star delta starter control circuit diagram star delta connection

  Рет қаралды 134,907

ELECTRECA

ELECTRECA

Күн бұрын

Most induction motors are controlled by the direct online starter, however, the heavy motor with the heavy load if there started using direct online starter Huge voltage surge(voltage surge can damage electronic equipment, small machines and the contractor that is supplying the same circuit)because of the high current that is drawn from the supply.
Parts that make up the starter
1) 3 Contactors (main contactor, star contactor and delta contactor)
2) Auxiliary contact(with NC) for each contactor
3) On delay timer
4) Thermo overload relay
5) Control breaker(double-pole)
6) Push-button(2)(start and stop)
Here is how the control works or clicks here electrecasolutions.com/unders...
When the ON push button starts the circuit by energizing the star contactor(S) and the timer(T) at the same time. The star contactor(S) get energized through NC of the timer(T) through NC of the delta contactor(D).when star contactor(S) is engaged(energized) it closes its auxiliary contact NO through which the main contactor(M) get energized.
The circuit will run for the set period of time normally (a few seconds) and timer (T) will open NC and closes NO through which delt contactor (D) get energized.
NOT because the main contactor(M) is energized through the star contactor(S), we don’t want it(main contactor) to go off when the star contactor is disconnected, that’s why we make a parallel connection between star contact (Y AUX) and main contactor (M AUX2).
STAR DELTA STARTER VIDEO • star delta starter con...
TIMER VIDEO • How on delay and off d...
FORWARD REVERSE WIRING DIAGRAM VIDEO • forward reverse switch...
FORWARD REVERSE WIRING VIDEO • forward reverse motor ...
CONTACTOR SELFHOLDING VIDEO • contactor self holding...
contact me here
electreca.workshop@gmail.com
follow me on Twitter / davidssengendo
like my Facebook page / electerca
Visit my blog electrecasolutions.com/blog/
Buy contactors here amzn.to/39iW0p2
Push buttons amzn.to/3qN2DpN
AI Digital Multimeter amzn.to/2R1Q2mp
Disclaimer: ELECTRECA is a participant in the Amazon Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to www.amazon.com

Пікірлер: 160
@berkotropia
@berkotropia Жыл бұрын
You are very nice guy who explains simply and accurately. The problem is this industrial electrics that there are too many arrogant and bully engineers there who purposely confuse you and let you down. If I had more people like you, my studies could have been less painful. Thanks!
@electreca1
@electreca1 Жыл бұрын
I appreciate the compliment and thanks for watching.
@abednigojustin3508
@abednigojustin3508 Ай бұрын
Great job brother....but just a suggestion...why not use the auxiliary contact (NO) of the delta contactor to keep the main contactor energised when the star connection time elapses..... because using the auxiliary contact of the main contactor mean when the start push button is pressed the main contact also start immediately....
@seanakiiki7670
@seanakiiki7670 3 ай бұрын
I really appreciate u, u have helped me as an electrician to understand more about automation industrial engineering,long live, god bless you, iwill let my son studying begin to follow ur lectures on line, thxu Best regards
@mathewsnyirenda4004
@mathewsnyirenda4004 Жыл бұрын
Great works indeed. Am learning every day
@morgankpabitey1837
@morgankpabitey1837 3 жыл бұрын
Thank you so much. This is crystal clear.
@electreca1
@electreca1 3 жыл бұрын
You're very welcome!
@siamankangasam6414
@siamankangasam6414 Жыл бұрын
You're a great engineer sir
@Lyricalist_k
@Lyricalist_k Жыл бұрын
I love this channel now,I found it today and am really grateful🎉🎉good work mwalimu,came here after not understanding in class😅
@samuelmainakamunye571
@samuelmainakamunye571 Жыл бұрын
good work and educative lesson
@ayodeleelijah3257
@ayodeleelijah3257 Жыл бұрын
Thanks for the explanation 👍👍👍
@thabisodlamini41
@thabisodlamini41 Жыл бұрын
Thanks Sir, today you made my day well presented video I did understand every single word you spoken
@electreca1
@electreca1 Жыл бұрын
Glad to hear that and Thanks for watching
@mohdfauzeerosslie7515
@mohdfauzeerosslie7515 Жыл бұрын
ty my man. simple explainantion.
