@--harry_
@--harry_ 2 жыл бұрын
I had an intermittent issue with my personal oil boiler, it would fail every week late at night on the coldest day. I would clean nozzle, points, check oil pressure and she would start right up. Only to fail again another night. One night I was pissed and came down and kicked it again it started right up. It was a relay on the control, cracked solder joint. I soldered it that night and it's been good for 10 years since.. Hate intermittent issues they make you loose your cool sometimes...
@timothyoneill3154
@timothyoneill3154 2 жыл бұрын
I ran into the same thing on mine. Transformer on control board had bad solder connection. Resoldered and haven't had any problems since.
@scotthaley8694
@scotthaley8694 2 жыл бұрын
That's exactly what I think the problem is, the soldered terminals where the relay is connected to the aquastat board. that relay snaps in rapidly cracking the solder over time. I've seen this many times.
@beernutsonline
@beernutsonline 2 жыл бұрын
Had the same cold solder joint problem on my Audi's main engine ECU relay, always running fine when cold or hot, and lots of missing in between. Finally found the relay after _lots_ of fault search, and it's been great since! Hate cold solders, but they're always a blast to finally fix! :D
@J-Colt
@J-Colt 2 жыл бұрын
Jail a/c where I work would periodically go into free cooling mode even though it is not set up with free cooling (option on motherboard) Turn off power then back on. It would sometimes run 2 to 6 weeks and sometimes it would go back into free cooling before I even got home. I had tech out several times over a 2 year period. I called owner one day and asked if he could take a look at it. He was semi retired at the time but a top notch tech. We turned unit off and back on and waited for time delay. Unit kicked on and we heard a arc sound. No.1 fan stopped and went into reverse , tripped on high limit and went into free cooling. Found a wire that had a tiny nick in it and it would occasionally make contact with metal bottom. Fixed that and all has been good. That was the first time it had done that while standing there. It sometimes did it several times in a month and other times every other month or so. Great vid Steven!
@jefferygrady3181
@jefferygrady3181 2 жыл бұрын
Alot get the money and run out there! Guy won't answer now! You have to see through hard repairs because you learn from them and it makes your job easier in the long run! Great trouble shooting as usual Steve!
@homeytoyer8303
@homeytoyer8303 2 жыл бұрын
Good hearted and honest repair technicians are rare. This guy is awesome! Puppy is wonderful too!
@joeylawn36111
@joeylawn36111 2 жыл бұрын
Bad wiring connection. Could have also been a cracked solder joint that holds the wire terminal to the circuit board.
@jeromewhelan6723
@jeromewhelan6723 2 жыл бұрын
Right! When I saw him remove the probe pressing against the printed wiring board and heard the motor stop, I was also thinking of a cracked printer wiring conductor path on the PWB near the probe point.
@rickdavis2048
@rickdavis2048 2 жыл бұрын
Hey Steve. Love your vids. I worked in avionics and had a similar problem. A unit was intermittently losing power. I would put my voltage probe on a terminal on a circuit board and the unit would power up. Took the probe off and would lose power. Found that the circuit card had a cracked run on the back. By taking a reading on the terminal, the pressure from me holding the probe on the terminal was causing the crack to close up and making contact, allowing power to resume. Oh what fun electronics. You do great troubleshooting and diagnosing.
@chrisconnaughton5085
@chrisconnaughton5085 2 жыл бұрын
Bingo, exactly!!! Cracked circuit board trace, and this can be caused by overtightening the lugs on the backplane. So gotta be careful not to overtighten.
@michaeltobias3524
@michaeltobias3524 2 жыл бұрын
You are correct. I had that exact aquastat with the same problem. It had a bad solder joint on the relay. Just resoldered and was good.
@loft306
@loft306 2 жыл бұрын
That’s what I was thinking, just the way you put pressure on the Circuit board it was acting like the traces were delaminating and/or a failed solder joint.
@williamjeffrey1222
@williamjeffrey1222 Жыл бұрын
Solder on the in the back of the circuit board had a crack in it . Which would give an on off reaction when pressed or looped . Because it only made an electrical loop with a jumper wire applied . Chances are the component will need to be replace to stop the error .
