@pathikpatel010
@pathikpatel010 3 жыл бұрын
You are absolutely right Paji. Mere Daikin ke ac K installation k time Technician ne Proper 40-45 minutes ke liye Vaccume kiya tha Vaccume pump motor se Phir usne gauge Pressure me check karke required pressure maintain karkemere ac system Ko On kiya. This process takes time that's why some technician avoiding this Important thing. Ac system needs proper Vaccume to give its100% Performance.👍
@babitagarg1970
@babitagarg1970 3 жыл бұрын
Mere yhn bi daikan ac laga hai 6 months back.. muje yaad ni ki vacuum hua tha ya nhi? Kya krna chhaiye kuki warranty mein hai??😶😶 working theek krra hai.
@pathikpatel010
@pathikpatel010 3 жыл бұрын
@@babitagarg1970 abhi koi fayda nahi hai Ek bar System on ho jata hai Bina Vaccume kiye matlab Pipes Jo installation ke vakt joint ki unme Mojid air air moisture Puri system me fhel gaya hoga. Lekin jabh bhi kich Reinstall kare to Vaccume karvana bhulyega nahi.👍
@pathikpatel010
@pathikpatel010 3 жыл бұрын
@@babitagarg1970 jo installation ke time Mojud tha use puch ke Dekhiye. Vaccume pump Ek Motor jesi aati hai. Wo process huyi thi k nahi.
@vivekjadhav4984
@vivekjadhav4984 Жыл бұрын
Did he charge you extra for vaccuming?
@pathikpatel010
@pathikpatel010 Жыл бұрын
@@vivekjadhav4984 in my case no i bought ac from Daikin authorised dealer. And they have very good technical staff. And they also gave me one feedback form that you are Fully satisfied with installation process 💙. For any other thing they can demand extra money but for vaccume don't need to give money. If technician is matured enough they will vaccume ac local dealers give installation to unskilled young boys and they will make your installation worst.
@ramkrishnadale7561
@ramkrishnadale7561 5 ай бұрын
For installation and uninstallion always prefer team from brand itself, I have reinstalled ac from local technican now struggling with leakage, low cooling, low aur through, improper installation and many more, at last called service team from brand.
@tech.Appliances
@tech.Appliances 3 жыл бұрын
Sir 1 point aur hai, air non condensable hoti hai, jis se compressor aur condenser work karta hai but air condense nhi Hoti to heat load badta hai, per refrigerant condensable hota hai, so Last Agar air hoti to system air ko bina faida khumayega
@erwinrommel09
@erwinrommel09 3 жыл бұрын
Great information sir
@anuragshukla6102
@anuragshukla6102 3 жыл бұрын
Sabse bada point sardaar ji jo aap miss kar rahe ho wo ye hai ki system me air hone se compressor ko jyada kaam karna padta hai jisse ki noise jayada hoti hai aur electricity jayada khata hai aur compressor ki life kam ho jati hai. Air jab compressor se jaati hai to liquid me nahin badalti jabki refrigerant liquid me badal jata hai aur high pressure air system me ghumti rahti hai, jisse future me gas leak ke chance bhi rahte hain.
@nvb_01
@nvb_01 2 жыл бұрын
already installation ho gaya without using vaccum. Ab usko theek kaise karein ?
@personallifeformat8696
@personallifeformat8696 5 ай бұрын
Aapko pichli videos me bhi vacuum ke bareme zaroor batana chahiye tha,kyon ki aap ko follow karke hi AC lagwaya tha,but mechanic bina vacuum ke hi installation kiya tha.😢
@ramsys9906
@ramsys9906 5 ай бұрын
Bhai saab. You have excellent talent of explaining very technical term in a very very simple manner, that even any layman (bilkul gawar) can understand. Most important looks like you value time, no nonsense start and right to the point.
@satishdhawan9417
@satishdhawan9417 Жыл бұрын
If one hasn't vaccumed the split inverter ac before starting what should he should have to do to rectify this mistake?
@avinashmali2542
@avinashmali2542 6 ай бұрын
I wanted to ask the same question.!
@visionarytomato
@visionarytomato 3 жыл бұрын
Sir is it mandatory to vacuum the unit when charging full gas?
@ayushtiwari3216
@ayushtiwari3216 5 ай бұрын
Paaji tum ho toh hamari ac hain bhot bhot sukriya knowledge share karne k liye
@asfakhusen6038
@asfakhusen6038 2 жыл бұрын
Bhai aap ki video bahut hi use full video hoti hai.. Great...