@lesliemaloba1825
@lesliemaloba1825 Жыл бұрын
Great explanation indeed
@seanakiiki7670
@seanakiiki7670 3 ай бұрын
I love u so much ur videos are good and well scientifically explained,
@ezekiellaini9530
@ezekiellaini9530 Жыл бұрын
Well explained to the point 💪
@electreca1
@electreca1 Жыл бұрын
Thanks for watching
@siamankangasam6414
@siamankangasam6414 Жыл бұрын
Very lovely, you have made me go back to school
@electreca1
@electreca1 Жыл бұрын
Thanks for watching.
@bisoborwaseaneilly7080
@bisoborwaseaneilly7080 Жыл бұрын
So good sir am learning and enjoying thxu
@sohailjanjua123
@sohailjanjua123 Жыл бұрын
Hi , I like your video. Thanks
@user-ok1sr6xd5p
@user-ok1sr6xd5p 5 ай бұрын
Great job sir❤
@kumning3331
@kumning3331 9 ай бұрын
thanks, well presented
@IzoKey-iy9zq
@IzoKey-iy9zq 2 ай бұрын
Thanks your for the teaching
@bisoborwaseaneilly7080
@bisoborwaseaneilly7080 Жыл бұрын
Sir ur very true and perfect thxu
@Prosper_Electrical.
@Prosper_Electrical. 3 жыл бұрын
I follow you Everytime
@electreca1
@electreca1 3 жыл бұрын
Thank you every much
@basilmasvikeni9931
@basilmasvikeni9931 Жыл бұрын
Good stuff man
@erick2pac360
@erick2pac360 Жыл бұрын
Uv made me clearer
@user-gt4wf8pv5k
@user-gt4wf8pv5k 11 ай бұрын
Good explanation
@fredericokasper7854
@fredericokasper7854 2 жыл бұрын
Thanks!
@viavictoreletrica3527
@viavictoreletrica3527 2 жыл бұрын
Excelente profissional
@mohameddzugwe6813
@mohameddzugwe6813 Жыл бұрын
Thank you
@LameckPhiri-ex9bj
@LameckPhiri-ex9bj 9 ай бұрын
Good job bro continue teaching us
@electreca1
@electreca1 9 ай бұрын
It's my pleasure
@adventurendaba9020
@adventurendaba9020 2 жыл бұрын
thank you broe
@bonnymazhara1396
@bonnymazhara1396 Жыл бұрын
Thanks engineer
@leomichael3433
@leomichael3433 Жыл бұрын
Good job thanks for this
@tanginandjedhi6982
@tanginandjedhi6982 3 ай бұрын
thankz sir for yourb clear explanation
@user-ox8zd3zk5g
@user-ox8zd3zk5g 6 ай бұрын
This is very nice
@okolceaser6056
@okolceaser6056 Жыл бұрын
It's good on that circuit to protect the timer
@ongomsamuel2896
@ongomsamuel2896 2 жыл бұрын
Good Engineer
@oviaudhimbamatuyeeviyiwana2819
@oviaudhimbamatuyeeviyiwana2819 2 жыл бұрын
Plus is the power being supplied through the main contactor or from where is the power coming from since on the main there is no where it's indicated as to where the power is coming from to the main contactor ?
@mahmoudkamal8673
@mahmoudkamal8673 2 жыл бұрын
great keep going sir
@electreca1
@electreca1 2 жыл бұрын
Thank you, I will
@elibarickandrew4496
@elibarickandrew4496 7 ай бұрын
Good explanation but you said in this circuit star contactor should energize first before main contactor. Qn why star first while the motor will not start if both main and star are not energized.
