Code 20 is "twinning fault" which refers to conflicting thermostat signals, e.g. heating and cooling calls at the same time. In this case, the conflict was being generated within the board itself.
@brianburns72113 ай бұрын
Jumping TT proved that.
@DennisBuckley-yd6cl13 күн бұрын
Nice job as always Steve!
@Gman29303 ай бұрын
Hey Steve, great diagnostics!! There is a lot of parts changers out there, but actually finding the issue makes you have all your repeat customers. Plus honesty, that’s a big one!!
@francisbriggs762 ай бұрын
Steve, you would enjoy a magnetic light when working on furnaces etc!
@DAS-Videos3 ай бұрын
Miss Molly sporting her very warm looking outfit is working again.
@Salvadorbalihai2427 күн бұрын
Amazing service call. We're not worthy, We're not worthy.
@chuckyc6912Ай бұрын
Steve you are the best. Keep up the interesting videos.
@jeffdickens70193 ай бұрын
Good job Steve you always figure it out you and Molly take care
@SkilledLabor17 күн бұрын
Whoever installed that furnace doesn’t know what they are doing. Throwing the air handler filter which is 16 by 20 on a 92% 100k furnace with a 5 ton drive! Should have a 6” box on furnace, with a 20 by 25 filter! Nice work Steve!
@CarreraTrackOntheFloor2 ай бұрын
What make of furnace was this repair?
@DoruStancu2 ай бұрын
Good call Steave.
@andylowe27253 ай бұрын
Maybe use the chrome colored anti static bag, by splitting it open, and draping it over the new circuit board. Keeping future moisture off the connectors.
@themayorofairconditioning28683 ай бұрын
Great video. Great time of year for driving around
@JakePorterHVAC3 ай бұрын
Nice repair man. Error code 20 "TW" is a Twinning Fault. The furnace control board was thinking that it was set up to twin with another non-compatible furnace, so it wouldn't fire off. Don't see that one everyday. Thanks for the video and stay safe out there.
@picklerix61622 ай бұрын
I wonder if something is holding the twinning signal high or low, causing the fault? Obviously, the microcontroller thinks that the furnace is twinned with another furnace.
@robertblacksmith43553 ай бұрын
Mom's furnace was built 1980 just changed the blower motor after 44 years no circuit board 😊
@ClickinChicken3 ай бұрын
wow, nice job!
@andylowe27253 ай бұрын
I love the Old, RELIABLE FURNACES AND A/C SYSTEMS
@Brian_5413 ай бұрын
They definitely don’t make them like they used to.
@chrisjnoe20203 ай бұрын
Excellent repair
@tjh_89133 ай бұрын
Thanks for the reminder to change my own filter! Yeesh!
@zekenzy64863 ай бұрын
Great video. Thank you for sharing
@iamnoone.3 ай бұрын
Howdy Steve and Miss Molly
@porky77533 ай бұрын
Steven, get the ole snowblower ready.
@JamesAgans3 ай бұрын
The first thing I would do is jump 120V AC to that inducer motor eith an extension cord. If it runs id check the vacuum switch, the vacuum port, and the condensate trap. Anybody else see those water traces below the base of this unit? Look right below Steve's drop light.
@spacemanwithraygun39333 ай бұрын
I wish I had the money to buy you a decent Nitecore headlamp.
@FixItRight033 ай бұрын
Rubber gloves, acting ground 🎃🎃🎃🎃🎃🎃🎃🎃🎃🎃 Happy Halloween Steve 👻👽👹☠️
@ClickinChicken3 ай бұрын
hot damn! it works!! Thanks for another one Steve!
@charlesashman12523 ай бұрын
Tell us how your truck has been
@bdac24202 ай бұрын
Been there, done that, shit show for sure. Steve. Great video. Thank you.
@RobertSkene-qw3ob3 ай бұрын
Thermostat set on cooling 😂🇨🇦. Old vet in this trade!!
@topher86343 ай бұрын
It does sound like a bad board, especially if it's giving you a twinning fault. It's a single furnace, definitely not twinned. And seeing all that rust and corrosion, it looks like water has been leaking all over it. Probably a previously or current clogged evap drain.