@Anantaadityashivam1
@Anantaadityashivam1 5 ай бұрын
Maine 10 baar ac lagwaya/shift karwaya hai aajtak kisi ne vaccum nahi Kiya ....next time Naya ac lunga to Bina vaccum ke aaya to bhaga dunga aur company me complain karunga
@SANTAMILGammy
@SANTAMILGammy 2 жыл бұрын
Friends... Vaccum process is 100% compulsory for ac installation....
@rohits-dk7rv
@rohits-dk7rv Жыл бұрын
Thank you so much sir. At the time of installation my AC technician didn't vaccumed the pipes. What should i do now? Please suggest me .
@emmvlogs
@emmvlogs Жыл бұрын
Don't worry... Chalne do ab use aise hi
@laibanush5431
@laibanush5431 Жыл бұрын
​@@emmvlogsBhai mera naya AC bhi lagate waqt vacuum nahi karwaya. Abhi toh waise chal rahe hain, lekin next kya karwa sakti hun?
@amrinderpalsinghbains1188
@amrinderpalsinghbains1188 Жыл бұрын
@@laibanush5431 kuch kiya kya aapne
@BankerBabuu
@BankerBabuu Жыл бұрын
Aajkal ye sale Installation wale mostly koi bhi Vaccuum ni karta... I also installed LG 1.5 ton split, after talking & fight, still guy didn't do vaccuum...
@rishabhgarg9371
@rishabhgarg9371 7 ай бұрын
@@BankerBabuu mera bhi aj hi install hua bhai...hajar bar use bolne ke bad wo vaccum cleaner lene gya...wo usko sath bhi lekar nhi aya tha aur bus 5 min dikhane ke liye lagaya aur bina pressure measure kare hata diya...uska koi interest ho nhi tha vaccum cleaning m....
@shyamsingh3108
@shyamsingh3108 3 жыл бұрын
Hi, agar ac already install kara liya h bina vaccum ke.. tab is problem ko kaise solve karenge ? Kya dubara uninstall kara ke vaccum karana padega?
@anuragshukla6102
@anuragshukla6102 3 жыл бұрын
Sardaar ji jawab do
@sherasingh9846
@sherasingh9846 2 жыл бұрын
Gas Nikal kr nitrogen se flush krke vaccum krke gas fil kro
@nareshdogra4639
@nareshdogra4639 2 жыл бұрын
Han sir btao
@forgottenaj5967
@forgottenaj5967 Жыл бұрын
Same big Question... Or Sacrifice
@Sz-ver
@Sz-ver 5 ай бұрын
Same question
@gopalkrishnaprasadadvocate
@gopalkrishnaprasadadvocate Ай бұрын
Gaya me Whirlpool Split AC installation Whirlpool ke Authorised Service center Technician outer unit se hi Vaccume kar AC Start kar dete hai kahne par bhi Vaccume pump ka upyog nahi karte hai.. Halaaki AC Coolling.. Good hai..
@saqibiqbalansari8225
@saqibiqbalansari8225 Жыл бұрын
Pls reply...Sir kindly clarify ki vaccum bas copper pipe me karwana hai ya aur kahi pe bhi ? Mera ac installation monday hona wala hai
@rahulprasad608
@rahulprasad608 15 күн бұрын
Sirf copper wire ke close loop Mai hi karana hai ..koi dikkat nahi hai..
@rajveersngh16
@rajveersngh16 3 жыл бұрын
Pata Nahi kyu mujhe sabhi Sikh log Bahut ache lagte hai
@harvinderdhillon3475
@harvinderdhillon3475 3 жыл бұрын
Kyuki, singh is king
@rajveersngh16
@rajveersngh16 3 жыл бұрын
@@harvinderdhillon3475 🥰🥰
@7starji506
@7starji506 3 жыл бұрын
Sir lg ac offering 10 year warranty on compressor , moisture problem will cover or not ... If not vaccum....at time of installation....
@Ramattra-ow
@Ramattra-ow 5 ай бұрын
Koi answer mila aapko?
@guddidevenda2832
@guddidevenda2832 2 жыл бұрын
sir ji installation k time vaccume nahi kiya mechanic ne , and ac bhi cooling nahi kar raha hai. kya problem ho sakti hai.