@johnkapauo2995
@johnkapauo2995 2 ай бұрын
He just explain the logic here. If you see it properly, I think you'll see, the main idea here is the ADDRESS. The contact that the main rely on relies on the address of the star coil, so star has to come ON first followed by the main, bear in mind that that happens in short space of time (as he mentioned, by the blink of an eye), so if the motor relies on the main, then the motor won't start if star coil is OFF or not energized. This is the result of main not being energized, hence causes the motor to remain OFF.
@anthonydicksonojih5079
@anthonydicksonojih5079 2 жыл бұрын
Thanks very much
@electreca1
@electreca1 2 жыл бұрын
You are welcome
@umakanthbojanapalli3240
@umakanthbojanapalli3240 2 жыл бұрын
Valuable information sir
@electreca1
@electreca1 2 жыл бұрын
Thanks and welcome
@umakanthbojanapalli3240
@umakanthbojanapalli3240 2 жыл бұрын
@@electreca1 plz send you complete panel wiring video's interlock manually auto motor protected and all 11&33&110&220&400&600 kV vcb power really wiring and ct pt box termination and drawing and small trans former design wire selection core selection bobbins selection and formulas releate charts PDF and every panel wiring PDF and substation commission and PLC and every thing electric part send videos
@tinashemuparangi2978
@tinashemuparangi2978 2 жыл бұрын
mr sir there is no reason to interlock the main contactor. the main and the star come in together at the same time. lets assume we are using pneumatic timer that means it should be coupled with the main contactor..maybe u can add a hold in for delta and disconnects the timer from the by adding normallt ope interlock for delta on timer circuit.
@abubakarmusa135
@abubakarmusa135 2 жыл бұрын
P
@kayitamoses8580
@kayitamoses8580 Жыл бұрын
The main contactor just latches and keeps switched on
@mwangijohn538
@mwangijohn538 3 жыл бұрын
Thanks David, during demonstration,u said this goes here , and that goes there, especially energizing the main contactor, there are terminal, there marked 13 ,22 and 14: and 21 so which one do mean inside nor out, please clarify by naming the terminal nos and either no or nc
@umakantamirdha9019
@umakantamirdha9019 2 жыл бұрын
Pppppppp hi nhi ho skta ki a hai pyar ki asi thila ok I
@vincentowira6743
@vincentowira6743 2 жыл бұрын
Good job bro, but main and the star contactor comes in at the same time.
@learnwithemmy123
@learnwithemmy123 3 жыл бұрын
Very good content. Keep the good work.
@electreca1
@electreca1 3 жыл бұрын
Thank you
@erick2pac360
@erick2pac360 Жыл бұрын
Knowing starters and backups means that am done with automation??
@linossinkala7840
@linossinkala7840 3 жыл бұрын
Super
@denofilms2438
@denofilms2438 Жыл бұрын
Good job.. Iam requesting you do alarm bell sirens using relay for 8,12,14 pin. And using relay in controls more machines
@electreca1
@electreca1 Жыл бұрын
OK will consider, thanks for watching
@jameschitala3753
@jameschitala3753 3 ай бұрын
Very educative sir....thanks alot. I have a question: if the main contactor energizes last then, which contactor does the holding role?
@MutenderiYafesi
@MutenderiYafesi 2 ай бұрын
Good work papa
@electreca1
@electreca1 2 ай бұрын
Appreciated
@bezibedie4259
@bezibedie4259 10 ай бұрын
How can you put an isolation switch in this wiring ?
@GeovaniYakubu
@GeovaniYakubu Ай бұрын
That's good
@martin6934
@martin6934 7 ай бұрын
How can someone solarize the induction motor especially the star delta ones? Which inverter?
@mahamudabdullahi7506
@mahamudabdullahi7506 3 жыл бұрын
You explained very well come up with practical. and I request you to repeat on forward and reverse especially on the indicators that is my big problem
@electreca1
@electreca1 3 жыл бұрын
No problem I'll do that
@mbuthianjoroge9434
@mbuthianjoroge9434 3 жыл бұрын
Kazi nzuri boss
@electreca1
@electreca1 3 жыл бұрын
Asante
@yesuanaokoamtumainiyeye1360
@yesuanaokoamtumainiyeye1360 3 жыл бұрын
Nakubali mzee Nope namba zako nikucheck mkulu
@kindmanmundingi8588
@kindmanmundingi8588 11 ай бұрын
What wil happen if a main contactor energised before the star and the star pulls in after?