@user-jd6ch3ny1g
@user-jd6ch3ny1g 6 ай бұрын
You were making a circuit with your meter connnecting it basically feeding it power
@b.powell3480
@b.powell3480 2 жыл бұрын
Hi Steve, what fun your having ! All these limit sensors are daisy chained together ! Ran into a similar problem with a natural gas furnace years ago, turned out to be the high limit sensor was intermittent!!, funny thing is that the rest of the crew in the shop couldn't figure it out and gave up ! Boss wasn't too happy with them, but my work partner and I were able to find the problem and fix it ! Great video
@crbradbury8282
@crbradbury8282 2 жыл бұрын
Nice!!
@SEDAZ01
@SEDAZ01 2 жыл бұрын
If it comes back in again check the back of that controller board for cracked solder joints.
@jeffweber8244
@jeffweber8244 2 жыл бұрын
Yes. I came to comment the same thing. The symptoms were consistent with a cold solder joint. Pressing on the board with his probe flexed it enough to restore contact for a while. Lead-free solder and vibration make this problem more common.
@milotorres6894
@milotorres6894 2 жыл бұрын
With vibration brittle solder is more problematic for board connections or in itself ,🤔👍✌️💎
@bobhayes1333
@bobhayes1333 2 жыл бұрын
Good golly ! Miss Molly ! Love that puppy. Once Steve sent me out to his truck to grab a couple filters for my attic unit. He didnt tell me about the (loud and protective) chihuahua he had at that time. Scared the living crap out of me. It was hilarious ! He's the best.
@shanechis
@shanechis 2 жыл бұрын
Great video Steve! You kept at it and didn't give up after 4 hours. Well done!
@rickdejesus3517
@rickdejesus3517 2 жыл бұрын
Great job! You’re the man especially with oil fired equipment.
@10minutenewhampshirebreak77
@10minutenewhampshirebreak77 2 жыл бұрын
I’m glad I’m not the only one who runs into this shit sometimes!
@kylecarman4809
@kylecarman4809 2 жыл бұрын
Great call. Awesome homeowner and some great education. Thank you for everything you do.
@craigharding475
@craigharding475 2 жыл бұрын
This video was full of useful info.!! I am having a similar problem with my furnace, thanks! That controller with the diagnostic readout was amazing! I did not know they existed.
@heavydiesel
@heavydiesel 2 жыл бұрын
Interesting vid Steve! Had an interesting one years ago, milk cooler would cut out, no display, by the time we got there it was working again, turned out the sun was shining through the window and warming the controller up which had a bad solder joint! Took a few visits to find.
@stevenlavimoniere
@stevenlavimoniere 2 жыл бұрын
hello heavydiesal hope your doing well my friend
@heavydiesel
@heavydiesel 2 жыл бұрын
@@stevenlavimoniere Doing ok thanks!
@steveneumeyer7926
@steveneumeyer7926 2 жыл бұрын
what i was thinking when when he kept moving his probe
@priestblood
@priestblood 2 жыл бұрын
I thought cold solder joint too,worth pulling board out and running soldering iron over wiring before relay as I hear it click off so power loss so try circuit before relay
@phogol
@phogol 2 жыл бұрын
Im a factory rep for a refrigeration manufacturer and we have several controllers that will blank a display when there is a short connected to the controller. Usually it's a thermistor, but sometimes it's the condenser circuit or a loose neutral. Danfoss is notorious for doing this. You can test this by leaving only L and N hooked up and if that's the issue, the screen will turn back on. I see this a lot. Did you actually open the control, thats a lot further than most techs would do. They usually just tell me its "broke" lol.
@dreonwhuds313
@dreonwhuds313 2 жыл бұрын
Steve can fix anything and cooks a great stew too!
@dangates3022
@dangates3022 2 жыл бұрын
he likes snappa soup lol you tube captions go crazy trying to type what he is saying love the guy and his videos glad hes you tubing
@leslieharlan1730
@leslieharlan1730 2 жыл бұрын
Thank you for all your HVAC videos its helping me in school
@JohnnyCab
@JohnnyCab 2 жыл бұрын
Loose electrical wires can be a nightmare or a loose connection on the circuit board . Good job Steve and miss molley
@somap8380
@somap8380 2 жыл бұрын
Steven, you fix things as well as teach the customers. Great. 👏🏾👏🏼👍
@grandlarceny211
@grandlarceny211 2 жыл бұрын
This guy is a real mechanic!!!! Top notch. Great job as usual Steve....