@meenrinku
@meenrinku 2 жыл бұрын
Same problem
@adityatiwari8044
@adityatiwari8044 Жыл бұрын
Kya AC ke drain pipe se panni nikalana zaroori he agar indoor unit me paani leakage nahi he me Rajasthan me rahata hoon per yeah per humidity Nahi hoti zada
@fitnessshorts1388
@fitnessshorts1388 4 ай бұрын
Sir mere Lg ka 2022 dual inverter Ac hai Installation k time pe technician ne vaccume nahi kiya tha lagaya tab se Kabhi bhi aaj tak room cooling nahi kiya
@i_m_ayushg
@i_m_ayushg Ай бұрын
kya voltas ac ke installation ke time vaccum bhi installation charg me include rehta h ya fr uska alg se charge rehta h ?? plz koi bataega
@pintukhankk
@pintukhankk Жыл бұрын
Meri to ac to bdiya chl rhi h .....lekin in baato ka ab aage se dhyan rakhunga.......but paaji ye btao ki jo bahr ke tar hote h copper ke outdoor ke..... insulation ke upar tap lawana jaruri h kya
@muhammadusmanmughal7106
@muhammadusmanmughal7106 2 жыл бұрын
Sir agar ac laqwa liya hai to kya wo vacuum ho sakta hai??
@shaunakpatil5915
@shaunakpatil5915 6 ай бұрын
PLEASE HELP !!!!!!!!! I Ordered Panasonic 1.5 3 star AC in Pune. However while installation the installation guy did not vacuum the machine. Unfortunately he "flushed" the pipes in his words and was arguing so much on his clear fault. I stopped the installation after that. He has not run the AC yet. My question here is can i still vacuum the AC? If yes what additional steps are there? Or should i ask for replacement??
@Clarkdale44
@Clarkdale44 6 ай бұрын
You can't do anything now. If possible, complaint to panasonic customer support and tell them technician didn't perform vacuum. Not vacuuming it will give long time issue.
@NJ-qg1fl
@NJ-qg1fl 3 жыл бұрын
Thank u sir for making this video. But tab kya karna chaiye jab technician ni kar ke jaye.. ab kya karein sir
@prashantkadukar3403
@prashantkadukar3403 28 күн бұрын
Thank You for this video!
@tajinderparnami4182
@tajinderparnami4182 3 жыл бұрын
Sir mere paas mitshubishi heavy 1.5 ton hybrid ac hai. Kuch din se usmein ek problem aa rahi hai. Jab on karte hai tab 2-3 min baad compressor apne aap band ho jata hai. Technitian ne pcb, capacitor ko ok bataya. Compressor band hone tak 7-8 amp current hi le raha hai. 2-3 technitian ko dikha diya. Unki jab samajh nahi aata to keh dete hai ke iska compressor change karna hoga. Kya compressor change karwa le?
@sonutigr2555
@sonutigr2555 5 ай бұрын
Thanks sir Ji bahaut hi badhiya tarike se apne samajaya or samaj aa bi giya❤❤ very very thanks
@harshitmohan5199
@harshitmohan5199 4 ай бұрын
Install karke ek din chalne ke baad karwa sakte hain?
@parthpatel1588
@parthpatel1588 3 жыл бұрын
2 month ago mera ek split ac install hua. Mene technician ko bola vacuum karne ko. But unhone outdoor ke valve ke pass se ek line se gas relise kiya or dusri line pe L- n key se pressure relise kiya then he open another valve. Kya esa karna sahi hai?
@XploreNortheast
@XploreNortheast 3 жыл бұрын
Sem mera v esa hi kiya jab maine bola ki ac installation k tym vacuum karna chaiye to wo log bola ki naya ac mai vacuum nhi karna hoga unlogo k pass proper tool's hi nhi tha
@ShivamSingh-vh5zd
@ShivamSingh-vh5zd 3 жыл бұрын
@@XploreNortheast bhai same with me ab kya kru .. pls help.
@anuronguha0898
@anuronguha0898 2 жыл бұрын
@@daringdpk3160 on point
@shLowKey
@shLowKey 5 ай бұрын
I am getting my Split AC installed today and I told technician to get Vacuum on the call. He told me he will do FLASHING. I think it is same to what you mentioned. But I told him to do Vacuum instead. He said he will not be able to do Flashing if he does Vacuum. Let's see what he does after coming home.
@manishverma7894
@manishverma7894 5 ай бұрын
Kya hua ​@@shLowKey
@lakshyaworld5010
@lakshyaworld5010 4 ай бұрын
Is it mandatory for split ac only or window ac too
@apurbanag777
@apurbanag777 3 жыл бұрын
Thank you, for your informative video.