@force3119993 ай бұрын
or air intak don,t have a drip scoop in it
@SignorNessuno653 ай бұрын
Remember when furnaces were bullet proof?
@Garth20113 ай бұрын
Wow, 7 burner tubes ! 140,000 BTU ? There was a dark spot on the lower backside of that main board I believe. What are the negatives with those NEST thermostats? Or limitations?
@SkilledLabor17 күн бұрын
100,000 Btu furnace
@Garth201117 күн бұрын
@@SkilledLabor Each burner in a furnace is about 20,000 BTU I thought?
@SkilledLabor17 күн бұрын
@ Varies with manufacturers. That’s a 92% 100,000 Btu C cabinet (21”) wide with 5 ton drive. You can see the model number.
@Garth201117 күн бұрын
@@SkilledLabor I'm DIY. So far, I think the best value in HVAC is single stage and 80% over the long haul.
@SkilledLabor17 күн бұрын
@@Garth2011 Agreed. Some of the old 90% furnaces were tanks and lasted much longer than modern equipment. 80% single stage will probably be the most reliable longterm option, boilers especially 80% is the most reliable. I like 2 stage units, but repairs will be more money down the road for the average homeowner. I’m not a fan of the overly complicated systems out there
@Tuberokjv16113 ай бұрын
What brand of furnace is this?
@mattbuckmeier51613 ай бұрын
Rheem
@richardreynolds98853 ай бұрын
Troubleshooting videos my favorite Steve
@TheRAMBO91913 ай бұрын
💪🏻😄✌🏼
@bobweiss86823 ай бұрын
Hate to break it to you, but those blue vinyl gloves won't do anything to prevent ESD damage to boards, and may even increase the chances of it. What you need to be doing is wearing a wrist strap, grounded to the frame of the furnace.
@reverett05083 ай бұрын
Agree. And/or touch ground before messing with it if you don't have a wrist strap.
@spacemanwithraygun39333 ай бұрын
Unless you are shuffling around on carpet in your socks you'll be fine. It's more of a precaution, unless you're building out a computer system.
@Garth20113 ай бұрын
Some agree, he was working on concrete plus touching the sheet metal most of the time so Steve is doing okay on this job. Carpeting would be the environment to be careful but as long as you are touching the cabinet or a pipe etc. prior to handling the board, you are safe. Those wrist straps do work but if you know what you are doing you can prevent ESD without one.
@davedonahue76433 ай бұрын
Nobody gives a shit bro
@Burritto772 ай бұрын
Blue nitrile gloves are inherently non-conductive. They reduce direct skin contact (a primary source of static).
@ramunesoda733953 ай бұрын
Hi Steve, Will there be anymore cooking videos? I love watching the "Workin Men Cooking" Series
@HearTbeat_9993 ай бұрын
It would be a good idea to plug the fan directly into 110v. with simple extension cord. You can test all fans that way.
@flyer6173 ай бұрын
The gloves won't do anything to protect against static discharge. They may even make it worse. What you need is an anti-static wrist strap which you connect to ground.
@ClickinChicken3 ай бұрын
I think I see what you are saying. LIke when he handles the board? maybe it's a non issue.. IDK
@gumbootcloggers83303 ай бұрын
Basements are usually damp and static not a poblem.
@flyer6173 ай бұрын
@@gumbootcloggers8330 Heating systems fail (or are noticed) more often during the winter when the RH is low, even in the basement. If you want to protect against ESD then do it right, it's cheap! That's from a guy who repairs these boards. Your choice as to what you do with that info. There are other things you can do as well but the wrist strap is the simplest.
@joeburner71203 ай бұрын
@@flyer617That board is $85 at the supply house. Is it worth the effort to repair them. When in doubt, swap it out. Charge the customer $125 for diagnostic $225 for labor and sell them the board for $300. Get $750 from the job and forget about the guy that “repairs” the boards.
@flyer6173 ай бұрын
@@joeburner7120 I get paid to analyze the failures and improve the designs. Nobody reuses the boards after I fix them, they get recycled.