@rossflores4394
@rossflores4394 2 жыл бұрын
I believe that you were losing a neutral in your motor supply whip. Great troubleshooting Steve. Yous the man.
@nickc7494
@nickc7494 2 жыл бұрын
Great video, worked on cars a long time , learned how to work on my boiler from watching my plumber, next time check for continuity I was thinking of a short when I saw the voltage drop.
@Robnord1
@Robnord1 2 жыл бұрын
I really hate intermittent equipment problems. Willy nilly parts swapping and having some customers think it's amature day is no fun mamma!
@biker55555
@biker55555 2 жыл бұрын
In such instances I do my best to educate the consumer and they either get it or they don't. Nothing more one can do. We're not magicians or gods, just human :)
@mrwendell4564
@mrwendell4564 2 жыл бұрын
Oh man you described it perfectly!
@kevinsavard5998
@kevinsavard5998 2 жыл бұрын
Electronic transformers were supposed to be the bomb. Yeah right one leg dies intermittently and drives everyone up a tree. Sometimes the old school ones are better, because when they get weak they die no guesswork.
@steveneumeyer7926
@steveneumeyer7926 2 жыл бұрын
can not fix what is not broken at the time. that's why i tell people to take video
@danwittels5542
@danwittels5542 2 жыл бұрын
Intermittent electrical problems are the worst, gaint time suck, but it feels good when you finally figure it out. Way to stick on it!👏👏👏
@walterb299
@walterb299 2 жыл бұрын
Most electrical problems are easy, its finding the problem is the hard part and as an electrician for many years I find that they never just go away it always comes back.
@marcoselgaucho1106
@marcoselgaucho1106 2 жыл бұрын
These are the types of calls that piss you off but make you feel good once you figure it out. I’m a super tech feeling🤣
@edic2619
@edic2619 2 жыл бұрын
Thank you very much for the great video and you sharing you decades of skill with all of us. Great job.
@tonym6920
@tonym6920 2 жыл бұрын
Hey Steve and Miss Molly! Workin’ again y’all. 👍👍. Nice piece of detective work Steve, great job!
@timsr.6706
@timsr.6706 2 жыл бұрын
Thanks for another great video !!! When in doubt, call Steve out !!!
@billiamc1969
@billiamc1969 2 жыл бұрын
WOW...Mr Steve is a true technician
@i.r.wayright1457
@i.r.wayright1457 2 жыл бұрын
That was interesting alright. Now, how would you like to troubleshoot an autopilot on a twin engine airplane? BTW, I learned enough for you to install a mobile home furnace in the second floor of my workshop, blowing down through the proper mobile home base. Then, when I had trouble keeping it running I found out about a tiger loop from you. My oil tank is at the 8-9 foot low limit on the first floor level. Ever since I installed the loop, it has been working flawlessly. I can change, adjust or troubleshoot any part of the system after your informative videos. Thanks Steven, from central PA.
@coldfreon2077
@coldfreon2077 6 ай бұрын
Steve is proud of himself, can hear it in his voice. Good job buddy!
@bobparrott8130
@bobparrott8130 2 жыл бұрын
Steve nice job.... If happens again I'd replace that honeywell controller 👍
@Hubjeep
@Hubjeep 2 жыл бұрын
This was like me diagnosing my outboard engine. Went through all sorts of electrical, ended up the carburetor needle seat vibrated loose in one of the carbs. Sprayed gas in the carb and the boat took off!