@RohitKhadana
@RohitKhadana Жыл бұрын
Maine new ac installation karata tha to usne Vacuum nahi kiya. But 1.5 year achha chalata raha. Maine use fir se relocation karaya tab bhi vacuum nahi kiya. Aaj ac cooling nahi kar raha. Today engineer ne bataya ki gas Kam hai. 😢 Ab 3900 laga ke fir se gass fill Karana pada. Kas maine ye video pahile hi dekh Li hoti.
@abidlaskar9917
@abidlaskar9917 8 ай бұрын
just abhi bhaga dia vaccume macine nahi laya tha😢
@ayushgoyal5287
@ayushgoyal5287 5 ай бұрын
Bhai fr dowara aaya vaccume machine leke?
@user-amitgupta79
@user-amitgupta79 4 ай бұрын
Reply
@jahilmomin789
@jahilmomin789 3 ай бұрын
Vacum ke 500 extra mang raha
@ishwarsingh9511
@ishwarsingh9511 3 жыл бұрын
👌ਬਹੁਤ ਵਧਿਆ ਦੱਸਿਆ ਭਾਜੀ... You have a vast knowledge 👍
@AggressiveGamers141
@AggressiveGamers141 6 ай бұрын
Sir ye vaccum jab install krwae tabh hi krna hai na, alternative service pe toh nhi krwana hai???
@MegaPrams
@MegaPrams Ай бұрын
Agar apka ac lg ka ho to zaroor karaye , usme 3m pipe lagta hai jiski zarurat nahi hoti bahut case mai but wo log de dete hai , iske wajeh se air jyada reh jaata hai pipe mai to zaroor lg ka karaye
@ganeshgupta3426
@ganeshgupta3426 4 ай бұрын
Sir dono copper wire pipe vaccum hoti hai ya only one
@arunshaw3769
@arunshaw3769 5 ай бұрын
Sardar ji aap ne ac installation wala video me ye point miss kar diya hai jis ke wajha se maine aaj installation k samaye vaccum nahi kara paya aap wo video delete kar k phir se installation wala video me vaccum wala point add kijiye nahi to meri tarah or bhi koi vaccum nahi kara payega
@vivekjadhav4984
@vivekjadhav4984 Жыл бұрын
Does for vaccuming we need to pay any extra charges?
@imtarunchaudhary
@imtarunchaudhary Жыл бұрын
No
@Tyrus429
@Tyrus429 5 ай бұрын
agar Technician thodi gas pehle daal de aur phir woh gas puri pipe se hoti hui release kar dein air nikaalne k liye, but vaccum na karein aur baad main full gas release kar dein to kya yeh work karta hai ? Isme kya problem aa sakti hai, detail main batayein
@Amii-mv1hs
@Amii-mv1hs 7 ай бұрын
Technician ne self vaccume ki he...kha koi e problem hoga kya?
@vishalraj9832
@vishalraj9832 Жыл бұрын
Ager carrier ac ka gas free me dal de to vaccum karwaya ja skta hai kya?
@ParamjitSingh-dw5ob
@ParamjitSingh-dw5ob 7 ай бұрын
Most technician who come for installation are different n for repair ppl r different. Why . Bcz for installation service center uses least paid employees n most of them don't know there job n want to finish it in minutes bcz for any problem they wont be liable. This is the main reason why they don't vacuum.
@princesora4134
@princesora4134 3 жыл бұрын
Sir new ac fitting bahar se ya khud kr skte hai kya warranty avoid ho gee
@_jd21
@_jd21 3 жыл бұрын
Sir PLZZ make video on CROMA ac and it's models including complete review( pros and cons) ..PLZZ sir Maine pehle bhi bohot baar comment kia hai videos me..PLZZ make a video on that..u make best review and knowledgeable videos. Thnx..
@salmanfaraz148
@salmanfaraz148 2 жыл бұрын
Sir ji mene abi new ac lya h wo colling nhi kar kra room me to company wale ne vaccum karne ko kaha h... problem solve ho jayegi vaccum se???
@birbalbhartiya2012
@birbalbhartiya2012 2 жыл бұрын
Same problem
@amoxyt7879
@amoxyt7879 2 жыл бұрын
Fix hua kya bhai???
