 VAC with 16.7 Hz (one third of the 50 Hz) from overhead line wires. If the frequency is wrong you sometimes will get such effects like a clock going wrong. For example clock radios or the clock which is integrated into an oven and uses mains frequency to indicate the time (synchronous clock).The deviation on a synchronous clock in Europe was only +/- 10 seconds, and that over years. But in 2018 that changed, we got the biggest synchronous power grid of the world. And in 2018 the clocks had a deviation of -359 seconds! And the cause was: There was a dispute between Serbia and the Kosovo about controlling power range, the Kosovo didn't produce enough electricity, so the frequency dropped in Europe. The thing is, here in Germany the only visible result was such clocks ran slow and indicated the wrong time. Only the radio controlled clocks and the mobile phones still had the correct time. And the battery operated ones of course. The voltage drop is also an indicator if the wiring is dimensioned too small for an appliance with a high demand. If the wires are one size larger than necessary, the voltage drop will be much lower. The drop is caused by the wires in the wall. They are heating up on a high load and changing their resistance and that causes the drop. So you're paying for electrical energy that is not used for your appliance, you heat up the house and the environment arround it. You can calculate the voltage drop if you know the size of the wires, the current and the voltage. I got a slide rule were you can adjust the wire size, the current, cable length and get the prospected voltage drop as a result. And important is also the conductor material, on copper it's different than it is on aluminium. The GFCI tripping time is in my opinion very high when I compare this to the GFCI devices we have over here, it's still within the limits which are permitted, but on the high side. The range is up to 200ms, but in most cases you'll only get between 20 and 30ms tripping time. The GFCI we use here are mostly fitted into the panel to protect a whole circuit, integrated into the outlet is very expensive here. An outlet with an integrated GFCI device is round about 150 Euros (166 USD), but the ones you install into the panel are round about 25 to 30 Euros (28 to 33 USD), that are only the costs for the material!
@Wowzersdude-k5c2 жыл бұрын
Here we have different classes of GFCI's. Class A, B, C, D, E. Class A is the standard residential receptacle type as seen in this video and they must trip at 5mA. Class B is the same but with a higher trip threshold (20mA). Class C is where you get into industrial use (300 V and higher). Class D is for 600V or higher. Class E devices have not been invented yet. All of them (except for class A) have a trip threshold of 20mA. (Class A trips at 5mA). The reason the various trip thresholds exist is because 5mA is too low for industrial applications (it would trip all the time). And the reason the 5mA devices have a longer trip time is because they trip at such a low threshold (5mA). They are therefore allowed a slightly longer time to trip. I suspect 200ms as demonstrated in this video is probably about average. GFCI's with a trip threshold of 20mA are supposed to trip at around 25ms I believe. (UL will test all of this before the product is certified for sale. UL writes the standards, in fact). Also, we have tracked statistics here in America since the introduction of GFCI's in 1971. Electrocutions have decreased by 80% overall and electrocutions from consumer products have decreased 95%. Part of this is probably because products themselves are better engineered now, and part of it is because of GFCI's being more widespread.
@Marcel_Germann2 жыл бұрын
@@Wowzersdude-k5c Interesting, we got different types too. But the classification is different. Type AC: Can only detect AC fault currents, Banned here in Germany for new installation in 1987. In several European countries still permitted. The UK banned them for new installation this year. A DC fault current of 6mA or more will blind the RCD, saturating it's measuring transformer so it won't trip. Even if the AC fault current is well above the rated tripping current. Type A: Can detect AC faults and in addition to that unsmoothed DC directly from a rectifier. Is necessary since we have more and more devices with a switch-mode power supply like phone chargers and such stuff. Standard type for domestic dwellings here in Germany since the type AC ban in 1987. Type F: Like type A + AC with a frequency up to 1kHz. Type B: Like F + smoothed DC, usually for EV chargers if they don't have a DC protection integrated. Type B+: Like B and can detect AC fault currents up to a frequency of 20kHz.
@StormyITO3 ай бұрын
Just as a reminder a minimum voltage drop is not code-mandated, NFPA-70 suggests it as a good idea and not a requirement.