@prashanthsadam9048
@prashanthsadam9048 6 ай бұрын
Hi what will be happening if main contact and star contact at a time start
@igwekelechifebian781
@igwekelechifebian781 Жыл бұрын
I was really getting the mode of operation,but got confused about the illustration on main contact connection after the star disengage
@abdulhamidmirzaee3097
@abdulhamidmirzaee3097 10 ай бұрын
Hi. Thanks for the video. One question: Why the NO of the timer is needed before delta contactor. Delta contactor will energize without the timer NO being there.
@-1HUMANITY-
@-1HUMANITY- 6 ай бұрын
Can it gets energized without no
@piusngibeyo5161
@piusngibeyo5161 3 жыл бұрын
We are approaching amillion subscribers, bro thanks for your videos that are educating am from turkana county
@electreca1
@electreca1 3 жыл бұрын
Thanks so much Pius....by the grace of God and hard work we will hit a million
@nkailefrance665
@nkailefrance665 2 жыл бұрын
Please add yu number sir if we need any assistance we will contact you.......or we can great group....
@oyenaraymond6520
@oyenaraymond6520 Жыл бұрын
My question is star Auxiliary is closed or open? that's what am not getting....in the explanation u Said it's closed but in the diagram it's open so.....
@sseguyazakiyu4112
@sseguyazakiyu4112 Жыл бұрын
Hlo sir thx
@sahiln3d514
@sahiln3d514 3 жыл бұрын
Good work , congrats.. But sorry we need pratical if possible . God help you
@electreca1
@electreca1 3 жыл бұрын
I did a practical video for this topic, however, some viewers requested more clarification on the circuit diagram.................. here is the practical video kzbin.info/www/bejne/rZaafquAZcudeq8 Thanks for watching.
@geoffreysakala8496
@geoffreysakala8496 Ай бұрын
Hi.... can i find a video on how to install a 3phase submersible pump
@ericmassamaki2498
@ericmassamaki2498 Ай бұрын
it's better you could write the tarminal number of those devices so that some of us could be easy to know after what goes to number what thank you.
@user-jf9pv5us3x
@user-jf9pv5us3x Ай бұрын
Can you tell how it switches from high voltage to low?
@JOFREYNgimba-pk5ur
@JOFREYNgimba-pk5ur 9 ай бұрын
You mean maincontactor Will consist Three auxiliary which is normal open?
@ishackbugum8179
@ishackbugum8179 4 ай бұрын
What is the purpose of the star Auxiliary contact on the main contactor sir
@oviaudhimbamatuyeeviyiwana2819
@oviaudhimbamatuyeeviyiwana2819 2 жыл бұрын
Why do we need the main contactor in our circuit. Is the circuit not gonna work if removed?
@electreca1
@electreca1 2 жыл бұрын
The main contactor help to hold the circuit that's why we use push button to make the circuit more safe to operate and reliable, if you remove main contactor then you have to use a switch(not push button) which will keep the timer permanently on during operation. As long as the timer is on, circuit will remain running.
@josephnthungu
@josephnthungu 2 жыл бұрын
Brother thank you for your video.But i have a qsn about the second Main auxilliary you have introduced down there.Can you just make a loop wire from Main auxilliary and bring down and bypass it,and connect at the second terminal of STAR AUXILLIARY BLOCK?