@Jaisalmertaxi
@Jaisalmertaxi Жыл бұрын
Problem solve ho gaya kya bhai please batao
@chandmd821
@chandmd821 5 ай бұрын
Maine 2 sal pahle Panasonic ka split AC liya tha fitting ke time per vacuum to nahin kiya Hua lekin usmein samel ki problem hai Jab outdoor band hota hai tab usmein samel aati hai aur outdoor chalu hone ke bad smell khatm Ho Jaati Hai Kya yah vacuum ki vajah se dikkat ho sakti hai
@TechnologyWorldHindi
@TechnologyWorldHindi Жыл бұрын
Bhai aapki 22min wali video dekhi thi woh sari chizo pe dhyaan diya tha lekin aapne vacuum wala koi topic hi nahi bataya tha aur installation wala bina vacuum kiye ac install karke chala gaya 8 din pehle… Ab kya kiya jaye??? 🥺
@pintukhankk
@pintukhankk Жыл бұрын
Same mene bhi esa hi krwa liya.....but ac to bdiya chal rhi h
@SanjayGupta-wh1vv
@SanjayGupta-wh1vv 3 жыл бұрын
Dar ji tusi great ho yaar
@RajPandey-zt2mo
@RajPandey-zt2mo 3 жыл бұрын
Aap ke advice se maine ftkz model liya lekin wo sahi kam nhi kr raha shayad technician theek nhi hai
@VikasKumawat1992
@VikasKumawat1992 3 жыл бұрын
Isliye aap dhang ke technician se install karwaiye
@gauravbishnoi_17
@gauravbishnoi_17 3 жыл бұрын
Thanks for sharing the important & knowledgeable information. Thanks so much 👍
@vickythakur8751
@vickythakur8751 Жыл бұрын
Bhai ji ac ki pipe bend Krna say cooling mai koi problem atti hai kya
@Abhishek_.Bishnoi
@Abhishek_.Bishnoi 3 жыл бұрын
Paaji haryana government jo subsidi scheme laayi h AC ke liye uspe video bnao, please🙏 Or jo AC h unka description bhi bta dena🙏
@pallabhazarika7540
@pallabhazarika7540 15 күн бұрын
Nice sir good idea
@uttamdey6534
@uttamdey6534 4 ай бұрын
Hi sir, mera ac main ek minor leakage tha in door flair main, service engineer ne 2 time nitrogen gas hold karke leakage check kiya tha but they didn't vacuumed after finding leakage, then they again refill gas now a days discharge pipe main ice build up ho raha jab ac on kar hara hu but after 5-7 min wo chala ja raha hai.some i fill ke less cooling ho raha hai.plz give solution.
@ShivamSingh-vh5zd
@ShivamSingh-vh5zd 3 жыл бұрын
Sir my ac installed without vaccum .. pls suggest me what should i do.
@SANTAMILGammy
@SANTAMILGammy 2 жыл бұрын
Don't worry bro. In future... Gas low problem means... Contact proper ac mechanic and tell him to vaccum and install
@themeasurement
@themeasurement 2 жыл бұрын
15 days hue hain split AC install ko lekin installer ne vaccum nhi kiya tha to kya ab ho sakta hai vaccum? Must reply..
@VISHALSINGH-li8ob
@VISHALSINGH-li8ob 2 жыл бұрын
Same here
@kishorearora714
@kishorearora714 4 ай бұрын
very good information sir ji..
@HS-re7dw
@HS-re7dw 3 жыл бұрын
I have installed a ifb ac and they did not do vaccuming even after having a vaccum pump .My ac must have ran for 10 min or so ... What can I do in this case ?
@VikasKumawat1992
@VikasKumawat1992 3 жыл бұрын
Aapko vaccuming karwani chahiye
@HS-re7dw
@HS-re7dw 3 жыл бұрын
@@VikasKumawat1992 Even after ac has started. Would it help
@tarungupta7751
@tarungupta7751 3 жыл бұрын
Same ques. I purchased ifb ac 10 days ago and they didn't vaccum it. What to do now
@VikasKumawat1992
@VikasKumawat1992 3 жыл бұрын
@@tarungupta7751 it will cost you more if you will vaccum now. If anyone is using AC without vaccuming then it's performance is reduced
@HS-re7dw
@HS-re7dw 3 жыл бұрын
Well I complaint to Ifb and my vaccuming is getting done as I type this msg just for my satisfaction.
@chiranjitdhar2608
@chiranjitdhar2608 9 күн бұрын
New ac install karneke samay technician ne vaccum nahi kiya tha. To koi problem ho Sakta hai kya? Lekin ek baat ac colling achha hi kar raha hai.