@brianbergren8134
@brianbergren8134 2 жыл бұрын
Thanks for the insight Steven, I got backed into a corner with this gas boiler a Friend came out and said you need a vent damper. Well okay I'll give it a shot looks easy set it up and it closed never to open. So after a few days when my feet were icicles, I went down and traced the wires I pushed on the black wire inside the aqua-stat suddenly the vent damper open and the burner fired. So yes I put on my Hawaiian shirt and made a Pina-colada. Loose wire was the problem! Watch out for loose wires and loose woman and everything will be fine Thanks for the video's The Skulmonkeyz 🤣
@CharlesM-dp4xe
@CharlesM-dp4xe 2 жыл бұрын
Yeah, definitely a good one. It's a good thing ya stuck with it till the end, that's what it takes. We all know some have limits, they get scared cause they think its gonna be too much work and the customer won't pay and all so they bail before they get too deep in the hole. You called the bluff, good call ! Good job, I hope its not haunted .
@Fireship1
@Fireship1 2 жыл бұрын
Intermittent things are easier to fix when they stay broken!
@whyarentumadbro
@whyarentumadbro 2 жыл бұрын
Than they wouldn't be called intermittent, would they...
@63jeepj20
@63jeepj20 2 жыл бұрын
No joke, ive got 2 intermittent issues with my truck. Wipers sometimes run until they decide they are finished and i have a completely random misfire when going 60+ mph.
@ESDI80
@ESDI80 2 жыл бұрын
Could be a cracked solder connection on the circuit board causing an intermittent. That would explain the odd voltage drops you were seeing.
@robinvater3067
@robinvater3067 2 жыл бұрын
Yes , I agree.
@madusan1
@madusan1 2 жыл бұрын
Aka cold solder joint. I am a electronics tech for over 30 years. Course could also be an intermittent short in wires to control.
@jblyon2
@jblyon2 2 жыл бұрын
@@madusan1 Cold solder joints...they'll bite you in the ass every time. Just a matter of when.
@khx73
@khx73 2 жыл бұрын
Yup
@flash490
@flash490 2 жыл бұрын
yes pull the board and reflow the connections this has happend to me,
@danielhowiesr.2593
@danielhowiesr.2593 2 жыл бұрын
Steve, it might be that the power from the circuit breaker is intermittent. The stabs on the breaker might be loose or burnt on the panel buss. Check the breaker connection. Good luck!
@tomdale1313
@tomdale1313 2 жыл бұрын
these kinda things separate the good from the next level mechanics...txs for sharing
@josephbradshaw5353
@josephbradshaw5353 11 ай бұрын
You are a real class act Steve, if I ever could pick a father it would be you.
@johnsmith7676
@johnsmith7676 2 ай бұрын
Yeah, a "class act" that constantly drops f-bombs and such in front of all his customers. SMH
@pdsrenos
@pdsrenos 2 жыл бұрын
Always impressed at the great work that you do!!
@Eddy63
@Eddy63 2 жыл бұрын
This was a good learning tool ... Good troubleshooting ... Thx for sharing ...
@mikeinpenna
@mikeinpenna Жыл бұрын
Hi Steve, watching this video reminded me of the same problem I had with a new heater I had installed 7 years ago. one day the heater stopped working, turned out to be a bad connection in the same wiring you had. If the cable was hanging down just a little the system would shut off. I had to zip tie the bx cable up to support it. The guy who installed the system said he has had problems with the same cable. Said he would come back out and fix the problem, asked him many times to replace the cable, never came back. after 7 years the zip tie is holding the cable in place and it works. Never again referred him to anybody.
@WeatherNut27
@WeatherNut27 2 жыл бұрын
Thanks for filming, editing, & uploading as usual! We appreciate it. Interesting job and nice work! Loose electrical connection can be a headache to figure out. Loose neutrals can be a bitch and dangerous too.
@watermanone7567
@watermanone7567 2 жыл бұрын
Check the breaker going to the burner. Good fix I hope, Thanks for great video's.
@flagstaff866
@flagstaff866 Жыл бұрын
Love your invaluable troubleshooting , talking to Miss Molly and you swearing with your New York accent.
@tedwilliams8766
@tedwilliams8766 Жыл бұрын
one of my favorite vids from steve. if im trouble shooting anything, i check connections first and do some wire wiggling. it may take a little longer but its cheaper than firing the parts cannon plus then you know you got the problem fixed.
@dustyflair
@dustyflair Жыл бұрын
anyone who doesnt test first and just starts changing parts is an idiot.