@McmM-ck1op4 жыл бұрын
Just want to say thanks Bill that is a very good meter I just purchased one and it does everything as you described keep the good work up..👍
@samgalindo86623 жыл бұрын
Thanks Bill for all the educational videos you put out for your followers! If possible could you show a video on using the 61-176 Isolated ground adapter and the 61-175 ground continuity adapter please? I purchased the 61-165 Ideal Circuit Analyzer and am learning how to use it. Regards Sam
@brodymoore20083 жыл бұрын
confused why .16 ohms is high. based on 50' run, the calculation that's what it should be. my question is why is the neutral impedance so low if its 50' run.
@alexrodriguez31063 жыл бұрын
Thanks a lot for your video, this gives me an idea what I am going to get, how to use it, etc. I did not see an explanation how to test the AFCI part, is this meter capable to do that? 1 UPDATE: I got the meter, I had trouble testing the G impedance using the Squared D GFCI/AGCI breaker, well I came back to watch your video, and you explained that the GFCI must be bypassed to test the G impedance. Still, when I use ASCC2 it triggers the Square D breaker. I love it, this is what I called "KZbin University." 2 UPDATE: I just did a test on 250F 14 AWG roll of romex wire, here are the results: H = 0.71Ω, N = 0.66Ω, G = 0.66Ω, the H is higher, I attribute this to the breaker. Nothing was in between this roll of wire. One end had the outlet to connect the meter, the other end the breaker. When I checked one wire with the Keysight DMM U1273AX I get exactly 0.66Ω. All three wires report the same Ohms = 0.66. This cannot get any better.
@stanmcnabb8022 жыл бұрын
Thank you for the demonstration! Are there any videos that show how to use the Ideal alligator clip accessory for the sure test circuit analyzer?
@thecapitalalliance4 жыл бұрын
Very helpful, thank you. I just got one prior to seeing the video, and found the information most helpful.
@SparkyChannel4 жыл бұрын
Glad it was helpful! Thanks!
@haiselie88534 жыл бұрын
Amazing video :) that seems helpful, can you do a video about what to do to be an electrician? I know you have to go to a trade school or union but I don't know , I would love a video with some tips for young people like me who wanna start this trade.
@SparkyChannel4 жыл бұрын
One way is to just go to your local electrical union hall.
@DoctorSparta4 жыл бұрын
My suggestion is to find a school in your area who has an apprenticeship program. When you are just starting out in the profession, there is an education requirement that goes along side your apprenticeship. In the USA, its 600 classroom hours, often split up over 4 separate years. If you are serious about it, enroll your self as a first year apprentice, and ask your classmates/instructors if they know anyone hiring. Already starting your education will give you a good foot in the door, and shows some initiative. My company just hired a guy for that exact reason. Hes an early 20s fellow who has been working in the fishing industry while taking electrical classes in the evenings. He asked around, and once his name got to us, it was a quick decision to give him a shot. My schooling was under $1000 a year, so even if it doesn’t work out, its not too heavy of an investment.
@mostlikelywedoitservices69263 жыл бұрын
So is the meter creating a load on the circuit to be able to give you those numbers?
@whitetiger86524 жыл бұрын
Definitely a great tool to have, Thanks Sparky
@SparkyChannel4 жыл бұрын
It sure is, thanks!
@antonioterrell3544 жыл бұрын
Same here, ... Wonderful instrument, thanks for the review Sparky ... And wish I could afford one which I see is currently marked down over a $100 right now on sale from Amazon for about $261. But with my reduced finances under the pandemic, still can't do it. 😞 Particularly impressed with this analyzer's ability to detect "false" or bootleg grounds this way and certainly could have used something like this when the electricians rewired my home back in '05 and did this sometimes to fool the standard 3-light testers used by me and the inspectors. Especially considering the total cost of the re-wire job (upgrading from archaic "knob & tube" wiring) was $6500 at the time 😠 ...
@educationpower18232 жыл бұрын
Where do you come up with the .003 Table 8 or 9 in chapter 9 nec gives different values??
@ccadama4 жыл бұрын
@Sparky Channel. Thanks for another great review. Question. Have you experienced any problem with the Ideal Sure Test Circuit Analyzer tripping AFCIs when plugged into a circuit protected with one? Hope you and your family stay safe and well.