@emmvlogs
@emmvlogs 7 күн бұрын
most nahi karte, chalate rahiye aap jab tak cooling me koi problem na aaye
@chiranjitdhar2608
@chiranjitdhar2608 6 күн бұрын
@@emmvlogs thank you sir for reply 🙏🏻 bad mein jab ham technician ko bola tha to usne bola ke usne self vacuum kar diya hai. Haier ka new kinouchi model hai cooling capacity 5125w hai bus 6 month hue hain. lekin Cooling bahut perfect kar raha hai. Per tension ho raha hai ke technician to vacuum motor pump se nahin kiya hai na isliye.
@pratikpaithane352
@pratikpaithane352 Жыл бұрын
Hello maine abhi split AC liya Hain Panasonic ka 2023 model Feb ka but installation walo ne vaccum nhi Kiya h kya ac main ab koi problem aaegi !?
@ritanbarman
@ritanbarman Жыл бұрын
Flipkart se ya Amazon se liya tha?
@pintukhankk
@pintukhankk Жыл бұрын
Meri bhi same ac h.....vaccum ke bare me pata nhi tha.....ac to sahi chal rhi h....kya kre
@vickyartsgrafix991
@vickyartsgrafix991 5 ай бұрын
Sir humne without vaccum ke installed kardiya hain technician ne baad mein abhi karwa sakte hain kya
@starsfansclub8813
@starsfansclub8813 5 ай бұрын
kra sakte h but puri gas nikal kar first nitrogen se pure system ki cleaning hogi taki jo moisture inside h vo saaf ho jaayega nd fir copper pipe and indore ,outdoor unite ka vaccume krke gas fill karega...
@asb.605
@asb.605 3 жыл бұрын
Ssa virji. Virji mere pass voltas ka 1.5 ton split ac hai. Uske compressor ke thimber baar baar jal jaate hai. Iska solution kya hai ji ?
@mahaveerkardam7978
@mahaveerkardam7978 3 жыл бұрын
Grace laga bhai
@raghavmunjaal4770
@raghavmunjaal4770 Жыл бұрын
Sir aaj AC install karwaya, technician ne vaccum nahi kiya. Abb kya kiya ja sakta hai? Kya usse call krke firse vacuming krke Jane ko bolen toh dikkat solve ho jaegi?
@pintukhankk
@pintukhankk Жыл бұрын
Bhai me bhi bhul gya
@feenixxx889
@feenixxx889 5 ай бұрын
Bhai nhi kia vaccum usne aise hi install krdia ..ab dhang se cool hi nhi kar rha isi liye mai zyada ton ka lgwaya tha 2.4ton haier inverter ab wo air cooler jaisa chll ra kya karu bulakar dobara vaccum nhi kara skta kya ??
@Jedi-em2qd
@Jedi-em2qd 5 ай бұрын
KYA WINDOW AC ME BHI KRANA HOTA H VACUUM.??
@karansoni3567
@karansoni3567 3 жыл бұрын
Sir dual inverter vdya ya triple inverter ac
@pradiprana9860
@pradiprana9860 5 ай бұрын
Thanks sirjee achchi jankari mili 💟
@vivektrivedi6838
@vivektrivedi6838 6 ай бұрын
Sir ji installation ke time mujhe ye baat pata nahi this. Kya main ab karva sakta hu?
@sunnysaini3974
@sunnysaini3974 3 жыл бұрын
Sir kya jab brand technician ac fit krne ath h to kya wo vacuum sath mai leke ate h g and kon sa brand ka technician vacuume lekar ate h ya fr sabhi brands apne technician ko vaccume ke liye kehte h
@memory-z7x
@memory-z7x 3 жыл бұрын
तेरी बात तो समझ गया लेकिन typing सही से कर😂
@hungryformorevlogandkitchen
@hungryformorevlogandkitchen Жыл бұрын
Aj ac install hua but chalu niya kiya due to electric kam baki hai to meh kya vacuum karva sakta hu
@rockyharyanvi
@rockyharyanvi 3 жыл бұрын
Pajji ye jo chemical wala coil cleaner aata hai usse coil ko koi harm to nhi hota or ye coil chemical se clean karni chahiye ya nhi
@GulshanKumar-hy7ty
@GulshanKumar-hy7ty 3 жыл бұрын
Harm hota hai agar baar baar chemical se service karvaoge to
@jigneshshah5529
@jigneshshah5529 3 жыл бұрын
Bilkul use nahi karna chahiye, only water with mild soap use kar sakte hoo aur uss k baad bhi fresh water se wash karna zaroori hay. Cleaner acidic ya highly alkaline nahi hona chahiye. Mildly alkaline chal sakta hay jaise ki mild soap water.