@robertgerber2533
@robertgerber2533 Жыл бұрын
Great video. You pretty much went through the whole chain of controls to find out the problem. Very good reference video
@ronsbeerreviewstools4361
@ronsbeerreviewstools4361 2 жыл бұрын
I like the way your posts start, from the perspective of your truck driving thru streets of Buzzard bay cities and towns, cheers !
@billmea5593
@billmea5593 2 жыл бұрын
I’m not gonna charge you for this labor, or for this. Customers like, geez buddy I don’t think you should charge me anything, you’ve replaced every part and you still don’t know what the problem is. This is what we call Grasping for straws diagnosis.
@brianwood5220
@brianwood5220 2 жыл бұрын
Sometimes it takes persistance to work through each thing in turn. Great job. Thanks for sharing.
@samfisherv30
@samfisherv30 2 жыл бұрын
Chasing electrical problems sucks. Nice job, Steve!
@richardelushik1177
@richardelushik1177 2 жыл бұрын
Nice troubleshooting. That saved you on this one. Good work.
@williamdyckman9704
@williamdyckman9704 2 жыл бұрын
Steve, really interesting problem, takes lots of experience to find the source of the problem !
@videomentaryproductionschannel
@videomentaryproductionschannel 2 жыл бұрын
Nice to see a proper old school gas engineer who knows how to trouble shooting a problem, nice job mate.
@marks.4388
@marks.4388 2 жыл бұрын
That was a heck of a job. Man you can do it all.
@GTCGreg
@GTCGreg 2 жыл бұрын
You'll be back there. No way was that intermittent problem caused by the wire going from the limit switch box to the burner. You were measuring the voltage at the feed end of the wire and it was dropping out there, how could it be the wire causing the problem? It's pretty obvious that the problem is an intermittent connection in the limit switch box because when you would make physical contact connecting and disconnecting your meter, the voltage would come and go. The problem is most likely a bad solder connection on the backside of the circuit board in that box. Probably the connection where you were connecting your meter.
@gailtaylor1636
@gailtaylor1636 2 жыл бұрын
Yep. Worse thing ever is trying to fix an intermittent issue while somebody looks over your shoulder. I was surprised he didn't do electrical checks before replacing any parts. Likely nothing was wrong with the pump. Was only getting power intermittently too. He DID find several minor issues with loose connections though.
@nicholasbeck7670
@nicholasbeck7670 2 жыл бұрын
Yep, good observation -- meter probe pressing on the hot contact in the limit switch box and then line voltage drops out when probe removed. Probably that ckt board / weak solder joint.
@andydelle4509
@andydelle4509 2 жыл бұрын
Electronic tech here. I'll also bet it's a cracked solder joint where that terminal solders to the PC board or something else on the board has a bad solder joint. Or it could be a cracked copper trace on the board. Either one is easily repairable but time is money so I would understand just replacing the entire limit control.
@GTCGreg
@GTCGreg 2 жыл бұрын
@@andydelle4509 Yeah, I agree. I'm just surprised he didn't catch that. But then, there are so many aspects to HVAC servicing, you can't be an expert on everything. None the less, I've learned a lot from Steve's videos.
@andydelle4509
@andydelle4509 2 жыл бұрын
@@gailtaylor1636 Steve is highly competent but we have all had one of those days where we totally miss the obvious. And with what he went through there, we'll cut him a break!
@johnc4876
@johnc4876 2 жыл бұрын
Great job troubleshooting !
@djs_projects_repairs
@djs_projects_repairs 2 жыл бұрын
Good deal I figured you would get it done. I've learned a lot from your videos and stuff good one man.
@dell177
@dell177 2 жыл бұрын
i worked on broken equipment for 50 years and some of the stuff you see is bizarre. I once had an intermittent problem and it was a lug that was crimped on the insulation at the factory, not the bare wire. It worked for months but as it aged the crimp got just a bit weak and it lost contact with the wire, strip the wire end and a new lug and life was good. Another good one is the wire that goes but never gets there, it's a wire defect where there's a tiny gap in the wire conductor under the insulation. Moving the wire can make it come and go, replace the wire and all is good. And then there is the cracked solder joint that can drive you nuts. BTW KZbin is going crazy with ads - good way to drive people away.