@SparkyChannel4 жыл бұрын
Only when testing grounds for Z. You have to bypass the GFCI/AFCI to do that test. Thanks so much, you too!
@ED-se2tz2 жыл бұрын
Hello Sparky, with the GFCI test mode, your video showed it tripped at 118 ms. What would be the maximum allowable trip time for a GFCI before it needed to be replaced?
@emmanuelny334 жыл бұрын
Awesome video as always keep it up Bill love your videos.
@SparkyChannel4 жыл бұрын
Thanks so much!
@mountshasta20023 жыл бұрын
How does it calculate the voltage drop? Do you have to apply a load for it to read or does it do it without?
@annruelhomeinspections5163 жыл бұрын
I have have a 61-165 I bought on ebay a few years ago where can I buy another one? the 165 has the AFCI button too
@charletonzimmerman42053 жыл бұрын
Great, when they coming out with a AFCI, Recpt. TESTER???
@rockcrusher70003 жыл бұрын
i enjoy the info you provide , regarding testers , have you tried the Klein rt310 , reason i asked is . i installed several Leviton afci outlets and the inspector failed my electrical because the meter wouldn't trip afci , manufacture said only the integral test button is required , your thoughts thnx
@IrrationalBstrd3 жыл бұрын
There is nothing in the instructions of those breakers that says to use any type of meter to test them, and that it should be done with the integral test button. If it trips and then resets via the integral test button, then they should be considered good according to it's UL listing and instructions.
@chriscarter34314 жыл бұрын
What is high when checking the impedance on the neutral? You showed .06
@sedona12345664 жыл бұрын
Perhaps the hot resistance difference is created at the breaker.
@Cymaphore Жыл бұрын
Thanks for the demonstration - very interesting! Overall I think it seems less suited than a normal-sized multi functional installation tester, since it can't really be used in panels and on bare terminals due to a lack of probes as it seems, and the limited fuse ratings that can be entered. It also lacks insulation testing, as far as I can tell. Also the numbers it outputs in your demo look more or less like rough estimations to me. So I think it's not really a challenger for the Fluke 1662 (or another of the 16xx-Models depending on your needs and what kinds of RCDs you need to test on a regular basis). Beha-Amprobe ProInstall 100 and Megger MFT1800 are fine testers as well. And they can all test Zs without tripping the RCD (Idn 0.03A at least for most of them). I could imagine that the lack of accuracy on this ideal circuit analyzer might make it difficult to clearly identify certain faults like loose terminals, damaged wires or hidden surprises and such. Also they should really consider adding insulation resistance testing I guess, would make sense since it's also needed for final testing after installation. But I have to admit, it's compact, that is quite charming compared to the bricks one has to carry arround otherwise for that purpose!
@Sparky-ww5re2 жыл бұрын
This is a very useful tool for any electrician or home inspector despite the 300 dollar give or take price tag, but especially for flipper homes. Bootleg grounds are especially common in flippers and many inspectors will not catch that, because they rely on your typical three light tester, although there are some signs to look for here that might indicate a Bootleg ground (jumper between neutral and ground) : 1) The home was built before the mid 1960s. 2) the presence of three prong receptacles that test as correct wiring, in random places, some are three slot, others are two slot. 3) the presence of old style, fabric braided wiring. 4) the presence of a fuse panel, typically 60 amps.
@paultanner20073 жыл бұрын
Thanks sparky! Great info
@Ariccio123 Жыл бұрын
I'm actually curious how this thing does a 15 amp load test without getting glowing red hot
@cavscout888 Жыл бұрын
Probably just puts some load, like 1a, and then does the math for you. Mainly a math problem once you get some level of resistance. I THINK.
@bobbymorino53292 жыл бұрын
Gotta get me one. I have a hot and ground reverse I can't find.
@SparkyChannel2 жыл бұрын
Sounds good!
@arthurhowland68214 жыл бұрын
Thanks for posting....Art
@SparkyChannel4 жыл бұрын
No problem, it's a great and very useful tester. Thanks!
@johnwithee1091 Жыл бұрын
can you do 240 volt as well?
@2kkanish11 ай бұрын
I spoke to the engineer at Ideal and Klein Tools. There is no such tool. I assume you work in the pool/hot tub industry.