@electreca1
@electreca1 2 жыл бұрын
If you do that the Main contactor will engage before the Star, yet our primary goal is the Star to engage First
@josephnthungu
@josephnthungu 2 жыл бұрын
Bro.now it's clear now after i followed your video and demonstration
@ebenvanstaden5364
@ebenvanstaden5364 Жыл бұрын
How long are timer set before the Delta get enrgized which are going to be brought in by the timer coil...because the minute you leave the start button ,the circuit will be de-energized,start wont be retained because the main contactor dont have power yet ....meaning the entire circuit will fall out again...star en timer
@Ngobisamuel-rh9sw
@Ngobisamuel-rh9sw 3 ай бұрын
Bro , I request u to take us through motor winding
@user-bp6hh4re2g
@user-bp6hh4re2g Жыл бұрын
Can you pls show me how do star delta foward reverse with four magnetic Contactor and one timmer
@bonnylasu7665
@bonnylasu7665 Жыл бұрын
Sir very interesting but can you change your colour of marker? Your writing not clear for star, delta wiring
@prashanthsadam9048
@prashanthsadam9048 6 ай бұрын
In this star delta connection after few seconds circuit will change star to delta in this time main contact in on position here any happend?
@bobojanespaner9761
@bobojanespaner9761 3 жыл бұрын
please add temperature sensors on your circuits as well as use of vfds
@bobojanespaner9761
@bobojanespaner9761 3 жыл бұрын
also add just morethan one timer on your circuits
@sahilnawab894
@sahilnawab894 2 жыл бұрын
Thankyou sir 🙏😊😌
@electreca1
@electreca1 2 жыл бұрын
Most welcome 😊
@nkosinathimnisi5990
@nkosinathimnisi5990 2 жыл бұрын
We have circuits that put in the main and star at the same time is it wrong ? If yes tell me why?
@ongomsamuel2896
@ongomsamuel2896 2 жыл бұрын
Do you deal with only 33kv or even the single phase
@chidiemelobe1044
@chidiemelobe1044 2 жыл бұрын
Good. But I think it will be nice if the timer coil can be de-energize after switching to delta
@electreca1
@electreca1 2 жыл бұрын
The timer I used it Normally closed, so it has to be and remain energised to hold the Delta contactor on. If the timer coil de-energise then delta will lose power. What do you think?
@FowziaMohamud-pi5fh
@FowziaMohamud-pi5fh 7 ай бұрын
Eng.what is the diffrence between delta connection and dol
@praisepola3886
@praisepola3886 Жыл бұрын
so a star and a mean work like a duble mcb
@binnasser-rj5id
@binnasser-rj5id Жыл бұрын
Bro! My question is when push button pressed the phase will pass to Timer and start to count as as main contact make the also pass to normal close of timer and pass to Auxiliary contact of delta contact then to A1 of start contact, I'm confused to this Auxiliary contact which will put above the contact start since we use the NC aux when pass phase make and become open while holded to cont start why still make because NO means phase will blocked via to star contact ???
@konithierry9475
@konithierry9475 Жыл бұрын
Good job bro please my question is how can you wire it involving emergency push button
@electreca1
@electreca1 Жыл бұрын
you can wire you Emagency buuton circuit beaker and Overload relay. thanks for watching
@okolceaser6056
@okolceaser6056 Жыл бұрын
Timer protection these days is recommended coz the timers in market are week ,let the timer be switched from NC delta and on the timer switch NO put a hold cct from no delta
@okolceaser6056
@okolceaser6056 Жыл бұрын
Put NC for delta to switch timer ,then put hold on contact on timer NO to switch delta this will help timer to be always off when motor is running on delta contact
@user-ox8zd3zk5g
@user-ox8zd3zk5g 6 ай бұрын
Kindly am asking if you can assist me with the traffic light circuit diagram
@konnehzinnah3124
@konnehzinnah3124 Жыл бұрын
Thanks brother for the video. It's good. Point of injection: Use the main contactor NO across the start pb switch so it serves as the master switch; It will stop entire control network if the Stop Pb switch is pressed. The main contactor should work with both the star and delta contactor. The main contactor should control the timer coil from the action of its NO Auxiliary contact. It's the timer's duty to switch between the Star and Delta contactors with its NC and NO contacts respectively with the set time.
@leonardchinonso7067
@leonardchinonso7067 Жыл бұрын
Pls. Can you do a video on electric motor rewinding
@odonggeorgerackara4885
@odonggeorgerackara4885 7 ай бұрын
Does it also apply to transformers
@muradzeynal
@muradzeynal 2 жыл бұрын
sir, why did you use that H switch, i couldn't quite catch that. My point is that if there is main auxiliary, what is the reason for using H switch?