@gailtaylor1636
@gailtaylor1636 2 жыл бұрын
I spend more time watching KZbin than TV & sleeping. So the 11.99 for no ads is worth it for me.
@dalltex
@dalltex 2 жыл бұрын
Real world type of situation. Glad you got it solved. Many would give up due to frustration.
@khx73
@khx73 2 жыл бұрын
Like someone else said in the comments, I bet it's a cracked solder joint on the back of that control board. Slight temperature variations, vibrations, touching the board with meter probes .. all makes sense. One minute with a solder gun would fix it right up if this is the case.
@anthonyoconnell9389
@anthonyoconnell9389 2 жыл бұрын
Great job well done for sticking with it ☘️🥃💚👍
@billsmith2212
@billsmith2212 2 жыл бұрын
Great fix . Some really good comments on cracked circuit boards , bad or cracked solder joints . I hope your friend spreads the " good word " about the OTHER plumber . He has a fantastic business model - I am an " expert " . I am 100 percent sure what's wrong . Change a part ( did he CHECK it first ? ) and then then NEVER answer the phone when it DOESN'T work ! I guess his BIG TOE " guage " - meter wasn't working too well that day . And I bet the truck says " Master Plumber " on it ! Spread the good word .
@sirkllr
@sirkllr Жыл бұрын
It makes you feel really good when you work on something that everybody else worked on that nobody could make work but then you step in and make it work 😃
@TeePeeB
@TeePeeB Жыл бұрын
Outstanding! Thank you.
@biker55555
@biker55555 2 жыл бұрын
Under normal operation with lack of air entering into the tigerloop, its lower chamber will fill up with oil and when air enters via the feed line the lower chamber will drain.
@vulcanphil2351
@vulcanphil2351 2 жыл бұрын
These calls are the toughest Steve is one excellent tech. He made me a better tech. Next level.
@jenklingler8169
@jenklingler8169 2 жыл бұрын
guaranteed crack in a solder joint on the back of the aquastat! Had a brand new one crack when tucking the wires (heavygauge) in to put the cover on...what a nightmare!! But once you've seen it, you recognize it fairly easily the next time
@xdrag4854
@xdrag4854 2 жыл бұрын
Nice to see that you are a true tech. Good job understanding the system and tracking down the problem. Lot of guys would of just replace everything.
@natekry
@natekry 2 жыл бұрын
True tech would have track the problem down before replacing everything. SMH
@022367ASM
@022367ASM 2 ай бұрын
I like these long videos. Great job diagnosing!
@paulmea3166
@paulmea3166 2 жыл бұрын
My newer steam boiler had a wire problem between the low water cut out and that relay box. The solid core wire had a nick in the insulation. Took we quite a while to figure that one out... Intermittent problems...
@Albrecht8000
@Albrecht8000 2 жыл бұрын
Steve is the heating Superman! Greetings from germany
@stevenlavimoniere
@stevenlavimoniere 2 жыл бұрын
hello
@milotorres6894
@milotorres6894 2 жыл бұрын
Boiler whisperer , nice troubleshooting protocol strikes again , 💪🔥👍🤔✌️😔💎🤙
@chekaphski
@chekaphski 2 жыл бұрын
Hi, Gas registered gas engineer from the UK here. What I see is a dry solder joint on the back of the printed circuit board which connects the screw connector. I've had a few of these, more often when a higher current passes through the joint. Regards from the UK.
@nathanielreid4967
@nathanielreid4967 2 жыл бұрын
You fought the monster and overcame👍👍👍 Sometimes dry joints at terminal can cause similar symptoms
@671chevelle671
@671chevelle671 2 жыл бұрын
I had the exact same problem, with the exact same burner and transformer, it would run perfect for a few weeks, then lockout, hit the reset and tap on the transformer (new less than a year old, came with new burner) and it would fire up for a few more weeks. Replaced transformer problem solved. At first they thought cad cell, and replaced it which didn't fix it, but my service guy is really good and figured we'd try that first before the transformer, being an intermittent problem I couldn't make it fail when he had time to come out, and of course it was in the middle of winter and couldn't leave it off, mama don't like the cold.