@vipulpanchal9852
@vipulpanchal9852 2 жыл бұрын
Sir ji ac lagaye 3 Sal ho chuke ab Garmi suru hone vale he service ke sath sath veccume karva sakte hai
@emmvlogs
@emmvlogs 2 жыл бұрын
No need if machine is working well
@RahulChandra1
@RahulChandra1 4 ай бұрын
Bhai mera wala technician vaccum nhi kiya , aise hi connection kar diya, voltas ka hai AC
@KapilSharma71180
@KapilSharma71180 Жыл бұрын
Sir maine 2 lloyds ac lagwaye hai abhi ... technician nai bina vaccum kiye ac install kar diya hai ab kuch kar sakte hai ya....
@AmitSharma-s6o
@AmitSharma-s6o 6 ай бұрын
Bhai koi dikkat nahi hohi Vaccum vaha par hi jaroori hota h Jaha pr already fitting ho rakhi hoti h ya pipe pehele se fit hote h Vaha gandgi, paani sab chala jaata h Esliye vaha vaccum.krna compulsory hota h Normally vaccum ki kahi pr aavshayakta nahi hoti To tension mat lo AC ke.maje lo
@ankitmaddheshia6565
@ankitmaddheshia6565 3 жыл бұрын
Sir humre gher ke bhahar nala hai bada wala show wich ac we prefer
@nileshpala8757
@nileshpala8757 3 жыл бұрын
Hi bro, mere pas LG Q18MNZA 1.5TON ka model he, jab AC start karane kar ne ke bad indoor me se thodi-bahut gus ki badu aati he to kya ye problem vali bat he?or abhi 8mounth hi Hua he warranty hi he to kaya kare?
@Comedyshorts3575
@Comedyshorts3575 2 жыл бұрын
Lodge a complaint
@satbeersingh9369
@satbeersingh9369 3 жыл бұрын
Mene new ac lgya he lekini vacuum nhi kiya ab koi problem to nhi hogi?? Blue Star non inverter 1.5 tn ka he
@birbalbhartiya2012
@birbalbhartiya2012 2 жыл бұрын
Same problem answer sir
@melophile04
@melophile04 2 жыл бұрын
Vaccuum reading wise kitta hona chiye meter me?
@Paramjit_sir
@Paramjit_sir 3 жыл бұрын
भाई एक वीडियो स्प्लिट ac में क्लीन फीचर आता है उसका बताओ मेरे पास गोडरेज का है
@ABDULRAHMAN-fr9tv
@ABDULRAHMAN-fr9tv 3 жыл бұрын
Sir ji snow wala ac cleaner jo aata hai uske baare me vedio bana dijiye
@sourabhbansal1993
@sourabhbansal1993 Жыл бұрын
Sir, suction pressure in my newly installed Mitsubishi Electric AC is 195 and its cooling efficiency is very very low...technician checked and he is clueless that what could be wrong...does the improper vacuum be reason for this?
@emmvlogs
@emmvlogs Жыл бұрын
might be or impure gas
@sourabhbansal1993
@sourabhbansal1993 Жыл бұрын
@@emmvlogs thanks 🙂
@ishangupta6204
@ishangupta6204 6 ай бұрын
Sir mene ac install karvaya tha to ac tecneshian ne -2 tak kewal vaccum kiya tha to kya kare please reply
@Clarkdale44
@Clarkdale44 6 ай бұрын
20-40 min lagte hain -30 tak aane mein. Ab kuch nhi ho sakta... agar koi cooling problem nhi hai to chalao. Otherwise complaint karo ki technician ne proper vacuum nhi kiya.
@manishgothariya6490
@manishgothariya6490 3 жыл бұрын
Sir kya amazon ya flipkart se Ac Lena thk rahega kya koi dikkat to nahi aati h warranty me ya product original please reply
@AjayYadav-vf1fm
@AjayYadav-vf1fm 7 ай бұрын
Koi dikkat nhi hoti' warranty toh company deti hai
@VIKKIKSAIN
@VIKKIKSAIN 3 жыл бұрын
Sir AC Installation ke time gas company ki or se aati h ya technision dalta h
@sarabjitsidhu6928
@sarabjitsidhu6928 3 жыл бұрын
Its already stored in outdoor unit by company. After installing and vacuuming technician release it
@TrekwithNix
@TrekwithNix 7 ай бұрын
Paji, maine parso hi Ogeneral ka itne expensive split ac lekar install karwaya par technician ne vaccum nahi kiya, ab kya kar sakte hain?