@dwaynes598311 ай бұрын
If your checking lines in the home I think that would fall under 220. Two 110 lines coming into home and your checking anyway. For a item that is 220 multi meter should work well. Each leg to ground.
@jlor76752 жыл бұрын
What am I missing? I read .16 Ohm not 1.6 OHMs.
@drewbush65353 жыл бұрын
ordered mine today does alot.. very useful. shared n....ect
@traviselectricalservices4532 Жыл бұрын
I see a lot of voltage drop when the oulets are old with loose or bad connections
@echeverriaemilio4 ай бұрын
Thank you!!
@luislazogue80892 жыл бұрын
Hi Bill can you explain me what true RMS means?
@philklassner2815 Жыл бұрын
The square root of the Mean of the instantaneous values squared.
@truthseeker13283 жыл бұрын
7.4 mA? A class A GFCI is designed to trip at 5 mA with an acceptable deviation of +/- 1 mA (i.e. 4 to 6 mA) according to UL943. So a GFCI that trips open at anything greater than 6 mA should be considered faulty and replaced. The GFCI is nothing more than an electro-mechanical device with a toroidal coil AKA "current transformer" and a shunt trip circuit which can degrade due to age, exposure to heat, humidity and other factors. Other than than this, a good video demonstrating the Ideal 61-164. Still debating if I should pick up the Ideal 61-164 or the Amprobe INSP-3.
@drewbush65353 жыл бұрын
.16 ohms impedance on hot wire, could it be reading through something thats pugged in?
@alexrodriguez31063 жыл бұрын
How about the breaker?
@scottparrish24222 жыл бұрын
Thank you for sharing your knowledge
@SparkyChannel2 жыл бұрын
My pleasure!
@ghostpepper24843 жыл бұрын
Great video, thank you
@steven76503 жыл бұрын
Impedance is the sum of resistance plus reactance
@ROBERTELECTRIC14 жыл бұрын
Thank you . very good video. very helpfull.
@jaison7828 Жыл бұрын
Question… when I plug the suretest it turns on then off right away.. what could this mean?
@SparkyChannel Жыл бұрын
Battery dead?
@nathaniel52084 жыл бұрын
Can you do a video on this panel mapper MMJ-MIT747
@nupurtripathi15372 жыл бұрын
Chúc gia đình luôn hạnh phúc.... Được nhiều view hơn nhé !!!! 殺
@mr.g9373 жыл бұрын
Why doesn't it check hot-ground voltage? Isn't that useful?
@mohammaddirani45153 жыл бұрын
Thank you
@SparkyChannel3 жыл бұрын
You're welcome!
@johngallati81643 жыл бұрын
GREAT TOOL GREAT VIDEO
@SparkyChannel3 жыл бұрын
Glad you liked it!
@johngallati81643 жыл бұрын
@@SparkyChannel Great explanation
@victormartiny7599Ай бұрын
Aweso0me Thanx!
@SparkyChannel27 күн бұрын
You're welcome!
@bkburg46113 жыл бұрын
Hi thanks for this review. Can this analyze the wiring of a de-energized circuit?
@ThankMani3 жыл бұрын
I believe the analyzer needs a powered circuit to turn on. It has no power source (battery) of its own
@SuperVstech4 жыл бұрын
Mind has afci test function as well...
@SparkyChannel4 жыл бұрын
Excellent!
@La2venida4 жыл бұрын
How will this be used to find in a circuit in where there are some of outlets that are not working and others are .
@farmerdave79654 жыл бұрын
Electricians always get mad at me when I tell them the average voltage is zero.
@SparkyChannel4 жыл бұрын
LOL! Well that's what it should be!
@MrTooTechnical4 жыл бұрын
i want one.
@SparkyChannel4 жыл бұрын
I hear that! Thanks Dave!
@spyderx924 жыл бұрын
They need one with afci
@SparkyChannel4 жыл бұрын
Yes, that would be good.
@NOLAWAGAINSTIT4 жыл бұрын
they had one, then they discontinued, don't know why.
@NOLAWAGAINSTIT4 жыл бұрын
www.tequipment.net/Ideal61-165.asp
@SuperVstech4 жыл бұрын
@@NOLAWAGAINSTIT mine is the 165, and I bet the afci was discontinued because of all the updates to the afci standard.