@cornbreadburgess1950
@cornbreadburgess1950 2 жыл бұрын
Nice job Steve,see you soon on next one.
@vyger6336
@vyger6336 2 жыл бұрын
I used to hate calls like this. Leave the house Boiler is running fine and an hour later customer calls and says "I got no heat again " ...DAMN !!!
@randybearor6650
@randybearor6650 2 жыл бұрын
Like watching your post about the oil heater from hell. Look forward to more posts. Lov=d your little helper doggie, so cute.
@bullmoosepiper7732
@bullmoosepiper7732 2 жыл бұрын
Class act Steve. Taking care of that guy and not killing him on labor. This is the type of situation that not only is the right thing to do, but will earn you a loyal customer for life who will tell his friends and family about your integrity and professionalism. Young techs should take notice of this, because this is how its done.
@TheRubtastic
@TheRubtastic 2 жыл бұрын
I'm a new (not young lol) tech and I'm paying close attention. This fella clearly knows what he's doing.
@glorifiedg9582
@glorifiedg9582 2 жыл бұрын
@@TheRubtastic knowledge is power. If you could diagnose and fix anything you make more money because you are worth it.
@crbradbury8282
@crbradbury8282 2 жыл бұрын
Agreed. I see a master veteran tradie in the flesh. I'm a carpenter that's been around. Guys like this.. Are a Rare breed and great to watch and learn from.
@davidfeldbauer7970
@davidfeldbauer7970 2 жыл бұрын
Not unusual for tiger loop to go full if there is no air in system and the tank is above oil burner. Gravity feed systems will always fill tiger loops. Oil safety valves will stop that from happening.
@davidfeldbauer7970
@davidfeldbauer7970 2 жыл бұрын
Also, watch tiger loop video. Tells you is ok to run with bottom bowl full of oil.
@markw2266
@markw2266 Жыл бұрын
I had that same problem on my boiler limit contol, and it was a bad solder joint on the back of the board. I think I replaced it just because I had no faith in the part anymore. If I remember right it did some damage to the relay for the burner.. I remember checking it with a meter and it would work just like he had. Definitely a suck call. As for the wire theory...completely plausible.. I had a piece of wire open mid length in a covered conduit. I only found it because it failed long enough to find it. Depending on how you moved the wire it would make up again. Between the two possibilities, the solder joint would seem more likely. Time will always tell. Thanks for the content, I've learned a lot about burners.
@DAS-Videos
@DAS-Videos 2 жыл бұрын
There was a gremlin in the works. You did that customer good.
@manolotech1110
@manolotech1110 2 жыл бұрын
Intermittent problems really test your patience, but also are the most interesting learning experiences. Great vid Steve 👍
@mjg263
@mjg263 2 жыл бұрын
Cracked solder joint on the controller board is my guess, had the same thing happen on mine. Re-traced the solder connections at the relay and it’s been fine for years. I’ve found the same problem on other controller boards too, usually right at the relay pins.
@95Sn95
@95Sn95 2 жыл бұрын
You are pretty knowledgeable I'm always impressed and you seem very honest unlike some. I'm from Maine and blue collar working Joe so I know i have some typical mainah accent but that wicked Maaass accent cracks me up it's wicked heavy! Lol. Just messin around. Keep fixin peoples friggin boilahs it's gettin friggin cold out!
@iancampbell582
@iancampbell582 2 жыл бұрын
You will only see movement in the Tigerloop if theres air.
@Dave52732
@Dave52732 2 жыл бұрын
Cold solder joint on the board connection that was getting probed by your black lead @ 49 minute mark. Cold solder joints are intermittent as hell, and can cause callbacks. You had positive cause and effect when you were probing the connector, when you applied pressure through the probe the connection was positive, removing the probe caused it to be flakey. Resoldering that board connector would be a decent repair, or replace that limiter board altogether.