@AjayYadav-vf1fm
@AjayYadav-vf1fm 7 ай бұрын
Bhai complaint kr do online customer care par
@TrekwithNix
@TrekwithNix 7 ай бұрын
@@AjayYadav-vf1fm bhai ek baar outdoor unit se gas flow ho gayi toh ab complaint karne se bhi kuch nahi ho sakta
@Clarkdale44
@Clarkdale44 6 ай бұрын
Complaint karo ki technician ne install manual ke according vacuum nhi kiya. They should vacuum your unit and refill it free of cost.
@KaifKhanOfficial
@KaifKhanOfficial 6 ай бұрын
Village Area ke technician ke paas vaccum nahi hota to kaise install kar waee ??
@Goldenk496
@Goldenk496 6 ай бұрын
Thank you pajee for information 😊
@go-getter2682
@go-getter2682 4 ай бұрын
Means gas refilling ke baad bhi ek baari vaccum krani chahiye!!
@drpraviinsingh
@drpraviinsingh 3 жыл бұрын
Sir abhi tak apne cyclojet ac par video nhi banai na hi koi reply diye😒😒😒
@mohitaneja6212
@mohitaneja6212 2 жыл бұрын
Maine new ac lagaya hai 7-8 din pehle, Lekin technician ne vaccum nahi kia, Kya abb use vaccum karwa lein??? Please reply🙏
@being_ayush
@being_ayush 2 жыл бұрын
ab Vaccum karwane pe aapko Gas refill Karana padega because wo leak ho jaayegi jab copper pipe open hogi..... jiska alag se charge dena padega gas refill ka
@musclefitmachine7211
@musclefitmachine7211 Жыл бұрын
Do we need to vaccum every time if there is leakage and needs to fill ac gas after fixing leakage??
@Purushottamkr
@Purushottamkr Жыл бұрын
no
@AshwaniRajput3451
@AshwaniRajput3451 7 ай бұрын
नमस्कार जी, क्या एसी फिटिंग के समय एसी का वैक्यूम करने का अलग चार्ज होता है यदि होता है तो कितना चार्ज होता है
@Clarkdale44
@Clarkdale44 6 ай бұрын
koi charge nhi hota.
@sharadgaur9756
@sharadgaur9756 2 жыл бұрын
Sardar ji reply Bhi de diya karo kitne Logo Ne aapse poochha hai par aapane kisi ko reply nahi diya ese hi Chalte Hai Kya KZbin channel
@anuragshukla6102
@anuragshukla6102 3 жыл бұрын
Mera to is wajah se split AC se yakeen hi chala gaya hai Window AC me ye issue nahi hai kyunki usme gas line sealed hi rahti hai, gas kholne ka aur pipe connection ka koi issue nahin hota
@Redmirealme1234
@Redmirealme1234 Жыл бұрын
But sir windows ac me noise problem bhi h toh h
@buntysrivastava2319
@buntysrivastava2319 3 жыл бұрын
सर हमने नयी ऐसी लगाई पर उसने व्यकूम नही किया वोल्टास सर्विस सेन्टर वालो ने।
@sureshkatre732
@sureshkatre732 Жыл бұрын
इनका तो धरम हो गया है मैने भी voltas 1.5 लिया है वैक्यूम नही हुआ बोले जरूरत नहीं है
@abhilash71294
@abhilash71294 Жыл бұрын
What if I remove the vaccum pump before opening allen key volve? I actually removed the vaccum pump line from ac before opening allen key volve, and it sucked some air for like 0.5 seconds. Did I ruin my AC?
@Clarkdale44
@Clarkdale44 6 ай бұрын
Yeah, some air entered. After vacuumed, you needed to open allen key valves only then remove the line, this way gas won't let the air in when line is removed. But shouldn't matter much.
@techsavvy3942
@techsavvy3942 3 жыл бұрын
Zabardast information bro
버블티로 부자 구별하는법4
00:11
진영민yeongmin
Рет қаралды 28 МЛН
兔子姐姐最终逃走了吗?#小丑#兔子警官#家庭
00:58
小蚂蚁和小宇宙
Рет қаралды 13 МЛН
the balloon deflated while it was flying #tiktok
00:19
Анастасия Тарасова
Рет қаралды 34 МЛН
Smart Sigma Kid #funny #sigma
00:14
CRAZY GREAPA
Рет қаралды 87 МЛН
vacuum nhi karne se aap ke ac me ye problem aa jaye gi
3:55
SMART AIR COOL SYSTEM
Рет қаралды 13 М.
버블티로 부자 구별하는법4
00:11
진영민yeongmin
Рет қаралды 28 МЛН