@jmajuta2963
@jmajuta2963 2 жыл бұрын
The H aux is to hold the timer and the m contact is to hold the main contactor
@nevermajola4402
@nevermajola4402 2 жыл бұрын
Remove normal open on the main that can make your circuit simple main and star can start together you just confused lot of people but pose uncessary normal open on Main
@zakariaabdi2316
@zakariaabdi2316 3 жыл бұрын
Teacher thanks for video 🙏....but sir if possible I need circuit connection please
@electreca1
@electreca1 3 жыл бұрын
That circuit i drew on the board is CONTROL CIRCUIT for star delta stater, unless you need a power circuit. you can find it here electrecasolutions.com/understanding-star-delta-starter/
@zakariaabdi2316
@zakariaabdi2316 3 жыл бұрын
Thanks Teacher
@ongomsamuel2896
@ongomsamuel2896 2 жыл бұрын
They gave us please but he can do it again
@prospermuvadi589
@prospermuvadi589 Жыл бұрын
now l have picture
@johntamrang9139
@johntamrang9139 6 ай бұрын
hello David. can you pls do a video on how to connect a 3phase ats signal cable to amf25 pls
@electreca1
@electreca1 6 ай бұрын
Will plan, thanks for watching
@vikaspaswan5099
@vikaspaswan5099 2 жыл бұрын
I am electrical engg
@user-uo1fr4sm1i
@user-uo1fr4sm1i Жыл бұрын
which of the connection is that'
@electreca1
@electreca1 11 ай бұрын
Kindly ask your question again.
@FonchamSandra
@FonchamSandra Жыл бұрын
Hi
@FonchamSandra
@FonchamSandra Жыл бұрын
Teach me
@sammynyadero7495
@sammynyadero7495 Жыл бұрын
How do we connect a timer without coil
@electreca1
@electreca1 Жыл бұрын
What kind of timer is that?, timers wether digital or analog have got a coil. Thanks for watching.
@sammynyadero7495
@sammynyadero7495 Жыл бұрын
@@electreca1 Thank you for your response. The timer has only NO and NC
@fredngoma1657
@fredngoma1657 2 жыл бұрын
What's the purpose of the timer???
@electreca1
@electreca1 2 жыл бұрын
The function of the timer is Delay. Example, if a generator starts, the timer will delay until attain its full speed(RPM) then the timer can load the generator.
@mbangupaules5972
@mbangupaules5972 Жыл бұрын
Where is the CB in your circuit
@electreca1
@electreca1 Жыл бұрын
My bad! I did not indicate it, but it should definitely be included the circuit.
@mianmudassar2365
@mianmudassar2365 Жыл бұрын
Sir Urdu translation bi kar dia karain
How to wire a float switch to a well pump
11:02
ELECTRECA
Рет қаралды 104 М.
Star Delta Starter Control Wiring Explained Practically @TheElectricalGuy
13:31
LOVE LETTER - POPPY PLAYTIME CHAPTER 3 | GH'S ANIMATION
00:15
That's how money comes into our family
00:14
Mamasoboliha
Рет қаралды 8 МЛН
Пробую самое сладкое вещество во Вселенной
00:41
Wait for the last one! 👀
00:28
Josh Horton
Рет қаралды 150 МЛН
forward reverse switch wiring
7:26
ELECTRECA
Рет қаралды 50 М.
Star Delta Starter Power wiring Explained Practically by @TheElectricalGuy
13:13
star delta starter connection 3 phase | ELECTRECA
25:03
ELECTRECA
Рет қаралды 67 М.
Star Delta Control Circuit Wiring Explained | Animated | Easy
10:38
Baz Controls
Рет қаралды 3,3 М.
The Beginner's Guide to Wiring a Star-Delta Circuit
5:29
Factomart Singapore
Рет қаралды 47 М.
LOVE LETTER - POPPY PLAYTIME CHAPTER 3 | GH'S ANIMATION
00:15