@priestblood
@priestblood 2 жыл бұрын
Am a new subscriber and like your channel, Thanks for sharing your life as a engineer,I also heard relay click so my guess as a electronics engineer Is check board for failing pcb solder joints as thermal temperatures will cause pcb board flex and dry soldering joints .Hope it helps when you go back
@mattbauckman9907
@mattbauckman9907 2 жыл бұрын
That model aqua stat has a higher fail rate than most others in my experience. I’ve had them fail and keep running wild making steam popping relief. Not cool.
@robbierego1616
@robbierego1616 Жыл бұрын
I worked that dude in the back round for years back in the day.learned alot from him.good dude.small word.
@greggaieck4808
@greggaieck4808 2 жыл бұрын
Steven lavimonier you do a great job fixing heat and ac
@peteraitken6494
@peteraitken6494 2 жыл бұрын
Hi Steve catching up on your vids been working away from home Jesus that one was a nightmare knew you would figure it out always hard when its intermittent fault like that plays with your head for defo take care mate and all,the best from me in Scotland 👍👌👌🔧🔧🔧
@atlasfueloilinc.2421
@atlasfueloilinc.2421 2 жыл бұрын
Parts today are not reliable. When boiler lit off you had oil in chamber so I found the best to do is reset boiler with peep site open When boiler lights off count to 5 and shut off look for after burn from missed ignition. These new igniters are not transformers and suffer from intermittent fails, new igniter solves problem. Good video
@michelgrenier1878
@michelgrenier1878 2 жыл бұрын
When the voltage changes , Sometimes it's the contacts in the controls and relays that are bad , If the contacts are black they are shot and there is resistance across them .
@nmccw3245
@nmccw3245 6 ай бұрын
Damn Steve, that was a tough one. Intermittent issues are the worst to diagnose and repair.
@TechnMoto
@TechnMoto 2 жыл бұрын
Good work Steve. 👍
@freak6042
@freak6042 2 жыл бұрын
Those primaries are great. Those are pretty much all I use. They can take most guesswork out and show you exactly what's going on. They are so universal.
@jeffreykubiak5126
@jeffreykubiak5126 2 жыл бұрын
Multiple offenders are tough had one on a Bryant furnace gas two days ago. Thanks Steve
OLD GAS FURNACE NO ONE CAN GET IT RUNNING
37:26
steven lavimoniere
Рет қаралды 255 М.
OIL BOILER FULL OF BLACK SOOT SUNDAY SERVICE CALL
38:01
steven lavimoniere
Рет қаралды 99 М.
Я обещал подарить ему самокат!
01:00
Vlad Samokatchik
Рет қаралды 9 МЛН
Smart Sigma Kid #funny #sigma #memes
00:26
CRAZY GREAPA
Рет қаралды 2,7 МЛН
A simple water heater is more clever than it seems
22:52
Technology Connections
Рет қаралды 1,9 МЛН
most neglected  job i have seen in 35 years
21:32
steven lavimoniere
Рет қаралды 144 М.
Homeowner Tries To Fix Gas Boiler and Fails Miserably How to Bled or Purge Zones
31:54
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 114 М.
HVAC Scam failed again on 2nd opinion call
18:59
Anti DIY HVAC
Рет қаралды 134 М.
THEY THINK THEY HAVE A FEW AC'S NOT WORKING
37:41
HVACR VIDEOS
Рет қаралды 269 М.
Williamson Gas Boiler Isn’t Heating Properly Step by Step Plumbing & Heating Service Call
52:47
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 26 М.
major water leak from first floor toilet
49:23
steven lavimoniere
Рет қаралды 18 М.
Oil Heat 🔥 Boilers - How it works - Understand the Basics
22:18
Silver Cymbal
Рет қаралды 650 М.
Chinese School System - Teaching Children Humanity ⬆️
0:16
The Art of Happiness
Рет қаралды 10 МЛН
Света квадробер в парке! Часть 4 #shorts
0:31
Настя AmyMyr
Рет қаралды 939 М.
Ăn trái gì thế/kỳ kỳ tv & Family #shorts
0:13
Kỳ kỳ tv & Family
Рет қаралды 15 МЛН
я,когда приехала к бабушке #shorts
0:12
Kamilla Family
Рет қаралды 1,7 МЛН
Bizda +50☀️ Subscribe❤️
0:14
Hayot Sinovlari
Рет қаралды 4,9 МЛН